| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.8 L+₹1.4 L (5.13%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹28.2 L+₹1.8 L (6.83%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.4 L+₹9.0 L (34.0%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹41.6 L+₹15.2 L (57.4%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Dec 2021, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR MAINT OF LT PANELS AND ALLIED WORKS IN DOMESTIC AREA AT AFS KANPUR
2021_MES_489587_1
8540/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹60,000
Yes
31 Dec 2021
22 Nov 2021
25 Dec 2021
22 Nov 2021
20 Dec 2021
7 Dec 2021
Amount
S&F in replacement of MCCB 630 Amps 36 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers, etc. testing and commissioning complete including dismantling of old unserviceable MCCB complete all as specified and directed. Make MCCB :- Legrand / ABB / L&T / Schneider
All as per Item No. 1 above but MCCB of capacity 400 Amps 36 KA, 4 Pole, 415V complete all as specified and directed.
All as per Item No. 1 above but MCCB of capacity 250 Amps 36 KA, 4 Pole, 415V complete all as specified and directed.
All as per Item No. 1 above but MCCB of capacity 200 Amps 36 KA, 4 Pole, 415V complete all as specified and directed.
All as per Item No. 1 above but MCCB of capacity 160 Amps 25 KA, 4 Pole, 415V complete all as specified and directed.
All as per Item No. 1 above but MCCB of capacity 125 Amps 25 KA, 4 Pole, 415V complete all as specified and directed.
All as per Item No. 1 above but MCCB of capacity 100 Amps 25 KA, 4 Pole, 415V complete all as specified and directed.
All as per Item No. 1 above but MCCB of capacity 63 Amps 25 KA, 4 Pole, 415V complete all as specified and directed.
M&L for cleaning and servicing of ACBs of capacity 630-800 Amps, 50 KA, 4 Pole, 415V and other lugs accessories including nuts, bolts, washers etc. testing and commissioning complete all as specified and directed.
All as per Item No. 9 above but of capacity 1000 -1600 Amps, 50 KA, 415V, 4 Pole complete all as specified and directed..
All as per Item No. 9 above but of capacity 2000 -2500 Amps, 50/60 KA, 415V, 4 Pole complete all as specified and directed..
S&F in replacement of ACB 2000 Amps 50 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers etc. testing and commissioning including dismantling of old unserviceable ACB complete all as specified and directed. Make of ACB :- L&T / Legrand / ABB / Siemens / Schneider
All as per Item No. 12.00 above but ACB of capacity 1600 Amps complete all as specified and directed.
All as per Item No. 12.00 above but ACB of capacity 1250 Amps complete all as specified and directed.
All as per Item No. 12.00 above but ACB of capacity 800 Amps complete all as specified and directed.
M&L in replacement of Digital ammeter flush type 96 sqmm with suitable fixing arrangement and including suitable size of copper wound CTs for easily fixing in existing LT panel including necessary wiring complete all as specified and directed. Make : AE / L&T / Schneider
M&L in replacement of Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed. Make : AE / L&T / Schneider
M&L in replacement of Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring complete all as specified and directed. Make : AE / L&T / Schneider
M&L in replacement of CTs (current transformer) 250/400/630 Amps indoor/outdoor type for existing LT panel complete all as specified and directed. Make : AE / L&T / Schneider
Repair / Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth and neutral voltage, removal of foreign objects, replacement of u/s nuts / bolts / washers including replacement of corroded glands, lugs, thimbles, hinges, doors locks, door knobs, gaskets etc. and tightening them properly complete all as specified and directed.
S&F in replacement of aluminium bus bar as per existing size, type and suitable for LT panel 415 Volt, AC including existing size / type insulator , proper taping / sleeving of bus bar and all accessories incl. nut, bolts, washers etc. complete all as specified and as directed.
S&F in replacement of On Load Change Over on wall / Panel 415 Volts 400 Amps capacity, 4 pole with sheet steel enclosure complete all as specified and directed. Make - L&T / Havells / Schneider / ABB
All as per item No. 22.00 above but of capacity 200 Amps complete all as specified and directed.
All as per item No. 22.00 above but of capacity 100 Amps complete all as specified and directed.
M&L for testing of old earthing using calibrated earth tester & submitting result to Engr-in-charge. Earthing that shows on higher side results as specified in IS rule and do not show continuity should be replaced with new earthing. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day prior to the testing & the cost of the same shall deemed to be included in unit rate quoted.
M&L for providing the MS plate size of size 200mmx150 mm of rectangular shape and not less than 1.6 mm thick fixed on angle iron 25x3 mm and 600mm height welded with plate and grouting vertically alongwith earthing pit with PCC block not less than 300mmx300mmx300 mm duly painted background with black colour and writing with white colour Earthing Result in Ohm, date of testing, due date for testing complete all as specified and directed.
M&L for earthing complete (in replacement) with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 m below the ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI strip 32mm x 6 mm size as earthing lead protected with 50 mm dia GI pipe light grade filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C1. using 20 mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm center to center both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing complete all as specified and directed. Note:- Rate for GI strip upto 7.5 m length is included in unit quoted rate and beyond this lengths the same shall be measured and paid separately.
M&L in replacement of GI strip 32mm x 6 mm by taking down the old existing earth strip any size inside hanger, fixing with proper clamp, saddles, nut bolts , washers etc. properly and connected to equipment or panel complete all as specified and directed.
M&L for removing old paint from the LT panels / Feeder Box / Pole by paint removers, cleaning by scrapping and preparing the surface and applying two coats of synthetic enameled paint of existing colour over a coat of red oxide primer using spraying machine and writing any description for panels/ feeder box/ pole complete all as specified and directed.
M&L in replacement of End joint kit Heat shrinkable type suitable for 1100V XLPE under ground cable of size 70-150 sqmm 3.5 core Indoor/Outdoor type complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 30.00 above but of size 185-240 sqmm 3.5 core complete all as specified and directed.
All as per item No. 30.00 above but of size 300-400 sqmm 3.5 core complete all as specified and directed.
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 m outside the periphery of area complete all as specified and directed.
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of any items complete all as specified and directed.
M&L for re-routing of LT cables of sizes from 16 sqmm to 400 sqmm, 3.5/4 core including taking down in ducts/wall/floor/roof/trusses etc and re-alignment of LT cable, cutting/chassing in wall/duct and re-fixing in concealed position as per site requirment, including replacement of luggs, nut, bolts, washers, saddle clamp etc, including making good the disturbed surface to match with the existing surface complete all as specified and directed.
Excavation in trenches by mechanical means, not exceeding 1.50 m wide and not exceeding 1.50 m in depth for laying of cable for soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M&L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, class HV type 1, flat, size 300mmx180mmx40mm complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for cutting of PCC / Hard standing / WBM road not exceeding 30 cm in width & not exceeding 90 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material upto 15 cm in depth and 15 cm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate complete all as specified and directed .
M&L for making horizontal boring 90 cm deep below road crossing for passing of HT cable in GI pipe complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall in replacement GI pipe light grade of size 100 mm bore with fittings for protection of cable including dismantling existing old unserviceable pipe complete all as specified and directed. Make :- Jindal / Tata / Prakash Surya
Taking out from trenches/duct/floor/wall/roof/under road/drain or hardstanding etc. old existing underground XLPE aluminium conductor HT cable of size upto 240 sqmm 3 core for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed.
Supply, laying, testing and commissioning (in replacement) of HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 sq mm 3 core laid in trenches/duct / laid on wall etc. including suitable size lugs , thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells / Polycab / Finolex / Gloster
All as per item No 45.00 above but of size 185 Sqmm 3 core complete all as specified and directed.
Detection of fault through fault locating high voltage mobile machine to locate the fault in underground HT / LT cable by giving high voltage surge and to find out exact location of fault all as directed at site. (Note : The Item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Bidder must quote rate considering the fact that it is solely his responsibility to arrange fault locating machine & he should'nt expect facilitation from the dept. for the same.)
M&L in replacement of straight through joint kit Heat shrinkable type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core all including testing complete all as specified and directed. Make: Raychem / 3M / Denson
M&L in replacement of End termination joint kit Heat shrinkable Indoor type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core including testing complete all as specified and directed. Make: Raychem / 3M / Denson
Taking out, shifting and reinstalling of LT switchgears/ LT Panel/ Pole/ DG Set to a distance not more than 5 KM from power house/ substation/ any place complete all as directed. Taking out, shifting, reinstalling and connecting including casting of suitable PCC foundation etc as per the requirement at site complete all as directed.
M&L for supply, installation, commissioning and testing of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement, IP 54 protection, danger board plate, MFM, phase indicator 03 Nos, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as directed of suitable sizes for following :- Incoming / Outgoing: MCCB 250 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu Make of MCCB - L&T / Legrand / Schneider / ABB
Supply, installation, commissioning and testing of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & neutral, IP 54 protection, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Nos, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as directed of suitable sizes for following :- (a) Incoming : (i) MCCB 400 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 100 Amp, 25kA, 4P, 415V - 03 Nos, Ics=100% Icu (ii) MCCB 63 Amp, 25kA, 4P, 415V - 02 Nos, Ics=100% Icu Make of MCCB - L&T / Legrand / Schneider / ABB
Supply, installation, commissioning and testing of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 240 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement with danger board plate, IP 54 protection, MFM, phase indicator 03 Nos, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as directed of suitable sizes for following :- (a) Incoming : (i) MCCB 160 Amp, 25kA, 4P, 415V - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 63 Amp, 25kA, 4P, 415V - 05 Nos, Ics=100% Icu Make MCCB - L&T / Legrand / Schneider / ABB
Supply, installation, commissioning and testing of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, IP 54 protection, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Nos, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as directed of suitable sizes for following :- (a) Incoming : (i) MCCB 250 Amp, 36kA, 415V, 4P - 01 No , Ics=100% Icu (b) Outgoing : (i) MCCB 100 Amp, 25kA, 4P, 415V - 03 No , Ics=100% Icu Make of MCCB - L&T / Legrand / Schneider / ABB
Attending breakdown attributable to cable faults, flashover in panels or any of the connected transmission system & rectifying it in cable transmission line network upto end connections with panels or any of electrical item connected therein at Air Force station, Chakeri during any hours of a day during the currency of contract by engaging sufficient manpower after receiving communication through Complaint Section / concerned JE / Engr-in-charge either through teleponic call, text message, email or through messanger 24x7 Hrs. Note:- The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 02 hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= per day shall be recovered from contractor's payment. Contractor shall be bound to arrange his resources & all necessary T&P accordingly.
VEE KAY ENTERPRISES
PAWAN COOL CORPORATION
Bharat Sales Corporation
U K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .