Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC SANTOBI MATA GALI MURSAN HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | L1 | Accepted-AOC Accept | |
| 2 | L2₹5.0 L+₹3.0 L (151.3%)Rejected-AOC | L2 | Rejected-AOC Accept | |
| 3 | L3₹5.1 L+₹3.1 L (154.7%)Rejected-AOC 13 138 SHAKTINAGAR SHUKLAGANJ UNNAO | UNNAO | UTTAR PRADESH | 209801 | L3 | Rejected-AOC Accept | |
| 4 | L4₹5.4 L+₹3.4 L (171.2%)Rejected-AOC | L4 | Rejected-AOC Accept |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
17 Jul 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC Hathras
SE EDC Hathras
Work
2020_DVVNL_490614_1
EDCH-32/2020-21
Open Tender
Electrical Works
Item Rate
45 days
SE EDC Hathras
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DVVNL
₹5,000
18 Dec 2020
8 Jul 2020
17 Jul 2020
8 Jul 2020
17 Jul 2020
8 Jul 2020
30 days
Amount
Carriage of following from 132 KV Hathras store center to 33/11 KV Substations through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50 Kms.)
8.5 Mtr. PCC Poles
9/11 Mtr. S.T. Poles
11 KV piller Proof Metering Cubicle
11 KV Pole Mounting Unit
11 KV XLPE Cable
11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps Abc Bunch and other required line material, if any.
Carriage of following from 132 KV Store center Hathras to 33/11 KV Substations through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.)
250 KVA T/F
Erection of following Poles including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
8.5 Mtr. PCC Poles
STP (SP-33) 9.0/11 Mtr.
Double pole complet fitting
Erection and grouting of stays as per RESPO manual and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of 3*70 Jointing Kit ID/OD
11 KV Fixing piller Proof Metering Cubicle
11 KV Fixing Pole Mounting Unit
LT Piller Box
Fixing DLMS Meeter
GI Pipe 6' Dia
Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer.
Fixing of following accessories.
11 KV Disc Insulator with fitting.
11 KV Pin with insulator
11 KV X-Arm
F Clamp
11 kV TPMO
11 kV Fuse Set
Dropper Channal/Top Channel
Holding Clamp With N & B
Providing & Fixing Danger Board
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR Weasal conductor
LT Cable
ACSR Dog Cunductor
11 KV XLPE Cable
3x120+1x16 sqmm AB Cable
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
Installation of following T/F on newly constructed double pole in proper alignment direction & making HT/LT connection.
250 KVA T/F
Fixing 3 Phase LT Distribution Box with holding Clamp
Installation of extra ''T'' on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc, required for proper completion of work. The "T" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material.
Providing & Fixing Number Plate
Construction of new plinth of size 5' * 5 * 4' above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Cemical earthing of medium Power Transformers
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
DIVYANSHU ENGINEERING AND CO
MAA DURGA CONSTRUCTION
CHAUHAN ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .