| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹23.5 L+₹925 (0.04%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Mar 2020, 6:00 pmClosed
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2020_MES_325024_1
GE (AF) NAL/T-51/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) Nal
As described in Bill of quantities
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹60,000
Yes
GE (AF) Nal, Bikaner
5 Jun 2020
14 Feb 2020
23 Mar 2020
14 Feb 2020
21 Mar 2020
28 Feb 2020
17 Feb 2020 - 20 Feb 2020
22 Feb 2020
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed
Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed.
Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
Supply and laying unreinforced precast concrete cable cover class HVP, type - 1 with peak of size 300 mm x 180 mm x 40 mm laid in trenches over under ground cable complete all as spcified and directed.
Taking out defective cable XLPE/PVC sheathed 11000 volt grade heavy duty armoured with aluminium conductor 3 core 95 sqmm from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
All as per description of serial item No. 6.00 here in before but 1100 volts size of cable 3.5 core 240 Sqmm
All as per description of serial item No. 6.00 here in before but 1100 volts size of cable 3.5 core 35 Sqmm
Supplying, laying, jointing and testing of under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, 11000 volt (E) grade heavy duty with stranded aluminium conductor 3 core 95 Sqmm conforming to IS 7098 ( Part -2) 2011, laid in trenches / duct / pipe including all electrical connections with required lugs and nuts, bolts complete all as specified and directed. Note:- Note : (i) Excavation & earth work, sand cushioning, cable protection and cable joints shall be measured and paid for separately.
Supplying, laying, jointing and testing of under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, 1100 volt grade heavy duty with stranded aluminium conductor 3.5 core 240 Sqmm conforming to IS 7098 ( Part -2) 2011, laid in trenches / duct / pipe including all electrical connections with required lugs and nuts, bolts complete all as specified and directed. Note:- Note : (i) Excavation & earth work, sand cushioning, cable protection and cable joints shall be measured and paid for separately.
All as per description of serial item No. 10.00 here in before but size of cable 3.5 core 35 Sqmm.
Supplying and fixing as in repairs 1100 volts grade heavy duty cable 10sqmm, twin core, flat or circular, PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. Note:- Excavation & earthwork, if any, shall be measured and paid for separately.
S&F as in repairs rigid mild steel conduit 20mm dia including conduit accessories for passing of service cable fixed with and including saddles etc. complete all as specified and directed.
Supply, laying and testing as in repairs PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable of size 1.5 sqmm 2 core, 1100 Volt, conforming to IS 694 complete all as specified and directed.
Supply & fixing as in repair cable jointing kit for 11 KV (E) grade for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable upto 50 Sqmm to 95sqmm 3 core XLPE cable armoured aluminium conductor complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of the existing joint.
Supply & fixing as in repair cable jointing kit for 11 KV (E) grade for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable upto 50 Sqmm to 95sqmm 3 core XLPE cable armoured aluminium conductor complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of the existing joint.
Dismantling and taking out the old stay assembly complete incl demolition of plain cement complete all as specified and directed. Note : (i) Unit rate of this item includes the loose / disconnect the all accessories which are connected to stay assembly includng necessary excavation as directed. (ii) Existing stay assembly are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account.
Material and Labour Stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 16 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 concrete all as specified and directed. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire.
Material and labour two coats of silver/aluminium paint on steel tubular pole 9.0 metre long including on MS work like channel cross arms, nut, bolts & washer, street light bracket and clamps etc. for the portion above 1.50 metre from top of PCC coping and two coats of synthetic enamel paint in alternative red and white strips of 30 cm each upto 1.50metre from top of PCC coping and writing pole No. with black paint on a yellow circle 150mm dia including scrapping the existing paint and preparation of surfaces complete all as specified and directed.
All as per description of serial item No. 19.00 here in before but 11.0 metre long with swan neck
Material and labour two coats of cement base paint on LT RCC pole 9.0 meter long for the portion above 1.50 metre from top of PCC coping and two coats of synthetic enamel paint in alternative black and white strips of 30 cm each upto 1.50metre from top of PCC coping and on MS work like channel cross arms, nut, bolts & washer, street light bracket and clamps etc. and writing pole No. with black paint on a yellow circle 150mm dia including scrapping the existing paint and preparation of surfaces complete all as specified and directed.
Material and labour writing MES / SM / machine No. on MES equipment such as voltage stabilizer / DG Set / HT Panels etc. with one coat of synthetic enamel paint (heat resistant) in black colour on a yellow circle 150mm dia including scrapping the existing paint and preparation of surfaces complete all as specified and directed.
Material and Labour removing old stone aggregate any size from Sub Station Yard and laying new stone aggregate 20mm size including making good the existing surface complete all as spefied and directed. Note : Before laying new stone, existing area shall be neatly cleaned and existing bushes, grass etc shall be removed and thrown away as directed.The quoted rate shall include the cost thereof
Taking out of out door type transformer of any capacity from inside the sub station/ 4 pole structure after removing / disconnecting of HT/LT connection and reinstalling the same at out side permises on foundation including making all connection of HT / LT cable, cable joints, earth strip etc and testing complete all as spcified and directed. Note : (i) HT cable, LT cable, out door termination (end Joint), Straight through joint and GI earth strip shall be measured and paid for separatly. (ii) Contractor shall provide all the T&P including transportation for shifting of transformer and nothing extra shall be paid on account of loss of manpower during shift. Tenderer is hereby advised to keep in mind this factor before quoting his rates.
Dismantling of 11 metre 4 pole structure consisting of 4 No. RCC poles, anti-climbing device, PCC foundation & cross arms (Bracings) etc carefully after disconnecting HT cable connection carefully, cutting cable end joint for new connection in VCB / RMU panels and making good the disturbed surfaces complete all as specified and directed. Note: (i) Earth work required for taking down cable and re-laying including sand, bricks shall be measured separatly. (ii) Rate quoted shall deemed to be included for removing the poles & other materials obtained from dismantling to outside MoD land.
All as per description of serial item No. 25.00 here in before but two pole structure consisting of 02 No. RCC poles anti-climbing device, PCC foundation & cross arms (Bracings) etc
M&L bus bar chamber cubical inclined top out door type made out of 3 mm thick MS sheet of size 450 x 300 x 200 mm including aluminum busbar of capacity 200 Amps for each phase and 100 amps for neutral for incoming and out going. The panel shall be suitable for 415 volts, 50 Hz, 3 phase 4 wire system and all as specified and directed. Note :- Earth work, PCC work and MS work for legs / holding of chamber shall be measured and paid separately.
S&F as in repairs Off Load change over switch 32 Amps 4 pole 415 Volts complete all as specified and directed. Make : Havells / L&T / Siemens / Crompton Greaves
Supply and fixing as in repairs conventional street light 150/250 watt SV/MV with LED street light 72 watt 230 volt pressure die cast aluminum housing heat resistant toughened glass with frame IP 66 better optics from uniform distribution having surge protection 5 KV , sealed driver make Crompton Greaves Cat No LSTP-72-CDLM or equivalent in Philips / HPL / Havells.
S&F as in repairs LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including the following fixtures amd fitments mentioned against srl 30.01 & 30.02 below:-.:- Location:- Officers' Md Accn
Outgoing:- Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. (i) MCCB, 4 pole 160 A, 25 KA -02 No (ii) MCCB, 4 pole 100 A, 25 KA -04 No (iii) MCCB, 4 pole 63 A, 16 KA -03 Nos (iv) Astronomical time switch 110/240 volts -01 No. Make : Havells / L&T / Crompton (v) Power contactor 63 Amp 4 pole 415 V 50 Hz model MCX 12 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T / Havells / Siemens / Crompton Make of MCCB: Legrand / Seimens / Schneider / ABB Note:- (i) A clear space of 200mm shall be kept from floor level for switchgear compartment. (ii) Air ventilation breathers with exhaust fan plastic body 100mm sweep shall be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. (iii) Each compartment shall be numbered/lettered as per the approved approved by GE. . (iv) Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the bulk order
S&F as in repairs LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including the following fixtures amd fitments mentioned against srl 31.01 & 31.02 below:-.:-
Outgoing:- Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. (i) MCCB, 4 pole 125 A, 25 KA -02 No (ii) MCCB, 4 pole 100 A, 25 KA -04 No (iii) MCCB, 4 pole 63 A, 25 KA -02 Nos Make of MCCB: Legrand / Seimens / Schneider / ABB Note:- (i) A clear space of 200mm shall be kept from floor level for switchgear compartment. (ii) Air ventilation breathers with exhaust fan plastic body 100mm sweep shall be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. (iii) Each compartment shall be numbered/lettered as per the approved approved by GE. . (iv) Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the bulk order
S&F as in repairs Astronomical timer switch 110/240 volts complete all as specified and directed. Make : Havells Cat No DHTKW01016 or equivalent in make L&T / Crompton / Bajaj
Supplying, fixing as in repairs Power contactor 63 Amp 4 pole 415 V, 50 Hz model MCX 12 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no CS97014 or equivalent in Make Havells
Material and labour as in repairs earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. (7.5 metre long earth strip upto test point included in unit rate of this item.) Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ), 3rd layer with tibba sand up to ground level. Earthing shall also include concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete to obtain less than 2 Ohm earth resistance value, complete all as specified. NOTE : (i) Cost of this items includes the scope of earth work, charcoal, salt, PCC, RCC pit cover of required size. (ii) Tibba sand shall be arranged by the contractor at his own and the cost thereof shall be deemed included in unit quoted rate of this item. (ii) Electrical Plate No. 3 refrred in the item above is mainly for earth chamber.
Supply and fix as in repairs GI strip 32mm x 6mm burried in ground / laid in floor / fixed to wall on saddles / on porcelain insulators etc complete all as specified and directed. Note : Excavation and earthwork shall be measured and paid for separately.
Supply and fixing as in repairs MCCB, 100A, rupturing capacity 16 KA , 415 volts, 4 pole in existing DB of existing make and making connections complete all as specified & directed.
M&L trimming of tree branches on both sides of LT overhead line complete all as specified and directed. NOTE : (i) Cutting branches shall be dumped outside the air force premises. (ii) Contractor shall provide the ladder of required size including T&P to his worker and nothing extra shall be paid on this account. (iii) Before commencement of trimming work, elctric shutt down shall be got managed by the contractor and sufficient man power shall be deployed on the particular time so that the task given by the Engineer-in-Charge shall be completetd with the time allowed.
Supplying and laying as in repairs 50mm bore GI tubing light grade incl all accessories for pssing of cables for mechanical proctection, laid under Plinth / Floors / Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed. Note:-MS works including painting will be measured under seperate item in Schedule
M&L as in repairs silica gel with breather assembly suitable for transformer 100 KVA to 630 KVA complete all as specified and directed.
S&F as in repairs danger notice plate 20x15cm size made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour for LT, and fixed with M.S. clamps, bolts and nuts of approved size, all as specified and directed.
All as per description of serial item No. 40.00 here in before but size 25 x 20 cm for HT
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation for poles / filling / mass concrete complete all as specified and as directed
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping to poles including necessary form work complete all as specified and as directed
Material and labour Spray painting to outer surfaces of transformer upto 100 KVA transformer 11KV / 433V outdoor type including radiators, cooling ducts, vent pipes, condensers etc. with two coats of synthetic enamel paint (heat resistant) including scraping, removing existing old paint and writing MES / SM No. with size of letter 5cm x 5cm complete all as specified and directed.
All as per description of serial item No. 44.00 here in before but capacity of transformer 160 KVA to 630 KVA
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified.
M&L hardcore of broken boulders of gauge n exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base / sub floors surface finished even and rough to receive floor topping complete all as specified and directed.
M&L Chequered cement concrete coloured tiles 25cm x 25cm x 25mm thick set, jointed in neat cement slurry and pointed in grey cement with pigments laid over and including 15mm thick cement screed bedding in cement mortar 1:4 complete all as specifed and directed.
M&L rendering 10mm thick in cement moratr 1:4, on brick or concrete surfaces of walls, surfaces finished even and smooth without using extra cement complete all as specified and directed.
Blank
S&F as in repairs 4mm dia galvanised steel wire mesh, size of mesh 150mmx100mm , made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed.
M&L as in repairs mild steel work in framed work such as grills, gates, framed guard bars, gratings, ladders, cable tray, fencing etc, with end of bars soldered / welded and or riveted or forged into spikes and similar work confirming to Fe 290 E -165 incl two coats of mettalic paint over a coat of mettalic primer complete all as specified and directed.
Repairing of rolling shutter, push type, area n.exc 6sqm each for smooth functioning by re-posting of laths, riveting to old defective rivets, tightning nuts and bolts, re-stretching of spring, greasing to movable parts and at guide channel including taking out and re-fixing rolling shutter in position complete all as specified and directed. Note : (i) T&P required for taking down the door for repair and re-fixing the same shall be arranged by the contractor at his own and the unit rate quoted shall include the cost thereof. No clam whatsoever on this account shall be entertained. (ii) Replacement of defective steel members, items shall be measured and paid as 'Supply only' against respective item of this schedule.
All as per description of item No 54.00 here in before but size of rolling shutter exc 6 sqm but n.exc 15 Sqm
S & F mild steel plain sheets covering to door shutter and top cover of rolling shutter cover cut to size , edges beaded as directed, holes punched all as specified and directed.
S&F as in repairs rolling shutter push pull or manual type with 1.00mm thick lath without ball bearing as specified including top cover anchoring rod, hasp and staple and one shop coat of primer and erected in position as indicated all as specified and directed
Supply only MS spring shuitable for rolling shutter area not exceeding 6 Sqm
Supply only MS spring shuitable for rolling shutter area exceeding 6 Sqm but not exceeding 15 sqm
Supply only MS ball bearing suitable for rolling shutter area not exceeding 15 Sqm
Supply only gear assembly suitable for rolling shutters fixed in position all as specified.
Supply only mild steel section of any size or any section including necessary cutting & drilling holes as required.
Supply only mild steel solid roller of any dia or section complete all as specified .
M & L preparation of old steel surfaces of rolling shutter and applying two coats of synthetic enameled paint by spray machine complete all as specified and directed
Taking down door / window frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) complete all as specified and directed.
M&L Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc including powder coating of any colour (Thickness or powder coating not less than 50 micron). complete all as specified.
M&L Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 in each pane of thickness 4.0 mm including all fixing arrangement all as specified and directed.
RAJENDER ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .