| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.2 L+₹4.0 L (14.5%)Rejected-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹33.2 L+₹6.0 L (21.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical NO 9 AVVAI STREET DR CHARLES NAGAR PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | - | Rejected-Technical Not in possession of requisite catagory | |
| 5 | Rejected-Technical | - | Rejected-Technical No remarks in WLR |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer
REPAIR, MAINT, IMPROVEMENT OF LT EXTERNAL ELECTRIC NETWORK WITH ALLIED WORKS IN DOMESTIC AREA AT AFS THANJAVUR
2023_MES_635158_1
8103/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Thanjavur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer
₹80,000
21 Feb 2024
30 Dec 2023
20 Jan 2024
30 Dec 2023
19 Jan 2024
7 Jan 2024
Amount
Supply and fix in replacement Off load/bypass change over switch 200 amps 415 volts 4 pole 50 Hz in sheet metal with out side handle operated complete all as per C&S cat part No CSCSCF200CO4 or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement Off load/bypass change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal with out side handle operated complete all as per C&S cat part No CSCSCF100CO4 or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement On load change over switch 200 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS200NM4CO or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement On load change over switch 160 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS160NM4CO or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement On load change over switch 125 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS125NM4CO or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement On load change over switch 100 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated completeall as per C&S cat part No CSCS100NM4CO or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 630 amps rupturing capacity 65 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CS630NFMU4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 400 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE3M400ATM4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 320/350 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE3M400ATM4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 250 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE2SX250ATM4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 200 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE2NN250ATM4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 160 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSE2NN250ATM4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 100 amps rupturing capacity 25 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSESMX125FMU4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 63 amps rupturing capacity 25 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSESMX125FMU4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 32 amps rupturing capacity 25 KA for 415 volts Ics = 100% Icu complete all as per C&S cat part No CSESMX125FMU4P or equivalent in ABB/Siemens complete all as specified and as directed.
Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 63 amps wall mounted 8 way complete all as per Havells cat part No IHBC006308 Standard/Anchor complete all as specified and as directed.
Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 100 amps wall mounted 8 way complete all as per Havells cat part No IHBC010008 Standard/Anchor complete all as specified and as directed.
Supply and fix in replacement HRC fuse 630 amps complete all as per C&S cat part No CDFL3 or equivalent in ABB / Siemens complete all as specified and as directed.
Supply and fix in replacement DIN open type fuse bases fixed type 630 amps complete all as per C&S cat part No CDFB3 or equivalent in ABB/Siemens complete all as specified and as directed.
Taking out LT cable of any size from loop or any other situated condition and cleaning/removing of old burnt insulation of LT cable by cutting out the damaged portion and fixing the thimbles any size including wrapping of insulation tape and earth work. Note:- The rate quoted by the contractor shall include the rate for aluminum thimbles excavation, RFR and removal etc.
Supply and fix in replacement insulated Copper busbar mounted on epoxy insulators any size by using 100% copper including nut bolts washers etc complete all as specified and as directed.
Supply and fix in replacement insulated Aluminium busbar mounted on epoxy insulators any size including nut bolts washers etc complete all as specified and as directed.
Taking out hanging doors from LT panels welding the doors in position by using new hinges on MS flats including fixing/welding of new MS flats and scrapping old surface and cleaning smoothly and applied two coats of synthetic enamel paint over a coat of red oxide primer of size not more than 1.5 sqm including fixing of locking arrangement complete all as specified and as directed.
Dismantling taking out air circuit breaker any capacity calibration, servicing and replacement of fixed and movable contact points, NVC coil, auxiliary coils, auxiliary thermal magnetic relays, charge springs and greasing of all movable parts etc complete all as specified and as directed.
S&F MCB, Triple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through jointing kit suitable for 6 to 16 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through jointing kit suitable for 25 to 50 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through jointing kit suitable for 70 to 150 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through jointing kit suitable for 185 to 400 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area for the following with all fixing & connecting accessories including taking down old unserviceable cable complete all as specified and as directed. Note :- (i) The rate quoted by the contractor shall include the rate for cable glands and alumininium thimbles.
10 sqmm 2 core
16 sqmm 2 core.
16 sqmm 4 core.
25 sqmm 3.5 core.
35 sqmm 3.5 core.
50 sqmm 3.5 core.
95 sqmm 3.5 core.
120 sqmm 3.5 core .
150 sqmm 3.5 core.
185 sqmm 3.5 core.
240 sqmm 3.5 core.
300 sqmm 3.5 core.
400 sqmm 3.5 core.
Supply and fixing/laying in replacement steel tubing's galvanized, light grade with all fittings fixing along the electric laving in trench or pole / wall for protection of cable complete all as specified and as directed for the following:-
100 mm bore
80 mm bore
50 mm bore
40 mm bore
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed. Note :- Mechanical excavation is not allowed in this Stn. Hence only manual excavation is allowed and the rate shall be quoted accordingly.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255 1983 and refilling in trenches for cable cushioning complete all as specified and as directed.
Removing surplus soils to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
Laying only for existing cable cover laid in trenches with equal to length of cable across the cable for cable protection all as specified and as directed.
D Subramani & Sons
P S G CONSTRUCTIONS
Bidder Name
BKR Enterprises
D Subramani & Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .