| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹8.3 L+₹51,156.77 (6.58%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹8.5 L+₹74,999.07 (9.64%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹10.0 L+₹2.2 L (28.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted with required category |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
7 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE (I) CIF (R) C/o 56 APO
UPGRADATION OF INCOMING POWER SUPPLY LINE WITH MAIN LT PANEL AT POTHA UNDER AGE (I) CIF (R).
2022_MES_506046_1
AGE(I)/R-42/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
POTHA
Class E and above and category b (i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,400
Yes
22 Mar 2022
5 Feb 2022
9 Mar 2022
5 Feb 2022
7 Mar 2022
20 Feb 2022
60 days
Amount
Supply and laying, LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric powere cable (heavy duty) with aluminium stardard condutor 1100volts grade cross sectional area 3.5 core 120 sqmm alongwith cable glands and aluminium lugs at LT panel and transformer etc complete all as specified and as directed by Engr-in-Charge.
Supply and laying, LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric powere cable (heavy duty) with aluminium stardard condutor 1100volts grade cross sectional area 4 core 16 sqmm alongwith cable glands and aluminium lugs at LT panel and transformer etc complete all as specified and as directed by Engr-in-Charge.
Supply, installation and commissioning and testing LT panel outdoor type size not less than 1.2 x 1.0 x 0.5 mtr double door (IP-54 Portection) floor mounted type CPRI type tested compartmentalised, made cut off 3.15mm thick CRCA sheet duly powder coated complete with copper bus bar (TPN) 800 Amps rating made up copper strip 50 x6 mm duly drilled holes for connection (TPN) and mounted on epoxy based insulators for 3 phase 4 wire 415 volts 50 Hz power supply system extended rotary handle Voltmeter ammeter (Digital type) indicator lamps (RYB) (indicator lamps should display colour of phase as well as voltage complete) internal wiring with suitable size of copper conductor PVC insulated and sheathed cable front and rear openable double door with locking arrangement angle iron frame made out from 40x40x6mm angle iron frame and grouting with PCC and foundation work and including the following items mentioned below:- Incoming:- (i) MCCB 3 phase 4 pole 630 Amps 36KA rupturing cap, ICs = 100% icu with adjustable thermal and fixed magnetic setting 415 volts 50 Hz AC Supply -01 Nos (ii) Digital voltmeter 0-500 volts - 01 set (ii) Digital voltmeter 0-400 amp- 01 set (iv) Phase indication lamp RYB with incation voltage in digital LED format (set of three - 01 Set) Outgoing:- (i) MCCB 3 phase 3 pole 200 Amps 25KA rupturing cap, ICs = 75% icu with adjustable thermal and fixed magnetic setting 415 volts 50 Hz AC Supply -01 Nos (ii) MCCB 3 phase 3 pole 160 Amps 25KA rupturing cap, ICs = 75% icu with adjustable thermal and fixed magnetic setting 415 volts 50 Hz AC Supply -01 Nos (iii) MCCB 3 phase 3 pole 100 Amps 25KA rupturing cap, ICs = 75% icu with adjustable thermal and fixed magnetic setting 415 volts 50 Hz AC Supply -03 Nos
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation or for shaft, wells, cesspits, manhole, pair house,laying of cable ,pole foundation,stay,laying of pipe etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in Hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick , all as specified .
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point and entire satisfaction of Engnr-in-Charge complete all as specified and directed
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Supply , installation,HT 11 KV outdoor gang operated air break switch suitable for horizontal or vertical mounting with drop out fuse having 12 insulators of rating upto 400 Amps incl taking down old all as specified and directed by Engr-in-Charge Note :- All the connected tripping/ fuse system shall be sleeved with coded colour as RYB.
M & L for lightning arrestor HT 11 KV 10 KA station class expulsion type complete with all fittings, transmission class, discharge, capacity 65 kilo Amp complete all as specified
Supplyng and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections used for security light connections from cable to beacket on poles, twin core cable flat or circular 4 sqmm solid conductor complete all as specified and as directed
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections used for security light connections from cable to beacket on poles, twin core cable flat or circular 10 sqmm solid conductor complete all as specified and as directed
Supply and fix ON load change over switch 200 amps 415 volts 4 pole 50Hz in sheet metal enclosure with side handel operated complete all as directed by Engr-in-Charge
Supply and fix ON load change over switch 125 amps 415 volts 4 pole 50Hz in sheet metal enclosure with side handel operated complete all as directed by Engr-in-Charge
Supply and fixing in replacement, LED Street light 120 watt (lumen efficeincy>130 lm/w) CCT 5700K New generation energy saving & environment firendly long life versatile pressure die-cast aluminum IP66 roadway luminaire with high power LED aslight source and impact Resistance IK07 suitable for 50-56 mm dia GI braket with all necessary connection complete all as specified and directed
M & L for cleaning, rubbing, preparation for painting all surfaces of 2 pole structure (Incl HT poles 2 Nos clamps etc) and painting all surfacese of the same with Aluminium paint 2 coat complete with black & yellow stripes (total 5 nos with 30 cm width from bottom of poles) complete all as specified and as directed by Engr-in-Charge
M & L for cleaning, rubbing, preparation for painting all surfaces of steel tubular poles 9 Mtr with security light bracket etc complete and painting all surfacese of the same with aluminium paint 2 coat complete with black & yellow stripes (total 5 nos with 30 cm width from bottom of poles) complete all as specified and as directed by Engr-in-Charge
CHOPRA CONSTRUCTIONS
M/S NARAYAN CONSTRUCTION
Jiwan Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .