Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹23.2 L+₹26,990 (1.18%)Rejected-Finance OPPOSITE RADIO STATION TOWER TILAK NAGAR SAGAR ROAD BIKANER 334001 RAJASTHAN | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance DUE TO NOT LOWEST | |
| 3 | L3₹23.6 L+₹60,640 (2.64%)Rejected-Finance B 22 152 STREET NO 1 14 BABA FARID NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance DUE TO NOT LOWEST | |
| 4 | L4₹23.9 L+₹94,528 (4.12%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT LOWEST | |
| 5 | L5₹25.2 L+₹2.2 L (9.73%)Rejected-Finance | L5 | Rejected-Finance DUE TO NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Bikaner
GE North Bikaner
REPAIR TO SEWAGE LINE CLEANING OF SEPTIC TANKS SOAKAGE WELL CHAMBER REPAIR AND COVER UNDER AGE BR I AND ASCON NODE BIKANER AT MIL STN BIKANER
2022_MES_554711_1
GE (N) BKN TOKEN NO 54 /2022-2023
Open Tender
Civil Works
Item Rate
335 days
BIKANER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹60,000
Yes
14 Dec 2022
27 Sept 2022
1 Nov 2022
27 Sept 2022
25 Oct 2022
11 Oct 2022
Amount
Cleaning/removing blockage of EWC, IWC, Gully Trap, includding P or S Traps of any description, by rodding, by pressure pumps of any description or by any other manchical equipments in any positions or locations at all Military Station Bikaner under AGE B/R I area till complete satisfaction of Engr -in - Charge.
Cleaning/removing blockage of floor trap, nahni trap, wash basins, sinks etc. including waste pipe or waist coupling etc. by manually or mechanically till complete satisfaction of Engr -in- Charge.at all Military Station Bikaner
Cleaning/removing blockage of sewer line (SGSW/RCC/CI) of dia100/150/200mm etc.of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage line and repair the same if required including taking off and re-fixing manhole covers complete all as specified and directed by Engr -in- Charge at Military Station Bikaner
Cleaning/removing blockage of manholes of any size or depth upto 1.0 m in foul condition by manually or mechanically by roding or any other mechanical equipments till the entire satisfaction of Engr -in- Charge. All solid/semi solid sludge is to be deposited out side the defence land or depositing where directed by Engr-in-Charge including taking off and re-fixing manhole covers complete all as specified & directed.at allMilitary Station Bikaner
Cleaning/removing blockage of manholes of any size or depth upto 1.0 m to 1.50 m in foul condition by manually or mechanically by roding or any other mechanical equipments till the entire satisfaction of Engr -in- Charge. All solid/semi solid sludge is to be deposited out side the defence land or depositing where directed by Engr-in-Charge including taking off and re-fixing manhole covers complete all as specified & directed.at allMilitary Station Bikaner
Cleaning/removing blockage of manholes of any size or depth upto 1.5 m to 3.00 m in foul condition by manually or mechanically by roding or any other mechanical equipments till the entire satisfaction of Engr -in- Charge. All solid/semi solid sludge is to be deposited out side the defence land or depositing where directed by Engr-in-Charge including taking off and re-fixing manhole covers complete all as specified & directed.at allMilitary Station Bikaner
Cleaning/removing blockage of manholes of any size or depth 3.00 m and above in foul condition by manually or mechanically by roding or any other mechanical equipments till the entire satisfaction of Engr -in- Charge. All solid/semi solid sludge is to be deposited out side the defence land or depositing where directed by Engr-in-Charge including taking off and re-fixing manhole covers complete all as specified & directed.at allMilitary Station Bikaner
De-watering from septic tanks/soakage wells by honey sucker machine and also removing of all wastes, solid or liquid of any description to the location as specified and directed by Engr -in- Charge. ( Note : The rate includes for carrying and empting of sewage water out side defence land or as directed by Eng-in-charge w/o any extra cost to the Govt)
De-sluding by removing of solid/semi solid sludge from existing septic tanks/soak wells of any depth and capacity in foul conditions including taking and placing in position the cover slabs of any description including cement sand mortar 1:4 if required . Removal of sludge/solid contents will be remove to any place out side defence land or depositing where directed by Engr-in-Charge all as specified and directed. at all ,Military Station Bikaner.(Note : The sludge shall have to be disposed off in trenches duly excavated and covered after sprinkling of chemicals and cover with excavated soil and removal of extra soil without any extra cost to govt)
Cleaning/removing blockage of EWC, IWC, Gully Trap, includding P or S Traps of any description, by rodding, by pressure pumps of any description or by any other manchical equipments in any positions or locations at all Escon nods Viz Udasar, Jamsar, Lakhusar, Amarpura, Marh, Bajju till complete satisfaction of Engr -in - Charge.
Cleaning/removing blockage of floor trap, nahni trap, wash basins, sinks etc. including waste pipe or waist coupling etc. by manually or mechanically till complete satisfaction of Engr -in- Charge.at all Escon nods Viz Udasar, Jamsar, Lakhusar, Amarpura, Marh, Bajju
Cleaning/removing blockage of sewer line (SGSW/RCC/CI) of dia100/150/200mm etc.of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage line and repair the same if required including taking off and re-fixing manhole covers complete all as specified and directed by Engr -in- Charge.at all Escon nods Viz Udasar, Jamsar, Lakhusar, Amarpura, Marh, Bajju
Cleaning/removing blockage of manholes of any size or depth in foul condition by manually or mechanically by roding or any other mechanical equipments till the entire satisfaction of Engr -in- Charge. All solid/semi solid sludge is to be deposited out side the defence land or depositing where directed by Engr-in-Charge including taking off and re-fixing manhole covers complete all as specified & directed.at all nods Viz Udasar, Jamsar, Lakhusar, Amarpura, Marh, Bajju
De-watering from septic tanks/soakage wells by honey sucker machines and also removing of all wastes, solid or liquid of any description to the location as specified and directed by Engr -in- Charge. ( Note 1. : Waists and Solid will be pay as deluging in item No 6 under.)at all nods Viz Jamsar,Lunkarnsar,Mahajan,Lakhusar,Motigarh,Rd 498,Pugal,Amarpura,Marh, Bajju.( Note 2. The rate includes for carrying and empting of sewage water out side defence land or as directed by Eng-in-charge w/o any extra cost to the Govt)
De-sluding by removing of solid/semi solid sludge from existing septic tanks/soak wells of any depth and capacity in foul conditions including taking and placing in position the cover slabs of any description including cement sand mortar 1:4 if required . Removal ofwill be remove to any place out side defence land or depositing where directed by Engr-in-Charge all as specified and directed. at all nods Viz Jamsar,Lunkarnsar,Mahajan,Lakhusar,Motigarh,Rd 498,Pugal,Amarpura,Marh, Bajju. .(Note : The sludge shall have to be disposed off in trenches duly excavated and covered after sprinkling of chemicals and cover with excavated soil and removal of extra soil without any extra cost to govt)
Demolition of brick masonry built in CM. all as specified and the item credited from the demolilition is used to filling the manhole/Sokage well area and levelled to the surrounding area.
Demolition of cement concret unreiforced of any description over roof slab complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quions arches pillars etc
Demolition of cement conc. Reinforced as in roof slab , beams, chhajas and similar suspended work reinforcement cut as required to facilitate demolition.
Demolition of stone slab as in roofs suspended floors ,roofs any thickness jointed in any mortar comp all as spcd.
Taking down cement plaster of any desc incl.raking out joints hacking for key scrubbing down with water etc.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 100 to 200mm dia complete all as specified.
Excavation in trenches n exc 1.50m wide and not exc in 1.50m in depth for foundation etc. or for shafts wells cesspits manholes etc not exc 10sqm on plan and not exc 1.50m in depth and getting out in soft soil
All as per item No above but exceeding 1.50m and not exc.3m in depth.
Excavation over area n exc. 1.5 m deep and getting out in soft soil
Excavation over area exc. 1.5 m but n exc 3 m deep and getting out in soft soil
Excavation over area exc. 3 m but n exc 4.5 m deep and getting out in soft soil
Excavation over area exc. 4.5 m but n exc 6 m deep and getting out in soft soil
Excavation over area exc. 7.5 m but n exc 9 m deep and getting out in soft soil
Returning filling in, including ,spreading levelling ,watering and well ramming in layers not exc. 25cm in soft/loose soil.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point in soils
Removing excavated material exc. 500m and depositing where directed at a level not exc. 1.50m above the starting point in soils
Taking down carefully existing AC/PVC/CI soil/waste /vent pipe and fittings (100/75/50mm bore of any pattern)incl.all fittings such as bends ,shoes,sockets junctions swan laid on floors /wall or in trenches provided with lead cement joint comp.all as spcd.
M&L for 100mm thick concrete 1:4:8 type D-2 using 40mm graded stone agg.as in packing under and haunching against the sides of pipes after they are laid and tested in 150mm dia of pipes.
M&L for salt glazed stone ware pipes laid in trenches for grade A.150mm bore internal dia and jointed as specified.
M & L 200mm dia Salt-glazed stoneware drain pipes laid in trenches and jointed as specified.
M&L for DWCPE ppe 150 mm dia laid in trenches , incl earth work removal , returning filling , Jointing incl testing along with necessary fittings , complete all as per manufactrers instructions laid on pcc 1:3:6 type C2 using 40 mm graded stone aggregate incl packing under haunching against sides of pipe laid all as per IS 16098-2013.
M&L for DWCPE ppe 200 mm dia laid in trenches , incl earth work removal , returning filling , Jointing incl testing along with necessary fittings , complete all as per manufactrers instructions laid on pcc 1:3:6 type C2 using 40 mm graded stone aggregate incl packing under haunching against sides of pipe laid all as per IS 16098-2013.
M & L for 150mm thick Cement concrete 1:3:6 type C-2 bed to drain pipes including packing under, and haunching against the sides of pippe after they are laid and tested; in 200mm dia pipe.
M&L hardcore n exc 63 mm guage depositing and levelled in layers n exc 15 cm thick watered and rammed to true surface complete all as specified
M&L for hardcore of broken brick or of gauge n exc 63mm, deposited, spread and levelled in layers for back filling for filteration not exc 15cm thick, watered and rammed to a true surface.
M&Lsub class B honey comb brick work for soak well wall in CM 1:3
M&L for brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 comp all as specifeid.
M&L for rendering 15mm thick on fair faces of brick or conc. Surfaces in cement mortar 1:4 mixed wih water proofing compound as per manufacturers instructions finishing the surface even and smooth without using extra cement.
Suply only liquid water proofing compound
M&L Jodhpur stone of roof slab self faced 7.5cm to 10 cm thick 25 to 35 cm wide hoisted and set jointed and grouted in cement and sand mortar 1:6 comp.all as specified.
M&L PCC 1:3:6 type C-1 using 20mm graded stone agg. ,50mm thick as in floors over stone patti roof slab finished the surface even and fair comp.all as specified.
M&L Providing cement conc. as in surface channels and drains type B1 1:2:4 using 20mm graded agg and inside the man holes.
M&L for PCC 1:3:6,type C-2 using 40mm graded crushed stone aggregate as in fdn filling of surface channel and drains
M&L PCC 1:4:8 type D-2 using 40 mm graded stone agg in foundation filling and mass concrete complete
M&L PCC 1:2:4 type B-2 using 40 mm graded stone agg in foundation filling and mass concrete complete
M&L precasted SFRC manhole/Drain cover with frames square/round size as per ground requirement provided with suitable mild steel rims and easy lifting hooks of medium duty 10 MT as per IS 12592 pt I and as per directed by Engr-in-charge
M & L RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast cement concrete, manhole covers/ Drain cover(vibromechenically floated ) including all use of forms, moulds or machine moulds and setting the blocks, slabs etc in cement mortar 1:4,complete all as specified and directed. (Reinforcement shall be measured and paid separately under respective item of schedule "A") .(Note : Curing arrangements shall have to be made by contractor at its own with out any claim on cost incurred)
S&F mild steel TMT bar 8 to 10 mm dia and over as in reinforcement, cut to length, bent to shape etc including binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Cutting into existing manhole for connecting new drain making good to pipe and rendering cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement conc. 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm dia of pipe..
M&L for coloured non skid ceramic tiles 300 x 300 x 7mm thick in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles and including 20mm thick screed bed in CM 1:6 and incluiding dismantling the existing.
All as per above but white glazed tiles 450mm x 300mm x 7mm thick including 10mm thick screed bed in CM 1:4 on vertical surfaces
S&F Vitreous china wash down water closet white orissa pattern of size 550x440mm including integral foot rest excluding flushing cistern and flush pipe) incl. P or S trap comp all as specified andfixed in repair ( Make : Hindware,Cera,Parryware)
M&L Cement conc. Type E-2 1:5:10 using 40mm graded stone agg in foundation filling and mass conc. Complete
S&F in repairs vitereous china wash down water closet (pedestal pattern) white including plastic seat cover, black, closed top pattern with flat, bottom and cover and MS CP, of alum hinging device complete ( Make : Hindware,Cera,Parryware)
S&F in repairs plastic water closet seat cover , coloured, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete
S&F in repairs PVC flushing cistern 10 ltrs capacity incl flushing pipe and connections complete. as approved by Engineer in charge,low level, white with inlet, ball valve ,complete including connection to pipe all as specified.
S&F 15mm bore PVC connection with PTMT nuts length 450 mm
S&F in repairs PVC(SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed to walls.
All as per above but 90mm bore
All as per above but 75mm bore
S&F in repairs PVC(SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches
All as per above but 75mm bore
S&F in repairs PVC(SWR) floor trap with gratings including jointing with solvent cement 75mm dia complete
M&L for Salt glazed stoneware gully traps of size 150 mm x 150 mm, square or round mouthed, type ‘P’ complete.
S&F PVC(SWR) bend any radius of 110mm bore jointed with solvent cement complete
S&F PVC(SWR) junction double (single T) of size 110mm bore jointing with solvent cement complete
M&L PVC(SWR) reducer 110mm to 75mm bore jointing with solvent cement.
M&L PVC (SWR) bend any radius of 75mm bore
S&F 75mm dia of cast iron soil,waste and vent pipes in any length with or without ears fixed to wall in repairs
S&F 100mm dia of cast iron soil,waste and vent pipes in any length with or without ears fixed to wall in repairs
S&F 75mm dia of cast iron soil,waste and vent pipes in any length with or without ears laid trenches or floor in repairs
S&F 100mm dia of cast iron soil,waste and vent pipes in any length with or without ears laid trenches or floor in repairs
S&F 50 mm dia of cast iron soil,waste and vent pipes in any length with or without ears laid trenches or floor or wall in repairs
S&F clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall Clamp 100 mm
- ditto but Clamp 75 mm
-ditto- Clamp 100 mm
S&F100 mm cast iron sanitary connection socket to fit WC out-let fixed in repair
S&F100 mm cast iron bossed pipe basinand bath connector single (for one pipe system) fixed in repair
S&F100 mm cast iron bossed pipe basinand bath connector double (for one pipe system) fixed in repair
S&F of 75mm dia cast iron bends as in repairs
S&F of 100mm dia cast iron bends as in repairs
S&F Cast ron Lids for oval; acess 75 mmfixed in repairs
S&F Cast ron Lids for oval; acess 100 mmfixed in repairs
S&F of 75mm dia cast iron branch piece (equal or unequal ) single ordinary or inverted (spigot or socket type) as in repairs
S&F of 75mm dia cast iron branch piece (equal or unequal ) double ordinary or inverted (spigot or socket type) as in repairs
S&F of 100mm dia cast iron branch piece (equal or unequal ) single ordinary or inverted (spigot or socket type) as in repairs
S&F of 100mm dia cast iron branch piece (equal or unequal ) double ordinary or inverted (spigot or socket type) as in repairs
S&F of 75mm dia cast iron sockets (double) collars as in repairs
S&F o 100m dia cast iron sockets (double) collars as in repairs
S&F of 50 mm dia cast iron vent cowls as in repairs
S&F of 75 mm dia cast iron vent cowls as in repairs
S&F of 100 mm dia cast iron vent cowls as in repairs
M&L preparing old plastered surfaces of any description and applying two coats of synthetic enamel paint complete all as specified and directed
S&F writing letters or figures (Block, Roman,Utalic or indian) n exc 30 Cm hegh complete
M & L Cutting existing steel tubing for alterations or additions without taking down for 40 or 50 (Each cut measured) complete all as specified.
M & L 20 mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
S&F 20mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
Providing and fixing automatic/manually perated flushing arrangement for sewer line in masonary chamber of size 1000mmx1000mmx1000mm for the smooth function of sewage line including all fittings, over flow pipe and suitable connection to existing sewage line as per drawing andf directed by GE. Note:- Plaster work in chamber should be waterproof by using Dr. Fixit Pidifin 2K.
M S GROUP
HARPREET SINGH CONTRACTOR
G R POWERS
m/s gharu constrution company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .