Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 73 11TH CROSS SWIMMING POOL EXTN MALLESHWARAM BANGALORE KARNATAKA 560003 | BENGALURU URBAN | KARNATAKA | 560003 | Admitted-Finance |
Tender Value
₹45.7 L
EMD Value
₹91,465
Closing Date
20 Feb 2021, 4:00 pmClosed
EE(E)
BSNL Electrical Division2, WMS Compound, 47th Cross, 9th Main, 5th Block, Jayanagar, Bengaluru560 041
Short Notice Tender for Providing Electrical Installations and miscellaneous works at O/o CCA, DoT Cell, Amenity Block, Palace Road, Bengaluru
2021_BSNL_70113_1
47/2020 - 2021/BSNL ED-II /BGL
Open Tender
Electrical Works
Item Rate
210 days
CCA OFF AMENITY BLOCK
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
The Accounts Officer (Cash), O/o The CCA, KTK Circ
₹91,465
3 Mar 2021
13 Feb 2021
22 Feb 2021
13 Feb 2021
20 Feb 2021
13 Feb 2021
13 Feb 2021 - 20 Feb 2021
Amount
SUBHEAD - 1 ELECTRIFICATION
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required (a) 3 x 1.5 Sqmm
(b) 3 x 2.5 Sqmm
(c) 3 x 4 Sqmm
(d) 3 x 6 Sqmm
(e) 4 x 16 with 2 x 6 sqmm FRLS copper wire
Supplying & Drawing of UTP 4 Pair CAT 6 LAN Cable in the existing surface/recessed Steel/PVC conduit as required. (a) 1 run of cable
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.(a) 2 pair
Supplying & fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (a) 20 mm size
(b) 25 mm size
(c) 32 mm size
Supplying and Fixing of following size trunk box (Polycarbonate cable management) system on the surface of wall / floor / ceiling / on the the existing cable tray with necessary connected accessories like bends, Elbows, Tee, etc as required. [Make:MDS/Legrand/ MK India / LK or any Similar Superior Make] (a) 32 mm x 12.5mm
(b) 25 mm x 25mm
(c) 50 mm x 50mm
(d) 100 mm x 50mm
(e) 50 mm divider
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Supplying & fixing of 36W 600mm x 600mm size recess/surface type LED Luminaire suitable for working on 230V 50Hz AC supply directly on ceiling/wall, including connection with 1.5Sqmm FR PVC insulated, copper conductor, single core cable etc as reqd. [ M/s Crompton Greaves LCTLR-36-CDL, LCPL-36-CDL/TL (2X2) LCTLS-36-CDL / M/s Havells 36W 865 2x2 or Similar superior make]
Supplying & fixing of 12W recess/surface type LED round/square Luminaire suitable for working on 230V 50Hz AC supply directly on ceiling/wall, including connection with 1.5Sqmm FR PVC insulated, copper conductor, single core cable etc as reqd. [ M/s Crompton Greaves LCDN-12-CDL/ LCDSPL-S-12-CDL/ M/s Havells 12W 840 or Similar superior make]
Supplying & fixing of 4ft 20W LED fitting with LED tube, driver suitable for working on 230V 50Hz AC supply directly on ceiling/wall including connection with 1.5Sqmm FR PVC insulated, copper conductor, single core cable etc as reqd. [ M/s Crompton Greaves, M/s Havells or superior make]
Supplying & fixing of following modular switches/sockets, on the exiting modular plate & switch box including connections but excluding Modular plate, etc as reqd (a) 5/6 A switch
(b) 3 pin 5/6 A socket outlet
(c) 15/16 A switch
(d) 6 pin 15/16 A socket outlet
Supplying & fixing RJ11 Telephone Jack with shutter on the exiting Modular plate & Switch Box etc as required
Supplying and fixing GI Modular Box & Modular base & cover plate with RJ-45 socket suitable for CAT 6 LAN cable (Legrand/Crabtree or Similar superior make) including LAN End termination for CAT 6 Cable, providing jack, crimping etc as required.(D-Link or SS Make)
Supplying & fixing Modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 1 or 2 Module (75 mmX75 mm)
(b) 3 Module (100 mmX75 mm)
(c) 4 Module (125mmx75mm)
(d) 8 Module (125mmx125mm)
(e) 12 Module (200 mmX150 mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (a) 1 or 2 Module
(b) 3 Module
(c) 4 Module
(d) 8 Module
(e) 12 Module
Supplying and fixing of following way, horizantal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator.(a) 4 way, (4+12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 Way Double door
Supplying & fixing of following DP MCBs, SP MCBs of 'C' Curve, 10KA Breaking capacity in existing MCB DB suitable for working on 230V, Single phase, 50Hz, AC supply etc, as reqd (M/s Hager or superior make) (a) 63A 4P MCB
(b) 32A DP MCB
Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suiable for inductive load if following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
Supplying & fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following electrical accessories in the existing Emergency light MCB DB i/c modification in the door, interconnection etc., as required. (a) RED & GREEN LED indicator lamps (Vaishno -22.5mm/Rishab/L&T or ss make)
(b) AC to AC MXO 22E (2 NO+2NC) control relay (Auxillary contactors). (M/s L&T - Cat No.CS94020 or Schneider Electric / Siemens/ Lakshmi(LECS) make)
(c) Push Button (Vaishno -22.5mm Rishab/L&T or ss make)
Supplying and Fixing of weather proof box made of SMC / Polyvinyl with ingress protection rating of IP 66 for outdoor installation and size of approximate dimension 200mm x 140mm x 95mm with 1 No 6A DP MCB & Connector i/c fixing, locking hinges, knockouts for cableentry, interconnections etc as reqd. [Make: Hensel enycase Sintex or equivalent make & model make]
Supplying & fixing of 50 Watt, LED type Outdoor Flood Light fixture with IP 66 protection and minimum 60° beam angle, drivers, accessories and suitable for mounting on existing masonry / CC pedastal / MS angle iron stand in ground, above flood level, duly wired ready to use, suitable for 230 Volts. 50 Hz. AC supply including inter connection, testing commissioning etc., complete as reqd.,(Make: Crompton LFL-50-CDL/60-M,Jaquar/Philips /Wipro or equivalent make & model)
Supplying and fixing inverted pyramid tripod type LED bollard with soft 360 degree light, IP 65 protection, Resistant to corrosion, better optics for uniform distribution [LED Post Top Lantern]. (Make: Crompton Greaves or SS make)
Supplying and fixing trunk box made of 16SWG MS sheet with openable covers including powder coated painting to match with existing panels/DB etc as reqd.
Supplying and Laying of Electrical insulating 2mm thick Rubber Mat in accordance with IS 15652/2006 (for 3.3KV) etc as required.
Supplying and Fixing 32 mm dia GI bracket for fixing of street light Fitting including necessary interconnecting wiring, clamps and bolts and nuts etc as required.
Supplying and laying 2 core 6 sqmm PVC insulated, PVC sheathed/XLPE insulated Aluminium Conductor Armoured UG cable of 1.1KV grade on surface of wall including clamping, etc as required
Supplying & making end termination with brass compression gland and aluminium lugs for 2 core 6 sqmm PVC insulated PVC sheathed/XLPE Aluminium conductor armoured UG Cable including connections etc as required.
Supplying and laying of following size HDPE PVC pipes of pressure handling capacity (6kgf/sqcm) along with accessories in the following ways as per dept spec etc as reqd. (a)40mm dia heavy duty rigid PVC pipe On surface of wall/floor including support /clamping/cutting the concrete etc as reqd. ISI marked
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. a required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and Fixing Red LED type "Engaged" signage board (Apprx Dimension 15"L x 5"H) with curved acrylic suitable for hanging from ceiling/ fixing on surface of wall
Supplying and Fixing Red LED type "Meeting in Progress" signage board (Approx Dimension 15" L x 5" H) with curved acrylic suitable for hanging from ceiling/ fixing on surface of wall
SITC of 300mm sweep, 1350 rpm exhaust fan, metal body, 4 blades suitable for 230V AC supply i/c s/f Aluminium frame in the existing opening / window, including making good the damages etc as required (crompton/usha/ khaitan/bajaj/ orient or any Similar Superior make)
Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required.
SITC of 24-Port 10/100/1000 Gigabit SP Switch (LAN Switch) customer premises equipment (CPE) switch for Ethernet deployments, Comprehensive security features for robust multitenant separation, Optimized for triple-play (VoIP, video, and data) services, Service provider provisioning and management features etc suitable for RJ-45 termination as required. (Cisco 24-Port 10/100/1000 Gigabit SP Switch or Similar Superior make)
SITC of RACK FOR MOUNTING SERVICES: Supply Installation Testing and Commissioning of 19" Rack 650mm depth, 12U high amplifier rack assembly for housing 1 No. Amplifier, 1 no. Main Console, CD Player etc made of aluminum channel, with side and rear panels made of 14 swg. Powder coated sheet steel front transparent perplex door and with rails, rollers & bearings. Fans provided at the top for ventilation. Side panels will be ventilated type. The rack shall be powder coated of approved color and spare 'U' shall be covered with blank panels.
Sub Head - II ITC of Spilt AC units : ITC of 1.5 TR Inverter type wall mounting split AC unit operating on 230V, 50Hz AC supply, filled with R-410 refrigerent gas, having nominal cooling capacity of 4500 Kcal/hr (5.2 KW), minimum room air flow of 700 cub mtr/hr and minimum Indian Seasonal Energy Efficient Ratio (ISEER) of 3.5, and Minimum 3 star rated, performing functions like cooling, dehumidifying, air circulating, filtering etc along with the hot and cold refrigerent copper piping up to 5 Mtrs, cordless remote, including transportation etc. complete as per required. ( Make: Panasonic/Universal comfort (Voltas) / Hitachi / LG / Carrier / Daikin / Mitsubishi / O-General / Videocon / Bluestar / Samsung)
Supplying & Laying 50 mm Rigid/flexible PVC pipe with accessories for protection of refrigerant piping including clamping etc as required
Supplying & fixing of prefabricated powder coated MS stand grouting, painting and minor civil works etc complete as required. (to be provided wherever wall stands are not feasible)
Providing and fixing additional 3 x 2.5 Sqmm PVC insulated copper conductor cable over and above 5mtrs length suitable for the above AC units wherever required including termination as required.
SITC of wall mounting type voltage stabilizer cum starter with 170-270 volts input voltage range and output range of 220 volts +/- 10% with auto start facility, time delay over load relay Suitable for 1.5TR AC units as required. (M/s. V Guard -VG 500 or SS Make)
Sub Head III-SITC of audio conferencing System : SITC of Central Amplifier having digital recorder for recording the proceedings, with playback of the pre-recoded messages, switchable send/return facility in central amplifier, facility of feeding two independent groups of delegate units, Three MIC inputs and one Aux input for various user applications etc as required. The amplifier shall be 19" rack mountable and suitable for operation on 230V AC mains and 24V DC Supply. (Ahuja make -CMA 5400 or SS Make)
SITC of Chairman unit-input-line with gooseneck microphone, output line, headphone socket, speaker with max input 300mW, Controls-priority switch, talk switch, speaker volume and head phone volume control etc as required.(Ahuja make -CMC 5100 or SS Make)
SITC of Delegate unit -input-line, output line, headphone socket, speaker-max input 300mW, Controls-talk switch, speaker volume and head phone volume control etc as required.(Ahuja make -CMD 5200 or SS Make)
SITC of Amplifier 120Watts, 5 Mic & 2 Auxilary Inputs 19" rack mounted PA mixer amplifier, Freq.Resp:60-15,000Hz, bass/treble & master control on front panel etc as required.(Ahuja make -SSB 120 or SS Make)
SITC of false ceiling mounting Speaker with 30 watt RMS power taps: 30/15/7.5 W on 100V, Freq.Resp: 80-20,000Hz etc as required.(Ahuja-CSD6303T or SS Make)
Supplying & Laying of following miscellaneous items for installation of the above system etc as required.(a) 8 core shielded cable
(b) 2 Core flexible Speaker cable
(c) Connectors/accessories
SITC of UHF band frequency conference wireless microphone system with high quality wireless gooseneck microphone, Mic-Receiver-True Deliversity, Frequency-50HZ to 16KHZ, Polar pattern-cardioid, Powered with 2x1.5V AA Pencil Cells for each unit etc as required. (M/s Studio Master XR 20C or equivalent)
SITC of UHF band frequency wireless microphone system with 2H Wireless (2 Hand Microphone), Mic-Receiver-True Deliversity, Frequency-50HZ to 16KHZ, Polar pattern-cardioid, Powered with 2x1.5V AA Pencil Cells for each unit etc as required. (M/s Studio Master XR 40HH or equivalent)
Sub Head IV-SITC of Projectors and associated works : SITC of 55" (139 cm) 4K HDR LED display Smart TV with all accessories such as power cord, power adaptor, remote control to be fixed on the existing wall/partition with suitable mounting. The TV shall support wifi, Bluetooth, Ethernet inputs, HDMI inputs, smartphone connectivity options etc as required (M/s Sony or similar superior make)
SITC projector with LCD 3600 lumens, Resolution 1024 x 768 XGA, Aspect Ratio 4:3, 15000:1 Contrast Ratio, with min 10000 lamp hours along with supplying and fixing ceiling mounting kit including VGA, Power cord of standard length etc as required. (M/s EPSON X41 XGA 3600 Lumens LCD)
SITC of motorized projector screen of size about 130" diagonal with aspect ratio 16:10 along with necessary supports, aligning etc as required
Supplying and laying of following type of cables of specified length with end connectors etc as required (M/s Kramer or similar superior make) (a) 25 mtr HDMI cable
(b) 25 mtr VGA cable
(c) 1.8 mtr HDMI cable
(d) 1.8 mtr VGA cable
(e) 1.8 mtr Audio cable
SITC of the following HDMI/VGA splitters and switchers suitable for use with the above projectors etc as required (a) 1 in - 4 output HDMI Splitter
(b) 4 in - 2 output HDMI Switcher with Audio
Sub Head V-SITC of VRF Units : SITC of Variable Refrigerant Flow (VRF) Air Conditioning System comprising of Modular type high efficiency DC Scrolls/Single/Multiple Compressor with DC inverter, High efficiency heat transfer cooling coil suitable for Environment friendly R410a refrigerant, i/c initial fill 410a refrigerant as supplied with unit, Air cooled propeller type condenser fan with DC motor drive, interconnecting piping, suction line insulation etc and microprocessor control panel suitable for automatic operation, High Speed calculation inverter control, active oil control mechanism incorporation all asafety functions etc as per attached specifications (HP Rounded off to nearest value) (Make: Voltas/Bluestar/Daikin/Cariier,Hitachi,Toshiba) (a)12 HP
SITC of Ceiling suspended VRF four way/Round flow Cassette unit with low noise, multi speed fan, multi row cooling coil, insulated extended drain pan, filter, cordless remote control (TR Rounded off to nearest value) (Mke: Voltas/Blue Star/Daikin/Carrier/Hitachi/Toshiba). (a) 3.0 TR Cassette unit
Providing, Fixing, testing and commissioning of Variable refrigerant flow distribution REFNUTS in the suction & liquid lines for various sizes of copper refrigerant piping including insulating the refnut etc. as required.
Supply of Cordless Remote and Receivers
Carrying out pressure testing of total VRF system (total copper piping network of both indoor and outdoor units) including purging with necessary gas, Vacumizing, Leak testing, etc. as per attached specifications (a) 12 HP
Supply & Filling additional fresh refrigerant gas R410a including testing and commissioning (Manufaturer recommended)
Supply fabrication & Installtion of suitable MS base frame for outdoor units complete with 2 coats of red oxide & epoxy paintings, vibration isolated pads, supports, hangers, railing, brackets (a) Outdoor unit modules
Supply, Installtion, Testing & Commissioning of seamless heavy gauge eddy current tested copper piping. Refrigeration piping will have to be taken in the existing piping rack/G.I Cable tray & cover with necessary support, saddles, necessary bends, tees & fittings. (a) 28.6 mm with 19mm thick insulation
(b) 22.1mm with 19mm thick insulation
(c) 19.1mm with 19/13 mm thick insulation
(d) 15.9 mm with 19/13mm thick insulation
(e) 12.70 mm with 13mm thick insulation
(f) 9.5 mm with 13 mm thick insulation
(g) 6.3 mm with 13 mm thick insulation
Supply, Laying, Testing & Commissioning of ISI marked CPVC insulated condensate water pipping complete with all floor, wall & Ceiling supports, fitting, U trap/seal to the nearest drain point (a) 25mm Dia (Minimum wall thickness 3.38mm) with insulation
(b) 32mm Dia (Minimum wall thickness 3.38mm) without insulation
Supply & Installation of control cum transmission wiring between ODU & IdU, 2Core X 1.5 Sqmm Copper Shielded unarmoured cable with PVC conduits.
Supply & Installation of power cable between the power socket and indoor unit, IDU to ODU etc, with Copper flexible cable 4Core X 2.5 Sqmm
Supply & Laying of copper armoured cables for each of the ODU's from customer 4pole MCB to VRF ODU/LT panel to VRF AC panel.(a) 4C X 10 Sqmm
Providing fabricated MS/ aluminium roofing sheet, Weldmesh frame size 10G of 2"x1" grid and 38 x 38 x 5mm MS angle, making door with following items including transportation, cutting to the required size, fixing with suitable hardware, grouting, etc as required (a) 2" X 1" size 10G MS weldmesh
(b) 38 x 38 x 5 mm MS angle
(c) 0.6 mm Thick Aluminium sheet i/c U Clamps, bolts, nuts, tar washers, etc
(d) Locking arrangement with 7 Lever lock & keys
Painting of existing angle iron weldmesh of 12G of size 2"x1"/ 1" x 1" along with frame and support channels with 2 coat of green colour synthetic enamel paint i/c cleaning the rusted parts etc as reqd.
Sub Head VI-CONVENTIONAL AUTOMATIC FIRE DETECTION SYSTEM (ONLY FOR CONFERENCE ROOM): Supplying, Installing, Testing and Commissioning of microprocessor based conventional type, Fire Alarm main control panel suitable for working on 240 V AC Supply and 24 V DC, power supplies, consisting of 4 Zones with necessary controls, audio/visual indications for fire, fault i/c relay output unit for mimic & providing 2 Nos. 12 V, 7Ah built-in sealed maintenance free batteries with battery charging circuit i/c removing existing defective panel etc. complete as required (Make: Agni / Ravel / Naveen / Carmel)
SITC of Photo Electric type smoke detector with base plate i/c removing existing defective detector etc., as required
SITC of Heat detector with base plate, including connections with existing wires, testing etc., as required
SITC of Electronic Hooter including connections with existing wires/cables, testing etc. as required
Supplying and Fixing Manual call point including connections with existing wires/cables, testing etc. as required
Supplying and Fixing Response indicator including connections with existing wires/cables, testing etc. as required
Supply and Laying of additional 2 x 1.5 sq.mm PVC/XLPE insulated, PVC sheathed, FRLS armoured copper cable on surface of wall /ceiling with necessary glands, sadels etc., complete as required. (Make: Any ISI marked cable with FRLS insulation)
Supplying & Fixing MS metal Box of following size (Nominal size) on surface of with suitable size phenolic laminated sheet cover in front including panting etc., as reqd (a)100mmx100mmx60mm deep
Supply & making end termination with brass compression gland suitable for 2x1.5 sqmm copper cond UG cable etc., as reqd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .