Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹7.0 L+₹13,263.86 (1.93%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹7.4 L+₹52,822.86 (7.69%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹8.8 L+₹1.9 L (27.5%)Rejected-AOC | L4 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
26 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I)CIF(U)
AGE(I)CIF(U) C/O 56 APO
REPAIR/REPLACEMENT OF LT PANELS, CABLES, EARTHINGS, POLES AND OVER HEAD CONDUCTORS AT HQ CIF(U)UNDER AGE(I) CIF(U).
2020_MES_381719_1
AGE(I)CIF(U)-23/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I)CIF(U)
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE(I)CIF(U)
₹20,000
Yes
7 Dec 2020
29 Sept 2020
28 Oct 2020
29 Sept 2020
26 Oct 2020
7 Oct 2020
60 days
Amount
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete.
Labour and tools for breaking of PCC (for taking out PCC poles) and removing broken PCC outside cantonment area to a distance beyond 5 km but not exceeding 15 m and depositing at a level not exceeding 1.5 m above the starting point complete.
M&L for PCC 1:2:4 typeB-1 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed .
M&L for PCC 1:3:6 typeB-1 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed .
S&F 40 mm bore Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles / laid in road crossing etc as required.
S&F 80 mm bore Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles / laid in road crossing etc as required.
S & F Pre stressed concrete pole,9.0 meters long,102mmx152mm at top and 102mmx289mm at bottom, class 10 all as specified and directed (Note : Earth work excavation, PCC foundation and coping will be measured and paid separately)
M&L for cross arms support clamps fabricated from steel incl nuts, bolts and washers, weldind, bending, drilling holes in any shape and size all as indicated and directed including one primer coat, one under coat and one finishing aluminium paint
Supllying and fixing Shacle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts 50 mm height,65 mm dia for 550 volts grade comlete.
Suuplying and fixing loop type insulator, porcelain,vitreous white brown or green, large size with overall dimensions 90x140mm and clearance dia of hole 25 mm complete.
M&L for galvanized stay strand of size 7/4mm all as directed.
Supply and fixing stay assebly with 20mm dia stay rod coplete with accessories as shown in Electrical plate No.1(Loop type insulators, stay clamps, excavation and concrete measured seperately.
Material and labour for ACSR conductor squirrel to dog (6/1/2.11 to 6/1/4.72) any size drawn straignt horizontal on over head lines on existing poles including binding with insulators.Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed.
M&L for galvanized iron steel wire 4 mm dia drawn straight horizontal as continous earth wire on HT/LT poles
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 10 sqmm 2 core . (Make - Havells / Polycab / Finolex / Universal as approved)
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 16 sqmm 2 core. (Make - Havells / Polycab / Finolex / Universal as approved)
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 16 sqmm 4 core. (Make - Havells / Polycab / Finolex / Universal as approved).
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 25 sqmm 4 core. (Make - Havells / Polycab / Finolex / Universal as approved)
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 50 sqmm 3.5 core. (Make - Havells / Polycab / Finolex / Universal as approved).
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 70 sqmm 3.5 core. (Make - Havells / Polycab / Finolex / Universal as approved).
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 95 sqmm 3.5 core. (Make - Havells / Polycab / Finolex / Universal as approved).
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 120 sqmm 3.5 core. (Make - Havells / Polycab / Finolex / Universal as approved).
Dismantling concrete poles/strut, any size and setting aside in low lying area outside the cantonment.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
Dismantling insulators any type any size.
Dismantling stay assembly.
Dismantling GI earth wire.
Dismantling ACSR conductors.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead of galvanised iron strip of size 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore light gradeGI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009 and testing on completion. (Note : Earth result should not exceed 2 Ohms)
Supplying and making in renewal straight through joint heat shrinkable type for 1.1 KV grade XLPE cable of 25 sqmm 4 core to 50 sqmm 3.5 core. Size (Make - Denson / M-Seal / 3M as approved)
Supplying and making in renewal straight through joint heat shrinkable type for 1.1 KV grade XLPE cable of 70 to 150 sqmm 3.5 core. (Make - Denson / M-Seal / 3M as approved)
M&L for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete.
Restringing/restretching aluminium conductor on existing over head lines( dismantled under item no 1 above including necessary binding with binding wire with insulator , connections of incoming and out going cables complete all as specified and directed.
M&L for painting to PCC/steel tubular poles 9/11 mtrs upto 1.5 mtrs height from ground level with white and yellow synthetic enamelled paint in alternate strips of 30 cms all as specified and directed.
Numbering of poles with synthetic enamelled paint with letters of size not less than 50mmx10mm(HeightxWidth) compete all as specified and directed.
Taking out old u/s XLPE cables of 10 to 16 sqmm 2 core, 1.1 KV Size.
Taking out old u/s XLPE cables of 16 to 25 sqmm 4 core, 1.1 KV Size.
Taking out old u/s XLPE cables of 50 to 120 sqmm 3.5 core, 1.1 KV Size.
Taking down old u/s GI protection pipe of sizes 40 to 80 mm bore.
S&F in replacement of MCCB 63amp, 4 pole, 16KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 4200 13 or equivalent in Schneider or Hager as approved.
S&F in replacement of MCCB 63amp,3 pole, 16KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 420003 or equivalent in Schneider or Hager as approved.
S&F in replacement of MCCB 100 amp,4 pole, 16KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 420015 or equivalent in Schneider or Hager as approved.
S&F in replacement of MCCB 125 amp, 4 pole, 16KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 420016 or equivalent in Schneider or Hager as approved.
S&F in replacement of MCCB 160 amp, 4 pole, 25 KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 4200 57 or equivalent in Schneider or Hager as approved.
S&F in replacement of MCCB 250 amp, 4 pole, 25 KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 4202 19 or equivalent in Schneider or Hager as approved.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item).
Supplying, installation, testing & commissioning in CPRI approved outdoor cubical type LT of size 1.5Mx1.2Mx0.60M depth,(HxBxD) panel suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design with CRCA sheet 3.15 mm thick, factory made, totally enclosed having front and rear openable, powder coated, dust, weather & vermin proof, having TPN aluminium bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls :- Incoming:- One number MCCB 200 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz with thermal magnetic release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 4202 48 or equivalent in Schneider or Hager as approved. Outgoing:- (i) One numbers MCCB 160amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420057 or equivalent in Schneider or Hager as approved. (ii) One numbers MCCB 100amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420055 or equivalent in Schneider or Hager as approved. (iii) One numbers MCCB 63 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420053 or equivalent in Schneider or Hager as approved.
RAVI KUMAR
MAMTA ENTERPRISES
M/S MANJIT SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .