| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹35.3 L+₹1.4 L (4.05%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹41.7 L+₹7.7 L (22.8%)Rejected-Finance NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | Rejected-Technical 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | - | Rejected-Technical Not meeting eligibility cretiria (Not having required category) | |
| 5 | Rejected-Technical 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | - | Rejected-Technical Not meeting eligibility cretiria (Not having required category) |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
29 Oct 2021, 6:00 pmClosed
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
REPAIRS/MAINT OF EXTERNAL ELECTRIFICATION INCLUDING CONNECTED WORKS UNDER GE CHENNAI
2021_MES_476880_1
88407/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Chennai
As per NIT
9 documents required · 9 mandatory
₹500
GE Chennai
₹96,000
Yes
11 Jan 2022
22 Sept 2021
6 Nov 2021
22 Sept 2021
29 Oct 2021
9 Oct 2021
22 Sept 2021 - 29 Sept 2021
Amount
BOQ UPLOADED ON 04 OCT 2021
SCH "A" PART-I (E/M ITEMS)
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified and as directed.
Excavating in trenches not ecxeeding 1.5m wide, exceeding 1.5m and not exceding 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Fine sieved excavated dry soil laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
(a) Punned thickness only shall be measured. (b) The soil used shall be free from sharp grains and deletrios materials like dry/decayed plants etc.,
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, (Earthed), 3 core, cross sectional area 95 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, (Earthed), 3 core, cross sectional area 120 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 95 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 150 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 185 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Taking out existing cable any type / cross section and Supply, laying, connecting and testing LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 240 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
Note for item No 9.00 to 14.00:-
(a) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(b) Earthwork, cushioning, protection for cable etc., as required shall be measured and paid separately.
Steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type 410, SP-22 (8.50 metres long) and shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth and the remaining, portion of the exterior shall be painted with one coat of red oxide zinc chrome primer as in repairs complete all as specified and as directed.
Earthwork, PCC foundation, coping etc as required for erection of pole shall be measured and paid separately.
Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping of poles and similar work complete all as specified and as directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of poles, stay assembly complete all as specified and as directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT opf size 25x20cm size as in repairs complete all as specified and as directed.
Air break, gang operated switch, with current rating 400 Amps, HT, 11000 Volts, triple pole mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level as in repairs complete all as specified and as directed.
Lightning arrester, expulsion type complete with all fitting transmission class, discharge capacity 65 Kilo Amps suitable for 11000 Volts rating, ISI marked as in repairs complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm as in repairs complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm as in repairs complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm as in repairs complete all as specified and as directed.
Synthetic insulated mat 2mm thick of size 2mtr x 1mtr suitable for HT installation as in repairs complete all as specified and as directed. Make : Jyoti/Denson or equivalent.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with necessary fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 50mm for cable protection complete all as specified and as directed.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with necessary fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 80mm for cable protection complete all as specified and as directed.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with necessary fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 100mm for cable protection complete all as specified and as directed.
Note for item NO 25.00 to 27.00:-
Earthwork as required shall be measured and paid separately.
MCCB 200 Amps, FP, 415 Volts, 50 Hz, AC supply,with breaking capacity of 36 kA adjustable type complete all as specified and as directed.
MCCB 250 Amps, FP, 415 Volts, 50 Hz, AC supply,with breaking capacity of 36 kA adjustable type complete all as specified and as directed.
M&L for preparation of old painted surfaces, removing dust and other deposited materials by scraping from HT panels indoor/out door type and applying two coats of synthetic enamel paint grey colour complete all as sdirected.
Taking down, servicing and overhauling of HT, 11KV VCB carrying out complete cleaning with clean cloth & cleaning agent, lubrication of the mechanism & greasing, servicing and testing of earth fault relay, over load relay, digital voltmeter, digital ampmeter, all protective equipments inside the VCB including renewal of indication lamps, internal wiring for indication lamps, wiring for tripping coil and tripping switch set, renewal of No volt coil of suitable capacity and checking the complete VCB for proper functioning complete all as directed by the Engineer-in-charge. Note :- Unit rate quoted is deemed to be inclusive of renewal of all defective parts and nothing extra will be admissible.
Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, "two in series" assembly for tension with cast aluminium, 4 U bolt tension hardware and tension clamps for conductors, working pressure 11000 volts as in repairs complete all as specified and as directed.
Halogen lamp 1000watt, 230 Volts including connecing up and testing for proper functioning complete all as directed.
Horn Gap type Fuse unit, 11000 volts grade, mounted on insulators and steel frame,400 Amps as in repairs complete all specified and as directed
Dismantling cross-arms of mild steel channel or angle sections etc., complete and taken on credit and provision of new Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Taking down, servicing and overhauling of LT, 1100V ACB carrying out complete cleaning with clean cloth & cleaning agent, lubrication of the mechanism & greasing including renewal of tripping coil 440V, contactors, wiring for tripping coil and indication lamps including wiring and checking the complete ACB for proper functioning complete all as directed by the Engineer-in-charge. Note :- Unit rate quoted is deemed to be inclusive of renewal of all defective parts and nothing extra will be admissible.
Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as specified and as directed.
Spreading and levelling sand below interlocking paver block paving as cushioning, complete all as specified and as directed.
Outdoor Air break (switch) insulator for 11000 volts suitable for current rating of 200 Amps as in repairs complete all as specified and as directed.
Bottle type fuse (vaccum intraper) suitable for 11000 volts fitted inside the VCB as in repairs compele all as directed complete all as specified and as directed.
GI pile bracket made out of 40mm dia pipe light grade 2m length bent to required shape suitable for fixing of street light fittings including providing necessary clamps, nuts and bolts etc., complete all as directed
LED flood light 70 Watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant compete with driver and lamp complete all as directed
Preparation of old painted surfaces, removing dust and other deposited materials by scraping from HT/LT tubular pole 11mtr long, painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, street light bracket with one coat of aluminium paint including writing pole Nos as directed by the Engineer-in-charge.
Preparation of old painted surfaces, removing dust and other deposited materials by scraping from HT/LT tubular pole 8.5/9 mtr long, painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, street light bracket with one coat of aluminium paint including writing pole Nos as directed by the Engineer-in-charge.
Taking out the existing PVC/XLPE 1100 Volt grade LT UG cable, removing the old lugs and providing new aluminium lugs for cable of size 16sqmm to 25 sqmm with crimping tools properly insulated around the burnt cable and reconnecting the cable in the panel, testing for proper functioning compete all as dierected.
Taking out the existing PVC/XLPE 1100 Volt grade LT UG cable, removing the old lugs and providing new aluminium lugs for cable of size 50 sqmm to 70 sqmm with crimping tools properly insulated around the burnt cable and reconnecting the cable in the panel, testing for proper functioning compete all as dierected.
Taking out the existing PVC/XLPE 1100 Volt grade LT UG cable, removing the old lugs and providing new aluminium lugs for cable of size 95 sqmm to 150 sqmm with crimping tools properly insulated around the burnt cable and reconnecting the cable in the panel, testing for proper functioning compete all as dierected.
Taking out the existing PVC/XLPE 1100 Volt grade LT UG cable, removing the old lugs and providing new aluminium lugs for cable of size 185 sqmm to 240 sqmm with crimping tools properly insulated around the burnt cable and reconnecting the cable in the panel, testing for proper functioning compete all as dierected.
Supply and laying of pipe line by using trenchless technology of 80mm bore GI pipe medium grade with other jointing accessories complete all as specified and as directed. Note:- Supporting documents such as photographs etc shall be submitted by the contractor while claiming payment and the same shall be kept on record.
GI earth strip of size 25x4mm with necessary nuts and boltscomplete as in repairs all as specified and as directed.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 25mm x 4mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
PSK Enterprises
G.L.THIRUMALAI NAIDU AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .