Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.4 L+₹3.0 L (7.80%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹42.8 L+₹4.4 L (11.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹43.4 L+₹5.0 L (12.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹44.7 L+₹6.3 L (16.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹42.5 L
EMD Value
₹84,900
Closing Date
22 Mar 2022, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
SPECIAL REPAIR TO ROOF OF BLDG NO T92 21SRW SPECIAL REPAIR TO BLDG NO P158 24SRW PROVN OF CANDIDATES WAITING AREA FOR 33 SSB REV03 PROVN OF COOKING SHELTER AT SUKHI SEWANIA MW17 AND ADD ALTN TO BATH OF BLDG NO P94 MW26 AT SI LINE UNDER GE BHOPAL
2022_MES_507043_2
8848/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹84,900
Yes
28 Mar 2022
15 Mar 2022
23 Mar 2022
15 Mar 2022
22 Mar 2022
17 Mar 2022
Amount
Note : Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below:-
Demolition of brick work, built in Cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified and directed.
Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
S&F Mild Steel work in tubular/structural trusses, purlins, mild steel plate etc including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 or steel sections conforming to Fe 410-W (Gde E-250) quality -A complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in roof coverings/cladding to wall, etc, fixed with & including self tapping screws on angle frame complete all as specified and directed. [MAKE: TATA BLUE SCOPE / EVEREST INDUSTRIES/JINDAL]
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in ridges, etc, fixed with & including self tapping screws complete all as specified and directed. [MAKE: TATA BLUE SCOPE / EVEREST INDUSTRIES/JINDAL]
S&F Mild steel work conforming to Fe-290 Gde E-165 angle iron, flat iron, MS plate as in bracket, cleats, fasteners, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed., drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
S&F Mild steel conforming to Fe-290 Gde E-165 in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings and similar work complete all as specified and directed.
Supplying, fabricating and fixing powder coated (minimum thickness 50 micron) aluminium sections of required size for door, windows, ventilators frames and shutters and partitions including aluminium hinges of required size jointing cleats, screws sash fasteners, plug for fixing with walls, columns, etc complete all as specified and directed. [MAKE: JINDAL/ AJIT INDIA/ HINDALCO]
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Sheet glass 4.8 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
S&F Figured glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cm 1:6 all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed. [MAKE: ACCOPROOF/WATER SEAL/MC BOUCHAMIE, MUMBAI/FOSROC/CICO/PIDILITE]
M&L for heavy duty flooring tiles, harsh weather & UV Resistance, high abrasion resistance, MOH Hardness >6, thickness 10 mm thick, area of each tile not less than 0.09 sqm, anti slip type, laid in floors, steps, edges, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tile with & including 15mm thick screed in CM 1:4 complete all as specified and directed. [MAKE:-JOHNSON ENDURA or equivalent in SOMANY/ KAJARIA/ORIENT as approved by GE]
M&L for Factory made, machine pressed, M-35 grade concrete interlocking paver blocks (glossy /reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 60 mm thickness with & including 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [MAKE:- MEHTAB / NAVYA TILES / SAP PAVERS/ SAGAR TILES]
M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over and including a coat of cement wash complete all as specified and directed.
M&L for applying 3mm thick wall care putty (Make: Birla/JK) complete all as specified and directed.
M&L for Complete removal of existing treatment from walls and applying two coats of oil bound distemper over a coat of cement based putty complete all as specified and as directed. Note: Putty shall be measured and paid for seperately under respective item.
S&F GI frame work size of grid 605 mm x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylong sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two eaqual flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kuled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed
S&F asbestos free calcium silicate board of size 600x600x6mm, fixed to steel frame work in ceiling with & including applying two coats of oil bound distemper complete all as specified & directed. NOTE:- Cost of making frame work for light fittings, etc is deemed to be included in the quoted unit rate
M&L for vitrified light shade flooring tiles, 10 mm thick (Square/ rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, laid in floors, skirting etc set and jointed in neat cement slurry and pointed in epoxy adhisive (Make :Dr.Fixit or Balendura) to match the colour of tiles with & including 15mm thick rendering in CM 1:4 complete all as specified and directed. [MAKE: SOMANY / KAJARIA / NITCO]
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior acrylic emulsion paint, white or tinted over and including a coat of exterior wall primer on plastered surfaces complete all as specified and directed. [Make :Asian(ACE) / equivalent in Shalimar / Burger
Taking down shutters of any description not exceeding 1 Sqm each, complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
Taking up or down 15 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed.
Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
M&L for cutting holes in brick walls exc half brick but n exc one brick in cement mortar for incerting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete type B1, 1:2:4 as required, complete all as specified and directed.
S&F Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, with & including filing of cement concrete typ B-0, 1:2:4 using 12.5mm graded stone aggregates inside frames complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, roof kerb, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH]
S&F Steel water tubes, medium grade, ISI marked, galvanised, 20 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH]
M&L for Joint free non skid ceramic coloured tiles 7mm to 8mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 15mm thick screed bed in CM 1:6 complete all as specified and directed. [MAKE: SOMANY/ KAJARIA/ ORIENT/ JOHNSON]
M&L for Glazed ceramic coloured tiles 350mm x 250mm x 7mm thick or 300mm x 450mm x 7mm thick, in vertical surfaces such as skirting, dados and risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 10mm thick rendering in CM 1:3 complete all as specified and directed. [MAKE: SOMANY/ KAJARIA/ ORIENT/ JOHNSON]
Roughning of surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and directed.
M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding, moulding and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for 25mm thick Cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate in sub base, floor finishes complete all as specified and directed.
M&L for making good under cills and over arches, lintels and bressummers including all pinning where necessary in cement mortor 1:6, complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, 100 mm size complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, 75 mm size complete all as specified and directed.
S&F Butt hinges, extruded alluminium alloy with galvanised mild steel hinge pin, anodised and fixed, 100 mm size complete all as specified and directed.
S&F 150 mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 100 mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 150 mm Aluminium anodised barrel Tower bolts extruded section and fixed complete all as specified and directed
S&F 100 mm Aluminium anodised barrel Tower bolts extruded section and fixed complete all as specified and directed
S&F 40mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type with decorative lamination on both sides complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and Skelton door shutter open rebated and prepared to receive glass or gauge etc divided into square with plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note: - Size of member of shutters as specified in SSR Part-I 1991 section 8 clause 8.24 (a) complete all as specified and directed.
M&L for Preparing new or previously untreated surfaces of wood and wood based materials of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed.
M&L for preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 300mm long aluminium alloy anodised Sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed
S&F Wash basin mixture, centre hole, cast copper alloy, screwed down, high pressure, with capstan head, fancy type, chromium plated screwed for iron pipe or for unions 15mm bore, complete all as specified and directed. [MAKE: PRAYAG (Cat.No.7250) or equivalent in MARC/ PLUMBER as approved by GE]
S&F in repairs wall mixture telephonic with crutch for mixing hot & cold water, fancy type, chromium plated, screwed for iron pipe or for unions 15mm bore, with & including hand shower & tube complete all as specified and directed. [MAKE:- Prayag (Wall mixer cat No.7270 or 7370, shower cat no.BH-73) or equivalent in JAQUAR / PLUMBER / MARC as approved by GE]
S&F hand shower (health faucet) with 8mm dia 1.0 mter long flexible tube and wall hook complete all as specified and directed. [MAKE:- Prayag (Cat No.BH-76) or equivalent in JAQUAR/MARC as approved by GE]
S&F Chromium plated grating doom, including jointing with solvent cement, dia of outlet 100 mm complete all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 750 mm complete all as specified and directed.
S&F Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed. [MAKE:- Prayag (Cat No.8606) or equivalent in JAQUAR/MARC as approved by GE]
S&F in repairs Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup screwed both ends for iron pipe or for unions 15mm bore complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
S&F PVC (SWR) floor/Nahani trap, plain with CP grating including jointing with solvent cement, dia of outlet 100 mm complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, etc. including cleaning or refixing or removal to store, complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece single (single Y), 110mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece single (single Y), 75mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 110mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 75mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
S&F in repair PVC Flexible waste pipe 32 mm dia with socket for steel sink upto floor level and length not less than 0.60 M complete all as specified and directed.
S&F tubular towel rail of aluminium anodised, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. [MAKE:- Prayag (Cat No.BA-40) or equivalent in JAQUAR/MARC as approved by GE]
S&F in repair of vitreous China wash down water closet pan, cascade type (pedestal pattern), with integral seat cover and flush tank, coloured (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. [Make - Cat No 92085 of make hindware or Cat No OPS-WHT-15853S300UF of Jaquar as approved by GE.]
S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12.5 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. [MAKE:- Prayag (Cat No.BEA-43) or equivalent in JAQUAR/CERA as approve by GE]
S&F two way Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed. [MAKE:- Prayag (Cat No.8612) or equivalent in JAQUAR/MARC as approved by GE]
S&F in repairs Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (angle type) screwed both ends for iron pipe or for unions 15mm bore, complete all as specified and directed. [MAKE:- Prayag (Cat No.8610) or equivalent in JAGUAR/MARC as approved by GE]
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, ceilings, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for struck pointing to random or polygonal rubble masonry, uncoursed or brought up to course in cement cement mortor 1:4 complete all as specified and directed.
M&L for preparation of old/new surfaces of wall and applying two coats of damp proof chemical (Acra coat of make Dr. Fixit) over a coat of cement based white putty, complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-25, as in slabs supported in walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use & waste of Form work to sides & soffits of slabs etc for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for struck pointing to squared rubble masonry, uncoursed or brought up to course in cement cement mortor 1:4 complete all as specified and directed.
M&L for Machine cut Kota stone slab flooring 20-25mm thick with and including 20mm thick cement screed base in CM 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Mild steel TMT Bar 6 to 8mmm dia cut to length, bent to shape to required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (anneled ) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior weather proof water base emulsion paint on wall over a coat of white cement based putty, complete all as specified and directed. [Make:- Apex Ultima Paint of M/s Asian Paints or equivalent in M/s Berger or M/s ICI or Shalimar as approved by GE]
M&L for complete removal of existing treatment of wall and applying two coats of exterior weather proof water base emulsion paint on wall over a coat of white cement based putty, complete all as specified and directed. [Make:- Apex Ultima Paint of M/s Asian Paints or equivalent in M/s Berger or M/s ICI or Shalimar as approved by GE]
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of cement based putty complete all as specified and as directed. (Note: Putty shall be measured and paid seperately.)
S&F drepary rod decorative type min 25mm dia, curtain rod chromium plated with side fixing brackets, rings & including decorative knobs complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 500 and n exc 1000 ltr. including Cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
Refixing old steel tubing 20 mm bore, with and provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and directed.
Refixing old steel tubing 15 mm bore, with and provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and directed.
Taking down existing old roof treatment of any description, type and in any position including removal of old tiles, screed, felt, etc complete all as specified and directed.
M&L for grouting by pressure injection with cement slurry of 50kg cement mixed with Pidicrete SM 225gms of M/s Pidilite industries Ltd. Or Cobex 100 of M/s Fosroc Chemicals as per instructions, complete all as specified and directed.
M&L for 25mm thick fillet of PCC type B0 1:2:4 (12.5mm graded stone agrregate) 100mm wide and 100mm height in rounded/triangular shape shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. Themembrance should not be taken overat any sleep turns and hence all corners, junctions should be rounded for padding of roof, complete all as specified and directed.
M&L for Providing precast reinforced cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in louvers and jallies 25mm thick (measured solid) including all mouldings but excluding frame and set in cement mortar 1:4 complete all as specified and directed.
S&F PVC sheet 12mm thick for partition, complete all as specified and directed.
M&L for Water proofing treatment on roof surfaces with APP modified membrane with non woven polyester reinforced, weight not less than 3 KG/SQM and thickness of membrane not less than 3mm laid in following sequence including applying a coat of aluminium paint over APP membrane complete all as specified and directed.:- (a) Complete removal of existing treatment including padding/plastering (which shall be measured under item No 111.00) (b) Conduct ponding test for 72 hrs, after ponding test grouting is to be done at the leakage area as directed by Engr in charge (Grouting shall be measured under item No 112.00) (c ) After the surface is repaired with pressure grouting the slab will be tested for water tightness again for 72 hrs before processing further treatment. (d) Applying 10mm thick plaster in CM 1:4 mixed with water proofing compound [Make; Dr.Fixit Pidiproof LW+ of M/s Pidilite Industries or STP No. 1 (liquid) of M/s STP Ltd] @ 3% by weight of cement on cleaned roof surface. (e) Properly cleaning and drying of the plastered roof surfaces, parapets, gutters, drain mouths, etc for all foreign matters such as fungus, moss, dust, etc by wire brushing and dusting. Proper grooves shall be cut around CI drain outlets/pipes/chimney pipes and other similar situations to tuck in the treatment. (f) Applying a coat of bituminous primer conforming to IS: 3384-1965 @ 0.3Kg/Sqm on the prepared surface till the surface is properly impregnated. (g) Laying APP modified water proofing membrane with 100mm overlap in longitudinal direction and 100mm overlap in transverse direction sealed and bounded to the surface by torch application method. (h) All joints and changes in direction should be curved with cement mortar 1:3 with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. A fillet of PCC 1:2:4 type B0 using 12.5mm graded stone aggregates shall be provided at all junctions of vertical and horizontal surfaces and wherever there is change of direction. (j) 72 hrs testing of treatment for water tightness by ponding of water.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove by using wire netting of galvanised steel wire with cement mortar 1:3, complete all as specified and directed. (Note : Galvanised steel wire netting shall be measured and paid separately.)
S&F Galvanised steel wire netting of 1.40mm dia wire and size of mesh 12mm, complete all as specified and directed.
M&L for cutting grooves in brick/concrete block wall, 12mm wide and 70mm deep using diamond blade cutter machine to inserting TMT bars as required width and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed. (Note : TMT bar shall be measured and paid separately.)
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
M&L for Hardcore of Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and lev-elled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers not exc. 15cm thick, spread, levelled and blinded with earth and rammed including watering complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed.
M&L for cement concrete 1:3:6, Type B2 (using40 mm graded stone aggregate) in foundations, post holes filling and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for factory made, second class hardwood 35mm thick plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed.
M&L for factory made second class hardwood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle, and peg stay, complete with wire gauzed, dovetailed or welded complete all as specified and directed.
S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
M&L 15mm thick rendering in CM 1:4 on brick/concrete surfaces including finishing the surfaces even and smooth (without using extra cement) with using WPC complete all as specified and directed. NOTE : WPC shall be measured and paid separately.
M&L for Reinforced cement concrete type B0, 1:2:4 (using 12.5mm graded stone aggregate) (nominal mix) in foundations, footing, plinth beams, bases for columns and mass concrete, complete all as specified and directed.
M&L for Reinforced cement concrete type B0, 1:2:4 (using 12.5mm graded stone aggregate) (nominal mix) in columns, pillars, piers and posts etc, complete all as specified and directed.
M&L for Reinforced cement concrete type B0, 1:2:4 (using 12.5mm graded stone aggregate) (nominal mix) in slabs supported, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Reinforced cement concrete type B0, 1:2:4 (using 12.5mm graded stone aggregate) (nominal mix) in lintels over 1.5m clear span, beams and cantilevers complete all as specified and directed.
Use & waste of Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for fair finished flat surfaces of concrete complete all as specified and directed.
Use & waste of Form work to sides of square or rectangular columns, pillars, posts and struts for fair finished surfaces of concrete complete all as specified and directed.
Use & waste of Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for fair finished flat surfaces of concrete complete all as specified and directed.
Use & waste of Form work to edges of concrete flats, openings, floors & roofs and sides of RCC/PCC bands in walls and similar work exceeding 10cm but not exceeding 20cm wide for fair finished surfaces of concrete complete all as specified and directed.
S&F 300mm, ordinary MS rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for 50 mm Sand stone slabs in foothpath, sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and directed.
S&F reinforced concrete pipes, class NP2, 200 mm bore, laid and jointed with collars complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, 150/200 mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and directed.
S&F Vitreous china bowl urinal flat back, white, with grating and union for discharge pipe including connections to flush pipe and outgoing pipes, complete all as specified and directed. [MAKE:-SOMANY (Cat.No.130205), PRAYAG (Cat No.4999) or equivalent in CERA/PARRYWARE/ HINDWARE as approved by GE.]
S&F Vitreous china wash basin, ISI marked, white, flat back, size 550 x 400mm, including CP waste coupling, 32mm dia PVC waste pipe of suitable length, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed. [MAKE:-SOMANY (Cat No.110107) or equivalent in CERA/PARRYWARE /HINDWARE as approved by GE.]
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc.complete all as specified and directed.
M&L for point wiring complete for light/fan/exhaust fan on independent / combine with cable 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC casing and capping of size 25 mm , ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS muti-stranded copper conductor (green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked for mounting of fittings like switches, sockets, fan regulators, etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : (i) Wiring to be done as per approved colour code in IE rule.(ii) Rate includes chase cutting for concealed wiring. [Make of Cable : Polycab/ Plaza/ Havells]
All as per BOQ item No. 148.00 here-in-before, but for one switch socket combination 5/6 Amp on independent board, complete all as specified and directed.
All as per BOQ item No. 148.00 here-in-before, but for one three pin outlet 5 Amp on same board with other switches, complete all as specified and directed.
All as per BOQ item No. 148.00 here-in-before, but for one switch socket combination 6 pin 5 /15 Amp on independent board with wire of size 2.5 sqmm and 2.5 sqmm as earth wire, complete all as specified and directed.
All as per BOQ item No. 148.00 here-in-before, but for one switch socket combination 6 pin 5 /15 Amp on independent board with wire of size 4.0 sqmm and 4.0 sqmm as earth wire, complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet 5 pin 5 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch socket combination 6 pin, type 5/15 Amps flush type, 230 volt AC complete all as specified and directed. MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F LED tube light fitting, surface mounted lumanaires, 1 x 18 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells Cat No : LHEXBLP7N1W018 or equivalant in C&G/Bajaj/Surya as approved by GE.
S&F LED light luminaire 600mm x 600mm, 35/36 Watt, 240 V AC recessed type with high efficiency PMMA diffuser soft glare free light, complete with driver, holder and LED lamp suitable for roof ceiling, including connecting with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed.
S&F LED tube light fitting, surface mounted lumanaires, 1 x 18 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps,connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells Cat No : LHEXBLP7N1W018 or equivalant in C&G/Bajaj/Surya
S&F Angle holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F LED lamp 10 watt, B22 CDL complete all as spcified and directed.
S&F energy saving and environment friendly LED security light fitting of 30 Watt with high power LEDs with lens and IP 66 protection and luminaire housing is of pressure die cast aluminium alloy for heat sink for better heat heat transmission with polycarbonate cover and fixing on bracket of suitable size and making electric connection from light source to fitting with 1.5 sqmm PVC Aluminium stranded conductor 2 core of required length (approx 10 m) and testing on completion, complete all as specified and directed. [MAKE - ORIENT ELECTRIC Cat No LSFS-030-CF or equivalent in HAVELLS/CROMPTON/ WIPRO/BAJAJ as approved by GE]
S&F fan step regulator, 120 watts, 2 module complete all as specified and directed. (Make:- Legrand (Cat. No.573469) or equivalent in Anchor ROMA DEKO 'D' series)
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including concealed 25mm dia, rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: - (i) Two runs of 6.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length. (ii) Cutting chases & making good for concealed sub main wiring will be measured and paid sepeartely under susequent item. [Make of Cable : Polycab/ Plaza/ Havells]
S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 ways (VTPN MCCB DB) and space for MCCB as incomer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. NOTE:- MCCB shall be measured and paid seperatly. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F of MCCB 4 pole, 125 Amp, 16kA breaking capacity with complete electric connections by appropriate size of copper lugs including taking down old unserviceable DB complete all as specified and directed. Make :- Havells/Indo Asian /L&T.
S&F in replacement sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid separately.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 50 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB 25 Amps, 240 volts complete all as specified and as directed.
Taking down carefully existing ceiling fan from fan hook and disconnection from ceiling rose, cleaning and painting with white enameled paint greasing/oiling and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F modular bell push, 6Amp, one module, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S&F modular switch, one way, 16 Amp, one module, 240 Volts, complete all as specified and as directed.
S&F Modular socket outlets, two in one, three pin, 6 Amp, 2 modules, 240 V, AC, 50 Hz with earthing contact, controlled by one switch, complete all as specified and as directed.
S&F Modular socket outlets, two in one, three pin, 16 Amp, 2 modules, 240 V, AC, 50 Hz with earthing contact, controlled by one switch, complete all as specified and as directed.
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND /HAVELLS as approved by GE]
Supply & fixing LED light fitting mirror type with hig out put diffuser 2 feet, 10 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible coppder conductor cable of suitable size complete all as specified and as directed.
S&F Decorative wall mounting champagne gild finish fixture with plastic body suitable for 9 watt LED lamp B22 base fittings, complete all as specified and as directed.
S&F LED lamp 9 watt, B22 CDL complete all as spcified and directed.
S&F in repair on load changeover switch, rotary type 200 Amp, 415 V, TPN, front operated without sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement, complete all as spcified and directed.
S&F in replacement sheet metal enclosure double door type surface mounted concealed in wall 4 ways SPN, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. [MAKE:Hegar (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid separately.
S&F ceiling fan 1200 mm sweep single phase AC 220 Volts 50 HZ, 3 blades double ball bearing and connecting including provision of 3 core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/connector to fan, etc including GI down rod of appropriate length as per site requirement including taking down of old fan and depositing in AGE E/M store yard complete all as specified & directed. [Make:- Crompton (Model- "Cool Breeze Plus" 3 star rating) or equivalent in Usha/ Havells as approved by GE.]
S&F Verticle storage water heater (Geyser), 240V, AC, Single phase, 50 Hz of 25 ltrs capacity, with heating element of 2.0 KW, stainless steel tank, 5 star rating, with indicator lamps for thermostat operation, with max rated pressure 8 bar, fixing to wall by means of dash fashner of min 80 mm long ( Vertical wall mounting), including connecting with cold and hot water pipe lines, heavy grade, of size 15 mm x 450 mm length with rubber washer, making complete connection and testing of geyser for its staisfactory functioning complete all as specified and directed.
S&F exhaust fan with louvers, AC Single phase 230/240 volts, 50 Hz, 250 mm sweep, 1200 RPM, 5 star rating, including nut bolt and connecting accessories, including cutting for making opening in wall and making good disturbed surfaces after fixing of exhaust fan and louvers including connection with 23/.0076 three core copper wire from ceilling rose to exhaust fan upto 1 mtr length complete all as specified and directed. [MAKE - HAVELLS or equivalent in USHA/ CROMPTON as approved by GE]
Supply, laying, fixing on wall or passing through pipe, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 16 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE]
S&F 40mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed. [MAKE:-TATA / JINDAL / PRAKASH / SWASTIK as approved by GE]
Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed. Note:-GI pipe shall be measured & paid separately under relevant items of this schedule.
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 50 sqmm, 3.5 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE]
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 40 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH]
S&F Steel water tubes, medium grade, ISI marked, galvanised, 25 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH]
S&F Gun metal globe or gate valves, 40 mm bore, with iron wheel head, screwed both ends for iron pipe for the following bores including taking out old unserviceable valve complete all as specified and directed. [MAKE:-SANT / LEADER / RAMCO / ZOLOTO as approved by GE]
S&F Gun metal globe or gate valves, 25 mm bore, with iron wheel head, screwed both ends for iron pipe for the following bores including taking out old unserviceable valve complete all as specified and directed. [MAKE:-SANT / LEADER / RAMCO / ZOLOTO as approved by GE]
S&F Gun metal globe or gate valves, 20 mm bore, with iron wheel head, screwed both ends for iron pipe for the following bores including taking out old unserviceable valve complete all as specified and directed. [MAKE:-SANT / LEADER / RAMCO / ZOLOTO as approved by GE]
S&F Rotational moulded (three layered, ISI marked) polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity including PVC cover, hoisted and fixed in position including connecting up pipes complete all as specified and directed. [MAKE:-SINTEX/ POLYWELL/ POLYCON/POLYPLAST]
S&F Rotational moulded (three layered, ISI marked) polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity including PVC cover, hoisted and fixed in position including connecting up pipes, complete all as specified and directed. [MAKE:-SINTEX/ POLYWELL/ POLYCON/POLYPLAST]
S&F Mild steel three seater public place seating chair of MS ERW tube with arm and back rest, without cushion, complete all as specified and directed. [Make - Sharon Furniture, Product ID 5116877-38908306738 or equivalent as approved by GE.]
S&F towel rack with hanger, stainless steel complete all as specified and directed. [MAKE: JAQUAR Cat No AKP35781PS or equivalent in Prayag/ MARC as approved by GE]
S&F stainless steel kitchen plate rack overall size- 31" x 24" x 10" duly fixed on walls with gutties & screws of suitable length complete all as specified and directed. [MAKE:- Prayag (Cat No.P-340) or equivalent in NIRALI/BLUE STAR as approved by GE]
Deduct schedule of credit (calculation will be done off line) Rs. 43470.00
M/s VIKAS TRADERS
MODI CORPORATION
NDS TRADERS
RAJPATI CONSTRUCTION
M/S Shanti Traders
AJIT ENTERPRISES
Samaksh Enterprises
NIHAL ENTERPRISES
M/S AJAY JAIN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .