| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹27.9 L+₹26,730 (0.97%)Rejected-Finance ADARSH COLONY GOLE KA MANDIR GWALIOR MP | GWALIOR | MADHYA PRADESH | 474001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹28.4 L+₹72,321 (2.62%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L3 | Rejected-Finance Being other than lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Firm not meeting eligible criteria. Firm already secure two work in MES as a unlisted contractor. |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 May 2025, 6:00 pmClosed
CWE AF Gwalior
HQ CWE AF GWALIOR
REPAIR MAINTENANCE OF CENTRAL AC PACKAGE TYPE PLANTS AND HOT WATER GENERATORS OF DIFFERENT CAPACITIES IN TECH AREA AT AF STN GWALIOR
2025_MES_705818_1
86016/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN Gwalior
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF TECH AREA GWALIOR
₹70,000
Yes
24 Jul 2025
29 Apr 2025
3 Jun 2025
29 Apr 2025
27 May 2025
13 May 2025
Amount
Dismantling and removing old U/S compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 12.5 TR Model No SZ185S4RC of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant Complete all as specidfied and as directed. Note:- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour, fixing & T & P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling the compressor the Refrigerant gas to be taken in empty cylinder by the help Ice or as directed by Engineer-in-Charge.
Supply, installation , testing and commissioning of 20mm Automatic Air Vent valve made out brass suitable to purge out the trapped air in the water pipe line Complete all as specidfied and as directed.
Supply , instalation , testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.50°C least count, range 0-50°C. Brass oil filled thermowell of size as per site condition and all as specified and as directed.
Supply , instalation , testing and commissioning of stain steel water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing syphon, socket. Range (0-50) / (0-100) as Complete all as specidfied and as directed. .
Supply and fix in repairs of Chilled water sensor as per existing make and type complete all as specified and directed
Supply and Fix in replacement float valve assembly 15 mm complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement float valve assembly 20 mm complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement float valve assembly 25 mm complete all as specified and directed by Engr-in-Charge.
Supply and Fix for wire mesh made put of PVC and mesh size not less than 25 mm fixed in cooling tower by nut/bolts as directed by Engineer-in-charge.
Supply and fix in replacement of digital modulating thermostat for operation of automatic 3 way mixing valve alongwith suitable sensor and cable from sensor to thermostate and 3 way automatic mixing vlve complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of step down transformer 220 V AC to 24 /13 VDC as per site condition complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 3.0 to 7.5 Amp with single phasing protection, all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 9 to 15 Amp with single phasing protection, all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 14 to 23 Amp with single phasing protection, all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of unserviceable C.T 300/400/5A or suitable size for HAVC panels complete all as specified and directed by Engr-in-Charge.
Supply and fixing panel mounting digital ammeter 3 phase, 3 wire, Display type : red LED 14.2 MM (0.56") including control wiring from ammeter to CT's complete all as specified and directed.
Supply and fixing panel mounting digital voltmeter 3 phase, 4 wire, Display type : red LED 14.2 MM (0.56") including control wiring complete all as specified and directed.
Supply and fix in repairs on-off push button pendants with elements red/green/orange of make MIMIC/ M/s L&T/ Legrand / HPL all as specified and directed.
Supply and fix in repairs DOL starter in sheet steel enclosure, A/C 3 phase, type MN, required for 1/1.5/2/3/5 HP, 415 Volt 3 Phase motor all as specified & directed by Engr-in-Charge to the entire satisfaction of department.
Supply and fix in repairs Star - Delta starter in sheet steel enclosure, A/C 3 phase, type MN, required for 5/7.5/10 HP, 415 Volt 3 Phase motor all as specified & directed by Engr-in-Charge to the entire satisfaction of department.
Supply and Fix in replacement gland packing in 7.5/10/12.5 HP pump set Superior quality including replacement of damaged nut / bolt and washer as per site requirement complete all as specified & directed by Engr -in- Charge.
Supply and Fix in replacement gland packing in 1.5/3.0/5.0 HP pump set Superior quality including replacement of damaged nut / bolt and washer as per site requirement complete all as specified & directed by Engr -in- Charge.
Dismantling electrically and mechanicall seal electric motor any size, dismantling part, taking out unserviceable bearing including supply and replacement of new bearing, reassembling, reinstallation and testing the following size all as specified & directed by Engr-in-Charge :-
(a) ball bearing 6305/6306/6308 or suitable size
(b) ball bearing 6203/6204 or suitable size
Material and Labour for spray painting to Central AC Plant complete system of capacity 15 to 100 TR complete comprising of chiller unit, compressors, motors, condensor, cooling tower and cooling tower pumps, pump / monoblocks, HWG, HWG Pump & motor, Cooling tower stands, MS / GI pipe lines of various sizes etc after preparation of old painted surface as per colour code and marking arrow, SM/ MES Nos, of approved colour complete all as directed by the Engr-in- charge.
Material and Labour for Removing scale/sludge precipitated in the HWG Tank on the heating element and pipe, circulating the descaling solution in the pipe through the circulating pump and allows holding it for 30 minutes for chemical reaction. Ensure that descaling process has been completed , circulate clean water in the pipe continue till satisfaction of Engr-in-Charge testing complete of capacity upto 100 Kilowatt
Supply and fixing in possition Heavy duty hot dip galvanised powder coated cable trunking perforated type without cover of the sizes 300 mm wide x 50 mm wall height cable tray for supporting 1100 Volts grade armoured/ unarmoured aluminium/ copper conductor cables, fabrication from angle and perforated 2mm (14 SWG) thick M.S. CRCA sheet powder coated with expansion coupler plates duly galvanised, with bolts, washer and nuts, knock out holes for cable connections as per approved disign. the tray shall comply with the specification of NEC (National Electric Codes) and NEMA ( National Electric Manufacturers Association) the steel shall be as per IS: 226 and galcanising as per IS: 2629/BS 729/ASTM 123 including taking down of existing cable of carefully and fixing the cable on cable tray complete Note :- 1)Painting the support structure with two coats of red oxide and two coats of enamel colour paint of approved shed shall be included in the quoted rates.. 2)All material shall be Hot dip galvanised (86 micron Zinc thickness min.) as per IS and specifications. 3)Tying of cables with cable trays with proper dressing and connection of cable from panel and equipment with suitable thimble, gland and lugs shall be included in the quoted rates. 4)Structural steel required for cable tray support will be measured and paid seperately.
All as per Ser Item No 26 here in before but size 100 mm wide x 25 mm wall height cable tray
Supply and fixing cable tray/bus bar fixing supports and other steel work including MS flats, angles, T iron, channel etc. cutting drilling holes/welding in MS members as per the site requirements, duly painted the supports with 2 coats of synthetic enamel paint over a coat of primer, including provision of dash fasteners and other fixing accessories complete all as specified.
Supply, Installation, Testing & Commissioning of 200 mm dia preinsulated flexible duct made out of galvanised iron duly insulated with glass wool and aluminium foil on outer surface with end clamps including fixing arrangment into dehumidifiers outlet and building structure and making suitable opening in wall to fix properly. Box type collar with MS jali shall be provided in the building outlet.
Material and Labour for replacement of unserviceable pot strainer 80/100mm including replacement of unserviceable rusted nut bolts, washers, & gasket, all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of HP/LP cut-out switch with male / female connector of AC plant as per existing make, model & type including its control wiring as per existing complete all as specified and directed by Engr-in-Charge.
Material and Labour for Replacement of old unserviceable pressure relief valve of condenser 3/8" BSP threaded suitable for 300 PSI including control wiring complete all as specified and directed by Engr-in-Charge.
Material and Labour for replacement of worn-out crankcase heaters of compressor including its control wiring as per existing all as specified and directed by Engr-in-Charge.
Material and Labour in repairs Strip heater finned 2 inch wide aluminised steel fins of 415 volt 1.5 to 3 KW capacity to match with the existing including control wiring with fibre glass copper wire, all as specified and directed by Engr-in-Charge.
Supply and fixing of Bakelite connector as per site requirement 6 Amp to 35 Amp, all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of Single phase preventor type SPP VSPD-2 phase, 415 Volts, 50 Hz AC, all as specified and directed by Engr-in-Charge.
Material and Labour for Nitrogen leak test for entire system of the AC plant of Capacity upto 100 TR with Nitrogen gas. If found any leakage or reduction in the scale of pressure shall located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage permanently, complete all as specified & directed by Engr-in-Charge.
Supply and fixing of filter drier capacity as per site requirement for chiller as per existing make and model complete all as specified and directed.
Labour only for Charging of refrigerant gas R- 407c/ R134/R22 /R-410 in sealed cylinder after making system leak proof complete all as specified and as directed. Note : Refrigerant gas will be issued by department under Schedule 'B'
Servicing of cooling coils and air filters of AHUs installed at air conditioning plant by removing air filters and fixing ack after cleaning with air blower and water and cleaning agent , cleaning of cooling coil with wire brush and air blower and water spray pump after spraying scale gun or equivalent chemical suitable for aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity upto 10000 CFM.
Servicing of cooling coils and air filters of AHUs installed at air conditioning plant by removing air filters and fixing ack after cleaning with air blower and water and cleaning agent , cleaning of cooling coil with wire brush and air blower and water spray pump after spraying scale gun or equivalent chemical suitable for aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity 10000 CFM to 20000 CFM.
Supply and fix filter regenerable coarse type, dust proof for following sizes:- (a) AHU filter of size 60cm x 60 cm x5 cm
(b) AHU filter of size 60cm x 50 cm x 5 cm
(c) AHU filter of size 60cm x 40 cm x 5 cm
(d) AHU filter of size 60cm x 30 cm x 5 cm
Supply and fix in replacement of thermostatic expansion valve of capacity 5 TR and model as per site requirement for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure.
Supply and fix in replacement of thermostatic expansion valve of capacity 12.5 TR and model as per site requirement for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure.
Supply and fix in replacement of thermostatic expansion valve of capacity 21/22 TR and model as per site requirement for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) for base of path/ hard standing.
M&L PCC 1:2:4 type B-1 using 20mm graded agreegate as in coping / benching /foundation etc all as specified and directed by Engineer-in-Charge.
M & L Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, Complete all as specidfied and as directed.
Supply and fix in replacement of PCB for water cooled chiller unit (26 x 2) 52 TR suitable for operating two compressor, comprising of display unit, control transformer and main PCB working on 12Volt control system including control wiring required to run the system and updation of necessary software for control and safety features complete all as specified and directed.
Supply and fix in replacement of PCB for water cooled chiller unit (13 x 4) 52 TR suitable for operating four compressor, comprising of display unit, control transformer and main PCB working on 12Volt control system including control wiring required to run the system and updation of necessary software for control and safety features complete all as specified and directed.
Supply and fix in replacement of PCB for water cooled chiller unit (13 x 2) 26 TR suitable for operating two compressor, comprising of display unit, control transformer and main PCB working on 12Volt control system including control wiring required to run the system and updation of necessary software for control and safety features complete all as specified and directed.
Supply and fix in replacement of PCB for water cooled chiller unit (13 x 3) 39 TR suitable for operating three compressor, comprising of display unit, control transformer and main PCB working on 12Volt control system including control wiring required to run the system and updation of necessary software for control and safety features complete all as specified and directed.
Supply and fix in replacement of PCB for water cooled chiller unit (21.2 x 4) 85 TR suitable for operating four compressor, comprising of display unit, control transformer and main PCB working on 12Volt control system including control wiring required to run the system and updation of necessary software for control and safety features complete all as specified and directed.
Supply and fix in replacement of PCB for air cooled package unit (5.5 x 2) 11 TR suitable for operating two compressor, comprising of display unit, control transformer and main PCB working on 12Volt control system including control wiring required to run the system and updation of necessary software for control and safety features complete all as specified and directed.
M&L for cleaning of air handling ducts (GI/Al) internally by using special equipments & tools like robotic arm, air jet nozzles, flipper vaccum pump and a suction blower with hepa filter, complete all as specified and directed.
M/S uneversal agency (BID ID -3306497)
Uma engineers (BID ID -3300707)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .