Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 01₹21.2 LAccepted-AOC | 01 | Accepted-AOC Justified quoted rate |
Tender Value
Refer Docs
Closing Date
3 Jul 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Civil BSNL CD Kolkata
148 CR Avenue TE Burrabazar Telephone Exchange Kolkata 700007
Infrastructure work of Kalaikunda IAF site under NFS Project Package II) .
2021_BSNL_80518_1
14/WB/CD-KOL/BSNL/NIT/21-22
Open Tender
Civil Works
Item Rate
120 days
Kalaikunda IAF site
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
BSNL
Exempted
7 Nov 2022
26 Jun 2021
6 Jul 2021
26 Jun 2021
3 Jul 2021
26 Jun 2021
60 days
Amount
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the 'W' profile (0.55mm thick ) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm, placed @ 610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @200mm C/C., all complete as per the drawing & directions of engineer-in-charge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish.
Plain Gypsum plaster board conforming to IS: 2095( Part - I) : 2011 (Board with BIS certification marks) (i)12.5 mm thick.
Providing and fixing of metal fire rated doors as per IS 3614 part-2:1992 for stability and integrity. Pressed Galvanized steel confirming to IS 277 specification. Door tested and Approved in CBRI, Roorkee or any other approved statuatory body for maximum rating of 2 hrs and its test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen. Door frame shall be single rebate frame profile of size 140 mm x 65 mm with bending radius of 1.4 mm shall be constructed out of 1.20mm thick galvanized steel sheet.There should be bottom membrane in the frame for proper alignement. Provision should be kept for grouting with cement and sand slurry necessary for fire doors on the clear masonry opening. Door leaf should be 50 mm thick fully flush double skin door steel with seamless welding joint all around. Door leaf shall be fabricated from 1.0 mm thick galvanised steel sheet conforming to IS 277 spcifications, single or double leaf as the case may be. The infill material is proprietary are retardant heat insulating material suitable for 2 hrs fire rating as per IS 3614 part-2:1992 for statibility and integrity and construction of the door should be rigid reinforcement pads for receiving appropriate hardware. All doors shall be factory prepared with 3 mm thick support plate pre-punched cutouts and reinforcement for receiving appropriate hardware. All doors shall be provision for 4 Nos Anchor bolt fasteners on each vertical jamb to fix to wall / RCC surface, all cut outs including hinge plates, strike plates have mortar guard cover to prevent cement, dust ingress into cutouts. Shutters have no visible screws, fastners or rivets on either face. Shurrers are pre drilled hinge support plates with hinge guard covers, concealed lock box with lock fixing brackets and pre-tapped holes. Locking mechanism shall have with 3 keys each door and shall have door closer on each leaf. The doors shall be provided with vision glass of 6 mm thich 2 hours fire rated. Painting of doors shall consist of galvanized steel treated progressively with etch primer, zinc chromate primer and top coat of PU paint. All works shall be done as per manufacturer specification and as per direction of the Engineer-in-charge. (Rate includes all operation and hardwares mentioned above, nothing shall be paid for extra).
Single leaf shutter
Double leaf shutter.
Extra for providing arrangement for provision of Access Control System in fire rated double door shutter (Payment to be made on the area of shutter including frame work).
Providing and fixing for fitment of card based access control system (SITC) of approved quality and make in door shutters to enable proper locking arrangement by access card from outside and push button to open from inside.(It is to be supplied by the agency to the door shutter manufacturing agency for making arrangement of the system before starting manufacture of shutters and frames).
Supplying RFID card for entry / exit in access door system as per requirement of the authority with complete activation and satisfaction of the Engineer-in-charge.
Providing and installing raised fire rated false floor consisting of pedestals, Stringers and floor penals etc. Raised false shall have integrated stringer arrangement for enhanced load bearing capability with floor panels shall be manufactured from steel with lightweight cementitious core in size 600 x 600 x 35 mm. The floor panel top shall be finished with high abrasion, anti-static High Pressure Laminate with PVC beading on all sides to provide protection of edges and cut out, if any. The raised floor height shall be between 155 mm to 750 mm. The floor must support point load of 3.6 KN/over 25 Sqmm and distributed load of 12 KN / Sqm, ultimate point load 1125 kg (2500 lbf). The bottom of the panel shall be embosed in 64 hemispherical cones to give strength and flexural rigidity. The entire panel shall be finished with electro deposition of cathodic epoxy paint on the exposed surface and shall be Zinc Whisker free. Pedestal shall be 22mm dia GI pipes for 600mm long 25mm dia GI pipe for 750mm long, having 100x100x2mm thick GI base plate permantly fixed to sub floor by application of epoxy based adhesive and at least 4 nos hold fasteners in base plates and pedestal head assembly should be of 75x75x3.5mm. Stringer system shall be hot dipped galvanised steel rectangular shaped snap lock channel of size 570x21x32x0.80mm thick with notches for locking stringers to pedestals. The work shall be executed as per manufacturer specification and as per direction of the Engineer - in - charge. The payment shall be inclusive of all operation above and nothing will be paid seperately.
Extra for providing and fixing Air Flow grills manufactured from Mild steel with a perforated top having an overall size of 600 x 600 mm. The panels consist of specially designed side channel section which houses a pre punched top perforated sheet with optional volume control damper. The panel can be compatible with the adjacent raised access floor system. The top performance finishes is powder coated . The floor must support point load of 3.6 KN/over 25 Sqmm and distributed load of 12 KN / Sqm. (Diffrence in cost of Air flow perforated grill in respect to false floor tiles to be taken in consideration for payment irrespective of plus or minus for each tiles)
Providing and fixing PVC Grommets 125mm dia to run cables through floor or through wall. Rate including the cost of making hole etc.
Providing double cup suction panel lifter to lift the panel quickly, easily and safely without damaging any of the adjoining access floor panels.
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/cum , 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:
Two or more coats on new work.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1cement: 4 coarse sand).
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Of area beyond 3 sq. metres
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead:
Of area 3 sq. metres and below
Dismantling tile work in floors and walls laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles above 25 mm and up to 40 mm
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Taking out carefully existing PVC flooring from floor surface including mending good of the damages of the floor surface and removal of unserviceable materials to municipal dumping ground within 5Km lead all complete as per direction of the Engineer-in Charge.
Removing wall panelling from existing wall surface including mending good of the damages complete as per directions of engineer in charge.
Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of gypsteel, precoated on exposed portion only, consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
15 mm thick glass wool tile of size 595x595 mm, having an NRC ( Noise Reduction Coefficient) of 0.70, tiles shall withstand a permament ambient RH upto 95%
Credit value of Dismantled / unserviceable material:
Wall paneling with supports
False ceiling with grid
Door shutter and frame 1750x2050 mm
Door shutter and frame 1050x2050 mm
Un-usable PVC Flooring
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .