Assistant Engineer, KMC Electrical Sub-Division
OFFICE OF THE ASISTANT ENGINEER Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Replacement of defective voltage transformer, PLC module and RTD at sub stations within the compound of Medical College and Hospital campus, Kolkata.
2024_WBPWD_642059_1
WBPWD/AE/KMCESD/NIQ-68/23-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,000
16 Apr 2025
9 Jan 2024
29 Jan 2024
16 Jan 2024
25 Jan 2024
16 Jan 2024
Amount
VOLTAGE TRANSFORMER for Mother & Child Hub Substation: 3 LIMB EPOXY RESIN CAST DRAWOUT TYPE FEEDER CONNECTED VTR of following specification: Rated voltage: 6kV H.S.V. : 7.2kV I.L. : 20/60 kV V.F. : 1.2 CONT/1.5 FOR 30 SEC RATIO: 6000/110 VOLTS VA/CLASS LV I : 100/1.0 PHASE: 3, STAR/STAR RATED FREQUENCY: 50Hz (MAKE- Crompton Greaves Limited)
S&F of 6kV grade spout for voltage transformer
Replacement of defective temperature rise box, Resistance Temperature Detector(RTD) and necessary checking, testing & configure of transformer marshalling box of Mother & Child Hub Substation: 1250KVA Transformer (Crompton Greaves make)
Replacement of defective PLC CPU module of Green Substation LT Panel (Seimens make)
Servicing, cleaning, testing, terminal checking, configuring of entire PLC system of Green Substation LT Panel (Seimens make)
Submission of PLC drawing of Green Substation LT Panel (Seimens make)
Servicing of 2 nos 800 Amp ACB of Green Substation LT Panel (Seimens make)
S&F of Rotary handle for 4P, 415V, 400A MCCB of Green Substation LT Panel (Seimens make)
Transportation including loading & unloading from manufacturing unit to Mother & Child hub sub-station, Medical College & Hospital, Kolkata
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
JAYBEECO
T.D.K. ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .