Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹35,400Qualified Make: FLUKE
Model: Fluke-115 00 BALAJI ENTERPRISES NEW ROAD NEW ROAD RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | Make: FLUKE
Model: Fluke-115 | L1 | Qualified | |
| 2 | L1₹35,400Qualified Make: FLUKE
Model: Fluke-115 00 NEAR CITY SHINE COMPLEX BRIYARPUR 4LINE CHOWK NH 227 NEAR COMMON SERVICE CENTER TOLLA TANDASPUR NEYAMUTULLAHPUR SITAMARHI BIHAR | Make: FLUKE
Model: Fluke-115 | L1 | Qualified | |
| 3 | L2₹35,996+₹596 (1.68%)Qualified Make: FLUKE
Model: Fluke-115 C 36 1ST FLOOR HAUZ KHAS NEWDELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | Make: FLUKE
Model: Fluke-115 | L2 | Qualified | |
| 4 | Disqualified Make: Tenmars
Model: TENMARS & TENMARS 87 NO 18 1 KRC COMPLEX LAKSHMANAN STREET T NAGAR CHENNAI CHENNAI TAMIL NADU 600017 | CHENNAI | TAMIL NADU | 600017 | Make: Tenmars
Model: TENMARS & TENMARS 87 | - | Disqualified | |
| 5 | Disqualified Make: Keysight Technologies
Model: U1232A E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Keysight Technologies
Model: U1232A | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
19 Jun 2018, 2:00 pmClosed
digital multimeter Experience with Gov. Required 3 Year (s) Digital Multimeter ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 3.5 3.5
4.5
6.5 Measurement Type True RMS Average
True RMS Counts 6000.0 4000
6000
50000
2000 00 MEASUREMENTS DC Voltage Range 600.0 600
1000 DC Voltage Accuracy 0.5 0.005
0.05
0.1
0.5
1 DC Voltage resolution 100.0 0.001
0.01
1
10
10 0 AC Voltage Range 600.0 600
1000 AC Voltage Accuracy 1.0 0.08
1 AC Voltage resolution 0.1 0.001
10 0 DC Current Range 10.0 3
10 DC Current Accuracy 1.0 0.005
1.5 DC Current resolution 10.0 0.001
10 0 AC Current Range 10.0 3
10 AC Current Accuracy 1.5 0.5
1.5 1/5 AC Current resolution 0.01 0.001
10 0 Resistance Range 40.0 40
50
60
100
500 Resistance Accuracy 1.0 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.1 0.001
10 0 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 5 1.5
3.5
5
NA Capacitance resolution ( nF ) 1 0.001
10 0
NA Frequency Range ( KHz ) 100 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.01 0.001
NA Temperature Range ( Degree C ) NA -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) NA 1.5
NA Temperature resolution ( Degree C ) NA 0.001
NA OTHER FEATURES Continuity test and Diode test Available - Data logging Available - If Data Logging Feature is Available
Internal Memory NA - Computer Interface along with software Not Available - Dimensions ( mm X mm X mm ) 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") - Weight 550.0 - Other Features Large white LED backlight to work in poorly lit areas Resistance and continuity Min/Max/Average to record signal fluctuations - SAFETY Safety Rating Category III 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 2/5 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification UL - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated
then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable
then chemistry of the battery NA - if Non-rechargeable
then size of the battery cell 9-V rectangular battery - number of non- rechargeable the battery/cell 1 - Voltage of rechargeable Battery 0.0 - capacity of rechargeable battery(milli Ampere Hour) 0.0 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment Holster Installed 9 V battery 4 mm silicone test lead set User manual - WARRANTY Warranty 3.0 1
5 OPERATING CONDITION Minimum Operating Temperature -10.0 - Maximum Operating Condition 50.0 - Operating Humidity (RH) 90.0 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 true - 3/5 latest conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test 1001-08.01.2018 - Name and address of the Lab for the specification test Fluke - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 CONTRACTS AND MATERIAL MANAGE DIRECTOR 500069
RESEARCH CENTRE IMARAT
P O VIGNYANA KANCHA 4 15 EMD Required No ePBG Required No
201835
GEM/2018/B/28738
digital multimeter
15 days
Telangana; Ranga Reddy
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Experience with Gov. Required 3 Year (s) Digital Multimeter ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 3.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 6000.0 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 2000 00 MEASUREMENTS DC Voltage Range 600.0 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.5 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 100.0 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 10 0 AC Voltage Range 600.0 600 | - | - | - |
| 1000 AC Voltage Accuracy 1.0 0.08 | - | - | - |
| 1 AC Voltage resolution 0.1 0.001 | - | - | - |
| 10 0 DC Current Range 10.0 3 | - | - | - |
| 10 DC Current Accuracy 1.0 0.005 | - | - | - |
| 1.5 DC Current resolution 10.0 0.001 | - | - | - |
| 10 0 AC Current Range 10.0 3 | - | - | - |
| 10 AC Current Accuracy 1.5 0.5 | - | - | - |
| 1.5 1/5 AC Current resolution 0.01 0.001 | - | - | - |
| 10 0 Resistance Range 40.0 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1.0 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.1 0.001 | - | - | - |
| 10 0 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 1 0.001 | - | - | - |
| 10 0 | - | - | - |
| NA Frequency Range ( KHz ) 100 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.01 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) NA -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) NA 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) NA 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available - Data logging Available - If Data Logging Feature is Available | - | - | - |
| Internal Memory NA - Computer Interface along with software Not Available - Dimensions ( mm X mm X mm ) 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") - Weight 550.0 - Other Features Large white LED backlight to work in poorly lit areas Resistance and continuity Min/Max/Average to record signal fluctuations - SAFETY Safety Rating Category III 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 2/5 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated | - | - | - |
| then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable | - | - | - |
| then chemistry of the battery NA - if Non-rechargeable | - | - | - |
| then size of the battery cell 9-V rectangular battery - number of non- rechargeable the battery/cell 1 - Voltage of rechargeable Battery 0.0 - capacity of rechargeable battery(milli Ampere Hour) 0.0 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment Holster Installed 9 V battery 4 mm silicone test lead set User manual - WARRANTY Warranty 3.0 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature -10.0 - Maximum Operating Condition 50.0 - Operating Humidity (RH) 90.0 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 true - 3/5 latest conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test 1001-08.01.2018 - Name and address of the Lab for the specification test Fluke - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 CONTRACTS AND MATERIAL MANAGE DIRECTOR 500069 | - | - | - |
| RESEARCH CENTRE IMARAT | - | - | - |
| P O VIGNYANA KANCHA 4 15 EMD Required No ePBG Required No | - | - | - |
Exempted
19 Jun 2018
13 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_201835.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .