| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.1 Cr | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹1.2 Cr+₹8.4 L (7.26%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | ₹1.2 Cr+₹8.4 L (7.26%) | L2 | Rejected-Finance Higher Rate |
| 3 | L3₹1.5 Cr+₹31.1 L (27.0%)Rejected-Finance VILL RANITALA P O JIBANPUR P S RANITALA DIST MURSHIDABAD | MURSHIDABAD | WEST BENGAL | ₹1.5 Cr+₹31.1 L (27.0%) | L3 | Rejected-Finance Higher Rate |
| 4 | L4₹1.5 Cr+₹32.5 L (28.2%)Rejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹1.5 Cr+₹32.5 L (28.2%) | L4 | Rejected-Finance Highest Rate |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
20 Apr 2019, 2:00 pmClosed
SE,HEC,PWD
SUPERINTENDING ENGINEER (P.W.D) Health Electrical Circle KIT Annex Building, 5th FLOOR, KOLKATA 700073
SITC of Fire Detection and Alarm system at Dr BC Roy Lecture Theatre SLT, Dr Subhash Mukherjee Bldg, Forensic Medicine Bldg., UNB Building, Microbiology Bldg, and Radiotherapy Building at NRS Medical College and Hospital Campus, Kolkata.
2019_WBPWD_223129_1
WBPWD/SEHEC/CKHED/NIQ70/18-19
Open Tender
ELECTRICAL WORKS ORG
Item Rate
130 days
Nil Ratan Sircar Medical College
Please refer Tender documents.
4 documents required · 4 mandatory
₹2.6 L
Office of the SE,HEC,PWD
6 Jan 2021
8 Mar 2019
22 Apr 2019
9 Mar 2019
20 Apr 2019
19 Mar 2019
14 Mar 2019
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, soft addressable, ( VDS / UL / FM / ULC approved ), ethernet ready fire alarm control panel, with each loop capable of taking minimum 120 devices. The panel shall be able to give pin point location of all fire/ fault conditions. The Panel should be able to store minimum 1000 log events in its Memory as per recommended standards.
The panel shall have in-built rectifier, Loop cards, interface card for connecting external serial printer, 4 line, 40 charecter/line alphanumeric LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working or capable of operating the system for 2 hours during alarm condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked with other similar FACP located at different part of the premises through ethernet (LAN). The panel should have necessary Ethernet card installed in it for bidirectional communication with 3rd party BMS/Scada and 3rd party public address system. All necessary memory map (incl. device address) should be provided. Minimum 4 potential free spare contacts should be provided with the panel. The system must be preloaded with licenced software. ( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls / Securiton ).
2 Loops panel with one additional loop, expandable upto 4 Loops.
12 Loops panel.
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detectors sensor with decentralize intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard. [Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost].(Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls / Securiton)
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with inbuilt optical smoke sensors & heat detectors sensor with decentralize intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard. [Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost].(Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls/ Securiton )
Supplying, installation, testing and commissioning of soft Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard [Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for each addressable devices (Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost]. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Contros / Securiton )
Supply, Installation,Testing & Commisioning of soft Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo/ Morley / System Sensor / Johnson Controls / Securiton ).
Supply, Installation, Testing & Commissioning of soft Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base ( VDS / UL / FM / ULC approved) . (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls/ Securiton).
Supply, Installation, Testing & Commissioning of soft Addressable transponder/ Monitor Modules (1 in and 1 out) ( VDS / UL / FM / ULC approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. ( Approved Make: (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls/ Securiton).
Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS / UL & FM approved) for switching / integration of Lift / AHU etc complete as required.
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having red coloured LED lamps including connections etc.( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls/ Securiton ).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab / RR Kabel) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall.
Supply & Laying of 2 Core 2.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab / RR Kabel ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson/Polycab-Medium-FR) on the surface of the wall.
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
TESTS: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary building drawing/ floor plan with layout should be prepared and to be approved from the fire safety Cell of PWD according to the prevailing fire safety policy. After commissioning, necessary testing to be done in presence of fire safety cell.
The Agency must procure the materials from the Manufacturer/OEM or from their authorized sales channel so that the standard warranty/supprot of the Manufacturer/OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer/OEM or from their authorized sales channel and standard warranty/support should be sent from the e-mail of the Manufacturer/OEM/authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
GLYPTIC
S. K. CONSTRUCTION
ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .