Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC NATIONAL HIGHWAY BYE PASS CROSSING ATHWAJAN SRINAGAR 191101 KASHMIR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | ₹1.5 Cr | 1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | 2₹1.7 Cr+₹24.2 L (16.3%)Rejected-Finance | ₹1.7 Cr+₹24.2 L (16.3%) | 2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | 3₹1.8 Cr+₹35.8 L (24.1%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹1.8 Cr+₹35.8 L (24.1%) | 3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | 4₹1.9 Cr+₹37.5 L (25.3%)Rejected-Finance HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | ₹1.9 Cr+₹37.5 L (25.3%) | 4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | Rejected-Technical | - | - | Rejected-Technical NO IN WLR |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
24 Jul 2021, 6:00 pmClosed
CWE AF SGR
CWE AF SGR
PROVN OF PRE FABRICATED OP SHELTER AT 8FBSU AF AWANTIPUR
2021_MES_424948_2
CWE(AF)SGR/AWA-30/2020-21
Open Tender
Civil Works
Lump-sum
270 days
AF STATION AWANTIPUR
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AF AWANTIPUR
₹2.0 L
Yes
23 Sept 2021
15 Jun 2021
26 Jul 2021
15 Jun 2021
24 Jul 2021
3 Jul 2021
Amount
Sch 'A' Part-I (Septic Tank and Soakage Well) Note: Prepriced at par with SSR 2010 Part I at Serial Page No 23 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part-II (Sewage Disposal) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 25 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part III (Road,Path and Culvert) Note: Prepriced at par with SSR 2010 Part III at Serial Page No 26 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part IV Sec-I (Pre Fabricated LGSF Shelter) Note: Prepriced at par with SSR 2010 Part IV Sec-Iat Serial Page No 35 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part IV Sec-II (Pre Fabricated LGSF Shelter) Note:- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs.0.00" under Col 5 signifies this fact only.
Material and Labour for factory finished, custom designed cold formed light gauge steel frame super structure manufactured out of minimum 0.75mm to 2mm TH Pre-treated, factory finished bare galvalume sheet (AZ150 GSM Aluminum Zinc Alloy coated steel and 550 Mpa yield strength) conforming to AISI specications for cold form steel framing and construction. The framing section shall be cold form, C type, having minimum depth of (89/150mm x 39mm x 11mm) in required length as per structural design requirements duly punched with dimple slots at required locations as per approved drawings. The slots will be along the center line of the web, and shall be placed at a minimum of 250mm away from both edges of the member. The frame can be supplied in panelised or knock down condition, in specific dimension and fastened with designed screws And Connectors (minimum 4 mm dia galvanized wafer head screws) .The frame to be fastened with Design screws extending through the steel beyond by minimum of three exposed threads. All self-drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection,The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings (subject to minimum 12 mm diameter and 121 mm length) conforming to AISI 304 and 316 at 500 mm c/c with minimum embedment of 100 mm in RCC and located not more than 300 mm from corners or termination of bottom tracks complete in all respects.Design Galcanised connectors for to connect member of LGSF In structural manner. Connectors conatains Bracket, Tri-fix, multy fix, Twist Fix strap, Anchor, Braces, fix plate, apex plate, Etc., as in LGSF Assembly and Erection For Ground And First Floor, complete all as specified & directed by Engr-in-Charge.
Material and Labour for GI decking sheet minimum 0.8mm thick in trapezoidal profile having profile depth of 44mm, fix on Flat slab joist with self-drilling/tapping screws/fasteners for trusses and wall frames and purlins conforming to IBC 2009 for cold formed steel framing, as in Deck Sheet Fitting For Ground Floor And First Floor Slab, complete all as specified & directed by Engr-in-Charge.
Material and Labour for M-30 grade (design mix) concrete Thickness of 50mm with GI wire mesh 4 mm thick laying on Deck sheet and require floor finish, as in First Floor Slab Casting, complete all as specified & directed by Engr-in-Charge.
Material and Labour for exterior faces of the frames with breather vapour barrier underneath the cement board, For Ground And First Floor, complete all as specified, shown on drawings & directed by Engr-in-Charge.
Material and Labour for External Wall Cladding (8+8mm thickness) using cement fibre board on wall panels of cold formed galvanized light gauge steel frame structure to form wall/partion on external face of the frame fixed with self-drilling, tapping screws, fasteners of approved make. First LAYER - 8mm layer of external grade cement fiber board conforming to IS 4862:2000 2nd LAYER - 8mm layer of external grade cement Fiber board conforming to IS 4862:2000 Lap Sidings for Elevation purpose as per Arch Drawing, Out Side Cladding Fitting For Ground And First Floor, complete all as specified, shown on drawings & directed by Engr-in-Charge.
Material and Labour for internal Wall Cladding using cement fiber board on wall panels of cold formed galvanized light gauge steel frame structure to form wall/partion on Internal face of the frame fixed with self-drilling, tapping screws, fasteners of approved make. First LAYER - 8 mm layer of internal grade cement fiber board conforming to IS 4862:2000 2nd LAYER - 8mm layer of internal grade cement Fiber board conforming to IS 4862:2000, Inside Cladding Fitting For Ground And First Floor, complete all as specified, shown on drawings & directed by Engr-in-Charge.
Material and Labour for Rock Wool Insulation 50 mm thick mineral wool (density 42kg/m3) insulation to be used as filler between the outer and inner skin of the wall with and including wooden/ PCC spacers Rock Wool Insulation For Ground And First Floor, complete all as specified , shown on drawings & directed by Engr-in-Charge.
Material and Labour for integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS.2645 over the RCC slab including cleaning the surface before treatment. After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645 and laying 3mm thick APP membrance over a coat of bitumen primer, finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with proprietary waterproofing compound conforming to IS:2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square. The whole terrace so finished shall be flooded with water for a minimum period of one weeks for curing and for final test, Toilet/Bath/Wash Water Proofing For Ground And First Floor, complete all as specified & directed by Engr-in-Charge.
Supply and Fixing UPVC window( double track) with following specification, glass 5mm clear tough + 12mm A G + 5mm clear toughened, Profile - Mozart Premium, Colour- White, Drainage- Face, Reinforcment- standard, T-joints- Mechanical/V-welded, Bead- Default, Mesh - Pull down, Handle type- Cocksper handle.
Supply and Fixing for prefabricated PUF insulated 40mm thick panels as in roof sheet with 0.6mm thick PPGI sheet on both faces of PUF panels with tongue and groove syatem with adequate number of cam lcks for better jointed strength and fixing with self tapping screws/all as per menufacturer's instructions and as directed including insulation tapes. the gap PUF panel confirms to IS: 12436, IS: 7888, complete all as specified and directed by Engr-in-charge.
Sch 'A' Part V Sec-I (External Electrification) Note: Prepriced at par with SSR 2010 Part V Sec-I at Serial Page No 38 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part V Sec -II (External Electrification) Note:- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs.0.00" under Col 5 signifies this fact only.
Sch 'A' Part VI Sec -I (External Water Supply) Note: Prepriced at par with SSR 2010 Part VI Sec-I at Serial Page No 41 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part VI Sec -II (External Water Supply) Note:- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs.0.00" under Col 5 signifies this fact only.
Material and labour for construction of valve pit of size 60x 60 x 60 cm internal dimensions with 150 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate as in foundation, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregae) as in coping, plastering 15 mm thick in CM 1:4 including 3 mm thick MS sheet pit frame 40x40x6 mm thick complete with locking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 50 metre distance, complete all as specified and as directed.
Sch 'A' Part VII Sec -I (Internal Electrification) Note: Prepriced at par with SSR 2010 Part VII Sec-I at Serial Page No 47 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part VII Sec -II (Internal Electrification) Note:- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs.0.00" under Col 5 signifies this fact only.
Supply and fixing decorative box type fitting with blue colour end cap for LED tube 20 watt luminaire for 230 volt AC incl LED tube 20 watt complete all as specified & approved by EIC.Make:- C&S cat part No.LTDC01220W LED/WD or equivalent approved by GE
Supply and fixing Energy saving new generation 10 W LED IP 65 bulkhead luminair with opal diffuser with 10 LED lamp etc complete as specified and directed. Make :- C&S Model No CG80IB10WLED or equivalent approved by GE
Supply and fixing mirror light sleek LED mirror light provided with high output diffuser with suitable capacity driver with all comptonants as per manufacturer etc complete as specified and directed Make :- Crompton Cat part No LCL-14-CDL or equivalent approved by GE
Supply and fixing MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incoming & outgoing controlling system of capaicty 32 Amps 10 KA breaking capacity etc all as specified and directed. Make :- Legrand cat part No 408618/20 or equivalent approved by GE
Supply and fixing MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incoming and outgoing controlling circuit of capacity 6-40 Amp breaking capacity 10 KA etc all as specified and directed. Make:- Legrand cat part No 408587 to 408595 or equivalent approved by GE
Supply and fixing heavy duty exhuast fan 300mm sweep,1400 RPM turbo force model single phase, 240 volts with louver of MS/Aluminum body separately including fixing of the same and all accessories as per manufacturer norms with 3 core flexible cable from ceiling rose to connector of fitting etc complete as specified and directed Make :- Havells/sudhir/Anchor
Supply and fixing storage type water heater 5 star rated,50 ltrs capacity vertical wall mounting type made out of CRCA outer body, stainless steel storage tank, titanium enamelled heating element, thermostate, thermal cutout, glass wool including 15mm, 450 mm long (cold water pipe) with copper crutch and 15mm 450 mm long armourd pipe (hot water pipe ) etc. complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper (multistranded) cable with top indicator plug top 15 amp from geyser connnection to socket including hold fast for fixing of new geyser and writing the MES No complete all as specified and directed . Make :- Havells (Monza turbo)/Racold/Jaguar
Supply and fixing wall fan 400 mm sweep with all accessories as per manufacturer norms etc complete as specified and directed. Make :- Havells (Platina HS) /Usha/Khetan
Supply and fixing wall mounted bus bar chamber enclosed complete with bus bar capacity of 315 Amp 04 Nos, 4 way outgoing as per cat part No IHBB020004 of Havells or equivalent in Bajaj/ Crompton
Supply and fixing 25mm dia non metalic rigid medium grade PVC concealed counduit with all accessories for telephone and TV wire complete all as specified and directed
NIPANI INFRA AND INDUSTRIES PRIVATE LIMITED
SUMEET TRADING CORPORATION
M/S ZAHOOR AHMAD KHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .