Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.2 L+₹1.3 L (18.0%)Rejected-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.4 L+₹2.4 L (34.2%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹10.9 L+₹3.9 L (55.4%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹14.7 L+₹7.7 L (110.3%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L5 | Rejected-Finance L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 May 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR MAINT DG SETS OF ANY CAPACITY BATTERY INCL MISC SPARES PARTS AT AF STN DADRI
2021_MES_439871_1
GE (FBD)/AF-14/2021-2022
Open Tender
Civil Works
Item Rate
180 days
AF STATION DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹30,000
Yes
7 Jul 2021
4 May 2021
26 May 2021
4 May 2021
24 May 2021
11 May 2021
5 May 2021 - 10 May 2021
Amount
Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by descaling solution and using air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer , leak check and pressure testing including transporting to repair workshop and bringing back for upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator up to 75 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator above 160 KVA and upto 160 KVA DG set complete all as specified and directed by Engineer-in-Charge.
Removal & replacement of Old unserviceable flywheel gear ring suitable for upto 160 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
Removal & replacement of Old unserviceable flexible coupling suitable for upto 160 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
Removal & replacement of thermostat suitable for upto 160 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of copper terminal end suitable for batteries of capacity 12V 180AH complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of AVR for DG set having capacity 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of AVR for DG set having capacity 62.5 KVA all as directed by Engr- in-Charge.
Supply and fixing in repair of AVR for DG set having capacity 75 KVA all as directed by Engr- in-Charge.
Supply and fixing in repair of AVR for DG set having capacity upto 30 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair for all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 75 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair for all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 160 KVA any make as per existing complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as specified and directed by Engineer-in-Charge. (a) Battary Charger 12V DC, 5 Amp.
All item as per item No 14 but Battary Charger 24V DC, 10 Amp complete all as specified and directed by Engineer-in-Charge.
Supply only distiled water for top up in Batteries complete all as specified and directed by Engineer-in-Charge.
Supply only electrolyte battery solution (Dilute sulphuric acid have specific gravity 1210 degree) in 10 litrs sealed gallon packing complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of DC 24V Self Solenoid Coil suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of DC 12V Stop Solenoid suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of Bty 12 Volt 80 AH suitable DG set complete all as specified and directed by Engineer-in-Charge. Make - Exide
M&L for repairing of self starter of DG set including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed by Engineer-in-Charge. (a) 12 Volts make - Lucas
All as per item No 21 but 24 Volts make - Lucas complete all as specified and directed by Engineer-in-Charge.
S&F Copper Battery leds suitable for Bty 12V complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 160 KVA of any make as per existing on site complete all as specified and directed by Engineer-in-Charge.
General Servicing of 62.5 KVA of DG sets Make- Ashok Leyond, at run of 500 hours or 5 months which ever comes first (twice in Contract period based on condition ) comprising of following jobs i/c Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed by Engineer-in-Charge. (i) Cleaning & greasing of the parts. (ii) Tappet setting as per standard (iii) Fan belt, tensioner pulley and lever adjustments. (iv) Tightening of all the nuts, bolts and clamps. (v) Testing & checking of AC & DC Wiring. (vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal. (vii) Checking of Supply & return fuel pipes from fuel tank to engine. (viii) Checking of FIP timing by Fuel cut off method.
All as Item No 25 Above but DG set 75 KVA complete all as specified and directed by Engineer-in-Charge.
All as Item No 25 Above but DG set 160 KVA complete all as specified and directed by Engineer-in-Charge.
All as Item No 25 Above but DG set upto 50 KVA complete all as specified and directed by Engineer-in-Charge.
Supply only filling Premixed coolent complete all as specified and directed by Engineer-in-Charge.
Supply only diesel filter suitable for followling capacity of DG set 62.5 KVA to 75 KVA Primery & secondary set complete all as specified and directed by Engineer-in-Charge.
All as per item No 30 but capacity 160 KVA primary and secondary set complete all as specified and directed by Engineer-in-Charge.
All as per item No 30 but capacity 20 KVA to 30 KVA Primery & secondary set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for followling capacities of DG sets 62.5 KVA and upto 160 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No 33 but capacity 20 KVA and upto 30 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair / replace of Air cleaner elements inner and outer for 160 KVA DG sets of cummins complete all as specified and directed by Engineer-in-Charge.
All as per item No 35 but capacity 62.5 KVA & 75 KVA DG sets complete all as specified and directed by Engineer-in-Charge.
All as per item No 35 but capacity 20 KVA to 30 KVA DG sets complete all as specified and directed by Engineer-in-Charge.
Supply and filling in sump/topping up engine oil, multi grade 20w40 in engine or relpacement of engine oil complete all as specified and directed by Engineer-in-Charge. Make :- Indian oil / Hindusthan petrolium / Castrol / Pride /Servo
Opening of AMF Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of above u/s parts and testing on completion of job on existing load etc complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of Bty 12 Volt 180 AH suitable DG set complete all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of crank shaft of DG set having capacity 62 KVA of complete all as specified and directed by Engineer-in-Charge.
Checking, Removal of Faults, Re-wiring & Testing by giving smoke to detector & working of RI & Hooter of Automatic Fire Detection & Alarm System installed in tech area and submitt the serviceability report duly signed by user complete as reqd and as specified & directed by Engineer-in-Charge.
Supply and fixing in repair of 12 Volt 7AH capicity Battery suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Charging Card suitable for Autocut Battery Charger complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Complete Main Control Card (Mother Card) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Control Card suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Zone Card with complete IC suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Photo Electric Smoke Detector suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Manual Call Point (Pill Box) (Aluminium Body) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Hooter capable to work on 24 DC Volt suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of Response Indicator (RI) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S solar water heater of 100 LPD capacity incl dismantling and removal from staging of tank cold water tank and taking down all connections hot and cold water pipe line connections and electric supply connections and removal of all items from roof top for carrying out repair and servicing and re fixing complete all as specified and as directed by Engr in charge.
M&L for replacement of Gunmetal gate valve with iron wheel head screwed both ends for iron pipe and fixed 25 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Gunmetal gate valve with iron wheel head screwed both ends for iron pipe and fixed 20mm dia complete all as specified and directed by Engineer-in-Charge.
S & F Heating element 3 KW with thermostat for electrical Back up suitable of solar geyser as existing model complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of Microprocessor/Alfa-Numeric Based AMF Controler suitable for AMF Panel of DG Set complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge. Make – Havells/Halonix/Polycab
M&L for taking down/ disconnecting old street light fitting any capacity and deposit to MES yard complete all as specified and directed by Engineer-in-Charge.
M&L for LED energy saving and environmental friendly long life versatile pressure diw cast aluminium IP 66 roadway luminaire with high power LEDs and electronic diver complete set of 45 wattage 6000K, with PF-=>0.95, THD-<=10%, driver should be same make as of LED fitting, with operating range of 140 V to 280 V, isolation of driver facility complete all as specified and directed by Engineer-in-Charge. Make - Havells or equevalent in CG/Halonix/Polycab as per site requirment
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 230 mm x 170mmx105 mm complete with suitable aluminium busbar 4 Nos fixed in side the box Make :- Sintex /Hensel or equivalent model complete all as specified and directed by Engineer-in Charge.
M & L for replacement of cable PVC insulated unarmored for connection 2.5 sqmm x 3 core Copper conductor duly drawn MS conduit 20 mm dia from cut out junction box to street light fittings on poles including PVC flexible pipes complete all as specified and directed by Engineer-in - Charge.
M&L for cross arms (MC 75), bracings, supports, clapms and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat paint complete all as spoecified and directed by Engr-in-Charge.
M&L for replacement of LED FLOOD light fitting powder coated PDC aluminium body with toughened glass visior of 120 wattage 5700K IP 66 all as specified and directed by Engr in charge. Havells/Hallonix/Philips/Jaquar
M&L for replacement of LED FLOOD light fitting powder coated PDC aluminium body with toughened glass visior of 80 wattage 5700K IP 66 all as specified and directed by Engr in charge. Polycab/Havells/Hallonix/Philips/Jaquar
M&L for replacement of LED FLOOD light fitting powder coated PDC aluminium body with toughened glass visior of 60 wattage 5700K IP 66 all as specified and directed by Engr in charge. Polycab/Havells/Hallonix/Philips/Jaquar
M&L for overhauling of battery by disconnecting battery from GI pole and removel of suphation, cleaing of plate and all parts painting of poles Bty box etc with two coats of aluminium silver paints and fill up distil water full as required and testing after reassembling all as directed and specified by Engr in Charge.
Supply and fixing in replacement Bty suitable for Solar light 43 Watt 12 V as per existing specification complete all as specified and directed by Engineer-in-Charge.
Supply, Fixing and testing solar street light LED fitting suitable solar light 43 Watt as per existing specification complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Charge controller/drive circuit suitable for solar light upto 43 Watt as per existing specification complete all as specified and directed by Engineer-in-Charge.
Material and Labour for fixing white boards 5' x 4' with blue letters standard sizes with colour codes as per site details of Line digram / Machine History /Distribution boards complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed by Engineer-in-Charge.
M&L for Chain link MS galvanisd fencing, any size or type complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as specified and directed by Engineer-in-Charge.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 for HT, 25x20cm size complete all as specified and directed by Engineer-in-Charge.
M&L for Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type but gear operated type with bevel gear box and crank handle complete all as specified and directed by Engineer-in-Charge.
KRISHANA ELECTRIC WORKS
M/S Anand Enterprises
airstack india
Singh Associates
GAR CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .