Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.3 L+₹1.1 L (6.78%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹17.5 L+₹1.4 L (8.48%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹19.3 L+₹3.1 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical The Firm is not having a i cat |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Apr 2024, 6:00 pmClosed
GE HISAR
GE HISAR
CA NO GE(H)-72/2023-24 UPKEEPING OF POWER HOUSE OUTDOOR SUBSTATIONS UNDER GE HISAR AT HISAR MIL STN
2024_MES_638145_2
CA No GE(H)-72/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hisar
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹40,000
Yes
24 Jun 2024
16 Mar 2024
17 Apr 2024
16 Mar 2024
15 Apr 2024
1 Apr 2024
Amount
S&F 4 mm dia MS wire 75x75mm mesh, made upto into mattress or cages appx 2.0 mtr height and fixed with flate iron/angle by welding in position and directed including complete all as specified and directed. Note:- MS angle, MS flate, Nuts, Bolts and washer will be measured and paid sepretly.
M & L for two coats of synthetic enamel paint of Aluminiumor silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.
M&L for Steel work in tubular trusses, MS work of angles for post and struts of fencing around transformer plinth etc drilling holes, flate iron fillet for securing wire mess by welding to angle iron frame and framed work as in door/ gate of angle and wire mess. Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified including dismantling of old unserviciable MS work.
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth (without using extra cement)
M&L Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:4 complete as specified and directed including dismantling of old unservicable brick work.
M&L for PCC (1:4:8) type D-2 using 40 mm crushed graded stone aggregate as in for pole foundations etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc for poles complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc for poles complete all as specified and directed.
Dismantling unserviceable any type pole/struts of any size removing from site etc complete all as specified and directed.
Supply, erecting & fixing true vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) complete all as specified and directed.Make:- M/S Jindal steel products, National tubing Co, Anil Engineering Corporation Note :- (i) The rates quoted shall deemed to include taking out conductors, earth wire from existing pole and refixing on new pole. (ii) Earth work & PCC shall be measured and paid separately in respective items.
M&L for construction of plate form with PCC Block masonry Masonry platform of size 3m x 3m x 1.2 m hight , PCC(1:3:6) type C1 using 20mm graded stone aggregate built in CM 1:4 complete with and including necessary excavation & earth work , PCC 1:4:8 type D-2 as in foundation , rendering 15 mm thick rendering in CM 1:6 on sides and top of the brick work , upto 300 mm below ground level , supply and fixing of 02 Nos MS Chennels of size MC 100 for balancing of Transformer embedded in PCC (1:2:4) type B-1 , top surface of plateform shall be provided with 100 mm Thick RCC (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 10 mm steel TMT bar , including provn of steps in one side of plateform and all the outer face of platform shall be given with two coat of white wash, complete all as specified and directed .
Material and labour for sprading of stone aggregate of nominal size not more than 63/40mm under 4 pole HT structure /surounding area of manually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformaly in layersn and rammed to true surface all as specified and directed
S&F in replacement post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed. Make: Crompton Cat Part No. CBP-610-40-57-SL-CA-NBK, Surya Cat No SLE PT 40W ETPP, Jaquar Cat No LGTP06X040XN,
S&F in replacement LED flood light fitting of cap 70W (or nearest higher Cap), 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. Make: Crompton Cat Part No. TFS-504-70-57-60D-HL2-GL-NSG, Surya Cat No SLE FL 80W IP66 LMS NEO, Jaquar Cat No LFLDSLM070XC, Havells Cat Part No. JETANEOFL70WLED757LTG, WIPRO Cat Part No. LF20-102-060-57-G2
S&F in replacement PVC junction box suitable for street light of size not less than 350mm x 250mm x 150mm, made out of polycarbonate having front side openable shutter duly provided with locking arrangement and provided with 04 Nos aluminium bus bar of rating 200 Amp alongwith 01 No MCB 6 Amp SP and provision of 02 Nos cable entries of size upto 16 sqmm 4 core, fixed on any type of street light pole with proper size MS clamp with nut & bolt and connected assessories complete all as specified and directed. Make:- SINTEX, HENSEL, NAPTUNE
M/L for Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.
M/L for cement concrete type B-2, 1:2:4 (40mm graded aggregate) 150mm thick complete all as specified and as directed.
M & L for duct cover Mild steel plates, chequered, 5mm thick in Fe 410-W (Gde-E-250) quality-A with welding including lifting arengment of duct cover complet all as specified and directed by Engineer in cgharge including taking out and existing earthing.
Supplying and laying as replacement in sub station fixing 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables with aluminium conductor 1100 volts grade 4 core 16 sqmm
All as per Sl Item No. 20.00 above but of size 10 Sqmm, 4 core.
Supply laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
Supply and fix cable jointing kit for 11 KV grade cable (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm Make:- Densons, M-seal, Raychems ,
Supply and fix cable jointing kit for 11 KV grade cable (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm Make:- Densons, M-seal Raychems ,
M&L Earthing complete with galvanised iron electrode of size 600mm x 600 mm x 6 mm, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing strip 25 x 4mm galvanised iron strip all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion including necessary excavation in any type of soil, returning filling, removing of soil and 1.5 mtr length GI medium grade 20mm dia pipe with funnal and wire mesh, PCC chamber of 1:2:4 type B1 using 20 mm grade stone aggregate, 40 mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways pre cast chamber cover with lifiting handle 16mm dia round bars, Gi pipe medium grade 40 mm dia for earth strip protaction including charcol, common salt complete all as specified and directed. (Note:- GI earth strip above to 7.5 mtr long shall be measured and paid separetly)
Supply and fixing in replacement of galvanised iron strip 25x4mm mm buried in ground for additional earthing lead beyond 7.5 meter if required.
Excavation in trenches, not exc 1.5m wide and n exc 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in any type of soil.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed
M&L for Boring holes horizontally under road crossing manually for crossing of GI pipe/HT/LT cable etc up to 200 mm bore all as directed.
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size 40 mm dia Make:- Jindal, Tata, Surya prakash
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size 100 mm dia Make:- Jindal, Tata, Surya prakash
S&F in replacement FRLS PVC insulated and PVC sheathed 1.5 sqmm 3 core multistranded copper conductor cable from for street light including PVC wire connectors for making connection complete all as specified and directed.
Material and labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Re adjustment, cleaning of contact, greasing and testing of out door type air break switch 11 KV current rating upto 400 Amps including all materials required for alignment for AB switch in position and replacement of unserviceable parts Note : Replacement of unserviceable parts shall be measured and paid separately under relevant items.
Material and labour in replacement Retro Reflective installation sign boards of size 4 feet x 3 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS pipe of size 25mm bore at height 2.00 meter above ground level on stainless steel heavy duty pipe of size 50mm bore embaded 60 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx60cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter will be in English language on both sides with reflective adhesive painter tapes as directed by Engineer -in-charge.
Shifting of transformer from 2/4 pole structure to plinth, Isolating 11 KV HT supply from the substation and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, disconnecting removing taking down out door transformer of capacity upto 400 KVA from 2/4 pole structure and refixing, installing, commissioning & testing the transformer on plinth complete all as specified directed by Engineer -in-charge. Note:- (a) The rates quoted is deemed to be included for hydra, T&P and man power and other items required for sifting of transformer. (b) Plinth work shall measured and paid separetely under items of sch of work here-in-after.
Supply and Fixing in replacement Alunimium composite panel sheet (Alco panel sheet) of thickness not less than 6 mm the fornt side being PVDF coated provides excellent colour retention, gloss retention, UV stability and pollution resisteance with negligible periodic maintenance , stain resistance, durability and environment friendliness including The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape, including wiriting matter will be in English language on both sides with reflective adhesive painter tapes as directed by Engineer -in-charge
fauji electric works
YASHU CONTRACTORS
M/S KAVITA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .