| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹6.1 L+₹63,030 (11.5%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹6.5 L+₹1.1 L (19.3%)Rejected-AOC NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹6.8 L
EMD Value
₹13,600
Closing Date
31 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Navy Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
MAINTENANCE OF EM INSTALLATIONS AND FEEDER PILLER BOXES IN CHENNAI UNDER AGE(I) NAVY CHENNAI
2021_MES_492258_1
AGE(I)/NAVY/CHN/8261 of 2021 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) Navy Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹13,600
Yes
31 Mar 2022
3 Dec 2021
1 Jan 2022
3 Dec 2021
31 Dec 2021
17 Dec 2021
4 Dec 2021 - 10 Dec 2021
60 days
Amount
M&L for PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed.
M&L for PCC 1:3:6, type C-1, using 20 mm graded stone aggregate, as in foundation including necessary form work and finishing the exposed concrete surfaces even and fair completea all as specified and as directed
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 70 sqmm 3 core, 11000 volts grade, complete all as specified and directed. (Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid seperately)
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 95 sqmm 3 core, 11000 volts grade, complete all as specified and directed. (Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid seperately)
Supply and replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed.
S&F (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed
S&F (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed
S&F (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified and directed
Supply and spread crushed stone aggregate of not exceeding 40mm size 150mm thick layer over well prepared sand bed layer all as specified and as directed.
Supply and spread M-sand not exceeding 30 cm thick all as specified and as directed.
Taking out vacuum circuit breaker by disconnecting carefully electrical connection from incoming and out going from panel carefully.Overhauling the spring charging mechanism,checking the vacuum gap,greasing and adjusting of moving parts and adjusting as required, Cleaning all parts by CTC solution / emry paper as required and greasing the metallic and mechanical serviceable parts.
Removing,cleaning,servicing, calibration, testing and commissioning of microprocessor based earth fault and over current fault relay
Removing,cleaning,servicing, calibration, testing and commissioning of electro megnatic earth fault and over current fault relay
Replacement of Fuse carrier including HRC fuse upto 10 amps suitable for operating voltage 110/220 Volt for HT/LT Panel
S&F in replacement push button switch suitable for operating voltage 110/220 Volt for HT/LT Panel
S&F in replacement indicator lamp LED suitable for operating voltage 110/220 Volt for HT/LT Panel
S&F 11 kv resin cast current transformer(250/5A)
S&F 11 KV potential Transformer complete
Preparing the outer surface of VCB panel indoor type by removing the old paint/removing the rusting and denting and painting with two coats of sythetic anamel paint of approved colour complete as specified and directed by Engineer-in-charge.
S&F in replacement of off load Change over switch in sheet metal enclosure 4 pole 415 volts side handle operation along with fixing arrangements with suitable nut, bolts, washers, including terminating the incoming/outgoing cables with suitable aluminum lugs/ferruls with propper crimping and testing comlete all as directed by Engr-in-Charge for 400 Amps
S&F in replacement of off load Change over switch in sheet metal enclosure 4 pole 415 volts side handle operation along with fixing arrangements with suitable nut, bolts, washers, including terminating the incoming/outgoing cables with suitable aluminum lugs/ferruls with propper crimping and testing comlete all as directed by Engr-in-Charge for 200 Amps
Disconnecting APFC panel carefully,removing the defective control device MCCB/MCBs,capacitors,indicator cum push button switches,relays,contacts,CTs,internal wiring, Cleaning all parts by CTC solution / emry paper as required and greasing the metallic and mechanical serviceable parts.
S&F relays BR 6000 suitable for 6 stage APFC panel Make:EPCOS/NEPTUNE
S&F relays BR 6000 suitable for 8 stage APFC panel Make:EPCOS/NEPTUNE
Programming and caliberation of APFC panel relay
S&F capacitor
S&F APFC panel cooling fan of size 120x120x38 mm ,frequency 5o Hz,power 18 W and speed-2600-2800 RPM.
Painting the Panel boards/DB Boxes/covers/DG Set/Accoustic Enclosures as required at site after scraping out completely the old paint with one coat of redoxide primer and two coats of synthetic enammel paint including carrying out minor welding works if reqired as directed by the Engineer in charge NOTE:Colour of paint shall be decided by the Engineer-in-charge.
S&F in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 250 Amps including taking down old unserviceable ON Load Change over switch for taking into credit.
S&F in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 400 Amps including taking down old unserviceable ON Load Change over switch for taking into credit.
S&F (in replacement) of MCB 32 Amps TP 3 pole 415 volts on pannel mounted type with breaking capacity 10 KA including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface
All as per Sl Item No. 33 above but for MCB 40 Amps TP
All as per Sl Item No. 33 above but for MCB 63 Amps TP
All as per Sl Item No. 33 above but for MCB 6-32 Amps SP
S&F (in replacement) of power contactor capacitor suitable for up to 12.5 KVAR duty 3 pole 415 volts on pannel mounted type including disconnecting the incoming/outgoing cable connections and re-connecting with suitable copper lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity.
All as per Sl Item No. 37 above but for Contactor suitable for above 12.5 KVAR to 20 KVAR
All as per Sl Item No. 37 above but for Contactor suitable for above 20 KVAR to 25 KVAR
All as per Sl Item No. 37 above but for Contactor suitable for above 33.3 KVAR to 50 KVAR
S&F illuminated push button switch suitable for APFC Panel
Demolition of Concrete of any description and in any position not otherwise specifically provided for
M/L for preparation of old steel surfaces of HT Feeder Pillar Box of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed
S&F in repair MCCB three pole 415 volts 50 Hz , 63 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB three pole 415 volts 50 Hz , 100 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 160 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 200 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 250 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 350 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 400 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 500 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair MCCB four pole 415 volts 50 Hz , 630 amps, with rupturing capacity 50 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
PSK Enterprises
PREMIER ENGINEERING SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .