| 1 | L1₹10.8 LAccepted-AOC PLOT NO 373 NARENDRA DEO PANDEY KOSABADI KORBA KORBA CG 495677 | KORBA | KORBA | CHHATTISGARH | 495677 | L1 | Accepted-AOC TC recommends to award the work in favour of L1 bidder S.T. Construction for total work order value of Rs.1078248.60. | |
| 2 | L2₹11.5 L+₹72,622.81 (6.74%)Rejected-Finance MIG 2BY1 PT R S S NAGAR KORBA CG 495677 | KORBA | CHHATTISGARH | 495677 | L2 | Rejected-Finance L2 | |
| 3 | L3₹12.4 L+₹1.6 L (15.2%)Rejected-Finance | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | JAISHANKAR PANDEY L2 | AMIT ASSOCIATES L3 | S.T. Construction L1 |
|---|---|---|---|---|---|---|
| 1.00Item Description/ Heading | ||||||
| 1.01 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes | 560 | metre | 60 ₹33,600 Lowest | 100 ₹56,000 | 92 ₹51,520 |
| 1.02 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes | 600 | metre | 80 ₹48,000 Lowest | 100 ₹60,000 | 100 ₹60,000 |
| 1.03 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes | 360 | metre | 100 ₹36,000 Lowest | 100 ₹36,000 Lowest | 115 ₹41,400 |
| 1.04 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore | 300 | No. | 400 ₹1,20,000 | 250 ₹75,000 | 205 ₹61,500 Lowest |
| 1.05 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore | 130 | No. | 400 ₹52,000 | 250 ₹32,500 Lowest | 300 ₹39,000 |
| 1.06 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on wall 20 mm dia nominal bore | 130 | metre | 180 ₹23,400 | 150 ₹19,500 Lowest | 175 ₹22,750 |
| 1.07 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on wall 25 mm dia nominal bore | 130 | metre | 250 ₹32,500 | 200 ₹26,000 | 195 ₹25,350 Lowest |
| 1.08 | Providing and fixing PVC gate valve of approved quality
15 mm nominal bore | 20 | No. | 114.6 ₹2,292 | 50 ₹1,000 Lowest | 55 ₹1,100 |
| 1.09 | Providing and fixing PVC gate valve of approved quality
20 mm nominal bore | 20 | No. | 158.5 ₹3,170 | 80 ₹1,600 Lowest | 85 ₹1,700 |
Tender Value
₹21.5 L
EMD Value
₹27,000
Closing Date
7 Jul 2025, 5:00 pmClosed
Sr. MANAGER (CIVIL), CWS-CS, KORBA
OFFICE OF THE STAFF OFFICER (CIVIL), CWS-CS, KORBA
Annual internal water supply works in different colonies (SBS, JP, SB, DC, 15 Block, Pump House ) under quarters of CWS-CS Korba
2025_SECL_338349_1
SECL/CWS/KB/SO(C)/ET/25-26/03 DTD.25.06.25
Open Tender
AMC WORKS
Item Rate
365 days
SECL, CWS-CS
Please refer tender document
3 documents required · 3 mandatory
₹27,000
5 Sept 2025
27 Jun 2025
9 Jul 2025
28 Jun 2025
7 Jul 2025
28 Jun 2025
28 Jun 2025 - 3 Jul 2025
Amount
Item Description/ Heading
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore
Providing and fixing PVC gate valve of approved quality 15 mm nominal bore
Providing and fixing PVC gate valve of approved quality 20 mm nominal bore
Providing and fixing PVC gate valve of approved quality 25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
Providing and fixing C.P. brass pillar cock of approved quality : 15mm nominal bore
Providing and fixing PVC Union in CPVC pipe etc. complete as per direction of Engineer in charge. 15 mm nominal bore
Providing and fixing PVC Union in CPVC pipe etc. complete as per direction of Engineer in charge. 20 mm nominal bore
Providing and fixing PVC Union in CPVC pipe etc. complete as per direction of Engineer in charge. 25 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 98 mm long, weighing not less than 75 gms
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : Flat back wash basin of size 550x400 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Operating gate valve in water supply pipe line by enaging labour as per instruction of Engineer in charge. (01 Labour per day)
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank and disposing of malba all complete as per direction of Engineer-in-Charge. (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Providing and fixing CPVC Female Thread Connector/ Adopter of required dia. As per direction of Engineer in charge. 15mm nominal dia.
Providing and fixing CPVC Male Thread Connector/ Adopter of required dia. As per direction of Engineer in charge. 15mm nominal dia.
Providing and fixing 32 mm C.P. brass waste of standard pattern for wash basin/sink as per direction of Engineer in charge.
Providing and fixing C.I. bracket for wash basin and sinks as per direction of Engineer in charge.
Providing and fixing in position sintex tank connection of standard pattern as per direction of Engineer in charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall
Total impact of GST for the purpose of CTC
JAISHANKAR PANDEY (BID ID -1164571)
AMIT ASSOCIATES (BID ID -1166398)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .