| 1 | L1₹2.0 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Accepted-AOC work order has been awarded |
Tender Value
₹2.6 L
EMD Value
₹5,215
Closing Date
29 Jan 2024, 1:00 pmClosed
EEE-I/SSZ
MUNICIPAL CORPORATION OF DELH Office of the Executive Engineer (Elect)-I Room No.5 First Floor Vishwakarma Nagar Near Hanuman MandirJhilmil Colony Delhi-110095
Provision of E.I and Fans at Dhobi Ghat pandav Nagar in ward No.16-E/200 (AC-58) under Shahdara South Zone
2024_MCD_182711_1
EEE-I/SSZ/2023-24/23.2
Open Tender
Electrical Works
Item Rate
120 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹5,215
29 Jan 2025
23 Jan 2024
31 Jan 2024
23 Jan 2024
29 Jan 2024
23 Jan 2024
Amount
DSR-2022 &Approved Rate
OD19959/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD19967/2023-2024:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD19990/2023-2024:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
OD19991/2023-2024:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
OD20422/2023-2024:1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
OD19994/2023-2024:1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
OD19995/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.1 6 way , Double door
OD19996/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(2.3.3) 12 way , Double door
OD19997/2023-2024:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
OD19998/2023-2024:Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40 A
OD19999/2023-2024:Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.1 25 A
OD20009/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD20001/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep
OD20003/2023-2024:1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
OD20004/2023-2024:PROVIDING AND FIXING CIRCULAR/ HEXAGONAL G.I. BOX FOR CEILING FAN CLAMP, OF INTERNAL DIA 140 MM, 73 MM HEIGHT, TOP LID OF 1.5 MM THICK G.I. SHEET WITH ITS TOP SURFACE HACKED FOR PROPER BONDING, TOP LID SHALL BE SCREWED INTO THE G.I. BOX BY MEANS OF 3.3 MM DIA ROUND HEADED SCREWS, ONE LOCK AT THE CORNERS. CLAMP SHALL BE MADE OF 12 MM DIA M.S. BAR BENT TO SHAPE AS PER STANDARD DRAWING. (DSR Civil-2014 item no. 10.18)
OD20006/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle)
OD20007/2023-2024:Earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as required.
OD20008/2023-2024:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
Bidder Name
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .