Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 CrAdmitted-Finance | ₹6.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.1 Cr+₹14.6 L (2.44%)Admitted-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | ₹6.1 Cr+₹14.6 L (2.44%) | L2 | Admitted-Finance |
| 3 | L3₹6.5 Cr+₹49.1 L (8.20%)Admitted-Finance | ₹6.5 Cr+₹49.1 L (8.20%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Sky Engineers L1 | M/S Rather and Sons L3 | M/S RATHER CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|
| 1.00Note: (i) Please refer Schedule 'A' Notes of tender documents. (ii) Unless otherwise specified, earth work and excavation shall be measured and paid separately. (iii) The Schedule 'A' Part - IX to X are not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. (iv) In case rate of any item is not quoted by the bidder, the rate for the same item will be considered as zero and no claim in this regard at later date will be entertained. | ||||||
| 2.00LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS | ||||||
| 2.01 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. | 1 | Each | 4,84,50,000 ₹4,84,50,000 Lowest | 5,00,00,000 ₹5,00,00,000 | 4,90,00,000 ₹4,90,00,000 |
| 2.02 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-II. | 1 | Each | 4,90,000 ₹4,90,000 Lowest | 5,00,000 ₹5,00,000 | 5,00,000 ₹5,00,000 |
| 2.03 | Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS carried forward from Pre-Priced Schedule 'A' Part-III. | 1 | Each | 1,30,000 ₹1,30,000 Lowest | 2,00,000 ₹2,00,000 | 1,50,000 ₹1,50,000 |
| 2.04 | Lump sum price worked out by the contractor for ROAD,PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. | 1 | Each | 11,50,000 ₹11,50,000 Lowest | 15,00,000 ₹15,00,000 | 12,00,000 ₹12,00,000 |
| 2.05 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-V. | 1 | Each | 62,000 ₹62,000 | 1,00,000 ₹1,00,000 | 60,000 ₹60,000 Lowest |
| 2.06 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. | 1 | Each | 3,50,000 ₹3,50,000 Lowest | 3,50,000 ₹3,50,000 Lowest | 3,50,000 ₹3,50,000 Lowest |
| 2.07 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. | 1 | Each | 6,50,000 ₹6,50,000 | 6,00,000 ₹6,00,000 Lowest | 7,00,000 ₹7,00,000 |
| 2.08 | Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. | 1 | Each | 4,90,000 ₹4,90,000 Lowest | 6,00,000 ₹6,00,000 | 6,00,000 ₹6,00,000 |
Tender Value
₹4.1 Cr
EMD Value
₹4.9 L
Closing Date
4 Nov 2025, 6:00 pmClosed
CE 31 Srinagar Zone
HQ CE 31 Srinagar Zone
PROVISION OF VEHICLE REPAIR BAY FOR LT AND HEAVY VEH ALONG WITH TECH SECTIONS AT DAWAR UNDER GE 874 EWS
2025_MES_715778_3
800160
Open Tender
Civil Works
Lump-sum
600 days
GE 874 EWS
As per tender documents
12 documents required · 12 mandatory
₹2,000
GE 874 EWS
₹4.9 L
Yes
10 Nov 2025
4 Oct 2025
6 Nov 2025
4 Oct 2025
4 Nov 2025
18 Oct 2025
4 Oct 2025 - 8 Oct 2025
Amount
Note: (i) Please refer Schedule 'A' Notes of tender documents. (ii) Unless otherwise specified, earth work and excavation shall be measured and paid separately. (iii) The Schedule 'A' Part - IX to X are not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. (iv) In case rate of any item is not quoted by the bidder, the rate for the same item will be considered as zero and no claim in this regard at later date will be entertained.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I.
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-II.
Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS carried forward from Pre-Priced Schedule 'A' Part-III.
Lump sum price worked out by the contractor for ROAD,PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-IV.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-V.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VI.
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-VII.
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-VIII.
INTERNAL ELECTRIFICATION WORKS (SCHEDULE 'A' PART-IX)
S & F in replacement sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following:- (a) MCCB 3 POLE 125 AMPS AC 415 VOLTS 16 KA=01 No as incoming and 02 nos. MCB TPN 63 Amps 10kA, Isolator TPN 40 Amp, MCB SPN 40 to 63 Amp 240V 10 kA. Note :-(i) The DB shall be VTPN. The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(ii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iii) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (v) MCCB's and MCB's should have a same make as of DB.
S & F highbay luminaire of LED light 70 watt, at any height in hangers/work shop closed version with energy saving environment friendly and aluminium alloy pressure die cast housing with epoxy powder coated LED IP 65 luminaire with high power LED as light source complete and with in built surge voltage protection of 10 KV and with covered tempered protective toughened glass including taking down old light fitting complete all as specified and directed. Make:- Cat Part No Iliosbayplushbp70Wled857Sp90Dtopc of Havells or equivalent of Makes as specified in tender documents.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire with 15 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or main switch or as directed including earthing pit in PCC (1:3:6) type C1 for chamber and pre-cast RCC cover of size 380 x 380 x 40 mm, frame of angle iron 25mmx25mmx3mm with lugs 02 Nos and with 8 mm dia MS bar handle made to shape, 20 mm dia GI light grade pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. NOTE :- (For Internal Electrification Works = 04 Nos and For external Electrification Works = 01 No).
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25 x 4mm as earthing lead by means of bolt, nuts check nuts and washers with 32 mm dia GI pipe "medium grade" for protection of earth lead and connected to control board or main switch or as directed including earthing pit in PCC (1:3:6) type C1 for chamber and pre-cast RCC cover of size 380 x 380 x 40 mm, frame of angle iron 25mmx25mmx3mm with lugs 02 Nos and with 8 mm dia MS bar handle made to shape, 20 mm dia GI medium grade pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. NOTE :- (For LiInternal Electrification Works = 02 Nos ).
Notes for item Nos 3.03 & 3.04 : (a) The quoted rate shall be deemed to include the cost of excavation & earth work in any type of soil. (b) The quoted rate shall be deemed to include the cost of charcoal and salt in alternate layers; galvanised wire /strip and GI light grade protection pipe and GI light grade watering pipe. (c) The quoted rate shall be deemed to include the cost of funnel, wire mesh, lugs, PCC, RCC, frame work and including provisions of testing of test point, connecting to test point and all the tests on completion. (d) Any variation in length shall be adjusted through deviation order.
S & F of LED bulb 9 watt complete all as specified and directed.
EOT CRANE WORKS (SCHEDULE 'A' PART-X)
Supply, installation and testing of Double Grider (EOT) crane, box type having lift 6.0 Mtr & Span 16 mtr conforming to IS 807/3177 ,II Indoor type and comprising of the following complete all as specified and directed. (a) Main host safe working load 02 Tons (2000 Kgs) (b) Span 16 Mtr and longitudinal travel-25 mtr (c) Height of lift -6.0 Mtr (d) Operation:-Floor operation from pendant push button control station (e) Main hosting speed with AC drive (3 to 3.5 Mtr/Minute) (f) Cross travel speen (10 Mtr/Minute) (g) Long travel speed (10 Mtr/Minute) (h) main host motor rating:03HP or higher as recommended by manufacturer (j) Cross travel motor rating: 0.5 to 1 HP or higheras recommended by manufacturer (k) Long travel motor rating:twin drive 0.5 to 1 HP (2 Nos) each with gear box Note for (j) & (k) : Make of Crane motor:Kirloskar/Crompton and Greaves or equivalent
(i) Main hoist wire rope dia:12mm (m) Main hoist Nos of fallas : Two (n) Wire rope construction : (6X36)8mm x 4 falls ( Make Usha Martin) ISI marked (o) Main Grider-02 Nos (Box type) of size as per design of manufacturer (p) Over load capacity:25% (q) Rail size: 40mm SA BAR (r) Wheel: MS with bronze coating on tread Note:-(i) The double girder crance shall be suitable for working on 415 volts,3PH,50HZ AC supply and shall be complete with following of crane of capacity 02 ton as specified above (a) Main frame (b) Bridge/Box Grider (c) End carriages (d) Trolly with frame (e) CRAB
(f) Buffers (g) Gear with Gear boxes (h) Shafts (j) Rope Drum (k) Rope sheaves (l) Wire ropes (m) Wheels n) Lifting hook (o) Brakes Motors, Limit Switches,control panels, pendant push button station, Micro speed arrangements wiring etc all as per standard specification of manufacturer (p) 02 Nos of service platforms all as per standard specification of manufacturer (q) Make of contactors : L&T/siemens or equivalent as specified in tender.
Notes (ii) (a) Line diagram for the crane shall got approved from AO before installation (b) Any minor modifications required for sucesful operation of crane shall be carried out by contractor within over all cost quoted.(c) Trial run of crane shall be carried out for a period of one month. Only on sucessful completion of trail completion shall be issued by GE (d) Make of crane (i) M/S Hecules Ltd, (ii) M/S Mukund Iron & steel (iii) M/S TIB Udhyog (iv) M/S Rock well Hoisto Cranes Pvt Ltd (v) M/S NRS TIIB & Co (e) For Long travel:- Main grider with bracket and 12mm thick plate and 50mm sqbar rail shall in scope of supply of crane manufacturer (f) Copper coductor cable of size 4 sqmm 4 core or as recommended by the manufacturer from outdoor type feeder pillar box installed outside the sheeds to control panel of individual crane shall be supplied with in overall cost qoted (g) Testing of Crane shall be out in pesence of Rep of Accepting Officer as per IS standards, necessay load is to be arranged by contractor at site. (h) Pre dispatch testing/inspection shall be carried out in premises of manufacturers site in presence of the Rep of Accepting Officer.
Note (iii) MAKE OF STANDARD BOUGHT OUT ITEMS AS UNDER:- a) MOTORS: CROMPTION/KIRLOSKAR/BBL/SIMENS/LHP b) BRAKES: SPEED-O-CONTROL/PETHE/BCH/JAISON'S c) LIMIT SWITCH : SPEED-O-CONTROL/PETHE/BCH/JAISON'S d) PENDENT CONTROL: SPEED-O-CONTROL/JAISON'S/SCHNYDER e) CONTACTORS: L&T/BCH/SCHNYDER/T.C.FRANCE/L.S f) OVER LOAD RELLAY l L&T/BCH/SCHNYDER/T.C/L.S. g) HRC FUSES: L&T/BCH/EE/GE/ESSEN/SCI h)CABLE:PLAZA/FINOLEX/POLYCAB/ALCON/SWADESHI. J)WIRE ROPE:USHA MARTIN/FORT WILLIAM/MAHADEV k) WIRE ROPE DRUM: JAISON'S l) VF DRIVE: ABB/SIEMENS/L&T/BCH/DELTA/BOSCH m) WHEELS: JAISON'S (n) GEAR BOX : JAISON'S o) COUPLING:JAISON'S/ARISTOFLEX/CRYSTAL p) BEARINGS: SKF/TATA TIMKEN/FAG/ROMANIA/F.K/N.T.N (q) HOIST:JAISO
LIGHTENING PROTECTION WORKS (SCHEDULE 'A' PART-XI)
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolt, nuts check nuts and washers of galvanised iron with 40 mm dia GI pipe "medium grade" for protection of earth lead and connected to control board or main switch or as directed including earthing pit in PCC (1:3:6) type C1 for chamber and pre-cast RCC cover of size 380 x 380 x 40 mm, frame of angle iron 25mmx25mmx3mm with lugs 02 Nos and with 8 mm dia MS bar handle made to shape, 20 mm dia GI medium grade pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. NOTE :- (For Lightening Protection Works = 08 Nos, for external Electrification Works = 02 Nos and for DG Set Works = 06 Nos)).
Note : (a) The quoted rate shall be deemed to include the cost of excavation & earth work in any type of soil. (b) The quoted rate shall be deemed to include the cost of charcoal and salt in alternate layers; GI strip and GI medium grade protection pipe and GI medium grade watering pipe. (c) The quoted rate shall be deemed to include the cost of funnel, wire mesh, lugs, PCC, RCC, frame work and including provisions of testing of test point, connecting to test point and all the tests on completion. (d) Any variation in length shall be adjusted through deviation order.
EXTERNAL WATER SUPPLYWORKS (SCHEDULE 'A' PART-XII)
M&L for Cutting of existing steel tubing 80mm dia for alterations or additions for making branch connection and inserting the Tee of size 80 x 80 x 25 mm size and union 80mm etc including threading and fitting etc complete all as specifed and directed.
M&L for Construction of RR masonary staging for over head tank 2.4mtr from ground level PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete and brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in CM 1:4 with plastering and rendering 15 mm thick on fair faces of brick work or concrete surface in CM 1:4 including applying three coat of white wash including preparation of new surface of wall complete all as specified and directed.
Supplying, hoisting and fixing of Rotational moulded polyethylene water storage tank, HDPE, triple layered white colour of capacity of 1000 litres (cuboidal or cylindrical as approved by Engineer-In-Charge) vertical with closed top), for hoisting into position either inside or outside of building, connecting up pipes, securing access covers etc., with monkey-proofing mechanism, hoisted and fixed in position Complete all as specified and directed.Note:- Monkey proofing mechanism shall be measured and paid for separately under appropriate item of this schedule
S&F of Lagging to pipes 20mm bore used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144Kg/Cum conforming to IS-9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh and covered with 0.01mm aluminium foil, complete all as specified and directed.
EXTERNAL ELECTRIFICATION WORKS (SCHEDULE 'A' PART-XIII)
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, LT Panel Outdoor type, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars of 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring not less then 4 Sqmm with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming (i) MCCB 4 pole 415 volts 100 Amps with 25kA-01No (ii) Voltmeter 0-500 volts, square, 144 mm, digital type, - 01 No (iii) Ammeter size 144 mm, square dial, digital type, - 01 No (iv) LED Indicating lamps : 01 set of three (v) Current & Potential Transformer as per manufacturer design : 01 Nos (b) Outgoing (i) MCCB 4 pole 415 volts 100 Amps with 16 kA-01Nos (ii) MCCB 4 pole 415 volts 63 Amps with 16 kA-01Nos Note:- Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Supply and fixing LED street light luminaries 70/72 Watt having shall be made of single piece Aluminium Die cast with powder coated in RAL-7032 shade with heat distribution fins onhousing with UV stabilized toughned flass cover and should have secondary lens on each LED for better light distribution .The system luminaire efficacy should be > 110 LM/W with high power LED of Philips/Osram/Cree/Nichia Make.LED driver should be potted and BIS certified with efficiency > 85 % frequency 50 HZ,Operating voltage range 120V-270V,current not more than 0.320 Amp,PF 0.95, THD (I) < 10 %, supported with 5 KV internal and 10 KV external SPD, Humidity 10% to 90 % RH, working temperature - 20⁰ C to 50⁰ C lige expectancy of LED should be 50000 burning houres with minimum 70 % initial lumene maintained, CRI >70 , complete all as specified and directed
S&F of multistranded copper conductor cable PVC insulated , served with inner sheathing of PVC and overall PVC sheathed of size 1.5 sqmm 3 core for street light connection complete all as specified and directed.
S & F of GI bracket made out of GI pipe light grade of bore 40mm 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete all as specified and directed.
Supply and fixing of street light control box made of Engineering plastic one piece moulding control box with locking arrangment made out of HDPE and FI clamp 25 x 3mm complete of dimensions in mm +/-10%(333x233x120) including MCB SP upto 6 Amp 240 Volts complete with 02 Nos aluminium busbar or terminal two nos (Phase and Neutral with colour coding) of rating 63 amps for single phase and neutral on porcelain based insulators complete all as specified and directed..
DG SET WORKS (SCHEDULE 'A' PART-XIV)
Supply, installation, commissioning and testing of 82.5 KVA Liquid (Water) Cooled silent DG Set as per latest CPCB norms,comprising of Liquid Cooled Diesel Engine Model developing minimum 102 BHP @1500 RPM 82.5 KVA Alternator rated at Three Phase, 415 Volts, 50 Hz, 0.8 PF @ 1500 RPM both mounted and aligned on a common MS Base frame complete with MS fuel Tank, Manual Control Panel, Residential exhaust silencer, AVM pads fitted on baseframe, 12 Volts Battery , battery leads, 1st fill of Lube oil all housed in sound proof acoustic enclosure protected with asbestos rope independently supported from engine to outside power house upto 1 mtr, AVM pads foundations as per manufacure design battery start with suitable size of cable for connecting upto panel board . DG Set should be capable of operating in temperture range (-25° C to + 35°C) fitted with Cold starting kit with and including the following .
(A) Prime mover Vertical diesel engine of suitable capacity water cooled closed circuit as per BS-649 or IS-10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. The DG Set shall be capable of running 24hrs continuously with 10% over loading for one hrs continuously in every 12 hrs as per BS -649. Engine shall be eqipped with all standrd fitting and mounted on common base frame with following fittings. (a) RPM cum hour meter (b) Barttery charging Ammeter ( c) ignition key and starting with push button switch (d)Lubricating Oil pressure gauge (e) Electronic governor controlling Oil temo gauge (g) 12/24 Volts starting equipment comprising of the following fittings (i)12/24 V Battery (ii)Battery charging alternator (iii) Self starting of suitable capacity (iv) Battery leads of copper cable with brass thimbles and terminals. (v)starting gear engine.
(D) Other fittings (i)Battery charger having electric circuit consisting of triodes , capacitor and resistances etc. The battery charger should be able to charge the battery at all times whenever the electric supply given to battery charger through control panel or electric power point. (ii) In built Fuel tank of suitable capacity as per manufacturers instructions capable for12 hrs running of DG Set inside the canopy base with all connecting pipes upto fuel pump and including oil level indicating gauge drain air vent plug etc. (Note : The rates of this items including foundation as per manufacturer design the commissioning & testing complete (POL for DG Set testing will be issued by MES)
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars of Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The scope of work includes the following:-
(a) Incoming (i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 25 KA rupturing capacity complete with microprocessor based OL protection - 01 No (ii) Voltmeter 0-500 volts, square, 144 mm, digital type, - 01 No (iii) Ammeter size 144 mm, square dial, digital type, - 01 No (iv) LED Indicating lamps : 01 set of three (v) Change over 100A 4 Pole : 01 Nos (vi) Current & Potential Transformer as per manufacturer design : 01 Nos (b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 25 KA rupturing capacity complete with microprocessor based OL protection - 01 Nos. (c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
M/S RATHER CONSTRUCTION CO (BID ID -3457441)
M/S Rather and Sons (BID ID -3465302)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_821596.xls
BOQ • 0.29 MB
Tendermerged.pdf
Tender Documents • 1.80 MB
CompleteDrgMerge.pdf
Additional Documents • 17.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .