Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹18.6 L+₹5.6 L (43.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹31,500
Closing Date
3 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) ADM AREA GWALIOR
AF STATION GWALIOR
IMPROVEMENT OT TYPE IV MD QTR OF KV NO 2 AT AF STATION GWALIOR
2021_MES_448063_1
8117/E8
Open Tender
Civil Works
Item Rate
180 days
AF STATION GWALIOR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF ADM AREA GWALIOR
₹31,500
Yes
2 Sept 2021
3 Jun 2021
5 Jul 2021
3 Jun 2021
3 Jul 2021
19 Jun 2021
3 Jun 2021 - 12 Jun 2021
60 days
Amount
Demolition of PCC in ground floor & pavings (including floor tile if any ) n.exc 15 cm thickness below or above GL, including removing excavated material to a distance n exc 2.5 KM distance and depositing where as directed, complete all as directed.
Taking down old damaged cement plaster on brick or stone wall etc incl raking out joints hacking for key & scrubbing down with water etc.complete all as specified and directed.
M&L for PCC, 1:4:8 Mix, type D2 (Using 20 mm graded stone aggregate) as in foundation, filling and mass concrete or sub base of floor complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 mix, type B0 (using 12.50 mm graded stone agg) as in sub base of floor finishing the surface even and rough to receive tiles etc complete all as specified.
M&L for 10mm thick Glazed Vitrified ceramic tiles, light shade (square/rectangular), area of each tile not exc 0.36 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15mm thick in CM (1:4) for laying floor finishes complete all as specified.
M&L for 10mm thick Glazed Vitrified ceramic tiles, light shade (square/rectangular), area of each tile not exc 0.36 Sqm as in vertical surfaces such as dado/ skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in Cement Mortar (1:3) complete all as specified and directed.
M&L for premium quality non skid, joints free, coloured ceramic floor tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but n exc 0.36 sqm as in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in Cement Mortar 1:4 complete all as specified and directed.
M&L for premium quality non skid, joints free, coloured ceramic floor tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but n exc 0.36 sqm as in vertical surfaces such as Dado/ Skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in Cement Mortar 1:3 complete all as specified and directed.
M&L for premium quality non skid, joints free, coloured ceramic floor tiles 7 to 8mm thick area of each tile exceeding 0.11sqm but n exc 0.18 sqm as in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in Cement mortar 1:4 complete all as specified.
M&L for premium quality non skid, joints free, coloured ceramic floor tiles 7 to 8mm thick area of each tile exceeding 0.06 sqm but n exc 0.11 sqm as in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in Cement mortar 1:4 complete all as specified.
M&L for premium quality, digital, bath concept tiles of approved design and pattern, of size 450x300x and 6 to 7mm thick coloured on vertical surfaces such as skirting /dados etc, set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in Cement Mortar 1:3 complete all as specified.
M&L for mirror polished machine cut Baroda green stone slab, 18 to 20 mm thick, in one piece of size not less than 1.20x0.25 M, as in window cills/ jambs etc, over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:3) complete all as specified and as directed.
M&L for cutting out of marble/ granite stone slab in suitable size for oval type wash hand basin including cutting, grinding, polishing edges in required shape and design complete all as specified and directed.
M&L for roudning to edges of stone slab (Granite/ Kota) one edge, as per approved design, as in steps, cooking platform and other similar works complete all as specified and directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size, straight or curved on plan exc 6M mean radius built in Cement Mortar 1:6 complete all as specified and directed.
M&L for brick work (Except Bricks) with sub class 'B' bricks old size, straight or curved on plan exc 6M mean radius built in Cement Mortar 1:6 complete all as specified and directed. Note: Serviceable bricks received against item No. 15 shall be reused in work.
M&L for brick work with old size half brick subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like bedded over and including 20 mm thick screed bed in Cement Mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
Demolition of RCC in Roofs, floors ( other than ground floors), beams, staircases, landing, chajjas and similar suspended work ( reinforced) including cutting of reinforcement to facilitate demolition complete all as specified and directed. Note : Reinforcement obtained from demolition will be considered credit Sch as scrap iron.
M&L for RCC, 1:1.5:3 Mix, type A1 (Using 20 mm graded stone aggregate) as in slab/ shelves, supported on wall etc. complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 8 to 10 mm dia cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for formwork for rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed.
M&L for formwork for rough finish to edge of concrete flats exc 10 cm but n'exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work, complete all as specified and directed.
M & L for rendering 15 mm thick in Cement Mortar 1:4 on fair faces of brick wall with mixing WPC as per manufacturer's instruction finished fair & even complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ as supply only.
M & L for rendering 15 mm thick in Cement Mortar 1:6 on fair faces of brick wall finished fair & even complete all as specified and directed.
M & L for rendering 5 mm thick in Cement Mortar 1:4 on concrete surfaces as on ceiling complete all as specified and directed
M & L preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls by rubbing/ sanding and applying two coats of distemper oil emulsion over and including a coat of primer over and a thin layer of wall care putty complete all as specified and directed.
M&L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper oil emulsion over and including a coat of primer over and a thin layer of wall care putty complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including cornices, plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, mass and effloresent salts and treating out greasy spots and applying one coats of white wash, complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling including cornices, plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, mass and effloresent salts and treating out greasy spots and applying one coats of white wash, complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including cornices, plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, ,ass and effloresent salts and treating out greasy spots, stopping nail marks, applying wall care putty in patches as required and applying two coats of exterior emulsion paint over and including one coat of primer, complete all as specified and directed. (Make/Brand : Apex Altima from Asian paint or other brand Berger/ Shalimar)
Taking down old chowkhat or frames with shutters (without taking off shutters from the frame) ex 1.5 Sqm but not exc 4.0 Sqm each and remove materials from site of work complete all as directed.
Taking down old chowkhat or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each and remove materials from site of work complete all as directed.
S&F including fabricating of aluminium powder coated having minimum thickness of powder coating 50 micron for window/ ventilator frame, shutters including necessary joining cleats, glazing clips, aluminium snap beading having minimum wt 100gm/RM, rubber neoprene gasket, screws, dash fasteners, rawel plug for fixing of screw in wall or floor etc., aluminium sections as approved by GE complete all as specified and directed. Notes : - (i) Only weight of aluminium section shall be measured and paid. No claim what so ever shall be entertained by the Govt on this account. (ii) Thickness of section shall not be more than 2mm.
S&F powder coated Aluminium grill with aluminium frame of design and pattern as approved by GE fixed with and including stainless steel screws in ventilators/ door etc complete all as specified and directed.
S&F Solif PVC frame (Single Rebated) of size 90mmx50mm, made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed 10x8 sheet metal CSK screws complete all as specified and directed. Note: Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and to hold doors properly for a long time.
S&F Solif PVC frame (Single Rebated) of size 140mmx55mm, made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed 10x8 sheet metal CSK screws complete all as specified and directed. Note: Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and to hold doors properly for a long time.
S&F factory made, solid PVC moulded shutters, with wood free EPS, 28 to 30 mm thick (Stiles) with 2, 4 or 6 raised panel design with 2 mm thick 3D wood grain noulded PVC sheet Polyurethane painted on the fron face and 2 mm prelaminated PVC sheet on back face complete all as specified and shown on drawings.
S&F factory made, solid PVC moulded shutters, with wood free EPS, 28 to 30 mm thick (Stiles) with 2, 4 or 6 raised panel design with 2 mm thick 3D wood grain noulded PVC sheet Polyurethane painted on the fron face and 2 mm plain colour PVC sheet on back face complete all as specified and shown on drawings.
S&F factory made PVC prelaminated wire gauze shutters, 30 mm thick (Stile) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and prelaminated printed PVC sheets for top rail, lock rail and bottom rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. The wire gauze shall be wrapped on an additional square 8 mm MS solid tube and this tube shall be welded to MS tubes. The wire gauze shall be stretched to tighten firmly complete all as specified and directed.
S&F for 100mm long butt hinge extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified.
S & F continuous (Piano) hinges ,mild steel, bright finished or electrogalvanised, width of flap 30 mm (when open), complete all as specified and directed.
S&F 150 mm long aluminum anodized barrel tower bolts of extruded section & fixed complete all as specified.
S&F 200 mm long aluminum, powder coated, barrel tower bolts of extruded section & fixed complete all as specified.
S&F for 150 mm long aluminum handles, fabricated type, anodized complete all as specified and directed.
S&F for 200 mm long aluminum handles, fabricated type, anodized complete all as specified and directed.
S&F 125 mm long, Hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&F for 250 mm long Aluminium anodised , sliding door bolt with hasp , staples (bolt type) and fixing clipsof sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified .
S & F for 150mm door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed complete all as specified.
S&F in repair mild steel door spring of size 200 mm long, complete all as specified and all as directed.
Supply and fix stainless steel wire cloth 0.36 mm nominal dia of wire and avg width of apertare 1.40 mm fixed with aluminium wire staples complete all as specified and directed.
Supply and fixing of rubber beading 40mm strip in bottom of door complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Re-fixing of old steel GI tubing, 15mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed. (Serviceable pipes shall be ontained from srl item no. 29 here-in-before for reuse.)
Re-fixing of old steel GI tubing, 20mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed. (Serviceable pipes shall be ontained from srl item no. 30 here-in-before for reuse.)
S&F GI tubing 15mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
S&F GI tubing 20mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
M&L for cutting chases in brick wall, pinning in and making good in cement mortar (1:3) to match with existing surface for cutting not exceeding 10 CM girth complete all as specified and as directed.
S&F in repair of vitreous china wash down water closet pan wall hung snow white with extened P trap including vitreous china flush cistern with twin flush and seat cover connection to drain flush pipe and anti syphonage pipe complete all as specified. [Make CERA cat Part No -2035 (CLAIR) for EWC wall hung , cat Part No - 2115,2235 for flush cistern and cat Part No - 2315 for seat cover or Hindware/Parryware as approved by GE
Supply and fix in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. Make: Cera Cat Part No. 2604T (Corona)/Hindware/Parryware or equivalent as approved by GE.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest and 'S' or 'P' traps (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nut, 450mm long. complete all as specified and directed.
S&F in repairs braided PVC connections 15mm size with CP nots and washers of length 450mm complete all as specified and directed. Make: Jaquar Cat Part No. ALD 805B/Hindware/Parryware or equivalent as approved by GE.
S & F in repair Vitreous china wash basin , white , flat back, size 550 x 400 mm,excluding waste pipe and tap but including chain and plug and porcelain stopper, brackets and cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed. Make: CERA Cat Part No. 1014 (Calibre) /Hindware/Parryware or equivalent as approved by GE
S&F in repair Oval type vitreous china wash basin, white, of size 500x400 mm (minimum) excluding tap, waste pipe but including chain plug and brackets complete all as specified and directed. Make: CERA Cat Part No. 10050 /Hindware/Parryware or equivalent as spproved by GE.
S&F in repair CP waste pipe, 32 mm dia with long shank and fly nuts etc for wash ahnd basin complete all as specified and directed.
S&F in repair 15 mm bore, two way, brass chromium plated, fancy type bib cock complete all as specified and directed.
S&F fancy type brass chromium plated wall mixer with and including Telephonic shower arrangements & with pipe bend 3-in-1 screwed down suitable for 15 mm bore GI pipe complete all as specified and directed. Make: L&K Cat Part No. SP-0427/Hindware/Parryware or equivalent as approved by GE.
S&F in repair of fancy type Wall mixer with and including shower & shower arm chromium plated screwed down 15mm bore complete all as specified and directed. Make: L&K Cat Part No. SP-0347/Hindware/Parryware or equivalent as approved by GE.
S&F in repair brass chromium plated hand shower with flexible pipe of length not less than 1.00 M (Minimum) fixed suitable for 15 mm bore pipe complete all as specified and directed. Make: L&K Cat Part No. OR-0337/Hindware/Parryware or equivalent as approved by GE.
S&F in repair fancy type, Brass, Chromium plated over head shower with swivel joint & arm, screwed down for 15 mm bore GI pipe complete all as specified and directed. Make: L&K Cat Part NO. SH-0677 (ONYX)/Hindware/Parryware or equivalent as approved by GE.
S&F in repair center hole basin mixer brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe of 15mm bore complete all as specified and directed. Make: L&L Cat Part No. SP-0427/Hindware/Parryware or equivalent as approved by GE.
S&F in repair of fancy type sink mixer, brass chromium plated with swivel spout (Wall Mounted), screwed down of 15mm bore complete all as specified and directed. Make: Hindware Cat Part No. F110020/Hindware/Parryware or equivalent as approved by GE.
S & F in repair fancy type angle stop cock, 15 mm dia, cast copper alloy, with chromium plated, screwed down , high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. Make: L&K Cat Part No. P-077/Hindware/Parryware or equivalent as approved by GE.
S&F in repair brass chromium plated fancy type towel rack complete all as specified and directed. Make: L&K Cat Part No. SP-0827/Hindware/Parryware or equivalent as approved by GE.
S&F in repair brass chromium plated fancy type towel ring, square with round flange complete all as specified and directed.Make: Jaquar Cat Part No. ACN-1121N/Hindware/Parryware or equivalent as approved by GE.
S&F in repair brass chromium plated fancy type tumbler holder with Tumbler complete all as specified and directed. Make: L&K Cat Part No. SP-0797/Hindware/Parryware or equivalent as approved by GE.
S&F Baroda Green marble Stone, 18 to 20 mm thick, machine cut, Area not exceeding 0.03 Sqm as in corner shelf, cut to shape one fourth round & embedded in wall and jointed with grey cement slurry & pointed in white cement with admixture of pigment to match the shade of colour of stone complete all as specified and directed.
S&F Baroda Green marble Stone, 18 to 20 mm thick, machine cut, Area not exceeding 0.03 Sqm but not exceeding 0.07 Sqm as in corner shelf, cut to shape one fourth round & embedded in wall and jointed with grey cement slurry & pointed in white cement with admixture of pigment to match the shade of colour of stone complete all as specified and directed.
S&F in repair brass chromium plated handspray with flexible pipe not less than 1.00 (Minimum) fixed for EWC/WC suitable for 15 mm bore pipe complete all as specified and dirceted. Make: Jaquar Cat Part No. ALD-563 or equivalent as approved by GE.
S&F 20 mm ball/float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and as approved by GE.
S&F in repair PVC flexible pipe 32 mm dia with socket for steel sink upto floor level and length not less than 0.60 M complete all as specified and directed.
S&F in repair PVC flexible pipe 40 mm dia with socket for steel sink upto floor level and length not less than 0.60 M complete all as specified and directed.
S&F in repair mild steel peg set of six of best quality as approved by GE complete all as specified and directed.
S&F in repair chromium plated grating of size 100 mm dia complete all as specified and directed.
S&F in repair chromium plated grating with hole of size 100 mm dia complete all as specified and directed.
S&F in repair brass, chromium plated soap dish complete all as specified and directed.
S&F in repair toilet paper holder, twin type, CP, fixed to wall with chromium plated brass screws and rawl plug complete all as specified and directed.
S&F 5mm thick beveled edge best quality looking mirror of size 600x450 mm with 30 mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 4mm thick AC bldg board, complete all as specified and directed.
S&F in repair PVC mirror cabinet of size 0.45x0.30 M with shutter complete all as specified and directed. Make: Prayag/ Commander
Dismantling of cast iron or AC reinforced concrete drain pipe 100/75 mm dia jointed in cement mortar and taking out of trenches if required complete all as specified and directed.
S&F cast iron soil, waste and vent pipes (Spun type) in any length with or without ears, with cement joints, laid in trenches for 100 mm bore of pipes complete all as specified and directed.
S&F cast iron soil, waste and vent pipes (Spun type) in any length with or without ears, with cement joints and fixed to wall for 100 mm bore of pipes complete all as specified and directed.
S&F cast iron soil, waste and vent pipes (Spun type) in any length with or without ears, with cement joints, laid in trenches for 75 mm bore of pipes complete all as specified and directed.
S&F cast iron soil, waste and vent pipes (Spun type) in any length with or without ears, with cement joints and fixed to wall for 75 mm bore of pipes complete all as specified and directed.
S&F CI bend for 100 mm bore CI pipe complete all as specified and directed.
S&F CI bend for 75 mm bore CI pipe complete all as specified and directed.
S&F CI branch pieces, single (equal or unequal), ordinary or inverted(spigot/socketed type) or with parallel branches with oval access doors for following bore of pipe complete all as specified and directed:- (a) 75 mm bore
(b) 100mm bore
S&F cast iron bend (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors for 100 mm bore pipe complete all as specified and directed.
S&F 100 mm bore CI socket (double) collars with cement joints complete all as specified and directed.
M&L for cast iron floor trap with grating including jointing to waste pipe fixed in PCC (1:2:4) type B1, of size 75 mm complete all as specified & directed.
S&F rotational moulded polythene water storage tank of capacity 1000 litres (Cylindrical/vertical with closed top), double layer construction, ISI marked, hoisted & fixed in position including light grade over flow pipe 450mm, waste pipe 600mm long with fitting etc. including of 20 mm dia, ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, 20mm bore minimum weight 210 gms including dismantling / taking out of old water tank of capacity of exc. 500 litres but not exc. 1000 & removing to where directed complete all as specified and as directed.
S&F in repair gunmetal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, for 20 mm bore pipe complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality type & glazing with oil putty in squares exc 0.5 Sqm in each pane, complete all as specified and directed.
S&F 4 mm thick sheet glass frosted one side & glazing with oil putty in squares exc 0.5 Sqm in each pane, complete all as specified and directed.
S&F drapery rod, fancy type, made out of 25mm dia Aluminium pipe, Powder coated with natural wood finish with and including wooden ornamental attachment at both ends including one set of ornamental decorative finish wooden clamp and matching curtain rings, minimum 8 rings per running meter, complete all as specified and directed. Make: Aerolux/ MEC/ Vista.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 510mm bowl size 510mm x 410mm x 200mm, complete all as specified and directed.
S&F plate rack with racks and guard bars made out of stainless steel minimum 1mm thick, over all size 750mm X 900mmx250mm and assembled with using brass nuts, bolts and washers complete all as specified and as directed. Make: Prayag or equivalent as approved by GE.
Taking down old cement plaster from conc surfaces incld APP mambrane and remove materials from site of work complete all as directed.
Demolition of reinforced cement concrete of any description and if any position not otherwise specifically provided for and removing the dismantled material to a distance upto 2.50 KM and depositing where directed.
Roughening surface of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and as directed.
M&L for applying neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and directed.
M&L for PCC, 1:2:4 Mix, type B0 (Using 12.50 mm graded stone aggregate) as in levelling course to maintain the true roof slope, finished even and fair without using extra cement complete all as specified and directed.
M& L for cutting out cracks to V section in existing roofs or terracing, clening out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
M&L for applying one coat of cold bituminius primer over cleaned surface @ 0.30 Ltr per sqm and one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over bituminius primer then followed by APP modified five layer polymeric mambrane 3 mm thick minimum weight 3.5 Kg per Sqm reinfored with polyster non woven fabric (weighting not less than 150 Gm per Sqm) manufactured by M/S STP LTD or its equivelant or IWL laid as per the maufacturer's instruction with side over lap of 75 mm and end over lap of 100 mm and applying one coat of polymericcc modified bitumen 85/25 @ 1.20 Kg per Sqm finally finished with two coats of aluminium paint @ 0.20 Ltr per Sqm for each coat complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregates, as in kerb/ benching/ coping, bed plates, for fixing of hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed. Make: Pididrop LW (101) or Dr Fixit
M&L for 10 mm thick screed bed on fair face of PCC padding in cement mortar 1:3 finished even and fair with water proofing compound complete all as specified and directed. Note: Water proofing compound shall be measured and paid respectively under respective item of BOQ.
S&F coloured, decorative type, earthen Mangalore tiles, interlocking at side joint, of design and pattern as approved by GE laid over and including 15 mm thick screed in CM 1:4 complete all as specified and directed.
M&L for providing and injecting chemical emulsion for Post Construction Anti termite treatment along the external perimeter of wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
M&L for providing and injecting chemical emulsion for Post Construction Anti termite treatment under the existing floor using chemical emulsion @ 1 litres per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:4 to match the existing floor complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling complete all as specified and directed.
M&L for PCC (1:3:6) type C-1, using 20mm graded stone aggregate as in surface channel and drain including saucer drain and toe wall etc complete all as specified and directed.
M&L for extra for forming fair finished drain, or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends, complete all as specified and directed.
S&F in repair 18 mm thick Rajshri celuka ply of grade 1 quality of one side prelaminated of approved colour and other side white, fixed with screws, solvent cement/ adhesive to make the kitchen cabinet and CB shutters complete all as specified and directed.
S&F in repair 18 mm thick Rajshri celuka ply of grade 1 quality, both side white in colour, fixed with screws, solvent cement/ adhesive to make the shelves, partitions and drawer of kitchen cabinet, CB etc complete all as specified and directed.
S&F in repair 12 mm thick Rajshri celuka ply of grade 1 quality, both side white in colour, fixed with screws, solvent cement/ adhesive to make kitchen cabinet side, top and bottom shelves inside the the cabinet and shutter of drawer complete all as specified and directed.
S&F Stainless steel (SS-204) cup saucer basket of size 19"x20"x4", best quality, complete all as specified and directed. Make: Ultrafresh/ Kitchen Gold or equivalent as approved by GE.
S&F Stainless steel (SS-204) Thali basket of size 8"x19"x20", best quality, complete all as specified and directed. Make: Ultrafresh/ Kitchen Gold or equivalent as approved by GE.
S&F Stainless steel (SS-204) plate basket of size 19"x20"x6", best quality, complete all as specified and directed. Make: Ultrafresh/ Kitchen Gold or equivalent as approved by GE.
S&F Stainless Steel (SS-204) perforated cutlery basket of size 21"x20"x4" mm, best quality, complete all as specified and directed. Make: Ultrafresh/ Kitchen Gold or equivalent as approved by GE.
S&F Stainless steel (SS-204) large utensil basket of size 32"x20"x8", best quality, complete all as specified and directed. Make: Ultrafresh/ Kitchen Gold or equivalent as approved by GE.
S&F stainless steel drawer telescopic channel of size 500 mm long having load bearing capacity of 35 Kg complete all as specified and directed. Make: Godrej/ Link or equivalent as approved by GE.
S&F stainless steel handles of 110mm long for kitchen cabinate shutter complete all as specified.
S&F stainless steel magnet catcher for the cupboards/cabinet including all necessary fixing arrangements complete all as specified and directed.
S & F auto closing hinges 35mm of 0 crank (KH-001) or 8 crank (KH-002) approved quality openable at 110 degree for kitchen cabinete shutter complete all as specified and directed.
M&L for 60mm thick machine pressed,coloured, glossy finish(rubber moulded) precast cement concrete interlocking pavers/ tiles Grade M-35 made with grey cement and pigment any size, pattern and shape as approved by GE, laid dry over sand cushion in patterns with different colour paver block /tiles complete all as specified and directed. (Note : Sand cushioning and sub base will be measured seperately)
M&L for sand filling under floors or in foundation including watering and consolidation etc complete all as specified and directed.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Removal of surplus spoil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size, straight or curved on plan exc 6M mean radius built in Cement Mortar 1:4 complete all as specified and directed.
M&L for providing precast reinforced cement concrete 1:1.5:3 Mix, Type A1 (Using 20 mm graded stone aggregate) as in cover slab of manhole, septic tank, soak well etc, set in CM 1:4 with plain fair faces including chamfered weathering, throating etc including necessary form work complete all as specified and directed. Note: Reinforcement shall be measured and paid separately under respective item of BOQ.
M&L concrete bed to pipes in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for 150 mm bore sewer pipe line complete all as specified and directed.
M&L for 150 mm bore salt glazed stone ware (SGSW) pipe conforming to IS, laid in trenches and jointed in CM (1:1) for complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B1 smooth finish and reforming benching as required complete all as specified and directed.
Demolition and breaking up drain pipes (PVC/ SGSW/ AC/ RCC pipe) of 150 mm bore of pipe, set in cement mortar complete all as specified and as directed.
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/ste el conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, FR single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor FR single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A 'Make of Cable/wire:- : Havells /Finolex/Polycab Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering, Make of Laminated Sheet:-/Hylam/National
Description all as per item No 155 here-in-before but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
Description all as per item No 155 here-in-before but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent.
Description all as per item No 14 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
S&F switch socket combination multi purpose, 5 Pin 6 amps, 240 volts flush typeWith Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
M&L for socket outlet 2 in 1, 5 pin, 6 Amps, 240 volts flush type white ivory finish complete all as specified. Make :- Anchor(Panta) , Cona , Leader
S&F switch socket combination multi purpose, 6 Pin 6/16 amps, 240 volts flush typeWith Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. Make :- Anchor(Panta)/ Cona/ Leader
M & L for switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified. Make :- Anchor(Panta)/ Cona/ Leader
M&L for lamp holder insulated body with back plate for batten fitting complete all as specified. Make :- Anchor(Panta) / Cona/ Leader
Supplying & fixing for switch bell push, flush type, 5 Amps, single pole, one way , 230 volts AC circuit white ivory finish complete all as specified & directed. (Make : Anchor(Panta)/Cona/Leader)
Supply and fixing bell Ding Dong, AC 230 V.single pole complete all as specified and directed. Make:-Cat part No Grand Stereo 3421 of cona or equivalent of Leader/ Anchor(Panta).
S&F decorative slim linear LED T5 AL batten tube light fitting 1x20 Watt light with co extruded polycarbonate body, enviromently friendly, energy efficient, ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 50/0.20 flexible PVC sheathed and fixing arrangements for fixing the light fitting to wall/ roof surfaces complete all as specified and directed. Make:- Havells Cat Part No. LUMILINEBS20WLED865SPCWH/ Surya Cat Part No. SLEBT-20/ CG Cat Part No. LCTL 18 CDL
S&F bulk head LED fitting 10 watt energy saving, new generation, IP 65 luminaire complete with opel diffuser complete with lamp all as specified and directed. Make : - Havells Cat part No HEXAFT10WLED857SSYMBOPC/ Surya Cat Part No. SLE BH-10/ CG Cat Part No. LBPH-10CDL
S&F LED mirror light 1X10 Watt complete with lamp all as specified and directed. Make : Havells Cat part No ENDURALINEARNEOBS10WLED865SPCWH/ Surya Cat Part No. SLE-BT-10/ CG Cat Part No. LCTL-9CDL
S&F in repair LED down light, IP-55, surface mounted LED down light, in Engineering plastic housing with clear prismatic diffuser, 6 W LED complete with lamp etc and all accessories prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose complete all as specified and directed.
Dismantling & Taking out MCB DBs any size , any type and capacity complete all as specified and directed.
Supply and fixing of sheet metal enclosure Double door for DB’s Single Pole and neutral, 8 Way DB for using MCB/ Isolators with havng aluminium bus bar suitable for 200 Amps rating complete all as specified and directed. Make: Havells/L&T/Legrand
S&F MCB Single pole and neutral 32 Amps, 240 Volts, 10 KA complete all as specified and directed. Make:Havells/L&T/Legrand
S&F MCB single pole 6 to 30 Amps, "C" Curve ,240 Volts complete all as specified. Make:Havells/L&T/Legrand
Supply and Fixing step type electronic fan regulator single phase ,230 volt, 100/120 watt . (Size of PT switch ) Make:-Cat part No 3211 of cona or equivalent of Leader/ Anchor(Panta).
M&L for as in repair sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FR of size 4 Sqmm as earth continuity conductor all as specified and directed. (NOTE : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) Make of cable : Havells/Gloster/Polycab/Plaza/Finolex/Universal & Make of PVC conduit : AKG/Vikas/Plaza/Kinjal).
M&L for as in repair sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FR of size 6.0 Sqmm as earth continuity conductor all as specified and directed. (NOTE : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) Make of cable : Havells/Gloster/Polycab/Plaza/Finolex/Universal & Make of PVC conduit : AKG/Vikas/Plaza/Kinjal).
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as required and directed. Make:Legrand/ABB/Schneider
M&L for taking down carefully serviceable ceiling fan/exhaust fan (any make any size) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber real, painting with two coats of synthetic enamelled paint after preparing surfaces and re-fixing in the same position after repair complete all as specified and directed.
Supply and fixing Street light fittings LED15W new generation energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as light sourceand lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 suitable for pole dia O 43mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washers all directed. Make: Havells Cat part No - ENDURAPEARLSL15WLED757SASYTOPC/ Surya Cat Part No. SLEUL 15W IP66LXN/ CG Cat Part No. LSTS-15CDL
Taking down carefully from existing place for Geyser of any type and capacity by disconnecting electrical/ Water supply connection and refixing the same after civil work complete all as specified and directed.
M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed. Note: Earth strip and protection pipe upto and including 7.5m deemed included in unit rate quoted by the contractor.
S&F and laying, connecting and testing LT cable, XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade as per IS 7098 with stranded aluminium conductor of size 10 Sqmm, 2 Core complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply & Laying sub class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise panel recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
R.B. ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .