Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest |
Tender Value
₹14.3 L
EMD Value
₹28,700
Closing Date
8 Aug 2020, 6:00 pmClosed
GE PARTAPUR
GE PARTAPUR
PROVN OF 01 X ROOM AND ALLIED INFRA FOR INSTLN AND OPERATION OF X RAY MACHINE IN 403 FD HOSP AT HUNDER UNDER GE PARTAPUR
2020_MES_360598_1
GE/P-33/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE PARTAPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PARTAPUR
₹28,700
Yes
6 Nov 2020
13 Jul 2020
10 Aug 2020
26 Jul 2020
8 Aug 2020
27 Jul 2020
Amount
Surface excation not exc 30 cm depth and avereging 15 cm depth and getting out in hard/dense soil.
Exacavation in trenches n exc. 1.5 m wide and n exc. 1.5 m depth for foundation ,etc n exc 10 sqm on plan in hard and dense soil and getting out
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard and dense soil.
Removing excavated material soil exc 250 m but n exc 500m and deppsiting where directed at a level n.exc 1.5 m above the starting point
M&L for PCC in foundation Type D2 1:4:8 (40 mm graded aggregate) complete all as specified and driected.
M&L for Use & waste of formwork, rough finished flat concrete fdn, footings , bases of coloumn , raft and raft beams , sides and soffits (if any) of foundations and plinth beams and similar works, verical or to batter complete all as specified and directed.
M&L for RCC M-30 (20mm agg) in Foundations, including rafts, footings, foundation beams; plinth beams;bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L for Formwork to sides of pillars, posts, struts,piers, columns and stanchions in rough finished of concrete square, rectangular or polygonal
M&L for RCC M-30 (20mm agg) in columns, pillars, piers, posts and struts
M&L for Formwork to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished in rough finished concrete complete all as specified
M&L for RCC M-30 (20mm agg) in beams, cantilevers, bressummers, lintels over 1.5m span
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping)
M&L for M-30 (20mm agg) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and th like
M&L cement concrete type B-0 1:2:4 (12.5 mm graded aggregate) as in roof kerbs or mud stops , rounded or chamfered , as in roof padding complete all as specified and as directed.
S&F TMT bars 10mm dia and above in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
Description all as per serial item no 15 above but for 6mm to 8mm dia.
S&F TMT bars 6 to 8mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
Precast cement concrete block masonry with solid blocks exc 10 cm in width and set in cm 1:6, type C1 1:3:6 (20 mm graded aggregate)
M & L for Rendering 10 mm thick on brick work or concrete surfaces used Cement plaster 1:6
M&L rendering 5 mm thick in CM 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for Rendering 15 mm thick on brick work or concrete surfaces used Cement plaster 1:4 (External surfaces)
Supply only water proofing compound.
M&L hardcore or gauge of brokenstone or boulders n.exc 63mm, deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface.
M&L moorum filling in floors or paving laid in layers n.exc. 15cm thick spread levelled and rammed including watering complete all as specified and directed.
M&L P.C.C (1:4:8) type D-2, 75mm thick in sub base for floor.
M&L light shed vetrified ceramic tiles 10mm thick (square/rectangular polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement to match incl over 15 mm thick CM 1:6 screed bad for laying floor all as specified and directed.
M&L non skid ceramic colour tiles 7mm to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bedding in CM 1:6
M&L glazed ceramic white tiles 300x200x 7mm thick, on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match incl. 10mm thick plaster backing in CM 1:4
M&L for Cement concrete 75mm thick 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection finished even and rough complete all as specified
M&L for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces on walls and applying two coat of cement base paint all as specified and directed
M&L for preparing new surfaces of wall and applying two coats of OBD (washable) over a coat of chalk whitening all as specified.
S & F 2nd class hardwood Plain, solid, straight chowkhat and frames, wrought, framed rebated on solid, rounded or chamfered,put together with glue pinned at joints, all as specified and directed.
S & F 35mm thick, 2nd class HW, plain framed, panelled shutter (one panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, both faces is covered with decorative face veneer with liping/ frame to match.
S&F for Anodised aluminium frame for doors, windowS, ventilators with one or more rebates including joining cleat for fixing of glass, particle board,aluminium frame etc complete all as specified and directed
S&F Anodised aluminium window and ventilator shtters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, anodised aluminium snap beading, screws etc. complete all as specified .
S&F 4.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panel
M&L for preparation of new wooden surface and applying two coat of synthetic enamel paint over a coat of pink primer.
S & F butt hinges 100 mm, medium weight, cold rolled mild steel complete all as specified
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified
S & F Aluminium alloy, anodised, sliding door bolt (250mm) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 150mm Extruded aluminium alloy handles, fabricated type. Anodised
M & L for Mild steel hold fast and similar small articals conforming to Fe 290 Gde E 165 complete all as specified and as directed by the Engineer-in-Charge
S&F vitreous china wash basin, white, flat back, size 550x400 mm including brackets, cutting pinnning in ends of brackets or erecting stand but exclusive of fixing, complete assembled all as specified and directed.
S&F 32mm bore waste coupling of PTMT (Half or full threaded) (min weight 32mm-45gms/40mm-60gms) as specified and directed
S&F grating to 100mm dia of PTMT (min weight 25 gm) all as specified and directed
S&F 15mm bore pillar taps fancy type, cast copper alloy , with capstan heads, chromium plates, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed all as specified.
S&F chromium plated fancy type 15 mm bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F, viterous china wash down water closet pan ( Pedstal pattern) including seat cover and making good to floor, complete all as specified and directed by Engr-in-charge.
S&F, Vitreous china bowl urinal flat back, size of 465 X 355 X 265 mm white, with grating and union for discharge pipe ( excluding flushing cistern., flush pipe and waste pipe) fixed in repair , complete all as specified and directed by Engr-in-charge.
S&F, PVC connection of 15 mm sixe with PTMT nuts of length 450 mm , complete all as specified and directed by Engr-in-charge.
S&F 15mm Stop valves, fency type, chromium plated, long shank screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S & F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets capacity 10 ltrs all as specified.
S&F 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S&F PVC 'P' & 'S' trap 110/110mm bore all as specified
S & F PVC (SWR) pipes 75 mm bore, single socketed, in any length, with rubber ring joints, laid in trenches or in floors as specified.
S & F PVC (SWR) pipes 110 mm bore, single socketed, in any length, with rubber ring joints, laid in trenches or in floors
S & F PVC (SWR) pipes 110 mm bore, single socketed, in any length, with rubber ring joints, laid in walls
S & F 75 mm bore PVC (SWR) bends any radius
S & F 110 mm bore PVC (SWR) junction single, (Single T) equal or Unequal
S&F 25mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
S&F 20mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 litres hoisted and fixed in position all as specified and directed.
M & L pre cast cement concrete block masonry solid blocks type C1 1:3:6 ( 20 mm graded aggregate) exceeding 10 cm width , set in CM 1:4 as tanks staging all as specified and directed.
S&F PP-R gate valves (brass insert) 25 mm outer dia of pipes all as specified and directed.
Soakage wells excavation of size 2.40 m x 3.0 m effective depth, in hard/dense soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size(CESZ/TD-1078/2011 sh No 1/1 dt 01 Dec 2011)
Removing excavated material to a distance not exc 50m and depositing where directed at level not exc 1.5m above the starting point all as specified and as directed.
Plain cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes incl packing under and hauching against the side of pipes after they are laid and tested for 150mm bore SGSW pipes complete Note-(i) Thickness of concrete bed shall be 100mm. (ii) The payment of concrete hauching for the portion over offset of the manhole shall be paid under Item below.
S&F 150mm dia SGSW pipe laid in trenches and jointed as specified
S&F 100mm dia cast iron soil, waste and vent pipes in any length as specified.
M&L flush door shutter of size 2000mm x 2100mm x 2mm thick lead lined with frame fixed with all necessary fittings and screws all as complete.
M&L Sand cushioning to the under ground electric cable 8 cm before laying the cable and 15 cm after laying the cable complete all as specified in clause No. 19.75 of SSR Part-I 2009, complete all as specified and as directed by Engr-in-Charge.
Supply and laying un-reinforced precast concrete cable covers for cable protection of class LV type-1 flat of size 250 x150 x 40 mm, Complete all as specified and directed by Engineer-in-Charge.
M&L Point wiring with 1.5sqmm (nominal area) copper conductor FRLS cable (multi-stranded) PVC insulated and unsheathed electric cable 1100 volts cable and including PVC casing and caping suitable size (as per conductor run) with all fittings and accessories and including PVC insulated, un sheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core green colour) cable as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated sheet (Make 0 Hylum) for one light point /fan point / bell point etc controlled by one, one way switch. Complete all as specified and directed by Engineer-in-Charge.
Description all as per item no 76 here in before but one 3 pin socket out let 5 Amps on independent board.
M&L point wiring for power point with 4 sqmm (nominal area) copper conductor FRLS cable ( multi-stranded) PVC insulated and unsheathed cable conductor 1100 Volts drawn through rigid PVC casing capping of suitable size (ISI Marked) (Make - Hylum) including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes with 3.0mm thick plastic laminated sheet cover (Make - Hylum) for 6 pin/5pin socket outlet. 15 Amp on independent board with 4 sqmm (nominal area) FRLS copper conductor cable (multi-stranded) PVC insulated and unsheathed (green Colour) with colour code earth wire to common eart dolly. Complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way 5 Amps. Complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination 5 pin, 5 Amps 2 in 1 flush type (multipurpose) suitable for 2 pin / 3 pin pulg. Complete all as specified and directed by Engineer-in-Chage.
S&F switch socket combination 5 pin, 15 Amps 2 in 1 flush type (multipurpose) suitable for 2 pin / 3 pin pulg. Complete all as specified and directed by Engineer-in-Chage.
S&F ceiling rose surface bakelite 65x50mm two to three therminal conforming to ISI. Complete all as specified ans as directed by Engineer-in-Charge.
S & F surface and wall mounted LED batten lumiline with polycarbonate housing and integrated electronic driver tube light fitting 20W, 4 ft long, 220 Volts , and connecting to ceiling rose with three core twisted flexible copper cable of suitable size complete all as specified and directed by Engr-in-Charge. Make: Havells cat part No LUMILINEBS20WLED865SPCWH or its equivalent in philips, bajaj, syska, surya
S&F sheet metal enclosures (factory made) double door for distribution oard (when MCSs are to be used) single pole and neutral 240 volts 8 ways with 200 Amps rated busbar conforming to ISI. Complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring with single core copper conductor cable FR flexible multistrand PVC insulated (unsheathed) of size 2x16 Sqmm and one Nos 1x10sqmm with single core copper conductor cable FR multistrand PVC insulated (unsheathed) as in continuous earth wire drawn into existing concealed conduit complete complete all as specified and dirted by the Engr-in-Charge.
S & F MCB single pole 240 volts, 05 to 40 Amps, 10 KA complete all as specified
S & F MCB triple pole neutral 415 volts, 63 Amp complete all as specified
S & F MCCBs 415V, 16KA, 4 Poles, 63 Amp complete all as specified
Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 3.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized earth lead of size 04 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
Earthing of machinery / equipment installed at Power house/substation, using 20 x 3 mm copper strip as earthing lead and copper plate of size 600x600x3.15mm, as earth electrode.Earth plate electrode buried directly in ground ( earth plate not less than 3.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized earth lead of size 04 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
Supply, laying , testing & commissioning cable 1100 volts grade XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor ISI marked incl cable glands, lugs etc to suit the cable size to be laid in trenches, fixed along pole, LT panel through GI pipe laid under floors fixed concealed in wall encased in GI pipe etc complete of size 35 Sqmm 3.5 Core, complete all as specified and as directed by Engr-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .