| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 103 1A RAJA DINENDRA STREET KOLKATA 700 005 | KOLKATA | KOLKATA | WEST BENGAL | 700005 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.0 L+₹47,611 (7.26%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹7.5 L+₹89,658 (13.7%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | Rejected-Technical 123 2A AMHARST STREET KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | - | Rejected-Technical Not Eligible |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
20 Feb 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-I,WKED,PWDte.
New Secretariat Building, C Block, 4th floor 1, K.S Roy Road, Kolkata-700001
Renovation and repairing to Electrical Installation work in respect of reorganisation of the Old Account Section at Ground Floor Main Building of the Honble High Court , Calcutta.
2024_WBPWD_663450_1
WBPWD/EE-WKED/NIQ-78/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
High Court, Calcutta
Please refer Tender documents.
5 documents required · 5 mandatory
₹14,000
30 Jan 2025
8 Feb 2024
22 Feb 2024
8 Feb 2024
20 Feb 2024
8 Feb 2024
Amount
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14]
6 Way Enclosure [Make: Legrand Enclosure (607716) or equivalent model of Siemens/Crabtree/L&T as approved by E.I.C]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6]
(a) 100 Amp FP Isolator
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection(Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7]
(a) 6-32 Amps SP MCB
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. [E-24/1]
a) Avg. Run-10mtr ccc
b) Avg. Run-12mtr [E-24/1(g)]
c) On board [E-24/3(a)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1]
i)3 x 22/0.3 (1.5 sqmm) [ E-9/1(b)]
ii)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ E-9/1(s)]
iii)2 x 43/0.3 (4 sqmm) + 1 x 32/0.3 (2.5 sqmm) ECC [ E-9/1(s)]
iv)4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [E-9/1(d1)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-9]
i) 2.5sqmm [F-5/9(i)]
ii) 4 sqmm [F-5/9(ii)]
iii) 6 sqmm [F-5/9(iii)]
iv)10 sqmm [F-5/9(iv)]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1]
6 Module(E-17/1(b))
2 Row 12 Module [E-17/1(e)]
Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. [E-17/3(a)]
Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)]
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)]
Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.( E-17/F-5(a))
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. ( E-17/F-5(b))
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E-16 / 7)
a) 20 mm size
b) 25 mm size
Fixing only single /twin fluorescent light fitting complete with allaccessories directly on wall/ceiling/HW round block and suitablesize of MS fastener (C-2/14(b))
Supply of 4'ft LED Twin batten/Metal frame fittings incl. 2nos. 18W Polycarbonate/Aluminium LED tube having luminoius efficacy of 100lm/W [Philips/Crompton Greaves/ Wipro or manufacturer with own NABL accredited Lab with valid Test certificate as approved by E.I.C]
S&F 240V 18''(450 mm) Sweep heavy duty best quality AC Wall Bracket Full metal body Fan (Make : Orient/Crompton/Usha as approved by E.I.C) complete with all accessories incl. inter connection on wooden board on wall incl. S&F wooden board of suitable size as per direction of EIC
Dismantling chareges for existing electrical items incl. tube light/led light, fittings, switch boards ceiling/wall fans wires etc incl. mending good all damages as per GS and clearing/ removing from the site & keeping at safe place as per direction of EIC. per direction of EIC.
Supply & fixing Timer Control Unit for single phase Split type AC machine assembled with following accessories: - i)12-way double-door(Metal door) SPNDB Box (L & T cat no.-DBSPN012DD or equivalent model of Legrand/ Siemens as approved by E.I.C)-1 no. ii)25A DP 30mA RCCB (Make: L&T Cat no.-BG202503 or equivalent model of Legrand /Siemens ) - 1 no. iii)Digital 24 hour time switch (Make-L&T Cat no.-67DDT0 or equivalent model of GIC/Siemens) -1no. iv)25A 2-pole power contactor (L&T: Type- MU25 ; Cat no.-CS90118 or equivalent model of Siemens/ABB)-1no v) 6 amp auto mannual toggle switch (Make- L&T or equivalent make as approved by E.I.C) vi)LED indicating lamp (L&T: SIL R 240V)-1 no. vii) ON/OFF Push = 2 nos viii)2X4sq.mm+1x2.5sq.mm copper wire -4 mtr. ix)1.5sqmm copper wire-3 mtrs. x)8 Pin Relay 5Amp 2 Pole General Purpose Relay - MKG2P Plugin type enclosed version with LED Indication - With Mounting Base (220V)( make-Sulzer or equivalent model of Siemens/ABB) xi) S&F Thermal overload Relay(9-14A) (Make-L&T cat no.-CS90207OOVO or equivalent model of Siemens/ABB)- 1no. All control circuit wiring would be made by 1x1.5 sqmm FRLS stranded Cu wire(Brand approved by E.I.C) and the I/C & O/G circuit with 1x4sqmm copper wire of suitable length maintaining colour code incl taping, socketing to complete the work.
Supply & delivery of 240V split Air-conditioner machine having cooling capacity not less than 5000W, ISSER 3.8 to 4.39, BEE rating not less than 3 star, Noise level not more than 50db. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant-R32/R410A. (O-General/ Hitachi/ Daikin/ Mitsubhisi Electric/Mitsubhisi Heavy Industries as per approved by EIC/authority).
Installation, testing & commissioning of the above-said split Acs incl supply & fixing required angle iron structure on wall for placing outdoor unit & mending good the damages asper direction of E.I.C
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including wrapping tape,shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Supply & Laying of 4 core 1.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/Polycab as approved by E.I.C)
Supply &Laying 3/4"(20mm) hard PVC pipe(heavy type)for water drainage.
Supply and fixing of angle iron frame fabricated from 40X 40mm GI angle with support radially from the bottom including bent clamp on top with proper holes for fastening to rest the outdoor unit. The frame should be grouted properly with cement and sand in the wall with minimum 200 mm insertion into the wall including 06 Nos fasteners as per requirement of bearing load of outdoor unit.
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
S.R. REFRIGERATION AND APPLIANCES
UNIVERSAL SALES
technical_1437858.pdf
PDF • 0.07 MB
techsummary_1437858.pdf
PDF • 0.40 MB
finance_1437858.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1437858.pdf
PDF • 0.05 MB
finalAcceptance_NIQ78_2023-24_NationalAircon.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .