| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.6 LAccepted-AOC | ₹29.6 L Quoted ₹31.4 L | 1 | Accepted-AOC AOC |
| 2 | 2₹32.2 L+₹85,826 (2.74%)Rejected-Finance 18 GOBINDPURA STREET NO 10 PO RAYON SILK MILLS PURANI CHUNGI CHHEHTRA AMRITSAR 143001 PB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹32.2 L+₹85,826 (2.74%) | 2 | Rejected-Finance Rejected |
| 3 | 3₹32.4 L+₹1.0 L (3.31%)Rejected-Finance | ₹32.4 L+₹1.0 L (3.31%) | 3 | Rejected-Finance Rejected |
| 4 | 4₹32.9 L+₹1.5 L (4.85%)Rejected-Finance | ₹32.9 L+₹1.5 L (4.85%) | 4 | Rejected-Finance Rejected |
| 5 | 5₹34.2 L+₹2.8 L (9.05%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹34.2 L+₹2.8 L (9.05%) | 5 | Rejected-Finance Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Jun 2025, 6:00 pmClosed
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
REPAIR/REPLACEMENT OF LT UG CABLE AN OTHER CONNECTED ITEMS OF EXTERNAL ELECTRIC AT VALLA AND OLD AMRITSAR CANTT AREA UNDER AGE B/R-II AT AMRITSAR CANTT
2025_MES_707996_1
GE/ASR-11/2025-26
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹90,000
1 Aug 2025
13 May 2025
19 Jun 2025
13 May 2025
12 Jun 2025
28 May 2025
14 May 2025 - 21 May 2025
Amount
Excavating in trenches n exc 1.5 metre wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 metre depth and getting out in soft/ lose soil complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and exceeding 1.5metre in depth but n.exc. 3 metre in depth for foundation for poles etc complete all as specified and directed.
Returning, filling including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil complete all as specified and directed.
Removing excavated materials(soils) to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for spreading of dry river bed sand for cushioning and covering the under ground cable in trenches all as specified and as directed. (Note : Punned down thickness 18 cm shall be measured)
Supply, laying in repair of PCC covers, class LV type-1 flat size 250mmx150mmx40mm, ISI marked complete all as specified and directed.
Supply, laying in repair of PCC covers, class LV type-2 flat size 300mmx180mmx40mm, ISI marked complete all as specified and directed.
Supply & laying in repair HDPE pipe 65mm bore for covering of LT cables etc. with all accessores complete all as specified and directed.
Supply and Laying in repair in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one complete all as specified and directed of following size (Excavation & earth work, sand cushioning & cable covers shall be measured and paid for separately) :- (a) 16 sqmm 4 core
(b ) 25 Sqmm 4 core
(c) 35 Sqmm 31/2 core
(d) 50 Sqmm 31/2 core
(e) 70 Sqmm 31/2 core
(f) 95 Sqmm 31/2 core
(g)120 Sqmm 31/2 core
(h) 150 Sqmm 3.5 core
(j) 185 Sqmm 3.5 core
(k) 240 Sqmm 3.5 core
(j) 300 Sqmm 3.5 core
Material and labour in reair for GI pipe light grade 100 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors complete for protection of cables complete all as specified and directed.
All as item No 20 above but 50mm dia tubes.
All as per Item No 20 above but 80 mm dia tubes
Material and Labour for cuttings of metaled or bitumenous road of required width and depth and making good the damaged Road by using old specifications complete all as specified and directed.
Material and Labour for repair to LT Panel board of any size with and including replacing the unserviceable MCCB, Busbar, jointig cable with proper lugs ,nuts , bolts and washers, cleaning the panel by using of CRC Soluation and repairing the panel door by using hinges and repairing the lock system, necessary welding, spray painting the complete LT Panel with two coats of synthetic enamel paint including preparation of old surface complete all as specified and directed. NOTES :(i) Rate for new Busbar, jointing cable, lugs, CRC Solution, nuts,bolts, painting and washers, hinges are deemed to be included in quoted rates. (ii) MCCBs shall measured and paid for separately but taking down is included in this item.
Supply and fixing MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA , fixed type(HBC Series),adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II complete all as specified and directed.
All as per item No 25 here in above but 200 Amps 25 KA breaking capacity.
All as per item No 25 here in before but 100 Amps 16 KA breaking capacity.
All as per item No 25 here in before but 63 Amps 16 KA breaking capacity.
Attending breakdown complaint of OH conductors of any size and repairing the conductorby using additional conductor of same size for fiing on poles incl binding wire etc. complete all as specified and directed (Note - All T&P required for attending the comlaint incl safety devices will be the contractor's responsibility)
Material and labour for spray painting to LT Steel tubular pole,9 m long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letters under yellow circle with alternative layers of black and white strip upto 1.5 mtr from GL complete all as specified and directed.
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator polymer type type switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 200 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement, assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as per site requirement and as specified by Engr Incharge , complete with DO fuses assembly with channel and one No. operating Rod of 25 mm dia bore medium grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including disconnecting and taking down the old unserviceable GOD & accessories and removal complete all as specified and as directed .
Material and Labour for checking of HT UG 11 KV XLPE faulty cable with HT UG cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as all as specified and directed. Approx length 500 running metre each Job. (The rate for excavation, removing of old cable, laying after repairs is demmed to be included in the rate quoted by the contractor).
Supply & fix in repair LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement as directed by Engineer-in-charge
Supply and Fixing in repair bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.15 mm thick CRCA steel duly powder coated and including 200 amp, 25 kA MCCB 4 pole, thermal magnetic based fitted in bus bar enclosure using 200 Amp rated bus bar, 25x10mm aluminium and RYB indication lamps duly protected by 2A SP MCB outdoor type welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed. Note - Height of the enclouser from ground level 0.5 metre .
Supply and Fixing in repair bus bar enclosure 800 mm x 600 mm x 200 mm made out of 3.15 mm thick CRCA steel duly powder coated and including100 amp, 25 kA MCCB 4 pole, thermal magnetic based fitted in bus bar enclosure using 250 Amp rated bus bar, 25x10mm aluminium and RYB indication lamps duly protected by 2A SP MCB outdoor type welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 ; Complete all as specified and as directed..Note - Height of the enclouser from ground level 0.5 metre..
Material and labour in repair for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia light grade is deemmed to be included in rate quoted (ii) Excavation and earth work in any type of soil is deemed to be included in the qouted rate.
Supply and fixing in repair ACSR conductor complete all as specified and directed Engr-in-Charge
Material and Labour for dismantling of cross arms complete all as specified and as directed.
Material and Labour for dismantling of insulators complete all as specified and as directed.
Supply and fixing in true vertical position steel tubular pole 11m long complete with cast iron base plate final taper plug, bolts, nuts and screws, tyoe 410 SP-55 confirming to relevant IS including one primer coat of red oxide and two coats of aluminimu spray paint and bituminous paint inside and botom portion, and providing circular bend 1 No of width 2 cm with alternative layers of black and white strip upto 1.5 m from GL complete including dismantling of old existing PCC pole and removal complete all as specified and directed. (Excavation & earth work shall be deemed to be included in qouted rate and PCC in foundation & coping shall be measured and paid for separately).
Supply and fixing in true vertical position steel tubular poles 9m long complete with cast iron base plate final taper plug incl. bolts, nuts and screws, type 410 SP-31 confirming to relevant IS including one primer coat of red oxide and two coats of aluminimu spray paint and bituminous paint on inside and botom portion and providing circular bend 1 No of width 2 cm with alternative layers of black and white strip upto 1.5 m fro GL including dismantling of old existing PCC pole and removal complete all as specified and directed.(Excavation & earth work shall be deemed to be included in qouted rate and PCC in foundation & coping shall be measured and paid for separately).
Material and labour plain cement conctere 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation of pole and similar work complete all as specified and directed.
Material and Labour for PCC (1:3:6) type C-2, (using 40mm graded crushed stone aggregate) as in coping of pole and similar work incl. necessary form work and finishing complete all as specified and directed.
Material and Labour for finding UG cable fault by necessary excavation & earth work and repairing the cable of various sizes with straight through joint complete all as specified and directed for the following :- LT cable 3.5/4 core 10 Sqmm to 35 Sqmm incl straight through joint (Note -Excavation and earth work complete shall be deemed to be included in quoted rate)
Material and Labour for finding UG cable fault by necessary excavation & earth work and repairing the cable of various sizes with straight through joint complete all as specified and directed for the following :- LT cable 3.5/4 core 50 Sqmm to 95 Sqmm incl straight through joint (Note -Excavation and earth work complete shall be deemed to be included in quoted rate)
Material and Labour for finding UG cable fault by necessary excavation & earth work and repairing the cable of various sizes with straight through joint complete all as specified and directed for the following :- LT cable 3.5/4 core 120 Sqmm to 300 Sqmm incl straight through joint (Note -Excavation and earth work complete shall be deemed to be included in quoted rate)
Material and Labour in repair for cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 to 95 Sqmm 3 core heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
Material and Labour in repair for cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 120 to 185 Sqmm 3 core , heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
Material and Labour in repair for outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 50 to 95 sqmm 3 core including testing after jointing complete all as specified and directed.
Material and Labour in repair for outdoor type cable end termination kit, heat shirnkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 120 to 185 sqmm 3 core including testing after jointing complete all as specified and directed.
Material and Labour in repair for outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 240 to 300 sqmm 3 core including testing after jointing complete all as specified and directed.
Material and Labour for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 m of tree both side of the OH line with JCB, Cutter and all tools, plants etc. all as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures. If any breakdown of line caused during punning shall be made good by contractor without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures, the contractor will be solely responsible for it.
SUN CHEMICALS (BID ID -3314445)
Bharat Builder (BID ID -3313698)
Rishi Construction Co (BID ID -3310849)
Raman Electric Trading Co (BID ID -3313869)
kailu construction co (BID ID -3314236)
B S TRADERS (BID ID -3314467)
SUN MANN ENGINEERS (BID ID -3314386)
diamond electrical (BID ID -3321280)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .