Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.2 L+₹3.1 L (15.2%)Rejected-Finance MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
21 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS
GE 881 EWS C/o 56 APO
GE/PNH-79/2019-20
2020_MES_339535_3
GE/PNH-79/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹36,000
Yes
1 Jun 2021
5 Aug 2020
24 Aug 2020
5 Aug 2020
21 Aug 2020
6 Aug 2020
60 days
Amount
B&R PORTION:- Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as directed by Engineer-in-Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, complete all as specified.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation of poles / Struts and mass concrete, all as specified directed.
Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:4), complete all as specified and directed.
Description all as per item No. 08 above, but except stone complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), all as specified and directed.
Description all as per item No-10 above, but except brick, complete all as specified.
Precast PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) as in bond stone, bed plate, strings coarse etc and set in CM (1:6), complete all as specified.
Extra over stone walling of random rubble walling, uncoursed or brought for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified.
Cement concrete (1:2:4) type-B-1 (using 20mm graded stone crushed aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
Precast cement concrete (1:2:4) type-B-0 (using 12.5mm graded stone crushed aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mould- ings but excluding frame and set in CM (1:4), complete all as specified and directed.
Rendering 20mm thick on other than fair faces of brick work or stone masonry surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement , complete, all as specified.
Flush pointing to random rubble masonary, or polygonal rubble, uncoarsed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
Two coats of cement based paint over a coat of approved primer (alkaliresistant priming paint) on newly plastered surfaces of wall including preparation of surfaces, complete, all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto all as per description of item No-21 above, complete all as specified.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified.
Providing reinforced cement concrete type B-1, 1:2:4 (20 mm graded crushed stone aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed, complete all as specified.
Mild steel work as in posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed and similar work conforming to Fe-290 Gde E-165 all as specified.
Supply only Chain link MS galvanisd fencing, any size or type, complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified.
Galvanised, 2 strand steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing and tying at crossings with and provision of galvanized mild steel wire, staple or steel pins, etc complete all as specified and directed.
Mild steel Round bars 6-8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
Mild steel screw bolts 5-10mm dia at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut not exceeding 5cm long, complete all as specified and directed.
Mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, and similar works, complete all as specfied.
Mild steel work conforming to Fe-290 (Gde E-165) as in steel gate etc. with & including pintle hinges, stops, hand-made sliding bolts, etc, complete all as specfied.
Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
TMT bars, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified.
RCC (nominal mix) 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in beams , cantilevers, bressummers, lintel over 1.5 mtr span, complete all as specified.
RCC (nominal mix) type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified.
RCC (nominal mix) 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in slab supported on walls, columns in floors, roofs, landings, balconies and in shelves, complete all as specified.
Form work to sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs etc and similar works for rough finished surfaces of concrete, complete all as specified.
Form work to sides of pillars, posts, struts piers, columns and stanchions and similar worksfor rough finished surface of concrete complete all as specified & directed by Engineer-in- charge.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified.
Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:4,complete all as specified and directed.
100mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in path, road, hardstanding etc, finished the surface even & fair, complete all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, pointed with grey cement and pigments, as in path etc laid over & including 25mm thick sand filling under pavers and paking the joints of paver block with sand, including watering and consolidation all as specified and directed by Engr-in-Charge.
Broken glass coping on top of walls in cement mortar 1:3 or in PCC 1:2:4, complete all as specified and directed by Engr-in-Charge.
E&M PORTION:- Repair of electric water heater (Geysers) of capacity 25 ltrs storage type including disconnecting of electric & water connections and taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly etc, cleaning internally and externally including checking for leakage in geyser tank and rectifying the same by soldering / brazing, replacement of unsv accessories like inner shell, geyser element, themostate switch, gasket, nuts, bolts and clamps etc and Re - assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing on complete to the entire satisfaction of the Engineer- in- Charge . (Unserviceable accessorise like inner shell, thermostat switch, geyser element and geyser assembly etc shall be measured and paid separately , if replaced as required under respective items).
Description all as per Srl Item No.-46 above but geyser of capacity 35/50 Litres, complete all as specified and directed.
Supply only inner shell stainless steel for storage type water heater 25 Litres capacity to match the existing model of geysers all as specified and directed by Engineer - in- Charge. Make : Same as per existing make of geyser and as approved by GE.
Description all as per Srl Item No.-48 above but for geyser of capacity 35 Litres, complete all as specified and directed.
Description all as per Srl Item No.-48 here in before but for geyser of capacity 50 Litres, complete all as specified and directed.
Supply only heating element push type, 1500 watt of triangular shape, conforming to ISI with rubber washers with clamps, complete all as specified and directed by Engineer - in – Charge.
Description all as per Srl Item No.-51 above but 2000 watt, complete all as specified and directed.
Supply only thermostat switch suitable for storage type geysers ranging 60 degree to 90 degree adjustable type operation on 240 Volts, complete all as specified and directed by Engineer - in - Charge. Make : Bajaj, Spherehot, Racold / other ISI make as approved by GE to match with existing make.
Supply only 15mm PVC connection wire woven with nickel plated brass adopter, both sides threaded, in standard length of 30cm to suit the size of geysers complete all as specified and directed by Engineer - in - Charge.
Supply only Neon lamp indicator red colour in circular / rectangular shape as suitable and as per existing model complete all as specified and directed by Engineer - in - Charge.
GI tubing, medium grade in short lengths with all fittings such as elbow, tee, socket, nipple, reducing socket, reducing elbow, reducing tee including guttees / saddles etc of size 15 mm bore and fixed to wall / floor / ceiling including connection to mixing arrangements of hot / cold water and making good disturbed surfaces all as specified and directed by Engineer - in – Charge.
Taking down and refixing of after spray painting to geysers of 25 litres capacity with one coat of synthetic enamel white paint externally after preparation of surfaces including writing MES numbers with black paint in 25mm size letters, all as specified and directed by Engineer - in – Charge
Description all as per Srl Item No. 57 above but geysers of 35/50 lires capacity all as specified and directed by Engineer - in - Charge.
Replacement GM stop cock of 15mm bore, ISI marked as per sample all as specified and directed by Engineer - in – Charge.
Replacement of 3 core flexible copper conductor cable of size 2.5 sqmm all as specified and directed by Engineer - in – Charge. Make : Paragon/ Kalinga/ Plaza
Rplacement of top plug 3 pin, 15 Amps, all as specified and directed by Engineer - in – Charge.
Cleaning storage tank of solar heating system of any capacity /size along with complete glass tubes for inside, outside/solar panel all as directed for smooth and efficiant function of system. Note :- 1. Any damage including to glass parts / solar tube/solar panel as solar water heating system during the cleaning process will be make good / replaced by contractor, cost of the same deemed to be included in the rate quoted by contractor . 2. All rubber parts or minor hidden parts such as PVC ellbow, joint, plug etc shall be replaced by contractor for effeciant functioning of system and cost of the same deemed to be included in the rate quoted by Contractor.
Removing old paint from the complete structure related to solar water heating system, by scrubbing with emery paper, applying one coat of red oxide piant and two coat of super enamelled paint of branded company(colour of paint as approved by GE), complete all as specified.
Cleaning of HDPE water storage tank from inside and outside for solar water heating system for smooth and efficient functioning of system & removing the scale / dirt from inlet / outlet pipe complete as per direction of Engr in charge.
Replacement of heating element 2 KW ISI marked of solar water heater of size 150 Ltr to 300 Ltr, complete all as directed by Engr in charge. Note :- Make and model of heating element shall be as per sample on site for solar water heating system.
Replacement of tharmostate switch suitable for solar water heater of size 150 Ltr to 300 Ltr , complete all as directed by Engr in charge. Note:- Make and model of thermostate shall be as per sample available at site to sait the solar water heating system.
Taking down ceiling fans of any type and size after disconnecting from existing ceiling rose to connector and clamp hooks and transportation to work shop, cleaning externally, dismantling and examining the rotor, startor, bearings, bushes, winding etc; for serviceability and repairing/replacing the defective parts subsequently oiling, greasing, assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging and connecting the electrical connections, testing for noise free smooth running etc. as directed.
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screws as appropriate shape and size suitable for ceiling fan of any make and size 1200mm sweep complete all as specified and as directed.
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screws as appropriate shape and size suitable for ceiling fan of any make and size 1400mm sweep complete all as specified and as directed.
Taking out existing worn out nut, bolt, rubber bush, cotter pin, and supply and fix new metallic clamps, rubber bush, nut bolt, washer and cotter pin and for various types of ceiling fans to complete the repair work all as directed.
Painting of ceiling fans along with blades of any make/model of size 1200 to 1400mm sweep with spray paint white in colour supper enameled paint, writing MES No. in 20mm letter size with black paint etc complete all as specified and as directed.
Taking out defective/worn out bearing of any make and supply and fix new bearing suitable for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and as directed.
Taking out defective capacitor and supply and fix new capacitor of 2.5 mfd of approved make for various makes of ceiling fans complete all as specified and as directed.
Taking out worn out Gun metal bush and supply and fix new Gun metal bush for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and as directed.
Taking out defective/burnt out windings of ceiling fans of various makes of size 1200 to 1400mm sweep working on 230/250 volt single phase AC supply and rewinding with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish' baking up, reassembling the fan, testing including replacement of connector, flexible wire of suitable size, complete all as directed.
Taking out rusted/defective down rod and supply and fix new down rod of medium grade GI tubing 15mm bore having holes and threading at ends as per site requirement complete all as specified and as directed.
Taking down exhaust/wall mounted fans of any type and size after disconnecting the connections from existing ceiling rose to connector and transportation to work shop, cleaning externally, dismantling and examining the rotor, stator, bearings/bushes, winding etc for serviceability and repairing/replacing the defective parts subsequently oiling, greasing assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging/fixing and connecting the electrical connections, testing for noise free smooth running etc; complete all as as directed.
Painting of exhaust fans along with blades of any make/model of size 225 to 380mm sweep with spray paint black/existing colour supper enameled paint, writing MES No. in 20 mm letter size with white paint etc including prepation of old painted surface, complete all as specified and as directed.
Description all as per item No. 78 above but of size 450mm sweep.
Taking out defective/worn out bearing of any make and supply and fix new bearing suitable for various makes of exhaust fans of size 225/380mm sweep complete all as specified and as directed.
Description all as per item No. 80 above but of size 450mm sweep.
Taking out defective capacitor and supply and fix new capacitor of 4 mfd of approved make for various makes of exhaust fans complete all as specified and as directed.
Taking out defective/burnt winding of exhaust fans of various makes of size 225 to 380mm sweep working on 230 to 250 Volts, single phase, AC supply, transporting to workshop and rewinding with supper enameled new copper wire of appropriate gauge including varnishing with good quality varnish baking up, reassembling the exhaust fan, testing, replacement of connector, flexible copper wire of suitable size complete all as specified and as directed.
Description all as per item No-83 above but of size 450mm sweep.
Taking down unsv RO water purifier system, servicing the same complete by means of cleaning all pipes replacing unsv PVC connections, joints, elbow etc complete upto the entire satisfaction of work, complete all as specified. Note :- Replacement of unsv parts apart from mentioned above will be measured and paid seperately.
Replacement of pressure booster pump suitable for any type/capacity of RO, 24 volt DC, as per existing make all as specified & direct by Engr-in-charge.
Replacement of primary sedimenation filter suitable for any type/capacity of RO, as per existing make all as specified & direct by Engr-in-charge.
Replacement of post silver activated carbon cartridge for improvement of water taste, as per existing make all as specified & direct by Engr-in-charge.
Replacement of membrane catridge suitable for any/capacity of RO water purifier Make:- aquagauard or equivalant etc all as specified & directed.
Replacement of SMPS 24 volt DC adopter suitable for any/capacity of RO water purifier as per existing make, complete all as specified & directed.
Replacement of Solenoid switch (water level controler) suitable for any/capacity of RO water purifier as per existing make all as specified & directed.
M/S KIRAN CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .