Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.6 L+₹1.6 L (6.43%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹26.6 L+₹1.7 L (6.69%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹26.7 L+₹1.7 L (6.78%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹27.4 L+₹2.4 L (9.70%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
REPAIR TO ROOF SHEETING TREATMENT ALL ALLIED WORK UNDER AGE B/R II OF GE (AF) CHAKERI AT AFS CHAKERI KANPUR
2024_MES_646865_1
GE (AF) BR/CHK/T-65 OF 2023-24 8926/E8
Open Tender
Civil Works
Item Rate
270 days
GE(AF) B/R Chakeri Kanpur
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹60,000
Yes
2 Sept 2024
18 Mar 2024
24 Apr 2024
18 Mar 2024
17 Apr 2024
5 Apr 2024
Amount
Dismantling asbestos cement (corrugated or semi corrugated etc) sheets incl wind ties in roof coverings complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge or thickness at any position or similar pattern of roof covering complete all as specified and directed.
S&F coloured galvalume sheet with base metal thickness ( BMT) 0.50 mm multi rib profile minimum 550 Mpa yield strength having maximum pitch of 250 mm c/c and minimum 28 mm crest depth, AZ 150, as in roof covering/ clading to wall fixed with self tapping screws complete all as manufactureres instruction, specified and directed by Engr-in-Charge.
S&F for 0.50 mm thick colour coated plain sheet AZ 150 as in ridge to match the existing roof coverings complete all as manufacturrers instruction complete all as manufactureres instruction, specified and directed by Engr-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
M&L Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6. complete all as specified and directed.
M&L for Plain cement concrete type B1 1:2:4 (using 20 mm granite stone aggregate) in roof kerbs, mud stops or chamfered on edges inculding demolition complete all as specified.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:6) on brick wall of concrete and finished even smooth without using extra cement complete all as per specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of cement base primer on surfaces of walls complete all as specified & directed.
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down shutters of any decription exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed.
S&F Solid PVC door frame of size 50mm 47 mm made out of 5mm plain colour PVC sheet rinforced with MS Square tube suppling and fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter,28 to 30 mm thick 'Stiles' with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC sheet on the front face and 2 mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing complete all as specified and directed.
M & L for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercials type on both sides complete all a specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repair for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned sacks or galvanized wire staples complete all as specified and directed.
Supply and fixed in repair mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller platecomplete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed..
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
M & L for preparation of new wooden surfaces and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and directed.
M&L for applying bitumen primer @ 0.40 Ltr per sqm and applying water proofing treatement using 3mm thick APP modified polymeric membrane with Gravel/Granular finishes, sealed with torch application laid over & including 10 mm thick screed bed in CM 1:3, overlaps shall be sealed with torch application complete including demolition of existing roof surfaces of any typesetc all as specified & directed by Engr-in-Charge.
Supply only integral water proofing compound.
M&L for reinforced elastromeric PU based liquid water proofing compound membrane with resilient acrylic polymers having sun reflectivity Index (SRI) of 105 as approved by GE on top of roof surface in three coats @ 10.76 ltr /10 Sqm. One coat of self priming of elastomeric PU based water proofing liquid (dilution with water in the ratio of 3 :1 i.e. 3 part of water proofing liquid and one part of water), laying of Geo Txtile Fleece and two coats of undiluted elastomeric water proofing liquid. The dry film thickness of complete allocation/ system should not be less than 600 micron. The treatment shall be carried out through authorised representative of manufacturer and application shall be by mechanical sprayers complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on roof surface of concrete and finished even smooth without using extra cement complete all as per specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets including grid work complete all as specified and directed.
S&F 16mm thick of size 595 x 595/600 x 600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled tegular ) of Armstrong or equivalent make and model including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping ,main runner and cross runner and to comprise main tee/runner 15 mm x 38mm size (load carring capacity 14 kg /sqm ) spaced at 1200 mm centres securely fixed to the structural sofit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm module , cut sub cross tee/runner 600mm require independent support ,wall angle of size 19mm x 19mm secured to the periphery of the wall at 450 mm maximum centre the above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350mm , complete all as specified and directed
Supply and fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and pattern having moister content less than 2%, humidity resistant of 99%, NRCO.50 to 0.75 as per IS 8225:1987, noncombustible as per BS 476 (part 4) - 1970 and light reflectance of 85% minimum to be laid in true horizental level suspended on inter-locking metal T-Grid of hot dipped galvanised ireon section of 0.33mm thick (galvanised @120gm/Sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross T of size 15 x 32 mm of length 1200mm and secondary intermediate corss T of size 15 x 32 mm of length 600mm to from grid module of size 600x 600 mm suspended from ceiling using galvanised mild steel items (galvanised @ 80gm/Sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifiection, drawing and complete all as specified and directed.
Material and labour for making functional to existing hanger sliding shutter of size exc 50 Sqm but not exc 60 Sqm each, by replacing unserviceable ball bearings, shafts (rolling pin) , roller, correcting/ straightening and cleaning of guide rails etc including greasing for easing of shutters, complete all as specified and directed.
Closing bolt holes and water tightening of self tapping screw/J bolt in GI/Galvalume roof sheeting with using ready to use tarplastic water proofing sealent in cold application including replacement of defective tapping screw/J bolt screw comple all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for full body Vitrified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. laid over and including 15 mm thick screed bed in CM 1:6 set and jointed inneat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for full body Vitrified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in dado/skirting etc. and cncluding 10 mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed.
M/S SDS Construction Co.
Khalil Ahmed and Sons
BVV ENTERPRISES
SAI KRIPA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .