Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.1 L+₹91,380 (3.49%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹32.4 L+₹6.2 L (23.8%)Rejected-Finance INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹32.6 L+₹6.4 L (24.5%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹33.1 L+₹6.9 L (26.3%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹39.5 L
EMD Value
₹78,920
Closing Date
18 Nov 2024, 6:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
SPECIAL REPAIRS FOR REPLACEMENT OF LT DISTRIBUTION PANEL AT VARIOUS LOCATION OF OFFICERS RESIDENTIAL AREAS AND ASSOCIATED AREAS AT NAVAL BASE KARWAR
2024_MES_681326_1
8217/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SB) KARWAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SB) KARWAR
₹78,920
Yes
4 Jan 2025
25 Oct 2024
20 Nov 2024
25 Oct 2024
18 Nov 2024
11 Nov 2024
25 Oct 2024 - 8 Nov 2024
Amount
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp of Make:Schneider/L&T/ GE/Siemens – 14 Nos (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 2 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge.
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp of Make:Schneider/L&T/ GE/Siemens – 5 Nos (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 6 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge.
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp of Make:Schneider/L&T/ GE/Siemens – 3 Nos (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 13 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge.
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 100 amp of Make:Schneider/L&T/ GE/Siemens – 4 Nos (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 18 Nos (iii) Three phaseTimer switch with suitable cap of contactor controlled by existing 63 amp MCCB, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge.
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 100 amp of Make:Schneider/L&T/ GE/Siemens – 1 No (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 10 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Excavation of existing cable of size 25 Sq mm to 240 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3167965)
BRO TECH ELECTRICAL & ENGINEERING SOLUTION (BID ID -3167969)
M/S MANOJKUMAR M NAGARKATTE (BID ID -3166512)
HARSHITA MARINE SERVICES (BID ID -3166053)
LEKSHMI ENGINEERS (BID ID -3166564)
K.G.SHANKER (BID ID -3167907)
Shivam combines (BID ID -3167399)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .