Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC REASONABLE RATE | |
| 2 | L2₹16.8 L+₹88,262 (5.56%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L2 | Rejected-Finance QUOTED HIGH RATE |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
26 Jul 2023, 6:00 pmClosed
HQ CWE AF Jaisalmer
AIR FORCE STAION JAISALMER 345001
REPAIRS TO AC PLANT AND REPAIRS TO ELECTRIC SUPPLY HT NET WORK AT AIRFORCE STATION CHAUHTAN UNDER GE AF UTARLAI
2023_MES_606907_1
80253
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE AF UTARLAI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹29,000
Yes
8 Aug 2023
30 Jun 2023
28 Jul 2023
30 Jun 2023
26 Jul 2023
14 Jul 2023
3 Jul 2023 - 7 Jul 2023
Amount
S&F in replacement of Micro processor based PCB card and display unit for 22.0 TR capacity water cooled Scroll chiller AC plant control as per OEM including pre-programmed software to control all parameter and chiller unit including taking down old one etc. complete all as specified and directed. Make: - Blue star or equivalent.
Dismantling of unserviceable centrifugal pump set couple type three phase 415 volts, 3/5HP at suitable for chiller line/ condensing line Compressor etc of any model/Make, strip opening and taking out of rotor carefully, cleaning of rotor and stator, taking out burnt stator winding without damage to stator body, rewinding the electric motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pump set etc including transportation to civil workshop and alignment in same vice -versa complete after replacing accessories as under: -: - (a) Gland bush, studs, nuts & washers (b) Ball bearing of pump set (c) Re-melting grinding and polishing of pump shaft as per existing size and shape complete. (d) Gland packing, greasing in pump bearings and making its proper alignment etc
S&F in replacement LP cut off control cut out 12 volt suitable for 22 TR AC plant capacity including taking down old one, etc. complete all as specified and directed. by Engineer-in-charge. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F in replacement HP cut off control cut out 12 volt suitable for 22 TR AC plant capacity including taking down old one, etc. complete all as specified and directed. by Engineer-in-charge. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F in replacement LP sensor 12 volt suitable for Scroll type AC of capacity 22 TR including taking down old one, etc. complete all as specified and directed. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F in replacement HP sensor 12 volt suitable for Scroll type AC of capacity 22 TR including taking down old one, etc. complete all as specified and directed. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F in replacement 3 Pole contactors uitable for central AC plant of capacity 22 TR as per existing make and model including taking down old one, etc. complete all as specified and directed.
S&F in replacement Air release valve 15/20/25mm dia for chiller plant including taking down old one, etc. complete all as specified and directed.
S&F in replacement of AHU belt of suitable size as per existing belt including taking down old one, etc. complete all as specified and directed.
M&L for cleaning in strainer and filter at main suction pipe line including taking down old one, etc. complete all as specified and directed.
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (hydrochloric acid) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x22 TR all as specified and as directed. (Chauhtan hill AC plant)
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 22 TR capacity complete all as specified and as directed. (Chauhtan hill AC plant)
Servicing and greasing of centrifugal pump set couple type three phase 415 volts, upto 3/5 HP at suitable for monoblock pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor cerefully, cleaning of rotor and stator, without damage to stator body, changing of bearing, including assembling all dessembled components, packing, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc on site complete all as specifiled and directed.
S&F in replacement Butterfly valve conforming to/ ISI marked, flanged both edges suitable for 50/65mm bore pipe, including rubber joints, nuts, bolts, gaskets & washers including testing and taking down old/unserviceable valve, etc. complete all as specified and directed.
S&F in replacement Water pressure gauge as per existing make and model for chiller / condenser pipeline, including testing and taking down old/unserviceable pressure gauge, etc. complete all as specified and directed.
S&F in replacement Water temperature gauge as per existing make and model for chiller / condenser pipeline, including testing and taking down old/unserviceable temperature gauge, etc. complete all as specified and directed.
S&F in replacement Micro processor based relay 5 Amp to 60 Amp including timer as per existing make and model including taking down old/unserviceable relay, etc. complete all as specified and directed.
M&L for recharge of Refrigerant gas R-410(a)/407 (a) in company sealed cylinder of any capacity complete all as directed by Engr-in-charge
S&F in replacement PVC cable flexible round 4 Core Copper conductor 6 sqmm including taking down old/unserviceable cable, etc. complete all as specified and directed.
M&L for painting to Central AC Plant 22 TR capacity including pipe lines, plaster work in existing colour code with water in and out symbols, Stickers, iron parts etc. with two coats of synthetic enamel paint complete all as specified and as diredted.(Chauhtan hill AC plant)
Supply, install, balance and commission in replacement of galvanised steel sheet metal 22 gauge round or rectanglular ducting of following sheet thickness having zinc coating of 160 g/sqmm total on both sides, hangers, MS angle supports/bracing frame etc. & HVAC duct construction standards metal and flexible of SMACNA along with required scaffolding work to install the ducts at site complete all specified and directed.
S&F in replacement of unserviceable scroll type Compressor 12 TR for chiller type AC plant electrically/mechanically from the system removal, lowering to the ground make Kirloskar / Tecumseh /Hitachi/ Carrier/ Donboss 12 TR capacity operated on R 407c/R410a/413 gas and 3 phase 415 volts electric supply including testing and taking down of old/unserviceable compressoror complete all as specified and as diredted
S&F for servicing, calibration, testing and setting of fault tripping relays as mentioned in maintance and operation manual of 11 KV HT VCBs as per OEM instructions complete all as specified and directed.
S&F in replacement Tripping Coil 24/110 Volts DC supply complete as per existing make and type complete all as specified and directed.
S&F in repacement Round Type Transformer Breather Set with Silca gel suitable for 11/0.433 KV Transformer as per existing at site complete all as specified and directed.
S&F in replacement of switch Air break Gang Operated Switch outdoor type HT 11 KV triple poles 200Amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechnically operating from ground level vertical mounted complete with HT insulator on steel frame (15 insulator type) for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top porcelene insulators with drop out fuses, operating rod made out of 20 mm GI pipe medium grade worked from ground level with handle and locking arrangment including jumpering, lead of wire/cable complete all as per specified and directed.
Supply, laying, jointing and testing under ground XLPE insulated, screwed, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade earthed system of size 95 Sqmm 3 core confirming to IS laid on hill top of chauhtan hill top in trenches, in floor, in duct, through pipes or along the pole, etc. including taking down old/unserviceable cable complete all as specified and directed.
Supply, lay, joint and test of Cable Jointing Kit in replacement for 11 KV(E) grade cable for indoor type termination straight through heat shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminum cable of size 70 to 95 sqm 3 core complete all as specified and directed.
Supply, lay, joint and test of Cable Jointing Kit in replacement for 11 KV(E) grade cable for outdoor type termination straight through heat shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminum cable of size 70 to 95 sqm 3 core complete all as specified and directed.
S&F in replacement Pin type Insulator, Porcelain, vitreous 150mm height and 150mm dia white, brown or green colour, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut , Frequency 50 Hz surface finish polished working voltage 11000 Volts complete all as specified and directed.
S&F in replacement Disc type Insulator, Porcelain, vitreous 145mm high and 255mm dia ball and socket type white,brown or green colour, two-in series asembly for tension with tension clamps for conductors, working pressure 11000 Volts complete all as specified and directed.
Supply, fill and top up New Transformer Oil, low viscosity type of dielectric strength not less than 50 KV into the conservator tank/body tank of the transformer/OCB/FRMUs/Voltage stabilizers etc at various locations in Chauhtan hill station complete all as specified and directed.
S&F 80mm bore galvanised pipe light grade of ISI marked with all fittings including fixing arrangements on hill (stones, etc) required to be laid on hill top chauhtan for passing of cable fixed to poles/walls/laid under floor/ laid in trenches/fixed on stones, etc. as cable protection including taking down old/unserviceable GI pipe with fittings compete all as specified and directed..
M&L for Earthing in replacement complete with copper earth plate electrode 60cm x60cm x 3.15mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level ,connected to and including copper earth strip 20X3mm by means of nut, bolts, check nuts and washers made of copper alloy and connection to test point and earth dolly and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil/rock strata and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I complete with the following:- (a) Excavation and earth work for drilling hole for electrode in any type of Soil/rock strata. (b) PCC chamber in cement concrete 1:3:6 type C-1, Pre-cast RCC cover with CI frame with suitable handle 50 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with 20 mm bore galvanised iron medium grade watering pipe and lugs etc complete all as specified and directed. (d) 40 mm bore galvanised iron medium grade protection pipe for protection of earthing lead and earth lead, each 7.5m long complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. Note:- Copper strip and 40mm GI protection pipe upto 7.5m each shall be deemed to be included in quoted rate of this item. (ii) If the desire earth resisitance not obtained on testing after completion, earthing shall be redone by the contractor without any extra cost upto obtain the desired resistance. (iii) Tibba sand shall be shall be used by the contractor after filling of salt and charcoal for earthing.
S&F in replacement of aluminium conductor steel reinforced (ACSR) of any size any description including stretching on over head lines on HT/ LT poles including binding the ACSR with insulators, aluminium binding wire including jumpering the over head line, jointing, etc complete all as specified and as directed.
S&F in replacement galvanised stay assembly complete with 20mm dia stay rod including stay starnd 7/4mm fixed for stay of poles including GI nuts, two numbers thimbles MS clamps made out of 50mmx6mm flat iron including MS nuts bolts and washers 300mm x 300mm x 6mm MS stay plate, stay bow of size 40cm long 16mm dia, loop type insulator including painting the exposed MS work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and erect in replacement of prestressed concrete pole, 9.0metres long, 102mmx172mm at top and 102mm x 279mm at bottom, class 10, including replacement of unserciveable/broken PCC poles and painting of pole upto 1.5 m of height from coping level with alternative black and white strip of width not less than 0.3m and Writing pole No with with black or white colour by means of stencils complete all as specified and directed.
Supply and erect in replacement of prestressed concrete pole, 11.0metres long, 152mmx152mm at top and 152mm x 260mm at bottom, class 9, including replacement of unserciveable/broken PCC poles and painting of pole upto 1.5 m of height from coping level with alternative black and white strip of width not less than 0.3m and Writing pole No with with black or white colour by means of stencils complete all as specified and directed.
Excavation in trenches in hardrock, not exc 1.5m wide and not exc 1.5m in depth , for foundation of poles, laying of cables, laying of pipes, etc and getting out complete all as specified and directed.
All as per item no 39 above, but exc 1.5m and not exc 3.0m in depth complete all as specified and directed.
Removing excavated material (rock ) to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation of poles, etc. complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of poles including necessary form work etc. complete all as specified and directed.
S&F in replacement of MS Cross arms , bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F in replacement of HT Lightning Arrestor 12 KV, normal discharge current of 10 KA station class including jumpering, lead of wire/cable complete all as specified and directed.
S&F in replacement of Danger notice plate for LT 440 Volt of size 25cm x 15cm x 1.6mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones and wtitten as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25mm x 3mm, including nuts & bolts, including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to be written in two languages viz. -Hindi and English.
S&F in replacement of Danger notice plate for HT 11000 volt of size 25cm x 20cm x 1.6mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones and wtitten as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25mm x 3mm, including nuts & bolts, including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to be written in two languages viz. -Hindi and English.
Filtration, heating and dehydration of old transformer oil for increasing dielectric strength not less than 45 KV, if the results below 45KV, the oil shall be replaced with new oil complete all as specified and directed. Note:- New oil required for toping oil levels or for replacement maint shall be measured and paid separately.
S&F in replacement of loop type insulator porcelain viterous white or brown, for HT 11000 volts large size with overall dimensions 90x140mm, clearance hole 25.5mm complete all as specified and directed.
Rasam Engg Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .