| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.1 LAccepted-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | ₹12.1 L Quoted ₹12.5 L | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA |
| 2 | 2₹16.5 L+₹4.0 L (32.4%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | ₹16.5 L+₹4.0 L (32.4%) | 2 | Rejected-Finance NOT BEING LOWEST TENDERER |
| 3 | 3₹17.1 L+₹4.6 L (37.2%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹17.1 L+₹4.6 L (37.2%) | 3 | Rejected-Finance NOT BEING LOWEST TENDERER |
| 4 | 4₹20.6 L+₹8.1 L (64.8%)Rejected-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | ₹20.6 L+₹8.1 L (64.8%) | 4 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Feb 2024, 6:55 pmClosed
GE Chennai
GARRISON ENGINEER FORT SAINT GEORGE CHENNAI - 600009
REPAIR/ MAINTENANCE OF LT PANEL BOARDS/FEEDER PILLAR BOXES, CONTROL PANELS AND CONNECTED ACCESSORIES AT C AND E AREA UNDER GE CHENNAI
2024_MES_635819_1
8721/E8
Open Tender
Civil Works
Item Rate
275 days
GE Chennai
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Chennai
₹40,000
Yes
15 Mar 2024
4 Jan 2024
8 Feb 2024
4 Jan 2024
1 Feb 2024
18 Jan 2024
Amount
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep and getting out complete all as specified and directed.
Returning filling in including spreading, levelling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches all as specified and directed (Punned thickness only shall be measured and paid) complete all as specified and directed.
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges.
Taking out the existing PVC/XLPE, 1100 grade, LT UG electric cable of size 95sqmm x3.5 core trenches/ walls (or) passing through pipes/in floor and removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing complete all as specified and directed. Note:- Excavation and Earth work shall be measured and paid separately under appropriate items:-
All as per item No. 6.00 above but cable size 150 sqmm 3.5 core.
All as per item No. 6.00 above but cable size 185 sqmm 3.5 core.
All as per item No. 6.00 above but cable size 240 sqmm 3.5 core.
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc. connecting with suitable cable lugs/sleeves etc. and size 95 sqmm 3.5 core complete all as specified and directed.
All as per item No. 10.00 above but cable size 150 sqmm 3.5 core.
All as per item No. 10.00 above but cable size 185 sqmm 3.5 core.
All as per item No. 10.00 above but cable size 240 sqmm 3.5 core.
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core complete all as specified and as directed.
All as per item No. 14.00 above but cable size 150 sqmm 3.5 core.
All as per item No. 14.00 above but cable size 185 sqmm 3.5 core.
All as per item No. 14.00 above but cable size 240 sqmm 3.5 core.
M&L cable jointing kit for PVC/XLPE/ LT UG cable jointing straight through heat shrink type joints complete with jointing material and accessories suitable for 95 sqmm 3.5 core cable incl taking down old unserviceable ones complete all as specified and directed.
All as per item No. 18.00 above but for 150 to 185 sqmm 3.5 core cable.
All as per item No. 18.00 above but for 240 to 300 sqmm 3.5 core cable.
Supply and laying GI tube light grade 100mm bore with suitable joints and clamps laid in trenches/ fixed on walls complete including taking down old pipe complete all as specified and directed.
S&F for PCC type B1 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided, complete all as specified and directed.
M&L for painting of 3 coats of white wash on walls/lintels including preperation of new surfaces all as specified and directed.
Dismantling the existing LT Panel board after disconnecting Incoming and outgoing cables with earth connections and moving the dismantled panel board from the site and re-installing the same panel board on the new PCC platform, including connecting the incoming and outgoing cable along with earth wire , testing amd commissioning complete all as directed. Note :- PCC platform and connected works will be measured and paid seperatly under relavent items.
Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of " MES LT Cable " including 30 cm length angle iron support and embedded in and including PCC and taking down old unserviceable ones complete all as specified and directed.
S& F for GI earthing strip 25x4 mm with nut and bolts complete including taking down old one complete all as specified and directed.
S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,buried in ground including excavation and taking down old unserviceable ones complete all as specified and directed.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 2 KVAR including MCCB complete all as specified and directed.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 5 KVAR including MCCB complete all as specified and directed.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 10 KVAR including MCCB complete all as specified and directed.
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. Including taking down the old panel required at site and comprising following:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and conneting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language.
Item No. 31.00 Contd/- Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) S&F Digital Multi Function meter Nos -01 (d ) S&F for MCCB 400 Amp 36 KA 4 pole Thermal magnatic setting complete - N0s -01 Outgoing (a ) S&F MCCB of 4 pole of capacity 100 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 04 Nos (b ) S&F MCCB of 4 pole of capacity 125 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 04 Nos
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. Including taking down the old panel required at site and comprising following:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and conneting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language.
Item No. 32.00 Contd/- Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) S&F Ammeter and voltmeter digital multy meter Nos -01 (d ) S&F for MCCB 350 Amp 36 KA 4 pole Thermal magnatic setting complete - N0s -01 outgoing (a ) S&F MCCB of 4 pole of capacity 63 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 02 Nos (b ) S&F MCCB of 4 pole of capacity 160 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 03 Nos (c ) S&F MCCB of 4 pole of capacity 200 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 03 Nos
Supply , install, testing and commissioning of cubical housing cabinet type LT Junction box of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from front side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.Necessary foundation work as per manufacturer instruction including foundation and including taking down the old panel required at site and comprising following:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and conneting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language.
Item No. 33.00 Contd/- Incoming (a) SS&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 200 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos (b) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (c) S&F Digital Mutlti Function meter Nos -01 (d ) S&F for MCCB 100 Amp 16 KA 3 pole Thermal magnatic setting complete - N0s -01
Repair/maint for LT panel any type and any sice and scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer and black for foundation/bases frame including writing of feeder name complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion complete all as specified and as directed.. Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
M/s.Sai Agency
EVEREST ENGINEERING WORKS
NAVEEN ENTERPRIESES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .