Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹40.4 L+₹1.8 L (4.52%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹41.2 L+₹2.5 L (6.37%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹41.6 L+₹2.9 L (7.57%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected | |
| 5 | L5₹41.8 L+₹3.2 L (8.14%)Rejected-AOC | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
19 Sept 2020, 6:00 pmClosed
Garrison Engineer I Belgaum
Garrison Engineer I Belgaum
PROVISION OF TOILET BLOCK FOR UNARMED COMBAT PIT OF CDO TRG AREA OF HQ JL WING, SPECIAL REPAIRS TO STORM WATER DRAINS AT 115 INF BN TA MAHAR AND PROVISION OF CERTAIN REVENUE AND MINOR WORKS UNDER GE I BELGAUM
2020_MES_372958_1
GE (I)/ BEL/ OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
Belgaum
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer I Belgaum
₹91,000
Yes
10 Oct 2020
28 Aug 2020
21 Sept 2020
29 Aug 2020
19 Sept 2020
29 Aug 2020
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/ dense soil all as specified and as directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth for foundation, etc. and getting out in hard/ dense soil all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth for foundation, etc. and getting out in soft/ loose soil all as specified and directed.
Excavation in post holes n.exc 0.5 cum in hard/ dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface all as specified
Returning filling in with approved excavated soil including spreading levelling, watering and well ramming in layers n. exc. 25 cm thick all as specified and directed.
Removing excavated soil to a distance exc. 50m but n.exc 100m and depositing where directed at a level n. exc. 1.5 m above the starting point in soil all as specified and directed.
M&L for hard core with broken stone or boulders of gauge n.exc 63mm, deposited, spread ,levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces all as specified and directed.
M&L for Moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed.
Demolition of plain cement concrete in foundations/ drains/ dilapidated manhole covers of any description and thickness and in any position (below or above GL) all as specified and directed.
M&L for plain cement concrete type D2 1:4:8 using 40mm graded stone aggregate as in foundation and mass concrete all as specified and directed.
M&L for plain cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in foundation and mass concrete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar or lime cement mortar including all quoins, arches, pillars, etc. but excluding precast concrete articles, in any position below or above ground level all as specified and directed.
M&L for pre-cast cement concrete solid block masonry, exc 10 cm width, blocks cast in PCC 1:3:6, type C0, using 12.5 mm graded stone aggregate and setting in CM 1:6 all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4, type B-0, using 12.5mm graded stone aggregate as in damp proof course to horizontal or vertical surfaces including use of necessary form work all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-1, using 20mm graded stone aggregate as in coping, bed blocks including use of necessary form work all as specified and directed
M&L for plain cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in coping, bed blocks including use of necessary form work all as specified and directed
M&L for plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in surface channels, drains and similar works all as specified and directed.
M&L for extra for forming fair finished drain or channel of 30cm inner girth in cement concrete using extra cement including forms moulds mitred/ stopped end etc. all as specified and directed.
M&L for providing precast cement concrete 1:2:4, type B1, using 20 mm graded stone aggregate as in cover slabs, etc. set in CM 1:6 all as specified and directed.
M&L for providing precast cement concrete 1:2:4, type B1, using 20 mm graded stone aggregate as in kerb stones set in CM 1:6 all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in columns, pillars, piers, posts and struts all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in chajjas all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 (nominal mix), Type B1 using 20mm graded stone aggregate in beams, cantilevers, lintels, lintel bands all as specified and directed.
Supply only approved integral water proofing compound all as specified and as directed.
M&L for use of form work to sides of concrete foundations, column footings, plinth beams and similar works for rough finished flat concrete surfaces, vertical or to batter, all as specified and directed.
M&L for use of form work to sides of pillars, posts, struts, columns, etc. for fair finished concrete surfaces, square, rectangular or polygonal all as specified and directed.
M&L for use of form work to sides and soffits of roof beams, tie beams, lintels, lintel bands and similar works for rough finished flat concrete surfaces all as specified and directed.
M&L for use of form work to sides and soffits of chajjas, flat rough finished surfaces of concrete all as specified and directed.
M&L for use of form work to edges of concrete flats, treads, bands and similar works, for rough finished concrete surfaces, horizontal or sloping, exceeding 10cm but not exceeding 20cm wide all as specified and directed.
M&L for solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet on single side reinforced with M.S. Square tube, supplying and fixing in opening as per specification and drawing all as specified and as directed.
M&L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded prelaminated PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of prelaminated PVC sheets on both sides to be fitted in the M.S. frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing all as specified and directed
M&L for mild steel TMT bars 8mm dia and over cut to length bent to shape required including cranking bending, spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia all as specified and directed.
All as described in item No. 33 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for mild steel hold fast and similar small article conforming to Fe-290 Grade-E-165 all as specified and as directed.
S&F mild steel works in tubular posts, rafters, purlins, etc. including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 all as specified and as directed.
S&F rolled mild steel angle sections as in purlins, distance pieces, cleats and similar works conforming to Fe-410-W Gde-E-250 quality-A including dismantling existing unserviceable mild steel works of any description and size all as specified and as directed.
S&F Steel ventilators with top hung shutters including hinges with steel peg stays, hold fasts, complete all as specified and as directed.
M&L for pre-painted galvalume coated high tensile corrugated/ trapezoidal profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.5mm thick (TCT), as in roofing/ cladding fixed with self drilling fasteners as per manufacturers instructions all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
M&L for pre-painted galvalume coated high tensile plain profile steel sheets, AZ-70 coating mass, 550 Mpa yield strength, 0.5mm thick (TCT), as in ridges, valleys, hips, claddings, etc. fixed with self drilling fasteners as per manufacturers instructions all as specified and as directed. Note: Measurement shall be taken flat as fixed without any allowance for laps, etc.
M&L for 75mm thick plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in sub base/ levelling course for flooring all as specified and directed.
M&L for 50mm thick plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in sub base/ levelling course for flooring all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B0 using 12.5mm graded aggregate as in sub base for flooring all as specified and directed.
M&L for 100mm thick plain cement concrete 1:2:4 type B1 using 20mm graded aggregate as in paving/ flooring including finishing the surface even and fair and making impression of expanded metal while the concrete is green all as specified and directed.
M&L for 50mm thick plain cement concrete 1:2:4 type B1 using 20mm graded aggregate as in paving/ flooring including finishing the surface even and fair and making impression of expanded metal while the concrete is green all as specified and directed.
M&L for coloured non skid ceramic tiles, edge cut, 9 to 10mm thick area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigments to match the shade of the tile laid over and including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for coloured glazed ceramic tiles 350mm X 250mm or 450mm x 300mm, 7mm thick on vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces including 10mm thick backing coat in CM 1:4 all as specified and directed.
M&L for machine cut Kota stone slab, 20-25mm thick, as in flooring, laid and jointed with neat slurry and pointed with grey cement slurry mixed with pigment to match the shade of the slab including bull nosing the edges, rubbing and polishing complete including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L for machine cut Kota stone slab, 20-25mm thick, as in risers of steps, skirting, dado, cladding to pillars, etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including bull nosing the edges, rubbing and polishing complete including 10mm thick backing coat in CM 1:4 all as specified and directed.
M&L for machine cut granite stone slab, premium quality, any colour, 18 to 19mm thick, set and jointed with neat cement slurry laid over and including 15mm thick screed bed in cement mortar 1:6 and pointed in white cement (1:2) mixed with colouring pigments to match with the shade of slab, as in platforms, steps, cills, etc. including rubbing and polishing complete all as specified and directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, with grey cement and pigments, set jointed and pointed in neat cement slurry, laid over and including 15mm thick screed bed in cement mortar 1:6 as in pathways, etc. complete all as specified and directed.
M&L for 80mm thick machine pressed precast concrete interlocking coloured paver blocks with glossy finish on top, M-40 grade, any shape and size with anti skid finish on top confirming to IS 15658-2006 all as specified and directed.
M&L for 55 to 60mm thick machine pressed precast concrete interlocking coloured paver blocks with glossy finish on top, M-35 grade, any shape and size with anti skid finish on top confirming to IS 15658-2006 all as specified and directed.
M&L for river sand, filled under paver block floors as in cushioning including watering and consolidation all as specified and as directed.
M&L for plain cement concrete 1:3:6, type C1, (Using 20 mm graded stone aggregate), 75mm thick as in plinth protection, finishing the surface fair and even, in panels & filling joints with mortar, etc. all as specified and directed.
Taking down cement plaster on brick or stone wall or ceiling concrete etc. including racking out joints hacking for key scrubbing down with water etc., all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement complete all as directed.
M&L for rendering 5mm thick in cement mortar 1: 4 mixed with water proofing compound over 10mm thick backing coat in cement mortar 1:6 on fair faces of brick work or PCC block masonry or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M&L for three coats of white wash on newly plastered walls, pilasters, cornices, etc. including necessary preparation of surfaces all as specified and directed.
M&L for two coats of cement based paint, any colour, over a coat of alkali resistant primer on newly plastered surfaces of walls, pilasters, cornices, etc., including necessary preparation of surfaces all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of new steel surfaces of any description n exc 10 cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for 500 litres capacity rotational moulded polyethylene (HDPE) water storage tanks, 'ISI' marked, cylindrical, vertical with closed top conforming to IS 12701-1989 having two layers wall construction with manhole lid and suitable locking arrangement including making holes for inlet, outlet and over flow pipes, hoisted and fixed in position including provision of 20mm bore ball brass valve and testing complete all as specified and directed.
S&F 15mm bore galvanized iron tubes, medium grade, with all fittings, fixed complete to walls, ceilings or laid in floors all as specified and directed.
S&F 20mm bore galvanized iron tubes, medium grade, with all fittings, fixed complete to walls, ceilings or laid in floors all as specified and directed.
S&F 15 mm bore UPVC water supply pipes, 10kgf/ sqcm, including all fittings such as elbow, reducer, tee, couplers, short pieces, connectors etc. fixed to walls , ceilings with PVC batten holders all as specified and as directed.
S&F 20 mm bore UPVC water supply pipes, 10kgf/ sqcm, including all fittings such as elbow, reducer, tee, couplers, short pieces, connectors etc. fixed to walls , ceilings with PVC batten holders all as specified and as directed.
S&F 15mm bore bib taps, brass CP, fancy type, long body, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.
S&F 15 mm bore 2 way Bib tap, long body, brass chromium plated, fancy type, with crutch or butter-fly handle, screwed down, screwed for iron pipe or for brass ferrule etc all as specified and directed. Make: Cat No. FUS 29041 of JAQUAR or equivalent model in JOHNSON/ CERA
S&F health faucet, brass chromium plated with 1m long flexible PVC tube and wall hook all as specified and as directed. Make: Cat No. ALD-CHR 563 of JAQUAR or equivalent model in JOHNSON/ CERA
S&F 15mm bore stop valves, cast copper alloy, screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions all as specified and as directed.
S&F 15mm bore stop valves, brass CP, fancy type, screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions all as specified and as directed.
S&F pillar taps, brass chromium plated with capstan heads, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed down high pressure screwed for 15mm bore GI pipe all as specified and directed.
S&F vitreous china wash basin, white, size 550x400mm, including CI brackets, waste pipe and fittings and cutting for and pinning in ends of brackets or erecting stands etc. all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including 'P' or 'S' trap, plastic water closet seat of any colour as approved by GE, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, fixing bolts etc, connecting to drain pipe and flushing pipe all as specified and as directed.
S&F Vitreous China urinal, bowl type (back or corner wall type), white,465mm x 355mm x 265mm size including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including provision of grating and union for discharge pipe, 15mm bore brass CP urinal spreader, LDPE waste pipe, flush pipe complete all as specified and as directed.
S&F vitreous china squatting pan, Orissa pattern, size 580mm x 440mm, white, with integral foot rest (excluding flushing cistern) including 'P' or 'S' trap including provision of lime concrete bedding etc complete all as specified and directed.
S&F syphonic action type low level PVC flushing cistern, 10 litres capacity, white, with inlet, ball valve, float, handle and flush pipe etc complete all as specified and directed.
S&F plastic water closet seat for EWC, closed pattern with flat bottom and cover, any colour as approved by GE and mild steel chromium plated or aluminium hinging device all as specified and as directed.
S&F PVC connection 15mm size with PTMT nuts, 450mm long all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts, 600mm long suitable for hot/ cold water supply all as specified and directed.
S&F brass chromium plated tubular towel rail 600mm long with and including Chromium plated brass screws & wooden/ plastic cleats all as specified and as directed.
S&F 110mm bore UPVC (SWR) pipes single socketed in any length with rubber ring/ solvent cement joints fixed to walls/ laid in floors/ trenches all as specified and directed.
S&F 75mm bore UPVC (SWR) pipes single socketed in any length with rubber ring/ solvent cement joints fixed to walls/ laid in floors/ trenches all as specified and directed.
S&F 110mm bore UPVC (SWR) bends any radius all as specified and directed.
S&F 75mm bore UPVC (SWR) bends any radius all as specified and directed.
S&F UPVC PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm dia outlet all as specified and directed.
M&L for 300mm bore Reinforced cement concrete pipes, class NP2, laid and jointed complete with collars all as specified and as directed.
All as described in item No. 92 but 200mm bore RCC pipes
M&L for bed concrete to 300mm bore drain pipes in Plain Cement Concrete 1:4:8 type D2 using 40 mm graded stone aggregate including packing under and completely surrounding pipe after they are laid and tested all as specified and directed.
All as described in item No. 94 but to 200mm bore drain pipes
All as described in item No. 94 but to 110mm bore drain pipes
Cutting into existing manholes for connecting new drain pipes, 110mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required all s specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded cables drawn through and including ISI marked PVC casing capping of suitable size and all necessary fittings and provision of one run of PVC insulated FRLS unsheathed 1100 volt grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including 1/2 module surface mounting flush box with modular cover plate & frames for mounting switches/ sockets etc. for one light point controlled by one modular switch 1 way complete all as specified and directed.
All as described in item No. 98 but for one exhaust fan point controlled by one modular switch.
All as described in item No. 98 but for one 06 Amps modular socket outlet point controlled by one modular switch 1 way on independant board
All as described in item No. 98 but for one 05 Amps socket outlet on the same board with other switches.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 1.5 sqmm drawn through and 1100 volt grade including PVC casing and capping of suitable size with all necessary fittings and provision of one run of 1.5 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly complete all as specified and directed. Note: Two runs of 1.5 sqmm cable, one run of 1.5 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm drawn through and 1100 volt grade including PVC casing and capping of suitable size with all necessary fittings and provision of one run of 4 sqmm PVC insulated FRLS unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly complete all as specified and directed. Note: Two runs of 4 sqmm cable, one run of 4 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
S&F modular switch, 1 module, 1 way, 6 Amps, 230 volts, AC, all as specified and directed.
S&F modular socket outlet, 2 module, 6 Amps 2 cum 3 pin multipurpose all as specified and directed.
S&F ceiling rose 3 terminal suitable for 230 volts AC supply all as specified and directed.
S&F Single pole and neutral enclosure, powder coated, with a two pin earth plug and socket complete, 20 Amps, 240V, including provision of one single pole MCB 20 Amps 'C' curve type all as specified and as directed.
S&F MCB DB SPN 4 Way with 100 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
S&F MCB DB SPN 8 Way with 100 Amps rated bus bars double door type, flush mounted on wall complete all as specified and directed.
S&F MCB DP 40A 10KA 'C' series 50Hz AC supply all as specified and as directed.
S&F MCB SPN 40A 10KA 'C' series 50Hz 240 Volts AC supply all as specified and as directed.
S&F MCB SP 5-32A 10KA 'C' series 50Hz 240 Volts AC supply all as specified and as directed.
S&F surface mounting LED light fitting, 20W, 230V, wall/ ceiling mounted type, with extruded aluminium housing and polycarbonate diffuser, 20W LED strip, integrated driver and all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block and provision of 2 Nos. of PVC square blocks all as specified and directed. Make: HAVELLS LUMILINE PLUS or equivalent in CG/ Philips/ Wipro
S&F 25 Watts LED security light fitting, with pressure die cast aluminium housing and lens embedded PC cover having top opening separate driver compartment with IP65 protection, 25 Watts high power LEDs, electronic driver including all accessories internally pre wired complete and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block including provision of bracket made out of GI pipe light grade of suitable size and length and bent to shape fixed to walls/ poles with suitable MS clamps, bolt, nuts etc. complete all as specified and directed. Make: ENDURA PEARL model of HAVELLS or equivalent in Crompton Greaves/ Philips/ Wipro
S&F wall mounting fan, 230 volts, single phase, 450mm sweep, with all accessories fixed to wall with all necessary brackets, bolts, nuts, etc. including testing and making good disturbed surfaces complete all as specified and as directed. Make: HAVELLS AIRBOLL HI-SPEED or equivalent model in makes CG/ ORIENT
Supplying of pedestal fan, 400mm sweep, single phase, 230 volts, with all accessories including connectng up and testing all as specified and as directed. Make: HAVELLS SPRINT HS or equivalent model in makes CG/ ORIENT
S&F exhaust fan, 300mm sweep, 230/240 Volts, 900 RPM, heavy duty, single phase, metallic body with louvres and fixing arrangements with fixing bolts and provision of 3 core flexible copper conductor cable of size 1.5sqmm size from ceiling rose to connector of exhaust fan and testing all as specified as directed. Make: Havells Turbo Force SP model or equivalent model in Almonard/ Crompton Greaves
S&F storage type water heater (Geyser), vertical type, 50 litres capacity, 2000 Watts, 5 Star rating including drilling holes into wall, provision of 4 Nos of suitable size anchor bolts, nuts and washers, connecting up electrical & water supply lines, testing complete all as specified and as directed. Make: MONZA EC model of HAVELLS or equivalent model in RACOLD/ BAJAJ
M&L for approved riddled earth, spread dry in trenches as in cable cushioning at bottom and top including punning down all as specified and as directed. Note :- Punned thickness will be considered for payment.
M&L for burnt bricks, old size, sub class 'B' of designation 75, laid in trenches as in protection for UG cables all as specified and as directed.
M&L for GI tubes, light grade, 40mm bore, as in cable protection, fixed to poles/ walls with necessary MS clamps, bolts, nuts, washers or laid in trenches / under roads/ crossing etc. all as specified and as directed.
M&L for XLPE insulated, armoured, heavy duty electric LT UG cable with multi-stranded aluminium conductor, 1100 Volts grade, cross sectional area 35Sqmm x 4 core, laid in trenches/ passing through pipe/ duct or fixed to wall including provision of necessary lugs/ thimbles/ ferrules, connecting up, testing and commissioning complete all as specified and as directed. Note: Excavation, earth work, sand cushioning, bricks/ GI pipe for protection shall be measured and paid separately under relevant items of this schedule.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground vertically (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below normal ground level connected to GI wire 4mm dia (7.5m long) by means of GI bolts nuts washers and GI wire protected by 15mm dia light grade GI pipe (7.5m long) and watering arrangements with 20mm dia GI pipe medium grade and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule Part I including necessary excavation and earth work in any type of soil, charcoal, dust salt, PCC 1:2:4 type B1 in chamber, 40mm thick RCC 1:2:4 type B1 in cover slab with 8mm dia TMT bars at 100mm C/C both ways and with 8mm dia MS hook complete and testing all as specified and directed.
M/s. N D KALING
SHRI.H.R.PATIL
SAGAR ENTERPRISES
M/s A N Kalbhavi
DHANSHRI ENTERPRISES
M/S MAHADEV M PATIL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .