Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹48.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 Bidder | |
| 2 | L-2₹50.8 L+₹2.3 L (4.82%)Rejected-Finance | L-2 | Rejected-Finance L-2 Bidder | |
| 3 | L-3₹51.0 L+₹2.5 L (5.19%)Rejected-Finance | L-3 | Rejected-Finance L-3 Bidder | |
| 4 | Rejected-Technical 00 BAIKUNTHPUR SIRSA MANPUR BAIKUNTHPUR SIRSA MANPUR GOPALGANJ 841409 GOPALGANJ BIHAR 841409 | GOPALGANJ | BIHAR | 841409 | - | Rejected-Technical Not submitted the proper experience documents as per PQR |
Tender Value
₹48.8 L
EMD Value
₹50,000
Closing Date
27 Feb 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, ETC, Varanasi
Bhikaripur, DLW, Varanasi
CONVERSION OF EXISTING 220KV BT BAY INTO 220KV LINE BAY FOR ACCOMMODATION OF NEW 220KV SARNATH-GAJOKHAR 2ND CIRCUIT AND CONSTRUCTION OF 1 NO. 220KV BT BAY
2021_UPTCL_554598_1
Short Term E-Tender no. 73/2020-21/ETC/VNS
Open Tender
Electrical Works
Item Rate
60 days
220KV SARNATH-GAJOKHAR at 400 KV S/S Sarnath, Vara
Fee/EMD/PAN/GST Registration and experience for execution of work as per specification
2 documents required · 2 mandatory
₹5,900
SE, ETC, Varanasi
₹50,000
26 Jun 2021
12 Feb 2021
27 Feb 2021
12 Feb 2021
27 Feb 2021
20 Feb 2021
180 days
Amount
Conversion of existing 220KV BT Bay into 220KV Line Bay for accommodation of new 220KV Sarnath-Gajokhar 2nd Circuit and Construction of 1 No. 220KV BT Bay alongwith Civil Works for Conversion of existing 220KV BT Bay into 220KV Line Bay at 400KV Sub Station Sarnath, Varanasi, with all Cost of Men, Misc. Consumables, T&Ps, Crane / Hydra, etc. Required for Satisfactory Completion of the Job, as per Technical Specifications & Direction of the Supervising Engineer, as per Details below :
Dismantling of Air Compressor System which includes 4 Set of 20HP / 15kW Air Compressor Motor (CGL & Brown Bouri make), 3 Set of Air Dryer (HBB make), 8 No. Air Receiver Tank, 1 Set Water Pump with Water Tank, 2 No. Control Panel with accessories, Starter, fuse set etc., Approx. 2200 RMT Copper Pipe laid in Trench of 400KV & 220KV Switchyard and Compressor Room, 4 No. Pressure Reducer Panels and Switchyard lighting MCB Board System by opening of power cable. The above works includes Cutting of Copper pipes into appropriate pieces as per instruction of Supervising engineer and Shifting of dismantled materials from working site to safe storage place safely as per direction of supervising engineer. Erection & grouting of 1 No. Cubicle (Provided by the Department) with first class Brick Ballast, cement & sand mixture in the ratio of 1:4:8, Shifting of dismantled Switchyard lighting MCB Board System with power cable in above Cubicle, termination power cable in cubicle and making proper arrangement for ON / OFF of Switchyard lighting.
Dismantling of 220KV Lattice Type Main & Auxiliary Structure consisting of Column, Beam, Peak, Mast etc. The job consists of shifting of all material from working site to safe storage place as per direction of supervising engineer.
Erection of 220KV Lattice Type Main Structure consisting of Column, Beam, Peak, Mast etc. The job consist of shifting of all material from store to site of erection, erection of structure as per drawing with the help of G.I. Nuts & Bolts, flat & spring washer, matching the hole, proper tightening of Nuts & Bolts, Cutting & matching of member if required.
Erection of 220KV Lattice Type Auxiliary Structures including Shifting, Loading and Unloading along with complete accessories from the Stores to the Erection site.
Making hole in Auxiliary Structures / Main Structures of 220KV side as per site requirement by Gas Cutter & Grinding Machine.
Dismantling of 245KV CT with Junction Box installed in existing 220KV BT Bay along with opening of Control Cables of 220KV CT from both sides and taking out it from Cable Trench and shifting of the above dismantled material from working site to safe storage place as per direction of supervising engineer.
Dismantling of 245KV Standard Isolator including Shifting from site to safe Storage Place in the Sub Station.
Opening of existing of Jumpers of ACSR Moose Conductors of existing 220KV BT Bay between 220KV CT to Lower Jack Bus and CT to LSI and LSI to 220KV Transfer Bus. The job consists of shifting of all dismantled material from working site to safe storage place as per direction of supervising engineer. (1 Job per Jumper of Moose Conductor)
Opening of existing of Jumpers of ACSR Moose Conductors of existing 220KV Azamgarh Bay between 220KV Main Bus1 to SI, Main Bus2 to TI, SI to TI to CB, LSI to TI to CT, Transfer Bus to TI. The job consists of shifting of all dismantled material from working site to safe storage place as per direction of supervising engineer. (1 Job per Jumper of Moose Conductor)
Opening of existing of Jumpers of ACSR Moose Conductors of existing 220KV 315MVA ICT-1 Bay between LSI to TI to CT, Transfer Bus to TI. The job consists of shifting of all dismantled material from working site to safe storage place as per direction of supervising engineer. (1 Job per Jumper of Moose Conductor)
Single Phase Jumpering / Interconnection of existing 220KV Azamgarh Bay i.e. between 220KV Main Bus1 to SI, Main Bus2 to TI, SI to TI to CB, LSI to TI to CT, Transfer Bus to TI Gantry by Twin Moose conductor and CVT to Gantry and LA to Gantry by Twin Moose Conductors between sections below gantries step by step work including jointing of Moose conductor below the gantries with the help of suitable PG clamps through suspension fitting etc. including Cutting, Bending etc. as per site requirement to complete the Job Satisfactorily. (1 Job per Jumper of Moose Conductor).
Single Phase Jumpering / Interconnection of existing 220KV 315MVA ICT-1 Bay i.e. between LSI to TI to CT, Transfer Bus to TI by Twin Moose Conductors between sections below gantries step by step work including jointing of Moose conductor below the gantries with the help of suitable PG clamps through suspension fitting etc. including Cutting, Bending etc. as per site requirement to complete the Job Satisfactorily. (1 Job per Jumper of Twin Moose Conductor).
De-Stringing & Dismantling of portion of existing 220KV Transfer Bus Bars (28 / 36 Meter Span) of ACSR Moose / Tarantula Conductors including De-hoisting of Disc Insulator Strings & Tension Fittings from Gantry alongwith shifting of the old Conductors & Tension Fittings etc. from working site to safe storage place at the Sub Station. (1 Job for each Phase of each Section of the Bus Bar)
Laying & Stringing of 220KV Transfer Bus Bars (36 / 28 Meter Span) of ACSR Moose / Tarantula Conductors including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith Shifting of the Conductor / Materials (to be Provided by Department as per Requirement) from Storage Place at the Sub Station to Erection Site as per details below :
De-Stringing & Dismantling of portion of existing 220KV 3f Main Bus Bars (28 Meter Span) of Twin ACSR Moose Conductor of Approx. 28 Meter Length including De-hoisting of Disc Insulator Strings & Tension Fittings from Gantry alongwith shifting of the old Conductors & Tension Fittings etc. from working site to safe storage place at the Sub Station. (1 Job for each Phase of each Section of the Bus Bar) (1 Job for each Phase of Bus Bar).
Laying & Stringing of 220KV 3f Main Bus Bars (46 Meter Span) of Twin ACSR Moose Conductor of Approx. 46 Meter Length including Hoisting of Disc Insulator Strings, Tension Fittings etc. alongwith Shifting of the Conductor / Materials (to be Provided by Department as per Requirement) from Storage Place at the Sub Station to Erection Site as per details below :
Dismantling of 2 No. Spare C&R Panel for accommodation of new 220KV DPP by opening of all Control cables safely.
Erection of following Equipments (to be Provided by Department as per Requirement) including their Shifting from Storage Place at the Sub Station to Erection Site :
Erection of 245KV SF6 Circuit Breaker.
Erection of 245KV Current Transformer with Junction Box.
Erection of 245KV Current Voltage Transformer with Junction Box.
Erection of 245KV Standard Isolator with 1 ES / 2 ES
Erection of 245KV Tandem Isolator.
Erection of 245KV Post Insulator.
Erection of 198KV Lighting Arrestor.
220KV Line Control Panel and Distance Protection Panel
Single Phase Jumpering / Interconnection of 220KV Bay equipments of new 220KV Line Bay (Old 220KV TBC Bay) i.e. 220KV Jack Bus to Standard Isolator, Standard Isolator to Tandem Isolator, Tandem Isolator to CT, CT to Gantry by Twin Moose conductor and CVT to Gantry and LA to Gantry by Twin Moose Conductors between sections below gantries step by step work including jointing of Moose conductor below the gantries with the help of suitable PG clamps through suspension fitting etc. including Cutting, Bending etc. as per site requirement to complete the Job Satisfactorily. (1 Job per Jumper of Twin Moose Conductor)
Hoisting of 220KV Pilot String Pilot String under Beam to pass the Twin Jumper including Hanging of Disc Insulators and Twin suspension fitting to complete the Job Satisfactorily. (1 Job per Pilot String)
Single Phase Jumpering / Interconnection of 220KV Bay equipments of new 220KV TBC Bay i.e. 220KV MB1 to SI, SI to TI, MB2 to TI, TI to CB, CB to BPI, BPI to TI/SI and TI/SI to 220KV Transfer Bus by Twin Moose Conductors between sections below gantries step by step work including jointing of Moose conductor below the gantries with the help of suitable PG clamps through suspension fitting etc. including Cutting, Bending etc. as per site requirement to complete the Job Satisfactorily. (1 Job per Jumper of Twin Moose Conductor)
Laying of following size Armoured Control Cable in Control & Relay Panel in Control Room and various equipment such as BMK, C.T., J.B. etc. in switch yard making the hole of proper size fixing of glands and providing of ferrules and then wiring the same as per drawing, including dressing of control cable and numbering on cables.
Termination of above Laid Control Cables as per Schematic Drawing & Cable Schedule including proper Ferruling, Dressing, Tying and Tagging of Cables. (Both ends Termination of Control Cable will be considered as 1 No.)
Earthing of Main & Auxiliary Structures, Equipments, Cable Racks with suitable size M.S. Flat, alongwith Excavation of Earth, Cutting, Laying, Bending & Welding and Painting inside ground below 700mm for 220KV C.T., C.V.T., C.B., L.A., Standard Isolators, Tandem Isolators, BPI etc. including earthing with Main Earth Mat and with Object to be Earthed, backl filling of Soil to completing the Job satisfactorily, as per Details below :
Laying of MS Flat of size 75 mm x 10 mm
Laying of MS Flat of size 50 mm x 6 mm
Earthing of Grounded Cable racks in the existing cable trenches of 220KV Bay. The work covers earthing of angle Iron Cable Rack by means of 25 mm x 6 mm M.S. flat including Cutting, Straightening, Laying & Welding on Racks, which will run continuous on each and every Bottom, Top & Middle Rack of Trench and it should be connected at distance of every 750 mm on the continuous running Bottom MS Flat.
Connection of Cable Racks with earth mat at every interval of 30 Meter distance by means of 25 mm x 6 mm M.S. flat after soil excavation (700mm below ground) by due Cutting, Bending, Laying and Welding at Round Bars inside ground and Cable Rack to be earthed, then back filling of soil.
Delta earthing of L.A. consisting of fabrication of delta set with 3 No. 40 mm / 36 mm dia size 1.5 Mtrs. Long electrodes its placing inside the ground and connecting all the three electrodes with 75 mm x 10 mm M.S flat 700 mm deep and connecting the same with earthmat at two places (M.S flat and M.S rod arrange by the Department).
Painting of following sizes M.S. Earthing Strips by Rubbing with Sand Paper & Wire Brush, then Painting with 1 coat of Red Oxide Primer & 2 coats (The 2nd coat of Paint shall be applied at the gap of 48 hrs. when 1st coat of Paint is done & Checked by concerned A.E. / J.E.) of 1st quality Synthetic Enamel Paint of Asian / Berger / Nerolac make in Bus Green Colour :
75 × 10 mm size M.S. Earthing Strip.
50 × 6 mm size M.S. Earthing Strip.
25 × 6 mm / 25 × 5 mm size M.S. Earthing Strip.
Complete Cleaning of 220KV Side Single String Disc Insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men, T&P consumables etc.
Loading, Carriage and unloading of Galvanized Sub Station Structure from EFU, Naini (Allahabad) / Designated Place to 400KV Sub Station Sarnath, Varanasi.
Sorting, Weighing and Loading of Galvanized Sub Station Structures on private Truck to be arranged by the Contractor at EFU Naini, Allahabad / Designated Place.
Safe Transportation of Galvanized Sub Station Structures by Private Truck arranged by the Contractor from EFU Naini, Allahabad / Designated Place to 400KV Sub Station Sarnath, Varanasi (150 - 200 Km. approx.) including Toll charges.
Unloading, Sorting & proper Stacking of Galvanized Sub Station Structures from Private Truck arranged by the Contractor at store yard 400KV Sub Station Sarnath, Varanasi.
Construction of Fire Huts of size 3000 x 2400 x 2400 mm duly made of G.I. / M.S. Angle Post Support & Frame Structure, covered by Asbestos Corrugated (A.C.) Roofing Sheet and B.C. Platform as per technical specifications, with all cost of men, materials, misc. consumables and T&P etc. required for the job, as per details given below :
Grouting of 4 No. 65 x 65 x 6 mm G.I. / M.S. Angle Posts of size 3000 mm after due fabrication with C.C. mixture in the ratio of 1:2:4; Fixing & welding of open Hut type G.I. / M.S. Angle Frame Structure of size 3000 x 2400 x 2400 mm by due fabrication with 65 x 65 x 6 mm size & 50 x 50 x 5 mm size G.I. / M.S. Angles on above grouted G.I. / M.S. Angle Posts by due cutting, drilling, welding etc. of G.I. / M.S. Angles to be provided by Department for each Fire Hut.
Fixing & fitting of Asbestos Corrugated (A.C.) Roofing Sheets of size 3’ x 4’ to cover the Roof of open Hut type G.I. / M.S. Angle Frame Structure of size 3000 x 2400 x 2400 mm with ‘J’ Hook Bolt, Nut and Washer etc. for each Fire Hut.
Construction of B.C. Floor / Platform of size 3.60 x 3.00 x 0.20 M for each Fire Hut with first class Brick Ballast, cement & sand mixture in the ratio of 1:4:8 and finally, 12 mm thick plastering with cement & sand mixture in the ratio of 1:4.
Fixing of 2 No. M.S. B.P. Sheet Board of size 300 x 150 mm in the Angle Frame Structure of each Fire Hut after due fabrication by cutting, drilling, welding etc. of M.S. B.P. Sheet.
Painting of above Angle Post & Frame Structures with Post Office Red colour synthetic enamel Paint of 1st quality in 2 coats after applying 1 coat of Red Oxide Primer and finally, writing ^vkx* and ‘FIRE’ on the M.S. Sheet Boards for each Fire Hut.
Erection of BMK of size 1500 mm x 800mm x 300mm by grouting it in existing 220KV BT Bay, Opening of Control Cables of 1 No. 220KV C.B., 2 No. BSI & 1 No. LSI of existing 220KV BT Bay and fixing of the same in above BMK.
Supply of Bolted type single tension fitting for Twin Moose bundle conductor without turn buckle for 220KV Main Bus comprising with D-shackle, Socket, Ball Link, Yoke plate, D-clip and 250 mm spacing for each disc string comprising 1x16 No. 120 KN disc with hardware set as per technical specification.
Bolted type single tension fitting for Single Moose bundle conductor without turn buckle for 220KV Transfer Bus Comprising with D-shackle, Socket, Ball Link, Yoke plate, D-clip and 250 mm spacing for each disc string comprising 1x16 No. 120 KN disc with hardware set as per technical specification.
Supply of Bolted type single suspension fitting for Twin Moose conductor comprising with D-shackle, Socket, Ball Link, suitable for each disc string 1x16 No. 120 KN disc insulators complete with hardware fitting set as per technical specification.
Supply of 4 Bolted type PG clamp suitable for Moose to Moose conductor complete with HDG nut bolt & washer as per technical specification.
Supply of Bimetallic 220KV Bus Isolator clamp made of aluminium alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification.
Supply of Bimetallic 220KV Tandem Isolator clamp made of aluminium alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification.
Supply of Bimetallic 220KV Tandem Isolator clamp with riser made of aluminium alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification.
Supply of Bimetallic 220KV Line Isolator clamp made of aluminium alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification.
Supply of Bimetallic 220KV Circuit Breaker clamp made of aluminium alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification.
Supply of Bimetallic 220KV CT clamp made of aluminium alloy LM-6 for Twin Moose conductor with HDG nuts & bolts and washer as per technical specification.
Supply of Bus Post clamp (220KV) suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts & washer as per technical specification.
Supply of Spacer for Twin Moose conductor for 250mm spacing for 220KV system complete with hot dip galvanized nut bolt & washer as per technical specification.
Supply of Bimetallic 220KV LA clamp made of aluminium alloy LM-6 for Single Moose Conductor with HDG nut & bolts and washer as per Technical specification.
Supply of 40 mm M.S. Round Bar alongwith Carriage of the same from designated place to 400KV S/S Sarnath, Varanasi.
Supply of MS Flat of following Sizes alongwith Carriage of the same from designated place to 400KV S/S Sarnath, Varanasi :
Supply of 250 Watt LED Flood Light Luminary Fitting (CCT : 5700 – 6500K, CRI>70, Rated Voltage : 220V-240V AC, PF>0.9), Epoxy powder coated pressure die casted aluminum housing with bright anodized aluminum reflector and enclosed with Heat Resistant toughened Glass for Protection with 5KV Surge Protection with Constant current driver suitable for 140-280 VAC working range including bracket mounting and IP66 Degree of Protection applicable for Large Area Lighting of Halonix / Havells / Syska make Complete in all Respect with Electrical Connections. Original Warranty / Guarantee Card should also be submitted along with above material.
Providing & Fixing of 150 Watt LED Street Light Luminary Fitting (CCT : 5700 – 6500K, CRI>70, Rated Voltage : 220V-240V AC, PF>0.9), Epoxy powder coated pressure die casted aluminum housing with bright anodized aluminum reflector and enclosed with Heat Resistant and toughened Glass front visior for Protection with 5KV Surge Protection with Constant current driver suitable for 140-280 VAC working range including Pole side mounting suitable upto 60mm OD pipe and IP66 Degree of Protection of Halonix / Havells / Syska make Complete in all Respect with Electrical Connections, on Periphery Lighting Poles / Gantry already Installed in Switchyard of 400KV S/S Sarnath, Varanasi alongwith other associated Works including Cable Terminations, with all Cost of Men, Materials, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications & Direction of the Supervising Engineer. Original Warranty / Guarantee Card should also be submitted along with above material. (1 Job per LED Street Light Fitting)
Dismantling of foundation (220KV Column RTG) of existing 220KV BT Bay.
Construction of foundation of 220KV Column ETM/RTE/ETR in place of above dismantled Gantry.
Construction of foundation of 220KV CT.
Construction of foundation of 220KV CVT.
Construction of foundation of 220KV LA.
Construction of foundation of 220KV BPI.
Construction of foundation of 220KV Tandem Isolator.
Construction of foundation of 220KV Standard Isolator.
Gupta Elect and Engg Works
M/S JAI SHREE ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .