Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC H NO 114 A 10 GHAZI NAGAR RADDI CHOWKI GOHALPUR JABALPUR MP | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹59.6 L+₹36.1 L (153.3%)Rejected-Finance 2284 30 BAJRANG NAGAR VFJ ESTATE JABALPUR 482009 | JABALPUR | MADHYA PRADESH | 482009 | L2 | Rejected-Finance Highest amount quoted |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Sept 2024, 6:00 pmClosed
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
REPAIR OF ROOF, SUNKEN FLOOR, FALSE CEILING, RAIN WATER PIPE ETC OF RESTRICTED AND UNRESTRICTED AREA OF 506 ABW UNDER AGE B/R-II OF GE(EAST) JABALPUR
2024_MES_666972_1
8645/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (East) Jabalpur
D a (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹60,000
Yes
30 Dec 2024
20 Jul 2024
20 Sept 2024
20 Jul 2024
18 Sept 2024
5 Aug 2024
20 Jul 2024 - 27 Jul 2024
Amount
UNRESTRICTED AREA SCHEDULE
M&L Water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete:-
M&L for 10 mm thick rendering on roof surfaces/concrete surface in CM 1:4 with WPC complete all as specified and directed. Note : WPC shall be measured and paid separately.
Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg/Sqm complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces complete all as specified and directed..
APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 Gms/Sqm) land on primed surface by forced application complete all as specified with100 mm over laps sealed by flame as per manufacturers instruction.
Applying two coats of bituminous base aluminium paint including preparation complete all as specified and directed.
Supply liquid water proofing compound.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in roof padding/kerbs/ sunken slab etc complete all as specified and directed.
Dismantling water tanks capacity exc 250 Ltr and n.exc 500 Ltr and removing from site complete all as specified and directed.
Dismantling water tanks capacity exc 500 Ltr and n.exc 1000 Ltr and removing from site complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 Ltr capacity (Two layered and ISI marked) (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 1000 Ltr capacity (Two layered and ISI marked) (cylindrical vertical with closed top) hoisted & fixed in position as specified in SSR Part-I complete all as specified and directed.
Disconnecting existing tanks exc 250 and n.exc 500 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc & hositing if required reconnecting & re-fixing in position complete all as specified and directed. Note : Cleaning, repairing etc shall be measured separately.
Disconnecting existing tanks exc 500 and n.exc 1000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc & hositing if required reconnecting & re-fixing in position complete all as specified and directed. Note : Cleaning, repairing etc shall be measured separately.
Cleaning & removing all scale & dirt etc from tanks capacity exc 250 Ltr and n.exc 500 Ltr & from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning & removing all scale & dirt etc from tanks capacity exc 500 Ltr and n.exc 1000 Ltr & from mouths of circulating pipes, etc complete all as specified and directed.
Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing & connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore medium grade galvanished tube with all fitting & fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F 20 mm bore medium grade galvanished tube with all fitting & fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Fixing only 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
M&L for 16 mm outer dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
M&L for 20 mm outer dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
M&L for making connection of PP-R distribution branch with PP-R main of 16 mm to 40 mm outer dia pipe by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
S&F PP-R Gate valves (brass insert) 20 mm outer dia as per requirement of the site complete all as specified and directed.
Fixing only 20 mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, fibre glass sheet any gauge, thickness, including nainital or similar pattern roof covering complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth not otherwise described and treated with creosote complete all as specified and directed.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 (Gde-E-165) complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde E-250) quality A complete all as specified and directed.
Repairing sunken floor leakage as per following steps:- Surface preparation :- (i) Prior to application of Dr fixit powercrite, ensure to clean the substract which shoud be free from all the dust ,foregn particles, loose aggregate and oil grease etc, This can be done with the help of scarifying, grinding water jetting and sand blasting etc. (ii) The surface should be wetted well prior to application throughly with water to get SSD condition. (iii) All the depression or pin holes/pot holes to be repaired using Dr Fixit powercrete method mortar in mixing ratio of (1 kg cement : 1.50 kg silica sand : 0.50 kg of Dr Fixit powercrete) Coating application :- (i) }}Mix Cement with Dr. Fixit Powercrete in ratio of 1 : 0.50 ( 1 kg cement OP C53 : 0.50 Dr. Fixit Powercrete) by weight. (ii) The mix should be stirred thoroughly until smooth homogeneous paste is obtained (iii) Apply first coat over SSD/wet condition substrate (iv) Apply and unroll woven glass fibre cloth evenly on the wet coating before it dries out on larger areas (v) Using a nylon brush, apply one coat of Dr. Fixit Powercrete coating over the glass fabric so as to cover the fabric, allow 5-6 hours of air drying before application of another coat of Dr. Fixit Powercrete slurry coating over the surface. (vi) Provide polymer modified protective plaster of 15-20 mm thick over the coating to ensure safety from mechanical damage. Curing :- (i) Allow Dr. Fixit Powercrete coating to air cure for 3-6 hours after the final coat. (ii) Do not allow the rapid drying of the coating by covering the coating with help of polythene sheet in case of high humidity and windy condition. (iii) However, a moist curing after the air drying is advisable. (iv) Following the moist curing, Dr. Fixit Powercrete coating shall be allowed to air cured for 3 days before submerging it in water. Note: (i) The above procedure is given for Dr Fixit Powercrete, any other equivalent make may please be used as per their manufacturer instruction subject to approve by Engr-in-Charge. (ii) The sunken slab shall be measured for net area where the treatment to be done including vertical and horizontal surface.
M&L cement concrete 1:5:10, type E-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
S&F in repairs Vitreous China squatting pan, `Orrisa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern & flush pipe) complete all as specified and directed.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 Ltr capacity, low level, white, with intel, ball valve, float & handle including brackets complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F, PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
S&F, PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
S&F 100mm bore dia Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia around iron stays including bolts and nuts and securing ends of stays to wall or roof making good in all respect complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) branch pices single (single Y) equal of unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) branch pices single (single Y) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction double, (double T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction double, (double T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
M&L for PVC (SWR) floor trap plain with grating 75 mm including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) mulit floor trap with grating 75 mm including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for Suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600mm x 600mm compressing of GI powder coated Main Runner of dimensions 39mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4 mm+ PPPCGS/0.3 mm & weight of runner 1.35 Kg for 3600mm length), Cross Tee of dimensions 29mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4mm + PPPCGS/0.3mm & weight of Tee 0.195 Kg for 600mm length) and Wall angle of dimensions 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.3mm & weight of angle 0.70 Kg for 3050mm length) with and including 6mm thick HPSC (High pressure steam cured) pre primed, self embossed, textured designer board, water resistant, termite resistant, fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (weight 0.007 Kg/clip), hold down clips (weight 0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) comlpete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.11sqm but n.exc 0.18 sqm, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed in CM (1:6) compelte all as specified and directed.
M&L for Glazed ceramic tiles of size 350 x 250 x 7mm/ 450 x 300 x 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule complete all as specified and directed.
S&F in repair 15mm bore bib tap fancy type chromium plated long body cast copper alloy screwed down for iron pipes or for brass ferrule complete all as specified and directed.
S&F in repair Bib tap standard of PTMT, 15mm bore, any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed.
S&F in repair 15mm bore pillar taps cast copper alloy fancy type, chromium plated, screwed down high pressure with or without lattered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipes att complete all as specified and directed.
S&F in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair Brass CP bath Mixer (2/3 hole) for mixing hot & Cold water arrangement, long shank suitable 15mm bore of pipe of approved quality screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm bore stop valves cast copper alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F repair plastic water closet seat, white/black closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
S&F in repair 15mm bore stop valve/angle valve cast copper alloy fancy type chromium plated screwed down high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F in repair vitreous china wash basin white flat back size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm size stone aggergate as in floors in patches complete all as specified and directed.
S&F in repair 15 mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 with all fitting and fixed complete to walls, ceilings or in floors etc, any type of pipe complete all as specified and directed.
Supplying and laying 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using old bricks with sub class 'B' bricks curved on plan n.exc 6m mean radius built in CM 1:4 complete all as specified and directed. Note : Only for soak wel.
Taking down cement of cement lime plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed
M&L 15 mm thick rendering in CM 1:4 on external surfaces of walls finished even and smooth without using extra cement complete all as specified and directed
M&L two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxzide primer including preparation of surfaces complete all as specified and directed.
M&L two coat of syntetic enamel paint over new steel surface of any description n.exc 10 cm in width or girth not otherwise described over one coat red oxide primer including preparation of surfaces complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls by complete removal of existing treatment and applying two coat of oil bound distemper over a coat of birla wall care putty complete all as specified and directed.
M&L for preparation of new decorated surfaces of walls and applying two coat of oil bound distemper over a coat of birla wall care putty complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
RESTRICTED AREA SCHEDULE
M&L Water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete:-
M&L for 10 mm thick rendering on roof surfaces/concrete surface in CM 1:4 with WPC complete all as specified and directed. Note : WPC shall be measured and paid separately.
Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg/Sqm complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces complete all as specified and directed
APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 Gms/Sqm) land on primed surface by forced application complete all as specified with 100 mm over laps sealed by flame as per manufacturers instruction.
Applying two coats of bituminous base aluminium paint including preparation complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate in roof padding/kerbs/sunken slab etc complete all as specified and directed.
Dismantling water tanks capacity exc 250 Ltr and n.exc 500 Ltr and removing from site complete all as specified and directed.
Dismantling water tanks capacity exc 500 Ltr and n.exc 1000 Ltr and removing from site complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 Ltr capacity (Two layered and ISI marked) (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 1000 Ltr capacity (Two layered and ISI marked) (cylindrical vertical with closed top) hoisted & fixed in position as specified in SSR Part-I complete all as specified and directed.
Disconnecting existing tanks exc 250 and n.exc 500 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc & hositing if required reconnecting & re-fixing in position complete all as specified and directed. Note : Cleaning, repairing etc shall be measured separately.
Disconnecting existing tanks exc 500 and n.exc 1000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc & hositing if required reconnecting & re-fixing in position complete all as specified and directed. Note : Cleaning, repairing etc shall be measured separately.
Cleaning & removing all scale & dirt etc from tanks capacity exc 250 Ltr and n.exc 500 Ltr & from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning & removing all scale & dirt etc from tanks capacity exc 500 Ltr and n.exc 1000 Ltr & from mouths of circulating pipes, etc complete all as specified and directed.
Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing & connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore medium grade galvanished tube with all fitting & fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F 20 mm bore medium grade galvanished tube with all fitting & fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Fixing only 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Fixing only 20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, fibre glass sheet any gauge, thickness, including nainital or similar pattern roof covering complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 1 mm thick plain, black, mild steel sheeting in ridges, hips, valley gutters, drip and straight flashing (length and grith as fixed) complete all as specified and directed.
S& F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 (Gde-E-165) complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde E-250) quality A complete all as specified and directed.
Repairing sunken floor leakage as per following steps:- Surface preparation :- (i) Prior to application of Dr fixit powercrite, ensure to clean the substract which shoud be free from all the dust, foregn particles, loose aggregate and oil grease etc. This can be done with the help of scarifying, grinding water jetting and sand blasting etc. (ii) The surface should be wetted well prior to application throughly with water to get SSD condition. (iii) All the depression or pin holes/pot holes to be repaired using Dr Fixit powercrete method mortar in mixing ratio of (1 Kg cement : 1.50 Kg silica sand : 0.50 Kg of Dr Fixit powercrete) Coating application :- (i) }}Mix Cement with Dr. Fixit Powercrete in ratio of 1 : 0.50 ( 1 Kg cement OP C53 : 0.50 Dr. Fixit Powercrete) by weight. (ii) The mix should be stirred thoroughly until smooth homogeneous paste is obtained. (iii) Apply first coat over SSD/wet condition substrate. (iv) Apply and unroll woven glass fibre cloth evenly on the wet coating before it dries out on larger areas. (v) Using a nylon brush, apply one coat of Dr. Fixit Powercrete coating over the glass fabric so as to cover the fabric, allow 5-6 hours of air drying before application of another coat of Dr. Fixit Powercrete slurry coating over the surface. (vi) Provide polymer modified protective plaster of 15-20 mm thick over the coating to ensure safety from mechanical damage. Curing :- (i) Allow Dr. Fixit Powercrete coating to air cure for 3-6 hours after the final coat. (ii) Do not allow the rapid drying of the coating by covering the coating with help of polythene sheet in case of high humidity and windy condition. (iii) However, a moist curing after the air drying is advisable. (iv) Following the moist curing, Dr. Fixit Powercrete coating shall be allowed to air cured for 3 days before submerging it in water. Note: (i) The above procedure is given for Dr Fixit Powercrete, any other equivalent make may please be used as per their manufacturer instruction subject to approve by Engr-in-Charge. (ii) The sunken slab shall be measured for net area where the treatment to be done including vertical and horizontal surface.
S&F in repairs Vitreous China squatting pan, `Orrisa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern & flush pipe) complete all as specified and directed.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 Ltr capacity, low level, white, with intel, ball valve, float & handle including brackets complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
M&L PCC in foundations, filling and mass-concrete type E2 (1:5:10) using 40 mm graded stone aggregate complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F, PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
S&F, PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and directed.
S&F 100mm bore dia Stack clampsout of 50 mm by 5 mm flat iron and 16 mm dia around iron stays including bolts and nuts and securing ends of stays to wall or roof making good in all respect complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) branch pices single (single Y) equal of unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) branch pices single (single Y) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction double, (double T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction double, (double T) equal or unequal of 75mm bore of pipe complete all as specified and directed.
M&L PVC (SWR) floor trap plain with grating 75 mm including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) mulit floor trap with grating 75 mm including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for Suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600mm x 600mm compressing of GI powder coated Main Runner of dimensions 39mm x 24mm x 0.8 mm thick (Thickness comprising of GI/0.4 mm+ PPPCGS/0.3 mm & weight of runner 1.35 Kg for 3600 mm length), Cross Tee of dimensions 29mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4mm + PPPCGS/0.3mm & weight of Tee 0.195 Kg for 600mm length) and Wall angle of dimensions 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.3mm & weight of angle 0.70 Kg for 3050mm length) with and including 6 mm thick HPSC (High pressure steam cured) pre primed, self embossed, textured designer board, water resistant, termite resistant, fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (weight-0.007 Kg/clip), hold down clips (weight-0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) comlete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.11 sqm but n.exc 0.18 sqm, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed in CM 1:6 compelte all as specified and directed.
M&L for Glazed ceramic tiles of size 350 x 250 x 7mm/ 450 x 300 x 7mm thick in vertical surfaces such as dado/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule all complete all as specified and directed.
S&F in repair 15mm bore bib tap fancy type chromium plated long body cast copper alloy screwed down for iron pipes or for brass ferrule complete all as specified and directed.
S&F in repair Bib tap standard of PTMT, 15mm bore, any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed.
S&F in repair 15mm bore pillar taps cast copper alloy fancy type, chromium plated screwed down high pressure with or without lattered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipes, att complete all as specified and directed.
S&F in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair Brass CP bath Mixer (2/3 hole) for mixing Hot & Cold water arrangement, long shank suitable 15mm bore of pipe of approved quality screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm bore stop valves cast copper alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F repair plastic water closet seat, white/black closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
S&F in repair 15mm bore stop valve/angle valve cast copper alloy fancy type chromium plated screwed down high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F in repair vitreous china wash basin white flat back size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but incl brackets complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm size stone aggergate as in floors in patches complete all as specified and directed.
S&F in repair 15 mm bore Unplasticised PVC pipes of pressure rating 10 Kgf/cm2 with all fitting and fixed complete to walls, ceilings or in floors etc, any type of pipe complete all as specified and directed.
Supplying and laying 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using old bricks with sub class 'B' bricks curved on plan n.exc 6m mean radius built in CM 1:4 complete all as specified and directed. Note : Only for soak well.
Taking down cement of cement lime plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
M&L 15 mm thick rendering in CM 1:4 on external surfaces of walls finished even and smooth without using extra cement complete all as specified and directed.
M&L two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxzide primer including preparation of surfaces complete all as specified and directed.
M&L two coat of syntetic enamel paint over new steel surface of any description n exc 10 cm in width or girth not otherwise described over one coat red oxzide primer including preparation of surfaces complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls by complete removal of existing treatment and applying two coat of oil bound distemper over a coat of birla wall care putty complete all as specified and directed.
M&L for preparation of new decorated surfaces of walls and applying two coat of oil bound distemper over a coat of birla wall care putty complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
Schedule of credit amount of Rs. 1,77,130.00 to be deducted during AOC.
SHRI KRISHNA CONSTRUCTIONS (BID ID -3098845)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .