| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.3 L+₹1.3 L (5.08%)Rejected-Finance LINE PAR NAI BASTI OSARH ROAD FARIDPUR DISTT BAREILLY PIN 243503 | FARIDPUR | BAREILLY | BAREILLY | 243503 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹30.6 L+₹4.6 L (17.9%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L3 | Rejected-Finance Not being L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR AJIT CHOUDHARY
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
WELCOME MAINTENANCE INCLUDING MISC REPAIR FOR E/M WORK TO CERTAIN OMQ,S AND SMQ AREA IN DOMESTIC AREA AT AFS KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2023_MES_595370_1
C/8867/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹70,000
Yes
4 Jul 2023
13 May 2023
15 Jun 2023
13 May 2023
14 Jun 2023
27 May 2023
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
All as per item No. 2 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
All as per item No. 2 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch complete all as specified and directed.
All as per item No. 2 here-in-before, but for bell buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm. complete all as specified and directed.
All as per item NO.2 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
All as per item No.2 here -in- before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete but excluding sunken box and hylam sheet all as specified and directed. .
S&F point wiring with 1.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010 , ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as per existing specification without any extra cost
One light/Fan point controlled by one 5 Amps switch one way complete
One bell point controlled by one 5 Amp bell push complete
One 3 pin 5 amp switch socket combination point on independent board with other switches.
One 3 pin 5A switch socket combination point on same board with other switch.
All as per item 8.00 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable as per IS 694: 2010 for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
All as per item 8.00 here in before but power point wiring with 4.0 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010, ISI marked , PVC insulated unsheathed cable & including PVC casing caping of 25 mm wide , including all accessories casing caping complete with PVC 4.0 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point.complete all as specified and directed by EIC.
S&F Point wiring with 1.5 Sqmm single core,FRLSH multi stranded copper conductor,as per IS 694: 2010, 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, excluding sunken box , laminated hylum sheet cover but including PVC box for mounting of fittings like switches, sockets, fan regulators etc complete all as specified and directed by EIC. Note :(i) Wiring to be done as per approved colour code.
One 3 pin 5 Amps switch socket combination point controlled by one switch on independent board.
All as per item 9.00 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable as per IS 694: 2010 for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
M & L Point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core,FRLSH cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, as per IS 694: 2010 ISI marked, drawn in existing concealed/ surface conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLSH cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including new laminated bakelite sheet cover of min 2.8 mm thick , ISI marked of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer. complete all as specified and directed by EIC. for the following. Note : (i) Wiring to be done as per arroved colour code.
(a) One light/fan point controlled by one switch.
(b) One bell point controlled by one bell Push
(c) One 5 Amps socket out let point controlled by one switch on independent board.
(d) All as per item 11 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
(e) All as per item 11 here in before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
S&F switch piano flush type single pole,5 Amp. AC, 230 V one way complete all as specified and directed by EIC. (Note : Item to be measured if execuated under new point wiring)
S&F in repair switch piano flush type single pole,5 Amp. AC, 230 V one way complete all as specified and directed by EIC.
S&F Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring) .
S&F in repair Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.
S&F bell push flush type single pole one way, 5 Amp, AC,230V complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair bell push flush type single pole one way, 5 Amp, AC,230 V complete all as specified and directed by EIC.
S&F switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose including taking out old u/s complete all as specified and directed by EIC.
S&F Bell ,Ding dong type electric AC, 230V, Single phase,complete all as directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair Bell ,Ding dong type electric AC, 230V, Single phase, complete all as specified and directed by EIC.
S&F ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.
S&F in repair switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 230 volts controlled by one switch, flush type including PVC mouting box complete all as specified and directed by EIC. Make : Anchor Penta , Cat No. 39593 or equivalent of make: CK Birla Group (Orient Electric) /L&T or as per PS
S&F LED tube lamp 18 Watt (reterofit type, T8 pattern, single/double side connection) LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1800, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ATHD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete fitting to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting including taking down old unserviceable complete..Make : Bajaj Cat No. BLRB 20W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivalent in WIPRO /PHILIPS/ CK Birla Group (Orient Electric) as approved by GE.
S&F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 20W CW LED (retrofit LED tube lamp 20 Watt, Single end connection) or equivalent in Wipro/Philips/ CK Birla Group (Orient Electric) as approved by GE complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
S&F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 20W CW LED (retrofit LED tube lamp 20 Watt, Single end connection) or equivalent in Wipro/Philips/ CK Birla Group (Orient Electric) as approved by GE complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
S&F in repair LED lamp 18 Watt 4 Pin type, colour Temp 6500K, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1800 Lumen efficacy of minimum 110 lumens per watt, with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, available CCT of 6500K, life span of minimum 50000 working hoursretrofit type in existing fitting with necessary change in wiring complete all as specified and directed Make: Bajaj/Philips/Wipro.
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.. (Note : Item to be measured if execuated under new point wiring)
S & F in repair LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.
S&F LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj/ /Wipro/Philips as approved by GE
S&F in repair LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ATHD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj/ /Wipro/Philips as approved by GE
S & F LED street lights nominal power 25 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-291-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repair LED street lights nominal power 25 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No.Bajaj Cat Part No. BCLST25 W LED IV2 or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed. .
S&F for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in including PVC casing caping not less than 32 mm width ISI marked double locking type including one including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed by EIC.
S&F for Sub main wiring with Four run of single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in with and including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping including one run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed by EIC. ( 4 x 6.0 sqmm + 1 x 6.0 Sqmm earth wire).
S&F for Sub main wiring with Four run of single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC casing capping not less than 38 mm ISI marked including all accessories of casing caping including one run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed by EIC. ( 4 x 10.0 sqmm + 1 x 10.0 Sqmm earth wire).
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription complete all as specified and directed .
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door with 100 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 100 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 160 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Hager Cat Part No. VYV06DM-P160 Model : P160 h3+ and 100 A MCCB, TP, 25 kA , Cat No.HHS100DR or equivalent of make: ABB/Legrand. Note : (i) MCCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with prov of MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand/ Seimens/ Schinder/Hager/ABB
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make - Hager Cat Part No. VYV04DM-P and 63 A MCCB, TP, 25 kA , Cat No.HHS063DR Model: or equivalent of make: ABB/Legrand.
S & F sheet metal enclosure MCB, DB, SPN, 240 Volts, 100 Amps rated copper busbar, Confirming to IS as per IEC 61439-3, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .Make- Legrand/ Seimens/ Schinder/Hager.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 complete all as specified and directed by Engr-in-charge. ( Note: DB and MCCB/MCB shall be of same make)
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 6A to 32 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), three pole with one protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 40 to 100 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), three pole (TP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 25A to 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.Make- Legrand/ Seimens/ Schinder/Hager. Note: DB and MCCB/MCB shall be of same make.
S&F in repairs laminated hylam sheet cover, ISI marked, cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer including taking down u/s complete all as specified and directed by EIC of following sizes.
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
S&F stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed by Engr-in- charge. (Note : Item to be measured if executed under new point wiring)
S&F in repair of stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed by EIC.
S&F for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil/stone ,disposal of soil , providing alternate layers of charcoal and common salt, refilling of pit with agriculture soil, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion,including taking out old u/s complete all as specified and directed. (Note: (i) Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) (ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit.
S&F galvanised steel tubing light grade 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with including G I clamps including taking down old unservieable complete all as specified and directed by Engr -in- charge
S&F for earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer including taking down old unservieable complete all as specified and directed by Engr- In- charge
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking out old u/s all as specified and directed by Engineer in charge.
Supply and Fix in repairs, Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Bell switch , 6 Amps, 1 Module, complete all as specified and directed.
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings all as specified and directed by Engr- in - Charge.
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed by Engr- in - Charge.
S&F in repair of stepped type Modular electronic fan regulator 2 module , 120 watt on the existing hylam laminated sheet etc as required complete all as specified and directed by Engr- in - Charge..
Supply and Fix in repairs, Modular Fan step regulator, 100W - 1 module,complete all as specified and directed.
S&F in repair Modular metal flush box of 1/2 module including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 3 module including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 4 module including taking out u/s including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 6 module including taking out u/s including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 1 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 2 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 3 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 4 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 6 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 8 Module complete all as specified and directed by EIC.
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4000, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC. Make Bajaj/Philips/CK Birla Group (Orient Electric)
S&F for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by EIC.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 10-60 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) including taking out old u/s complete all as specified and directed by EIC Make : Secure (Model Saral) or eqivelent of make: L&T Note : Old u/s meter to be deposite in AGE E/M store.
S&F Polycarbonate angular lamp holder with back plate, suitable for LED Lamp fittings all as specified and directed by EIC including taking out old u/s.(Note : Item to be measured if executed under new point wiring)
S&F in repair Polycarbonate angular lamp holder with back plate, suitable for LED Lamp fittings including taking out old u/s complete all as specified and directed by EIC
S & F LED downlight recess mounted nominal power 6 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 500, lumen efficacy of minimum 90 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die cast aluminium housing and ring, life span of minimum 50000 working hours complete all as specified and as directed.
S & F LED downlight recess mounted nominal power 12 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1080, lumen efficacy of minimum 90 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die cast aluminium housing and ring, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fix Round highway LED light 120 watt with PDC housing, 240 v, PF > 0.90, colour Temp 6500 K,IP66, System Luminious efficacy >110Lm/W, , make: Crompton cat part No.LBH11-120-CDL/60M or equivalent of make : Bajaj/CK Birla Group (Orient Electric).
S&F LED bulb 9/10 watt with B22 base, 1100 lumen, 6500 K complete all as specified and directed by EIC. Make : :Wipro/Philips/Bajaj/CK Birla Group (Orient Electric) .(Note : Item to be measured if executed under new point wiring)
S&F in repair LED bulb 9/10 watt with B22 base, 1100 lumen, 6500 K including taking out old unserviceable complete all as specified and directed by EIC. Make : Make : :Wipro/Philips/Bajaj/CK Birla Group (Orient Electric)
Taking down existing panel light fitting any type (300 mm x 300 mm) recess mounting/surface and S&F LED light fitting 18 watt recess mounting of size 300 mm x 300 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC. Make Bajaj/Philips/CK Birla Group (Orient Electric)
S&F for repairing / replacement of old rusted sunken box after removing hylam plate and providing new MS /GI suncken box flush in wall including taking out old unserviceable complete all as specified and directed by EIC including fixing of hylam sheet and making good of surface to match with existing for following size of boxes.
5 x 5 inchs
5x8 inchs
11 x 9 inchs
Supply and fixing in repair PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed by Engr-in-charge. Make :Havells Cat No.WHMFDSKB32X5 or equivalent of make as per PS
M/S OM BUILDERS
SUMAN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .