Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC AOC | |
| 2 | L2₹45.7 L+₹7.8 L (20.6%)Rejected-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-Finance Not Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Meeting Enlistment Criteria |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
19 Nov 2024, 6:00 pmClosed
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIRS MAINTENANCE CLEANING OF UG SUMPS OH RESERVOIR CENTRIFUGAL PUMPS SUBMERSIBLE PUMPS AND OTHER CONNECTED ITEMS AT ARMY NAVY AND AFSOD AND REPAIR REPLACEMENT OF EXTERNAL SERVICES ELECTRIFICATION SUPPLY DISTRIBUTION SYSTEM CONNECTE
2024_MES_679964_1
8203
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANGALORE
Class D category b(i)
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH BANGALORE
₹76,000
Yes
17 Jan 2025
17 Oct 2024
26 Nov 2024
17 Oct 2024
19 Nov 2024
31 Oct 2024
17 Oct 2024 - 31 Oct 2024
Amount
M & L excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables / errection of pole etc complete all as specified and as directed.
M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed. Note: Punned thickness will be measured for payment.
S&L sub class 'B' burnt bricks for cable protection complete as specified as directed
S&L cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including taking out the existing unserviceable cable for following size 4 C x 10 Sqmm
All as per item No.6 above but for 4 C x 16 Sqmm
All as per item No.6 above but for 3.5 C x 35 Sqmm
All as per item No.6 above but for 3.5 C x 50 Sqmm
All as per item No.6 above but for 3.5 C x 70 Sqmm
All as per item No.6 above but for 3.5 C x 95 Sqmm
All as per item No.6 above but for 3.5 C x 120 Sqmm
M & L for GI tubing light grade 80mm with all accessories for cable protection fixed on poles / bldgs of laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
S&F MCCBs 4 pole 415 Volts 50HZ incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under including taking down unsv MCCB complete:- MCCB 63/100 Amps ,16 KA with fixed thermal magenetic
All as per item No. 15 above but for MCCB 200 Amps 36 KA with fixed thermal magenetic
All as per item No. 15 above but for MCCB 250 Amps 36 KA adjustable type with thermal Each and magnetic setting
Supply and fix cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core/4core XLPE armoured aluminium conductor cable taking down old cable joint for following sizes:- 50 Sqmm upto 150 Sqmm
All as per item No. 18 above but for 185 Sqmm to 300 Sqmm
M&L for painting of steel tubular/PCC poles of any height and type ,incl security light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed.
Boring of holes under road,pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 80 mm dia bore suitable for 0.4 mpa working pressure. Note:- Quoted rate includes obtaining permission from local Govt. authorities.
Stay assembley complete with all accessories as shown in elect plate No 1 of SSR Part-I consisting of stay rod 16 mm dia 1.8 mtr long,size of stay plate 230 x 230 x 6 mm with nuts,bolts,insulator stay clamps etc. complete all as shown on drawing and as directed . Note :- Excavation and stay wire shall be measured and paid separately
M & L for galvanized stay wire stranded 7/4 mm complete all as specified and as directed
Supply and errect steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-31, 9 mtr long including dismantling and taking down unsv pole complete.
M & L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole, make good to road surface, hard standing etc incl necessary form work all as specified and as directed
M & L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed
Supply & fix in replacement of on load Change over switch 4 pole compact design rating 400 Amps suitable for isolation and prevent leakage current/ flush over between phases complete all as specified and as directed by Engr-in-Charge.
M&L in replacement for Outdoor type with sheet metal enclosure box of size suitable size for 4 pole, 50 Hz, 415V Automatic Transfer switch of capacity 315 A complete all as specified and directed. Make : L&T-FR2 315A 4P 415 V AC-CK90165BSOO or equivalent in - Havells / Standard / Indoasian / C&S complete all as specified and as directed.
M&L in replacement for outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 400 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 250 Amps 36 KA .including removing old unserviceable junction box complete all as specified and as directed
Supply and fix in replacement of Timeline distribution board 32 A 3 pole /230V analog time switch including complete accessories relay contactor, timer etc, all as specified and as directed. Make:- Indoasian, Cat No. TL032AB0 or its equivalent in Standard / Havells / L&T / C&S
M&L for cable finding cable fault in LT cables any sizes complete all as specified and as directed
Supply & Fix in replacement on pole/ wall etc GI pipe bracket made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed.
Supply and fixing, replacement of moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as directed
Supply and fixing in replacement 60 W LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- ENXT P 72 L WH CR PC SD or its equivalent in CG / Havells / Wipro / Philips / C&S
S&F in replacement of new generation 25 Watt post top energy saving IP-65 enviornmental, friendly long life with symmetrically light distribution, spun aluminium with high power LED. Make :- Havells Cat No. CORALPT25WLED757PSYMTOPC or its equivalent in CG / Havells / Wipro / Philips / C&S
S&F in replacement of Stellar LED post-top offering combination of sturdy design, execllent illumination and aesthetics in one go. IP 66 and IK 10 rating ensures it stands tall amid varid environemtnal conditionsl , friendly long life with symmetrically light distribution, spun aluminium with high power LED. Make :- Mk -Havells NEBULAPT40WLED857PSYMTOPC or equivalent in Bajaj / Wipro / Phillips / CG
S&F in replacement of TERRAIN post top lentern is a wether proof indirect lighting solution wich improves horizental uniformity, with reduced glare and improved lighting control saving IP-65 enviornmental, friendly long life with symmetrically light distribution, spun aluminium with high power LED. Make :- Crompton LPTC-40-CDL or equivalent-Phillips / Havells Bajaj / C&S
S&F in replacement of 2 runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors
M&L of ACSR (Aluminium conductor steel reinforced) conductor of any size on poles incl binding wire of appropriate size complete incl clearing of path and branch cutting approx 1 m on either sides of conductor complete all as specified and as directed
Refixing of ACSR conductor connected with new existing wire tightening to insulator incl line clearance by pruning of tree branch approx 1 m apart from conductor tightening side.
M&L for galvanized stay wire stranded 7/4 mm complete all as specified and as directed
Supply, testing and commissioning in replacement of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar for phase & neutral 500 Amps,36 KA capacity Contd/---44
M&L for repair of outdoor type LT panel front opening door upto the size of 2500 x 3000 mm (approx), incl replacement of door hinges with new one and duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of smoke grey colour as directed by Engineer-in-charge complete all specified and as directed.
Disconnecting the electric cable from the terminal box of 5HP motor, Decoupling the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop and performing following works as specified and directed by Engr-in-Charge. (i) Dismantling the motor and taking out the burnt out copper winding /fiber strip/insulating materials and worn out ball bearing - 2 No (ii) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fiber strip/varnishing and made terminal connection of fiber glass coated wire. (iii) Replacement of ball bearing - 2 No (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the Engr-in-charge. (v) Transporting of the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment any add / atln / welding work for alignment of the pump motor apply grease and connecting electrical connections testing complete all as directed and specified by the Engr-in-charge.
All as per item No.46 above but for Disconnecting the electric cable from the terminal box of 15HP motor, disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop as specified and directed by Engr-in-Charge
All as per item No.46 above but for Disconnecting the electric cable from the terminal box of 25HP motor ,disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop as specified and directed by Engr-in-Charge
Removing the defective single phase preventer from star / delta starter and supply and fixing new single phase preventer suitable for 5 to 60 HP capacity of motors
Repair the star / delta starter fully automatic & different starter including replacing with new spares ie. Contactor, timer, relays etc suitable for existing make and capacity of ML1/ML2/ML3/ML4/ML1.5/MK1. Note : Spares shall be measured and paid separately.
Dismantling the existing old pressure gauge from the pump set/water supply line and provision of new pressure guage 1-10.6 kg per sq cm 100 mm dia dial 3/8" threaded type with stop cock arrangement.
Dismantling the existing old Vacuum gauge from the pump set/water supply line and provision of new pressure guage 0-760 mm Hg pressure 100 mm dia dial 3/8" threaded type with stop cock arrangement.
Supply and Fix in replacement of new pump shaft as per existing size of the following capacity pump sets (Make Kirloskar) Less than / Equal to 7.5 HP Pump Set
Dismantaling the old shaft and performing the necessary work and remetalling the shaft as per existing size of the following capacity pump sets 7.5 HP Pump Set
Supply and fixed in replacement of starter contactor assembly of ML 1.5 Type Make L & T Cat No. SS91851.
M&L for applying one coat of painting with approved synthetic enamel paint to external surface of pipes of sizes 200mm / 150mm / 100mm / 80mm / 50mm dia and marking arrows indicating direct flow with approved enamel paint all as specified and as directed by the Engineer-in-Charge.
M & L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the sump suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:- Capacity of 5000 gallons at NTG/NLC
All as per item No. 57 above but for Capacity of 50000 gallons at Naval Detachment
Removing old unserviceable float valve from service tank supply and fix float valve with PVC body aluminium float rod, nylon float high presure type for the following size:- 20 mm bore
Repairs / Maintenance of centrifugal / monoblock pumpsets regularly/systematically including inspection, adjustment repairs by opening the pump set for carrying out the preventive maintenance and repair by checking the serviceability alignment of various spares, removing the unserviceable pump spares and replacing with new spare parts, components servicing, cleaning and overhauling the same by lubricating, replacement of gasket, refixing the same after servicing, testing the same for smooth running, replacing minor parts like Gland rope, bolts & nuts, packing, threading and replacing spares and matching inclusive etc all as specified and as directed by Engr-in-charge of the following capacities pump sets. Note : New spares shall be measured and paid separately. 15 to 25 HP any model & make
All as per item No.60 above but for 5 HP any model & make
M&L scraping the old paint by using wire brush and emery paper and preparation of the surface for painting the following pumpset's /control panel /suction and delivery pipe of the pump house with one coat of primer and two coat of synthetic enamel paint all as specified and directed at site of the following capacity including marking flow of water and MES NO all as per norms and all as specified and as directed 15 to 25 HP Pump set
All as per item No. 62 above but for 5 HP to 10 HP Pump set
Disconnect the electrical connection,Lifting the submersible pumpset with 50mm GI pipe from 500 to 700 feet depth bore well up to 7.5 HP capacity and dismantling the pump set and rewinding the submerssible motor with super enamelled copper wire of suitable gauge replacing the damaged impeller, bearing, bushes, stainer as per exisiting size and assembiling the same including necessary lathe works, fixing the motor and proper insulation ,connecting and testing with apply one coat of primer and two coat of synthetic enamel paint and lowering the same and testing and commissioning all as directed at specified by the Engr-in-charge
Taking down carefully electric driven centrifugal / Monoblock pump 5 to 25 HP from foundation/ MS channel after disconnecting suction/ delivery lines/main electric supply from motor starter panel for replacement of ball bearing -02 Nos as per existing size at site / nearest repairing workshop including bring back and reassembling the same complete all as directed by Engr-in-charge.
Supply only starter contactor of ML 1.5 Type Make L & T Cat No. SS91851 or its equivalent in C&S / Standard
Supply only starter contactor of ML 2 W Type Make L & T Cat No. CS96005LOOO or its equivalent in C&S / Standard
Supply only starter relay of ML 2 /3Type Make L&T Cat No. SS91859OOCO / SS91859OOEO or its equivalent in C&S / Standard
Supply only standard operating coil for ML 1.5 Type Make L & T Cat No. SS90873POOO or its equivalent in C&S / Standard
Taking out the existing unsv submersible panel, supply & fixing of new accessories like starter single phase preventor, fuse cut outs, indicating lamp, coil, terminal block etc suitable for 5/7.5 HP, submersible pump set for outdoor application. Note :- Job includes necessary civil works such as foundation, grounding of panel etc & connecting back existing old cables.
S&F in replacement of Electronic Timers ST 100 operating range of 160V to 500V make L & T cat No. ST80328OOOO / ST80329OOOO as required
S&F new pump shaft as per existing size of the following capacity pump sets 25 HP Pump set
All as per item No. 72 above but for 5 HP Pump Set
S&F new rubber CI coupling set suitable 15 to 25 HP for centrifugal pumping set including key, lock, stud etc complete all accessories as existing size of the following capacity pump sets.
S&L in replacement flat 3 core submersible copper cable of size 6 sqmm
S&F in replacement of GI pipe heavy duty 50 mm dia with heavy duty socket for column pipe for bore well. Make : Jindal / TATA
S&F in replacement of Voltmeter (0-500 V) / Ammeter (0-400A) suitable capacity of CTs. (Make Meco/AE).
S&F in replacement of LED indication lamps from LT panels of colours Red, Green and Yellow.
S&F in replacement of Air Release Valve of existing size suitable for centrifugal pump set or directed by Engr-in-Charge
Removing of unserviceable foot valve from tank and replacement with new CI foot valve of following sizes:- 100 mm dia bore
All as per item No. 80 above but for 80 mm dia bore
All as per item No. 80 above but for 50 mm dia bore
Taking out old unserviceable foot valve from UG sump and removing unserviceable leather from suction line and replacement the same with high quality leather including nuts, bolts, washer etc and servicing for the following sizes:-. 100 mm bore
All as per item No. 83 above but for 80 mm bore
M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the UG sump suitable to store potable drinking water incl one coat white washing inside and marking outside sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:- Capacity of 5000 gallons at CQAL
All as per item No. 85 above but for Capacity of 100000 gallons at DGQA Res Accn (Gunatha vihar)
All as per item No. 85 above but for Capacity of 15000 gallons at DIQA
M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the OH reservoir of any staging suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of Tank, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following overhead reservoirs including staging:- Capacity of 1000 gallons at CQAL
All as per item No. 88 above but for Capacity of 100000 gallons at DGQA Res Accn (Gunatha vihar)
M&L for mechnical joint with nuts and bolts of the following sizes CI/DI pipes:- 200 mm dia bore
All as per item No. 90 above but for 150 mm dia bore
All as per item No. 90 above but for 100 mm dia bore
All as per item No. 90 above but for 80 mm dia bore
S&F PVC copper cable of size 2.5 Sqmm 3 core round / Flat type.
Supply and install 15 W avaiation lights of LED Based all as specified and directed by Engr-in-Charge.
S&F in replacement of non return valve flanged and threaded type including complete fixing accessories like nuts, bolts, packing etc of following sizes:- 100 mm dia bore
All as per item No. 96 above but for 80 mm dia bore
S & F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insortion packing 6mm thick etc of following sizes:- 200 mm dia bore
All as per item No. 98 above but for 150 mm dia bore
Vasavi Electricals (BID ID -3169489)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .