Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.9 L+₹4.7 L (18.7%)Rejected-AOC 2ND 14 RAGHAVS APARTMENT NORTH AVENUE SRINAGAR COLONY SAIDAPET CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L2 | Rejected-AOC Accepted |
Tender Value
₹30.5 L
EMD Value
₹29,652
Closing Date
20 Apr 2023, 3:00 pmClosed
SE Electrical
Electrical Department Amma Maaligai 4th floor b Block Greater Chennai Corporation Ripon Building
Supply and installation of CCTV Cameras with related accessories in various areas of Cooum river banks
2023_CoC_299325_1
EL.D.C.NO.A.E.E/TECH/1940/2023
Open Tender
Miscellaneous Works
Works
1095 days
Chennai
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹29,652
SE Electrical
15 Jun 2023
4 Apr 2023
21 Apr 2023
4 Apr 2023
20 Apr 2023
5 Apr 2023
5 Apr 2023 - 17 Apr 2023
6 Apr 2023
Supply and installation of CCTV Cameras with related accessories in various areas of Cooum river banks
7 Mtr Post – 7 Mtr long street lamp GI pole of size 88.9mm OD X 4.05 mm thick with 150mm X 150 mm square X 6 mm thick base plate, earth coil, earth bolt, nut and washer is required
Erection of 7 Mtr Post – Erection & materials required for 7mtr street lamp pole (Conventional Erection)
5 MP camera motorized - 5MP IR Vari-focal Bullet Network Camera, 5MP, 1/2.7” CMOS image sensor, low luminance, high image definition · Outputs 2688×1520 (2688×1520) @ 25/30 fps, to support max. 5MP (2592×1944) @ 20 fps · H.265 codec, high compression rate, ultra-low bit rate · Built-in IR LED, max IR distance: 60 m · ROI, SMART H.264/H.265, flexible coding, applicable to various bandwidth and storage environments · Rotation mode, WDR, 3D DNR, HLC, BLC, digital watermarking, applicable to various monitoring scenes · Intelligent detection: Intrusion, tripwire. · Abnormality detection: Motion detection, video tampering, no SD card, SD card full, SD card error, network disconnected, IP conflict, illegal access, voltage detection · Supports max. 256 GB Micro SD card · 12V DC/PoE power support · IP67 protection is required.
128 GB SD Card – To support 5 MP camera motorized, micro SDXC memory card with full size adapter, 100MB/s or equivalent required
Internet Box – Dimension size of powder coated, pole mount rack should be with suitable Height, Width and Depth for 4G router and power strip should be connected.
4G Router - Required and to support 4G LTE Router, Connectivity -Wi-Fi, Ethernet, Power -DC 12V 1A, LED indicator -Power & LTE, Operating Temperature (-25°C to 60°C), Compatibility -All SIM Cards, Speed - Min. 150Mbps
Connecting Cable – Cat- 6 patch cord, Hi- speed Gigabit up to 1000 Mbps, waterproof and durable is required.
EB Box – Dimension size of powder coated EB box should be Height – 10” Width –15” Depth - 6”, inside the a single phase, energy meter, fuse carrier, MCB should be fixed in the ilam Sheet. Dedicated lock with key shall be provided.Gauge-16
Power Strip - Power Strip 3 Pin 5A & 4 Socket with surge Protector
2 Core Cable (16 Loc ) – I.S.I Marked 2X16 SQ. MM Cable
HDPE Pipe (16 Loc ) – Size 50 MM O. D X 38 MM I.D
Cable Laying (16 Loc ) – Laying of cable along road/ Street through 50mm OD, H.D.P.E pipe (Trench size 45 cm width X 75 cm depth)
Road Cross Cable Laying (16 Loc ) - Laying of cable up to 120 SQ MM in road crossing through 4” DIA HUME Pipe
Solar panel for Power – Required Power - 150W, Power Tolerance - (+ve Tolarance), Open Circuit Voltage Voc in Volts - 22.50V, Short Circuit Current in Amps - 9.22A, Voltage at Max. Power in Volts - 18.95V, Current at Max. Power in Amps - 8.72A, Solar Cells per Module - 36/(9*4), Solar Cell type - Multi Crystaline Silicon, Front Cover - Tempered Low Iron Glass/min 3.2mm thickness, Encapsulate - Ethylene vinyl Acitate, Frame Material - Anodized Aluminium Alloy, Junction Box - IP67,4-rail,3 Diodes,1Mtr 4 Sq.mm copper wire, with MC4 Connector, Dimension –not exceeding 500/675/40 (L/W/T)mm, Battery - 12.8V 60AH Lithium ferro phosphate battery, Charger Controller - Compatible for 150W Panel
Solar Fixing Bracket - G.I bracket should be fixed at the top of the post and it should be suitable for the solar panel, angle tilt with orientation is required and adjustable brackets along with the suitable nuts and bolts are required to fix.
Charges towards Software installation, Testing, configuration, implementation of control room and project management
O&M Charges ( 3 Years ) – For all the Materials
Universys Technologies Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .