Upgradation of CETP SiteII Battal Ballian Udhampur by way of SITC of servo transformer along with inverter and change over with allied accessories and
2023_SICOP_235722_1
SICOP/GM(P)/2023/10B Dated 03-11-2023
Open Tender
Electrical Works
Item Rate
30 days
Battal Ballian Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
0028010100002270 IFSC Code JAKA0INDUDH
₹18,900
22 Nov 2023
3 Nov 2023
18 Nov 2023
3 Nov 2023
17 Nov 2023
3 Nov 2023
Amount
Supply, installation,testing and commissioning of Inverter 850 va with battery 150ah including trolley complete with all accessorries as required.( Make: Microtek/Luminous/Exide)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 35 sq. mm and upto 95 sq. mm
Supply, Installation,testing & commissioning of 3.5C X 70sqmm cable, 1.1KV grade, armoured , XLPE insulated Stranded Conductor FRLS type. ( make: havells/rr cabel/polycab/finolex)
Providing and fixing of Main Pannels 14 swg with double aluminium Bus bars and allied accessories of different size chambers conssits individual doors for MCB's and MCCB's, energy meter chambers and other switch gears etc as per IS standards and requirement complete with following details including grouting with foundation complete. MCCB's should be ABB, Schneider/L&T/ Siemens/Anchor/ Havells, MCB's should be Havells/ABB/Anchor/Schneider/L&T, CT's Meter should be AE/Rishab/Morley or equivalent make& should be CPRI approved. (Panel Size: 3'x3'x1'-6'')
Providing and fixing following rating and breaking capacity and pole MCCB/MCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make: Schneider/Havells/L&T/Anchor/Hager/siemens)
100 A , 16 KA,TPMCCB
63A MCCB, 4P,10Ka or more
Aluminium bus bar 100amp 3 phase(1set= 4 burbar runs)
Changeover switch - front operatable 100Amp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.( Make: Dowells/3D/Gripwell/Siemens or equivalent) 3½ X 70 sq. mm (38mm)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (Hot dipped galvanized)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, Installation, Testing and commissioning of 125 Kva Copper Wound Servo Controlled automatic voltage Stabilizer with the following specifications: Input voltage range = 230 to 460 volts (Phase to Phase) b) Output voltage range = 415 volts + 2.5% (Phase to Phase) c) Frequency: 50 HZ. d) Capacity overload: 20 % overload for one hour. e) Protection : Over Load & Short Circuit f) Three Phase g) Indoor type h) Unbalance type i) It shall Suitable for all power Factor.
M/s delta generation
M/S SHRI ANUBHAV GANDOTRA
SHIV OM BUILDERS
JCM CONSTRUCTIONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .