Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 CrAccepted-AOC | ₹26.4 Cr Quoted ₹26.7 Cr | L1 | Accepted-AOC Being L1 and Found Reasonable |
| 2 | L2₹27.1 CrRejected-Finance | ₹27.1 Cr | L2 | Rejected-Finance Being other than L1. |
| 3 | L3₹28.2 CrRejected-Finance | ₹28.2 Cr | L3 | Rejected-Finance Being other than L1. |
| 4 | L4₹28.5 CrRejected-Finance | ₹28.5 Cr | L4 | Rejected-Finance Being other than L1. |
| 5 | L5₹30.6 CrRejected-Finance | ₹30.6 Cr | L5 | Rejected-Finance Being other than L1. |
Tender Value
₹25 Cr
EMD Value
₹15 L
Closing Date
8 Jun 2021, 6:00 pmClosed
CE Lucknow Zone
HQ CE Lucknow Zone, 17, cariappa marg, Lucknow 226002
PROVISION OF OTM ACCN AND DISPERSAL AREA AT LUCKNOW CANTT
2021_MES_416754_1
CELZ/LKO/T-04 of 2020-21
Open Tender
Civil Works
730 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹3,000
GE(P) Lucknow
₹15 L
Yes
30 Jul 2021
29 Jan 2021
10 Jun 2021
29 Jan 2021
8 Jun 2021
25 May 2021
11 Feb 2021 - 22 Feb 2021
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply)
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Compound Wall, Fencing & Gate)
Total amount of Sch 'A' Part VI (Sewage Disposal)
Total amount of Sch 'A' Part VII (Road, Path and Culvert)
Total amount of Sch 'A' Part VIII (Area Drainage)
Total amount of Sch 'A' Part IX (Solar Water Heater)
Total amount of Sch 'A' Part X (External Water Supply)
Total amount of Sch 'A' Part XI (Lightening Protection)
Total amount of Sch 'A' Part XII (External Electrification)
Total amount of Sch 'A' Part XIII (Conduit for Telephone/TV)
Total amount of Sch 'A' Part XIV (Demolition/Dismantling)
Total amount of Sch 'A' Part XV (Rain water harvesting)
(Provisional sum of Rs 5080165.00) for :- (i) Consturction of 7.50 mtr long, 450 mm dia RCC class NP-3 hume pipe culverts with brick masonry including necessary earth work complete all as specified and shown in Drg No TD-575. - (06 Nos) (ii) Provn of Septic tank for 50 users, RCC M-30 design Mix including necessary earth work complete all as shown in Drg No TD/750, Sheet 1/2 & 2/2 - (03 Nos). (iii) Provn of Septic tank for 150 users, RCC M-30 design Mix including necessary earth work complete all as shown in Drg No TD/750, Sheet 1/2 & 2/2 - (02 Nos). (iv) Provn of Soak well 1.80 meter dia and 3.0 meter depth with and including top ring M-25 design mix ,RCC cover of M-25 concrete / SFRC cover complete all as shown in Drg No TD/576, Sheet 1/2 & 2/2 - (06 Nos). (v) Provn of Soak well 2.40 meter dia and 3.0 meter depth with and including top ring M-25 design mix ,RCC cover of M-25 concrete / SFRC cover complete all as shown in Drg No TD/576, Sheet 1/2 & 2/2 - (04 Nos). (vi) Provn of Basketball ground complete all as specified and shown in Drg No TD-638. - (01 Nos)
Schedule 'A' Part - XV (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 signifies this fact only.
INTERNAL ELECTRIFICATION Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete for one 5 pin 5 Amp switch socket outlet point on same board with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and pVC conduit not less than 20mm in roof/floor slab and ceiling pressed GI concealed terminal boxes not less than 1.6mm thick of required size and with top cover 3mm thick of plastic laminated sheets of required colour complete including 1.5 sqmm PVC FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth-green with all accessories complete all as specified and directed
Point wiring complete for one bell/buzzer/socket point controlled by one push button on the same board with other switches, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete for One light point controlled by two way switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost.
Supply and fixing LED light fitting,1X20 Watt,(min 120 lumem/watt) 230 volts, 4 feet ,energy efficient type,ceiling /wall mounting, Box type fitting, with epoxy powder coated CRCA sheet housing with reflector cover channel Retro fit type LED Tube rode with Batten,complete with all accessories internaly prewired including including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduit from celling rose to tube light fitting complete with ISI Marked complete all as specified and directed. .
S&F energy saving 2 feet LED batten with 9/10 Watt LED with a nominal system output of 120 lumen/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000Kintegrated high efficiency LED drive>85% non corrosive complete all as specified and directed.
Supply and fixing 50 watt ,5700K LED security Flood light made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,mounted on top of the pole with cap type bracket having lenght not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light . including PVC insulated three core 23/0.0076 copper cable and including suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed. Make Havells cat part No- ILIOSBAYPLUS HBP 50WLED8575P90DTOPC or techocommercially equivalent of makes mentioned in make list.
Supply and fixing Ceiling mounded / Suspended architectural decorative down light LED 14/15 Watt system wattage constructed out of pressure die cast aluminium housing and premium quality PMMA diffuser having luminaire efficacy> 120 lum/W and provided witth surge supressor of 2.5 Kv complete all as specified and directed. Make LCRP-15- CDL of Crompton / LD80-131-XXX-60-SM of Wipro/SM251CLED16S-6500PSU WH of Philips/ENDURANEOHESURFACEDLS15WLDED857S of Havells or techocommercially equivalent of makes mentioned in make list.
Supply and fix decorative wall mounting Engment light chrome finish fixture with textured glass including 11 watts Red and Green LED lamp complete all as specified and directed. Make Havells cat part no LHFOFDC1TZ1C040 or equivalent model of makes mentioned in Appendix 'D
Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 250 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Havells Model -Ventil Air -DX White of havells or equivalent model of makes mentioned in Appendix 'D'.
Exhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model No Supreme Dlx or equivalent model of makes mentioned in Appendix 'D'.
Supply and fix decoraive wall mounting finish fixture with opal glass diffuser suitable for LED incandecent candle lamp Cat part LHJE01106499 of Havells .or equivalent model of makes mentioned in Appendix 'D
Supply and fix bed site LED light 20 watts recessed/Wall mounted LED wall min 120 Lum/Watts washers, tillyed 70 degree outwards and swivels 360 degree to offer the best lumination on the wall /floor//Retailer displays all as specifed and directed. Make - Philips 48042 3-watt LED Bed side light or equivalent model of makes mentioned in Appendix 'D
Energy saving pressure die-cast aluminium IP 66 roadway luminaire with high power 20 WATT LED with a nominal system output of 85 lum/watt(min) with PF not less than 0.9 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia/suitable dia light grade bend to shape security light fitting with necessary MS clamps 35/40 mm wide and 6 mm in thickness in suitable length not more than 30 CM and Max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminium paint including nuts, bolts and washers complete all as specified and directed. Make -Cat part LR02-261-XXX-57-XX of Wipro/ LST-20-CDL-M/NL of Crompton or equivalent model of makes mentioned in Appendix 'D'.
Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 complete all as specified and directed.
Ceiling fan 1200 mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to Connector including connector 2 way/3way and provn of 3 core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long long for connection complete all as specified and directed. Make: Bajaj model Electra 50 or equivalent model of makes mentioned in Appendix 'D'.
Ceiling fan 1400mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to including fan connectors and provn of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified and directed.
Supply and fix Inverted pyramid tripod type 10 Watts led bollarad with soft 360 degree light 120 Lum/Watt with IP 65 protection, Resitance to corrosion better optics for uniform distribution. Cat No LBSL 1- 10 - CDL , Make Crompton or equivallent , Bajaj, Havells, L&T . Complete all as specified and directed.
MCCB 4 pole,415 V ,AC fixed thermal & fixed magnetic setting 125 amps with breaking capacity 10 KA . Ics=100% complete all as specified and directed.
MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCCB and with enclosure blank plates for unused way suitable for 4 ways complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 6 way complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.
MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed.
MCB single pole 6 to 32 Amps rating 'B' Series,10 KA 240 Volts, AC complete all as specified and directed.
MCB single pole and neutral 40 Amps to 63 Amps rating 'B' Series,10 KA 240 Volts, AC complete all as specified and directed.
MCB single pole and neutral 6 to 32 Amps rating 'B' Series, 10 KA, 240 Volts, AC complete all as specified and directed.
Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- (i) Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit .(ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost
Submain wiring with two core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including one 4 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- (i) Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost
Submain wiring with two single core 2.5 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 2.5 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- (i)Two single core 2.5 sqmm copper conductor, one run PVC conduit and one run of 2.5 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost
S & F suspended light fitting 2x20 watt LED type TMC 501 rail for T LED lamp with hanging chain /rod with connected accessories including PVC insulated three core 23/0.0076 copper cable complete Make: Cat part TMC 501 p2xT-LED 22 watt P 3242/IGP162LT8-16 of Crompton or all as equivalent model of makes mentioned in Appendix 'D complete all as specified and directed
S&F Polycorbonate T8 tube with in-built driver with metal heat sink double side connection Make: Cat part LT8-20-865-(2) of Crompton or equivalent model of makes mentioned in Appendix 'D complete all as specified and directed
S & F suspended light fitting 30 watt LED type well glass polycarbonate in PDC Pressure die cast aluminium housing finless design and excellent thermal management offering high durability and superior performance with energy saving and having efficiency of 110Lm/w in glass protection of IP66 with hanging chain/rode with connected accessories including PVC insulated three core 23/0.0076 copper cable complete all as specified and directed
S & F Electronic Energy meter 10-60Amps Three phase 4 wire 440 Volts with Polycarbonate enclose/Meter box complete all as specified and directed
S & F Flame proof 18/20 Watt LED light fitting 4 feet single phase, 240 Volts complete all as specified and directed
S & F Flame proof Exhaust fan 450mm sweep single phase, 240 Volts. complete all as specified and directed
S & F Flame proof switch single phase, 240 Volts complete all as specified and directed
S & F Flame proof switch socket combination 6/16 Amps, 240 Volts complete all as specified and directed
M & L for flame proof point wiring complete for one light / fan controlled by one flame proof switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia steel conduit with all accesories including flameproof junction box as required concealed in wall and steel conduit including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed. Note :- In case of roof / ceiling heavy duty 20mm steel conduit shall be used without any extra cost
M & L for flame proof point wiring complete for one socket point controlled by one flame proof switch with PVC insulated and unsheathed FRLSH cable 2.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia steel conduit with all accesories including flameproof junction box inspection bend as required concealed in wall and steel conduit including 2.5 Sqmm PVC FRLS unsheathed FRLS cable 2.5 Sqmm (nominal area) multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty 20mm steel conduit shall be used without any extra cost
M & L for point wiring complete for one light / fan / exhaust fan controlled by one modular switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessoeries complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost
M & L for point wiring complete for one 5 Pin 6 Amp modular socket outlet point on an indpt with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessoeries complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost
M & L for point wiring complete for one bell / buzzer point controlled by one modular bell push button on the same board with other switches or indpt with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessories complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost
M & L for point wiring complete for one light point controlled by two way modular switches with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 1.5 Sqmm PVC FRLS unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessoeries complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost
M & L for point wiring complete for one 5 Pin 16 Amp modular socket outlet point on an indpt board with PVC insulated and unsheathed FRLS cable 2.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20mm in roof / floor slab and ceiling, and including modular concealed metal flush boxes not less than 1.6 mm thick of required size, inner plate , outer plate, top cover in all accessory, including 2.5 Sqmm PVC FRLS unsheathed FRLS cable 2.5 Sqmm (nominal area) ISI marked, multistranded copper conductor single core for earth wire to the common earth and connecting earth dolly including colour coding of cable shall be phase - Red, neutral - Black and earth – green with all accessoeries complete all as specified and directed ” Note :- In case of roof / ceiling heavy duty PVC pipe shall be used without any extra cost
S & F Modular switch 2 way 6A, 1 module, 240 Volts complete all as specified and directed
S & F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed
“ S & F Modular switch 1 way 16A, 1 module, 240 Volts. complete all as specified and directed
S & F Modular socket 6 A, 5 Pin combined 2 module complete all as specified and directed
S & F Modular socket 6/16 A, 5 Pin combined 2 module complete all as specified and directed
S & F Modular bell push Two module flush type 6 Amp complete all as specified and directed
S & F Modular Fan step regulator, 120W 2 module as required complete all as specified and directed.
S&F ventilating fan of size 225/250mm sweep including fixing of louver shutter with frame on the exhust side (outer surface of wall including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling complete all as specified and directed
S & F blanking plate for one module complete all as specified and directed
S & F Decorative post top 40 watt LED with diffuser complete all as specified and directed. Make-Cat Part No LPTO -40-CDL or equivalent model of make in Appx D
INTERNAL WATER SUPPLY CP wall mixer of size 15mm, 3 in 1 with hand shower complete all as specified and directed.
Health faucet (1.5m tube) with hook (hand spray) with CP body , complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 leavers and in duplicate key (Make - Godrej ) or equivalent make as approved by GE complete including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Disconnecting and taking up or down old existing GI tubing of bore 25mm/20mm and connections of any description/grade and in any position including valve in trenches/under floors/on walls etc including connected fittings/ accessories complete all as directed and specified.
Disconnecting and taking up or down old existing GI tubing of bore 100mm/80mm and connections of any description/grade and in any position including valve in trenches/under floors/on walls etc including connected fittings/ accessories complete all as directed and specified.
Disconnecting and taking up or down old existing Gl tubing of bore 50mm/40mm mm and connections of any description/grade and in any position in trenches/under floors/on walls etc including connected fittings/ accessories complete all as directed and specified.
Laying only old GI water tubing of sizes upto 100mm bore and connections of any description/any grade and in any position obtained from taking downon new route in trenches with using new fittings i.e. bends/Tee/ sockets/ reducers/elbow etc. including cutting/making new threads at the ends of old pipes complete all as specified and directed:
EXTERNAL ELECTRIC SUPPLY : Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply installation, commissioning and testing of transformer copper wound step down 160 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed naturally cooled complete in all respect and all other standard accessories etc complete all as specified and directed with following accessories consisting as per details mentioned in Annexure - A to BOQ. NOTE :- (i) Annexure- A to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. (iii)Transformer shall be platform mounted as per TD No 699 (Amedment of TD Drg No 699) , chain link fencing of size 5125mm x 5125mm x 2000mm(Height) to be provided around the transformer fondation with gate as per TD in lieu of flat vertical bar and the rates quoted against this item shall be deemed to include for this provision. (iv) The contractor shall arrange factory visit as detailed by accepting officer to check the above system.
Supply, laying, jointing, testing and commissioning of HT XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium stranded conductor 11 KV 'Earthed' grade conforming to IS 7098 (Part II) through pipes/ducts/trenches/under floor/under road of size 95 Sqmm 3 core complete all as specified and directed.
HT pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two GI washer and one GI nut of size 150 mm height, 150 mm dia for 11000 Volt grade complete all as specified and directed.
Lightning arrestor non linear resistor type or expulsion type conforming to IS-3070 (Part-I) complete line discharge or transmission class - 2 nominal discharge current 10 KA & high discharge 100 KA assembly suitable for 11 KV incl all clamps, nuts, bolts & washers and connecting to earth with 32x6 mm size GI strip complete all as specified and directed.
Supply installation, commissioning and testing of switch air break gang operated HT 11 KV triple pole with 12 Nos insulator of 200 amp rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and steel frame mechanically (horizontally), vertically operated with operating rod of 25 mm bore medium grade GI pipe of suitable length, worked from ground level and with locking arrangement flat iron clamp of size 50 mm x 6 mm including MS channel of suitable size and length for fixing GOD/DO including bolts, nuts, and washers etc. complete all as specified and directed. Note:- MS work shall be measured and paid separately.
Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
LED street light Integral type luminaire 70/75 watt , comprising of PDC housing , enclosed with toughened glass cover suitable for & including suitable size GI pipe not less than 1.2 mtr long bent to shape bracket , Ingress protection-66 complete all as specified and directed. Make : Surya cat part No. SLE UL 72W IP-66 LXN or equivalent model of makes mentioned in Appendix 'D'.
S&F polycarbonet Junction box of size 250 x 200 x 150 mm with 01 No MCB SP 6 Amp, 02 Nos aluminium bus bar of size 25 mm x 3 mm fixed on porcelain support with hinged cover and locking arrangement fixed to pole complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and fix LED Flood light 170 W , IP 66 complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 185 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 70 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 6 Sqmm 2 core complete all as specified and directed. Note : - Wherever road crossing occurs drill the road to horizontally and bore the GI pipe under road for passing the cable under road. Cost for the same shall be deemed to be included in rate quoted.GI pipe sall be measured and paid seperately
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing strip beyond 7.5m shall be measured and paid separately.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick,latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc (Main Panel) and comprising of the following accessories consisting as per details mentioned in Annexure - B to BOQ. NOTE :- (i) Annexure- B to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick/latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc, ( For PANEL No1.) and comprising of the following accessories consisting as per details mentioned in Annexure - C to BOQ. NOTE :- (i) Annexure- C to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick,latest CPRI approved thick duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc( For Panel 2) and comprising of the following accessories consisting as per details mentioned in Annexure - D to BOQ. NOTE :- (i) Annexure- D to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, factory made, out door type Panel board made out of MS sheet of size 3.15 mm thick , latest CPRI approved duly with powder coated & mounted on an angle iron frame,made out of 50 x50 x6 mm angle iron frame, 90 cm hight, duly fixed with PCC etc and comprising of the following accessories consisting as per details mentioned in Annexure - E to BOQ. NOTE :- (i) Annexure- E to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Solar street light system including galvanised steel pole with 18 watt LED type with lead acid 12 volt, 100 AH, battery, automatic ON-OFF system, charge controller complete & installation, commissioning including material and labour for masonry work complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with and including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
LED Flood light 200 W, maunually operated, suitable for mounting of search-lights inside/outside of watch tower cabin. It is made of iron & steel and designed so that the search light can be rotate one full round around its vertical axis and could be locaked at any position. Additonally having PVC castor wheels at bottom for easy movement on platform with wheel locking arrangement. Standard height of tripod stand is1 Meter above the bottom including necessary electric connection complete all as specified.
Cast iron route indicator of 100 mm dia mark for HT line 11 KV UG cable fixed on 2 fit long MS angle 25x3 mm bend to shape including connected etc & PCC work painting with one coat of red oxide primer and two coat of red paint before fixings complete all as specified and directed.
Taking out old service cable after disconnecting from panel /pole and Re-laying only cable of size upto 185 sqmm and connecting of any Description /any make and in any position obtained from taking down new route in trenches with using connected accessory complete all as specified and as directed Note:-Excavation, returning filling, removal, sand and cable production cover shall be measured and paid separately on relevant item in schedule.
LIGHTENING PROTECTION : Earthing for machinery, equipments transformer body, transformer neutral, LT feeder pillar box complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not 1ess than 2. 25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32 x 6 mm thick soldered and revetted to earth plate. Complete with watering pipe 20 mm bore GI pipe (light grade) and chamber PCC (1:4:8) type D2 using 40 mm grade stone aggregate, coping shall be PCC (1:3:6) type C-1 using 20 mm graded stone aggregate and RCC (1:2:4) type B1 using 20 mm graded stone aggregate pit cover 50 mm thick reinforced with 8mm tor MS bar at 80 mm c/c both way including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No . 3 of SSR part and as specified including earth plate packed all sides with charcoal dust, common salt and testing complete including GI sheet funnel, wire mesh etc complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Protection insulator for fixing of aluminium strip complete all as specified and directed.
REFRIGERATOR/ WATER COOLER/ DESERT COOLER/SOLAR WATER HEATER : Refrigerator of capacity 192 liter to 210 liter , electric driven, single phase, 230 volt, AC, 50 Hz 5 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Refrigerator of capacity 300 upto 320 liter, electric driven, single phase, 230 volt, AC, 50 Hz 5 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully Stainless steel, electric driven single phase having storage capacity 80 Ltrs & and nominal cooling capacity 40 Ltrs per hour including connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully Stainless steel, electric driven single phase having storage capacity 40 Ltrs & and nominal cooling capacity 40 Ltrs per hour including connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed.
Metallic body desert cooler electric driven (single phase) having nominal air flow of capacity 4000 Cum/hour, including water pipe connection with PVC pipe connection having brass coupling nuts at both ends and PVC float valve and other necessary fittings (angle iron of size 40x40x6mm for stand) and electric plug connection with and including plug top 5 Amps complete all as specified and directed.
Voltage stabilizer of capacity 1.0 KVA for automatic operation, single phase naturally air cooled indoor type and designed for input voltage between 170 Volt to 250 Volt with output voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.
Voltage stabilizer of capacity 5.0 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input voltage between 170 Volt to 250 Volt with output voltage stabilized at 230 Volts with accuracy of +/- 2.5 % complete all as specified and directed.
Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 300 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 500 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed.
Supply and install of solar water heating system consisting of flat plate collector box fabricated from aluminium extruded partition by means of gas welding or brazing leak proof fully insulated with glass wool (48 Kg/Cum) with supporting structure duly paint with synthetic enamel black paint over a coat of zinc chromate Red Oxide primer provided with absorber made from copper sheet and copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minium 20 SWG thickness with puff insulation of minium 50mm girth outer including of 55-26 SWG brass socket and nipple fully insulated with glass wool with cold and hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming of IS-12933 & 12976 with necessary wiring fixed on and including required size PCC platform, cold water tank & make up water tank of capacity 100 liter per day capable to supply hot water at 60 degree celsius complete with 2 kw electric backup including PVC storage water tank three layer of capacity 200 litre for cold water of solar water heater with built up steel stage made of 25x3 mm angle frame of sufficient height complete all as specified and directed.
RAIN WATER HARVESTING (E/M Part): Plain PVC Pipe, 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed.
Screened PVC Pipe 100 mm dia bore as per IS 12818 including lowering and jointing complete all as specified and directed.
Boring 200 mm dia size bore through any kind of soil/ strata by direct rotary method up to and including 90 mtr depth complete all as specified and directed.
Reaming of bore upto 300 mm ( only for recharge well) pilot bore in any kind of soil/ strata including hard stone/boulder by means of direct rotary method complete all as specified and directed.
Pea Gravel packing of size to 10mm for trail bore of size to be designed by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete all as specified and directed.
Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/ dirty water complete all as specified and directed.
PVC end cap for 100 mm bore pipe complete all as specified and directed.
Plain PVC bend 87.5 degree for 100 mm bore pipe, with nylon wiremesh for to covering one end complete all as specified and directed.
Piezometer (Steel Tape 25 mm wide and 50 meter long with plumb) complete all as specified and directed..
BORE WELL : Drilling vertical bore 200 mm dia, from 0 to 60 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Drilling vertical bore 200 mm dia, exceeding 60 Mtr but not exceeding 200 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Drilling vertical bore 200 mm dia, exceeding 200 Mtr but not exceeding 300 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Drilling vertical bore 200 mm dia, exceeding 300 Mtr but not exceeding 480 Mtr deep below ground level at site through any kind of soil including hard stone/ boulder by means of direct rotary method and all works pertaining to pilot boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 675 mm/525mm, from 0 to 75 Mtr deep below ground level of reaming 675 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 75 Mtr but not exceeding 200 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 200 Mtr but not exceeding 300 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, exceeding 300 Mtr but not exceeding 480 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
Mild steel sheet casing plain ERW casing pipe 350 mm bore, 8 mm thickness, conforming to IS: 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed. NOTE :- (i) Length of each pipe shall not be less than 2.4 metre except where pipe length required is less than 2.4 meters. (ii) Welding shall be done through out the circumference of the pipe and coupler rings both side.
Mild steel sheet casing ERW pipe 200 mm bore, 8 mm thickness conforming to IS: 4270 -2001, ISI marked complete and lowering and fixing in position cut into different length including cutting, welding pipe, jointed and welded coupler rings throughout the circumference of after reducing socket 350mm x 200mm bore complete all as specified and directed. Note:- Reducing socket shall be measured and paid seperately.
V-Strainer (Johnson screen pipe) of size 200 mm bore of thickness 8mm and maximum length of stainer 3 mtr long/ 6 mtr long low carbon galvanised steel, plain beveled ends in built welding slots of size 0.75 mm wide uniformly distributed on surfaces and fixed in position cut into different length including cutting, welding pipe, jointed and welded coupler rings throughout the circumference of pipe complete all as specified and directed.
Mild steel reducing socket of size 350 mm x 200 mm including welding MS strip of size 40 x 6 mm (02 Nos) on each joint extended 100 mm on each side complete all as specified and directed. Note:- The wall thickness of the Socket side shall not be less than 7.04 mm.
Well cap of 350 mm dia and 8 mm thick size on top of the pipes with locking arrangement complete all as specified and directed.
Mild steel bail plug 200 mm size, 10 mm thick of 1 mtr long with MS rod 25 mm dia size welded to it at bottom bail hook complete all as specified and directed.
Pea gravel of size 3 mm to 6 mm size of approved quality as order to pack around the casing/ slotted pipes in bore well to entire depth upto ground level complete all as specified and directed.
MS flat iron (Two nos) 150 mm x 16 mm thick size clamp for holding with 350 mm bore housing pipe including casting PCC block of size 1200 mm x 1000 mm x 1000 mm in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate including 150 mm bore MS pipe two Nos each 1.5 Mtr long with cap plug and cap top for feeding pea gravel for each bore well complete all as specified and directed.
Mild Steel black column pipe 3 mtr long heavy duty 100 mm bore wall thickness 5.4 mm both end flanged with heavy duty MS flange not less than 16 mm thick screwed and welded inside and outside. The flange end making surface shall be made smooth including welding of 04 strip of 5.0 mm thick 25 mm wide and 50 mm long covering pipe and both end flanged having 08 Nos predrilled hole not less than 16 mm including rubber gasket, nut bolts and washer. Pipe shall be duly painted with anti-corrosive paint complete all as specified and directed.
Strata sample box with glass cover 3 mm thick having internal dimension 1000 mm x 600 mm x 100 mm made out of 20 mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various starta met in boring including strata chart in duplicate complete all as specified and directed.
Electric logging in pilot bore for precise delination of granular zones as also the quality of ground water including report interpretation complete all as specified and directed. Note:- Electric logging shall be carried out by any approved Govt Agency.
Chemical and bacteriological testing of sample from approved laborateory to ensure potability of water complete all as specified and directed.
Mild Steel centering guide made out of 40x6 mm and 150 mm length MS flat iron complete all as specified and directed. (Centring guide as contained in IS 2800 Part-I of 1991).
Tail piece made out of MS pipe of size 100 mm X 80 mm, 01 mtr long of wall thickness 5.4 mm both end flanged with suitable MS flange with 08 Nos pre-drilled holes of size 16 mm and welded with 04 Nos strip made out of MS plate of size 5.4 mm thick 25 mm wide and 50 mm long and flanged end pipe shall be duly painted out side only complete all as specified and directed.
Reflex valve (NRV) both end flanged of size 100mm (ISI marked) with out by pass arrangement including jointing material, commissioning and testing complete all as specified and directed.
Cast iron sluice valve of size 100 mm heavy duty both ends flanged class PN 1.6, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed.
Submersible cable PVC insulated and PVC sheathed copper conductor of size 16 Sqmm 3 core 1100 volts grade, flat cable conforming to IS 694-1977 including jointing with jointing materials and connections complete all as specified and directed.
Spply installation and testing of granular chlorination dosing pump 0-100 PSI , gear motored having output 2 GDP to 40 GDP, 230 volt, 50Hz, 44 RPM, self priming, NRV, non metalic PVC connection pipe with connecting nuts , ferrules with all accessories including 100 ltr FRP tank with 50 Kg granuals etc complete all as specified and directed.
Pressure gauge 150 mm dia of scale 0 to 7 Kg/ Cm2 with flat iron clamp of size 25X3 mm and 15 mm dia socket complete all as directed.
Supply, installation, testing and commissioning of Submersible Pump set with bronze impeller, directly coupled with motor, cast iron body pump, bronze diffusor suitable for 250mm/ 350mm bore hole tube well, water lubricated against total head 90 mtr and discharge 1150 LPM operated on AC 3 Phase 415 Volt minimum motor capacity 20 HP elect supply with and including submersible cable of size 16 sq mm 3 core, two length 5.0 mtr length all as specified and directed.
Development tube well by compressed air with minimum pressure of 10 kg/sqcm and minimum 450 CFM air compressor until sand free colour potable water up to 10 ppm is obtained to get maximum yield and discharge of bore well all as in IS 11189, Para 4.3 complete all as specified and directed. Note:- (i) Compressor, pump, pipe and other allied items will be arranged by contractor and no extra payment will be made by the Dept.
Developing tube wells by over pumping for tube well complete after development by compressor and water shall be used only after receipt of satisfactory test result as per IS, complete all as specified and directed. Note:- (i) Over pumping will be carried out by pumping the water at higher capacity i.e. not less than 50% above the yield of bore well. (ii) Cost of arranging pump and compressor is deemed to be included in the unit rate quoted.
Steel wire rope of 8 mm dia including nuts bolts, washers & suitable size of U clamp complete all as specified and directed.
ROAD, PATH / CULVERT S & F Round pipe delinators with acrylic reflectors of make 'ROAD STAR' (Gogia Plastics) model No/ Cat part No GRD-100P including fixing complete all as specified and directed.
Providing & fixing of Stimsonite Model C-80 'Cat Eye' in size of width not exceeding 130mm and height not exceeding 20mm made of strong engineering high impact resistant polymer with electronic welded lenses for retro reflective in dry and wet weather condition with bituminous adhesive along the road complete all as specified and directed.
Providing & fixing of Stimsonite Model C-80 'Cat Eye' solar type in size of width not exceeding 130mm and height not exceeding 20mm made of strong engineering high impact resistant polymer with electronic welded lenses for retro reflective in dry and wet weather condition with bituminous adhesive along the road complete all as specified and directed.
Providing & laying 2.5 mm thick hot applied thermoplastic road marking material in uniform thickness with glass beads as per clause 803 of MOST specification . The work includes cleaning of road surfaces, heating the material within the specified temperature complete all as specified and as directed.
Supply and fix in repair information and direction retro reflective sign board of size 1200mm x 1200mm as per IRC-67 1977 made of encapsulated lence type reflective sheet with letters, border, arrows etc (height of the letter 20 cm and dimention of letter of Engr-in-Charge) complete of best quality retro reflective sheet of approved colour, board made of MS sheet of approved colour, board made of MS sheet 1mm thick supported on MS square hollow section 25.4x25.4 and 4.05mm thick all around and 2 Nos pole (height of crown level and bottom of sign board shall be as per direction of GE), firmly fixed to the ground in PCC 1:2:4 type B-1 block of size 45x45x60 cm incl excavation in post holes in type of soil and applying two coats of synthetic enemal paint over a coat of red oxide zinc chrome primer on exposed surface of steel complete all as sepecified and directed.
Concertina coil 600mm dia (at stretched position), made out of hot dipped, galvanised steel wire coated with CLR anti corrosive paint, making diamond shape barbs with 18 SWG sheet, weight of each coil should not be less than 9.50 Kg, each coil should have 15 rounds and should covers 6 RM length, fixed over barbed wire at points wherever coil touches the bottom of barbed wire with the help of hog rings (14 SWG) and in between Y shaped angle iron post complete all as specified and directed. NOTE: (i) Hogging shall be fixed at a interval of 600mm centre to centre, wherever it touches with the Barbed wire wire. (ii) Overlapping of concertina coil and barbed wire shall be 300mm. (iii) Barbed wire and Y shaped angle iron post shall be measured and paid separately under respective items.
AKM CONSTRUCTION AND ENGINEERING LLP
Hariom Projects Pvt Ltd
GANGA INFRABUILD PVT LTD
Som Projects Pvt. Ltd.
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
RAGHUSONS INFRA ENGINEERING PVT. LTD
SOOD ASSOCIATES PVT LTD
Varindera Constructions Limited
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid