Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹26.1 L Quoted ₹27.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹30.8 L+₹3.6 L (13.1%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | ₹30.8 L+₹3.6 L (13.1%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹31.4 L+₹4.2 L (15.2%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | ₹31.4 L+₹4.2 L (15.2%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹34.5 L+₹7.2 L (26.4%)Rejected-Finance | ₹34.5 L+₹7.2 L (26.4%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹34.5 L+₹7.2 L (26.5%)Rejected-Finance | ₹34.5 L+₹7.2 L (26.5%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
7 Oct 2021, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF COOLING APPLIANCES WITH CONNECTED MISC ITEMS AND REPAIR MAINT OF STREET LIGHTS UG CABLES SWITCH GEARS AND CONNECTED EXTERNAL ELECTRIFICATION DISTRIBUTION SYSTEM WORKS AND REPAIR MAINT OF INTERNAL ELECTRIFICATION WORKS REPLACEMENT OF
2021_MES_474384_1
GE/NORTH-41/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (N) DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹98,000
Yes
9 Nov 2021
10 Sept 2021
11 Oct 2021
10 Sept 2021
7 Oct 2021
24 Sept 2021
Amount
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring with single core FRLS, PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through conduit pipe/casing caping including replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the following :-
One light point controlled by one switch
One ceiling/exhaust fan point controlled by one switch
One socket outlet 5 Amps controlled by one switch on same board
One socket outlet 5 amps controlled by one switch on independent board
One bell point controlled by one bell push switch
All as per above item No 2 but wiring with 2.5sqmm copper wire and 1.5sqmm earth wire for socket out let 16 Amps on independent board
All as per above item No 2 but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic suitable size PVC conduit complete with all PVC conduit accessories suitable for modular type switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- (Note: 1. Rates deemed to be included for GI metal flush box reqd modulars size, Modular cover inner and outer plates, blanking plates etc complete 2. Modular switch, sockets, Bell push measured and paid separately under relevant items).
One light point controlled by one switch
One ceiling/exhaust fan point controlled by one switch
One socket outlet 5 Amps controlled by one switch on same board
One socket outlet 5 amps controlled by one switch on independent board
One bell point controlled by one bell push switch
All as per above item No 5 but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
All as per above item No 5 but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 2.5 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
S&F in replacement of concealed metal box 10/12 modules having high durability,corrosion resistant,earthing terminal with repalcement of 3 mm thick plastic laminated hylam sheet top cover with brass screws , cup wahser and cutting of grooves for switchs,sockets and regulator etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. (Note:1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Switch,sockets,regulators,bell push to be measured and paid separately)
All as per above item No 8 description but 06/08 modules complete.
All as per above item No 8 description but 03/04 modules complete.
All as per above item No 8 description but 01/02 modules complete.
S&F in replacement of concealed metal GI box 12/16 modules having high durability,corrosion resistant,earthing terminal with repalcement of modular type inner and outer plate covers with screws,incl all cutting/chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. (Note:1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Modular switch,sockets,regulators,bell push to be measured and paid separately)
All as per above item No 12 description but 06/08 modules complete.
All as per above item No 12 description but 03/04 modules complete.
All as per above item No 12 description but 01/02 modules complete.
S&F Switch piano flush type 5/6 Amps single pole one way 230 Volts complete
S&F Switch piano flush type 15/16 A single pole one way 230 Volts complete
S&F Socket Outlet 2 in 1, 3/5 pin 5 Amps flush type 230 Volt complete
S&F Socket Outlet 2 in 1, 3/6 pin 5 and 15 Amp flush type 230 Volts complete
S/F Bell push, flush type 5 Amps 230 Volts complete
S&F electronic fan step regulator flush type 120 watt, 230 Volt complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F lamp holder, 230 volt AC, PVC / Polycarbonate type of angular shape with back plate suitable for batten fittings complete
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete.
S&F modular switch 6 Amps, one way, one module 240 volts complete
S&F modular socket, 3/5 pin 6 Amps,240 volts, 2 module complete
S&F modular switch 16 A, 1 module,240 volts complete
S&F modular socket 6/16 A, 5/6 pin, 2 module, 240 volts complete
S&F modular Bell push 6 Amps, one module 240 volts complete
S&F modular fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module complete
S & F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps.
M&L in repair for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area 1100 V,stranded copper conductor, multistranded, and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
All as per above item No 32 herein before but with 6 sqmm two runs and 4 sqmm one run as earth wire
All as per above item No 32 herein before but with 10 sqmm two runs and 6 sqmm one run as earth wire
S&F MCB DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, 4 way IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following :-
Ditto all as per item No 35 above but 8 way
Ditto all as per item No 35 above but 12 way
S&F of factory made distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable complete
S&F of load line distribution box 8 way, AC, TP & neutral metal enclosure, glazed double dooor, 415V AC, IP-43, concealed type with IP-43 protection complete with suitable bus bar, neutral link, earth link suitable for MCCB 125/160 Amps as incomer and MCB SP as out going all as directed.
S&F in repairs for MCB TPN, 240 Volts, AC, 63 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F in repairs for MCB TPN, 240 Volts, AC, 40 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F in repairs for MCB, DP/SPN, 240 Volts, AC, 40/63 Amps of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified and directed.
All as per above item but 16 to 32 Amps
S&F in repairs for MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete
S&F in repairs for MCCB 4 Pole, 415 volt, AC,63 amps,fixed type,suitable for load line DB/LT PB connection complete all as specified and directed.
All as per above item but 100 amps, 25 kA
S&F in repars for blank plates for MCB space in any type of DBs complete
S&F in repairs of rigid non metalic 25mm dia PVC conduit with all ftgs(tees,bends,elbows,reducers, bell mouth,saddles,pipe hooks) complete.
S&F in repairs of GI flexible conduits 25mm dia with check nut and clamps and accessories complete.
S & F LED Batten type fitting for surface/wall mounted 20 W,230V,6500K integrated electronic driver completely pre wired, LED 4 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S & F LED Batten type fitting for surface/wall mounted 22 W,230V,6500K integrated electronic driver completely pre wired, LED 4 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S & F LED Batten type fitting for surface/wall mounted 9W,230V,6500K integrated electronic driver completely pre wired, LED 2 feet fitting with polycarbonate housing & integrated electronic driver complete with connector blok, screws , gutties etc.and removing the UNSV fitting and all as specified and directed.
S&F surface/recess mounted LED panel type 36W,230V complete with driver full window glarefree opal diffuser LED panel of size 2ftx2ft with CRCA powder coated white housing, CDL/warm type illumination complete with all accessories required for connection and making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
S&F indoor decorative wall light fixture suitable for 10 W LED lamp,230V for soft light ambiance, made up of polycarbonate, spiral B22 base lamp holder used,globe shape, incl LED lamp 10W(warm/CDL type) and remove the UNSV fittings and all as specified and directed.
S&F in repairs of Indoor decorative aesthetically designed wall bracket light fixture,cylindrical/round shape, fixed on wall with the help of screws incl complete all as specified and directed. (Make/Model - as per sample)
S&F lighting fixture wall mounted LED bulk head luminaire 10W,230V, made of die cast aluminium with opal diffuser IP 65, complete with mounting Brackets & accessories as required with connections and remove the UNSV fittings and all as specified and directed.
Supply and fixing Indoor recessed/surface type mounted LED luminaires round/square type light weight plastic body downlight fitting 15 Watt, CDL/Warm type with all accessories 3 core copper wire for connection, making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
Supply and fixing Indoor recessed/surface type mounted LED luminaires round/square type light weight plastic body downlight fitting 5 Watt, CDL/Warm type with all accessories 3 core copper wire for connection, making good the disturbed any type of ceiling and remove the UNSV fittings and all as specified and directed.
S&F Indoor decorative 4W LED type bed side light fittings with all accessories 3 core copper wire for connection and remove the UNSV fittings and all as specified and directed.
S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed.
M&L for making hole for fixing of exhaust/ventilation fan size 150 mm to 380mm with necessary civil work, alteration in exist ventilation window of iron/aluminium frame as per site requirement complete make good the wall/ventilation window match with exist complete all as specified and directed.
S&F in repairs for perforated MS cable tray (nor less than to 200 x 40 x 40x 2 mm) including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended or wall fixed from the ceiling with MS suspenders and including painting etc suitable to accommodate LT XLPE/PVC cables with anchor, fasteners , mounting brackets, suspension rods complete all as specified and directed. (Note: Rates deemed to be included for removing of exist cables and rearrangement of cables in cable trays complete as per site requirement)
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of 4 mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and as directed .
Taking down ceiling fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire,down rods, canopies,minor spares,painting and re-winding all as specified and directed. (Note : Rubber Bush, Gun Metal Bush, bearing,capacitor, twin core twisted copper flexible wire, down rods, canopies, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding from the stater of the ceiling fan any sweep with matching gauge and turns of super enamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Painting of ceiling fan with set of blades of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete all as specified and as directed.
Taking down Exhaust/Ventilation fan of any sweep by unscrewing nut/bolts from its position (high rise bldgs up to 8 storey height) and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire,louvers,shutters,painting,minor spares and re-winding all as specified and directed. (Note : Rubber Bush, Gun Metal Bush, bearing,capacitor, twin core twisted copper flexible wire, Louvers,shutters, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding of the Exhaust fan up to 300 mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
All as per item No 69 above item but 380/450mm Sweep.
All as per item No 69 above item but ventilation fan up to 200mm Sweep.
Painting of exhaust fan of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete all as specified and as directed.
Supply only for ball bearing number of 6201 to 6204 as required. (Make : SKF/NBC).
Supply only ceiling fan gun metal bush bearing as required
Supply only for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan .
Supply only for PVC holder for condenser housing.
Supply only for twin twisted copper flexible wire size of up to 0.5 sqmm.
Supply only capacitor 0.8/1 Mfd, 240 Volts.(Make/Model- as per sample)
Supply only capacitor 2.5 Mfd, 240 Volts.
Supply only capacitor 3.15 Mfd, 240 Volts.
Supply only PVC canopy for ceiling fan.
Supply only down rod for ceiling fan 1' length, down rod colour match with exist fan to any height complete all as directed.
M&L for ceiling fan blade suitable for 1200mm sweep for complete.
All as per above but 1400 mm sweep.
S&F in replacement louvers with shutter metallic body suitable for single phase 240 Volts AC heavy duty exhaust fan upto 450 mm sweep with necessary fixing accessories after taking down existing all as specified and directed. NOTE: Louver Shutter are to be replaced up to high rise bldgs 8 storey including all necessary T&P and fixing accessories etc.
S&F in replacement louvers with shutter plastic body suitable for single phase 240 Volts ventilation fan 200 mm sweep with necessary fixing accessories after taking down existing all as specified and directed. NOTE: Louver Shutter are to be replaced up to high rise bldgs upto 8 storey, including all necessary T&P and fixing accessories etc.
M&L for exhaust fan blade (metal body) suitable for 300/380/450mm sweep for exhaust fan complete all as directed. (Make as per sample)
M&L for ventilation fan blade (PVC type) suitable for 200mm sweep complete all as directed. (Make as per sample)
Supply and fixing in repair of 300mm dia, 900 RPM, exhast fan witlh louvers including frame, blades complete and UNSV Ex fan deposit in E/M store yard. . (Make as per sample)
Supply and fixing in repair of 300mm dia, 900 RPM, wall mounting fan oscalating type complete and UNSV fan deposit in E/M store yard.(Make as per sample)
Supply and fixing in repair of 200mm dia, 900 RPM, fresh air fan with plastic louvers incl frame complete all as specified and directed. (Make as per sample)
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts. descaling with acid washing and reassembling after cleaning and replacing defective parts and re-installing the same in original position with fastner nut and bolts and making necessary electric and water supply connection and testing complete all as specified and directed. (Note: Spare items shall be measured and paid seperately as supply only under relevant items)
Supply only geyser inner water tank 25 Ltrs capacity steel body/glass line coated tanks with nut and bolts as per sample ,duly tested complete all as specified and directed.(Make & Model- as per sample)
Supply only of Heating element capacity 1.5/2 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete all as specified and directed.Make : as per sample
Supply only thermostat suitable for 25 ltrs capacity geysers as per sample.
Supply only Heavy duty hot water connection, SS rope threaded type with brass unions, neoprene washers at both ends, 45cm long 15mm bore complete.
Supply only cold water connection, PVC connection with brass unions,neoprene washers at both ends, 45cm long 15mm bore complete.
Supply only replacement of safety valve/Pressure release valve for geysers of any type/capacity.
Supply only indicator lamp Red/Green suitable for geyser geysers of any type/capacity.(Make as per sample)
Supply only geyser base plate/apparatus assembly of any capacity any model all as specified and directed complete. Make as per sample.
Supply only geyser top and bottom cover any capacity any model all as specified and directed complete. Make as per sample.
S&F in replacement of glass wool heat resistance thermal type/heavy duty puf insulation glass wool of exist type (8 kgs) for 25 ltrs capacity geysers complete.
M&L soldering/brazing inner geyser tanks 25 liters capacity with brass solder and refixing after testing the leakage complete incl replacement of rubber packaging ring heat resistance type all as specified directed complete.
S & F in repair industrial type two pin and earth plug top 20 Amps complete.
S&F in repairs for MCB SP, 240 Volts, AC, 16 amps, breaking capacity 10 KA, 'C' curve complete
M&L in replacement of Plug top, 3 pin, 05 amps, 230 volt.
M&L in replacement of Plug top, 3 pin, 15 amps, 230 volt. (Note: All above items No 1 to 107 for work portions of buildings upto seven storeys height bidder shall quoted the rates according this aspects).
M&L for taking down carefully storge type water cooler of any type/make, capacity (40/80 ltrs, 60/120 ltrs) incl discoonection of electric/water supply connections from various locations, servicing with washing, removing of dust particles,cleaning of condenser coil by blower,painting the outer body (including replacement of corroded sheet with new one) writing letters mentioning the MES Ser No,checking of complete wiring , tightening of loose wire connections with proper Lugs / clips. renewal of defective wiring and connector terminal , proper setting of the thermostat and other electrical / Refrigerant controls and refixing to its original position, testing for proper functioning / cooling effect complete all as specified and directed.
M&L for taking down carefully Refrigerator/Deep freezer of any type/make, capacity (165/185/310/320 Ltrs) incl discoonection of electric supply connections from various locations, servicing with washing, removing of dust particles,cleaning of condenser coil by blower,painting the outer body (including replacement of corroded sheet with new one) writing letters mentioning the MES Ser No,checking of complete wiring , tightening of loose wire connections with proper Lugs / clips. renewal of defective wiring and connector terminal , proper setting of the thermostat and other electrical / Refrigerant controls and refixing to its original position, testing for proper functioning / cooling effect complete all as specified and directed.
S&F in replacement of starting capacitor/running capacitor, suitable range, 240 volt including making connection complete all as directed.
S&F in replacement of relays suitable for water cooler/freezer all as directed .
S&F in repairs for overload protection coil 230 Volts for any type water cooler/freezer, ISI marked complete all as specified and directed.
S&F in replacement of thermostate switch of suitable temperature range ISI marked suitable for water cooler/freezer of any make/type complete.
M&L for charging of refrigerant R-22 / R-410A or any other recommended refrigerant gas in water cooler/freezer/Refrigerator including detecting leakage and rectify the leakage with proper brazing and testing on full load complete all as directed.
S&F for replacement of capillary tube and stainer for any type freezer/water cooler of capacity.
M&L for replacement of hermatically sealed reciprocating/rotary type (as per existing) compressor unit, incl taking down UNSV complete for watercooler/freezer with charging of refrigerant.
S&F in repairs for Printed Circuit Board for control unit for any type,Model suitable for water cooler/ freezer /Refrigerator as per existing and same make ISI marked, incl taking down UNSV complete all as specified and directed.
M&L for replacement of fan blower motor copper wound for water cooler/freezer with same rating 220/230 volts,incl taking down UNSV complete.
S&F for push type water tap made of CP brass suitable for water cooler capacity 80/150 ltrs capacity including taking out old unserviceable tap.
S&F for 60 cm long PVC connector including taking out old unserviceable PVC connector.
S&F for CP angular stop cock with wall flange including taking out old unserviceable stop cock.
S&F for drain tray for water cooler of any capacity including taking out unserviceable drain tray.
S&F for head cover gasket for water cooler of any capacity including taking out unserviceable head cover gasket.
S&F for drain pipe flexible type of existing dia meter for water cooler of any capacity including taking out unserviceable drain pipe.
S&F for magnetic door gasket screw for refrigerator of any capacity including taking out unsv one.
S&F in replacement of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 2 KVA complete.
Supply and fixing in repair of desert/Air cooler 25"x25"x32" body made out of 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit 145 watt ISI marked 1400 RPM , 230 volt AC and tank capacity not less than 100 ltr fitted in existing window with 6mm thick plywood to cover the gap and old UNSV desert cooler deposited in E/M Store yard .
M&L for painting of desert coolers with synthetic enamel paint of approved colour, with spraying machine, after cleaning, scrabing, preparation of cooler body with set of blades,inner/outer surface area complete all as specified and directed.
S&F in replacement of cooler fan motor kit for desert coolers of capacity 500mm sweep, 220-240 Volts,1Ph,145 Watts, 1400 RPM incl fixing arrangement with claming/bracing supports complete all as specified and directed.
S&F in repairs plastic submersible pump suitable for 18 to 22 inch, 18 watt, 240 volts for desert coolers complete all as specified. As per sample.
Supply and fixing in replacement 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for passing air of desert cooler.
S&F in replacement of desert cooler pad (set of three) made out of wood wool etc suitable for desert cooler of any size.
S&F in replacement desert coolers side panels of size suitable of cooler body size (25"x25"x32") made out of 20 SWG MS sheet with wiremesh frame complete and grill duly painted with two coat synthetic enameled paint over one coat of red oxide inside complete all as directed.
S&F in replacement PVC flexible pipe of high density for 15 mm bore with necessary pvc bends,straights complete for desert cooler of any size all as directed.
M&L in replacement of Plug top, 3 pin, 05 amps, 230 volt.
M&L for cooler fan blade (metal body) suitable for 500mm sweep for cooler fan complete all as directed. (Make as per sample)
Rewinding of burnt winding of the cooler fan up to 500 mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed.
All as per item No 138 above item but Hard/dense soil.
All as per No 138 above item but Soft/disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed.
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx l80mm x 40mm , as specified and directed
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked,size of 185 sqmm 3 core suitable for HT 11 KV(E) system, laid in trenches,fixed to pole/wall incl taking down unsv complete all as specified nd directed. Note :- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately.
All as per above item No 146 but size 120 sqmm 3 core
All as per above item No 146 but size 95 sqmm 3 core
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors 10 sqmm 2 core laid in trenches, fixed to pole/wall incl taking down unsv complete any size,type&core complete all as specified and directed. Note:- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately.
All as per above item but 16 Sqmm 3.5/4 Core.
All as per above item but 25 Sqmm 3.5/4 Core.
All as per above item but 35 Sqmm 3.5 Core.
All as per above item but 50 Sqmm 3.5 Core.
All as per above item but 70 Sqmm 3.5 Core.
All as per above item but 95 Sqmm 3.5 Core.
All as per above item but 120 Sqmm 3.5 Core.
All as per above item but 150 Sqmm 3.5 Core.
All as per above item but 185 Sqmm 3.5 Core.
All as per above item but 100 Sqmm single Core.
Laying only (Re routing) serviceable any type of cable up to 70 sqmm 2/3/ 3 ½ /4 core size all as specified and directed. (Note:- Excavation, sand, bricks and connected items shell be measured and paid separately).
All as per item No 149 above but 95 sqmm to 185 sqmm.
Laying only old bricks over the sand cushioning dry and flat for cable protection. (Note:- Bricks obtained from the removing of UNSV cable and re routing cable)
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) Excavation,earth work,cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (d) Material and labour for emergency maintenance work of HT/LT cable line during breakdown by deploying skilled labour and electricians at faulty site having gang of minimum 4 persons including transportation and other tools and plant required at site for fault rectification.(e) Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of breakdown and start attending breakdown within two hours, a penalty of Rs 600 per fault per hour shall be imposed over contractor and shall be deduct from his dues.
All as per item No 151 above but 1100 Volt LT cables
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks/PCC cable cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item No 153 above but 11000 Volt HT cables
S&F, testing and commissioning of air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulators and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements, flat iron clamp 50mm x 6mm incl MS channels of suitable size and length for fixing of gang operatimg device incl bolts,nuts and eashers incl jumper connection with copper flexible strip designed jumper incl taking down unsv complete all as specified and directed.
S&F, testing and commissioning of HT lightening arrester metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements, transmission class discharge capacity 65 kilo amps suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to earth wire 4mm dia GI with manufacturers test certificate, incl taking down unsv complete all as specified & directed.
Material and labour for disconnecting faulty/burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals with suitable size of thimbles and cable glands for Panel Boards for 25 Sqmm 3.5/4 core to 70 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade incl taking down unsv complete all as directed for the following sizes :-
16-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -240 Sqmm x 3.5 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 300 sqmm XLPE armoured aluminium conductor cable incl taking down unsv complete all as specified and directed.
All as per item No 159 above but out door termination complete.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 300 sqmm XLPE armoured aluminium conductor cable incl taking down unsv complete all as specified and directed.
M&L for painting of transformer of capacity 200 to 500 KVA with synthetic enamel paint (Two coats) of existing colour, with spraying machine, after cleaning, scrabing, preparation of outer surface of transformer including writing of SM No, MES and capacity of transformer complete all as specified and directed.
S&F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 200 to 500 KVA complete all as specified and directed.
S&F in repairs for temperature gauge for transformers 0-100 degree celsius complete all as specified and directed.
M&L for ON load centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration achieve dielectric strength 50-60 KV complete all as specified and directed. Note :- 1. Deficient quantity of Transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule. 2. Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor.
Supply & filling new transformer oil of having dielectric strenght 60 KV to top up level complete all as specified and directed
S&F in repair LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 500 KVA complete
S&F in repair HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 500 KVA complete
M & L for Hardcore of gauge n exc. 40 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M & L in repairs for duct cover Mild steel plates, chequered, 5mm thick in Fe 410-W (Gde E-250) quality-A with welding including lifting arengment of duct cover complet all as specified and directed.
Shifing and relocating of transformer in AOR upto 300 KVA capacity pole/plinth mounted indoor/outdoor type incl removing and refixing necessary cable connections complete all as specified and directed. Note: (i) Necesary T&P complete shall be arranged by the contractor. (ii) During shiting process damage any exist infrastructure the same is make good by his own cost.
S&F in repairs for 4 mm dia MS wire 75x75mm mesh, made upto into mattress or cages approx 2.0 mtr height and fixed with flate iron/angle by welding in position and directed complete all as specified and directed. Note:- MS angle, MS flats, Nuts, Bolts and washer will be measured and paid separatly under relevant items.
M & L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.
M&L in repiairs for MS work of angle iron channels and iron flats for post and struts of fencing around transformer plinth etc drilling holes, flat iron for securing wire mesh by welding to angle iron frame and framed work as in door/ gate of angle and wire mesh door to be fixed by 02 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed.
M&L in repairs for Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:4 complete as specified and directed
M&L in repairs for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete all as specified and directed including
Material and labour in repairs for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, floors, foundation and paving etc complete all as specified and directed .
Servicing of ACBs by taking out Air circuit breaks of capacity 400-1250 amps from LT panels cleaning all parts internally and externally checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contract, floating contacts, servicing of motor, and charging system and re-fixing it on its original position and testing including testing of control wiring of the respective ACBs by the authorised service engineer and shall submit necessary certificate for the same all as specified.
S & F in repairs of shutter assembly suitable for 3 pole ACB upto 800 amps capacity complete with all accessories all as specified.
S & F in repairs of arc chute (set of 3) suitble for 3 pole ACB up to 800 Amps capacity complete with all accessories all as specified.
S & F in repairs of floating isolating contacts (set of 3) suitable for 3 pole ACB upto 800 Amps capacity complete with all accessories all as specified.
Material and labour for servicing /testing of breaker/control panel of VCBs/RMUs including CT, PT and relays in control panel of of capacity 630 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required .(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish .(xv) Replacement of Dashpot/shock absorbers .(xvi) Replacement of carbon brush of spring charging motor (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay : - (i) Over current and earth fault relay (d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Master trip relay Note:- Spares shall be measured and paid separately as catered in under respective items
Isolate contact assembly
Auxilary switch
Earth contact assembly
Closing push button
Tripping push button
Spring charged indicator
ON/OFF indicator
Plug & socket assembly
Phase barrier (Set of 02 Nos with nuts & bolts)
Flexible copper connector
Support insulator suitable for ABB Vmax model VCB
Manual spring charging handle
Tripping coil assembly
Closing coil assembly
Limit switch
Shutter assembly
Opening lever for circuit breaker racking in/out
Vacuum interrupter suitable for 630 amps 11 KV HT VCB,
S&F in repairs of heater suitable for 11 KV HT panel all as specified. Make: As per sample
S&F in repairs of thermostat suitable for 11 KV HT panel all as specified. Make: As per sample
S & F in repairs of LED Lamp as per colour scheme suitable for 110 volt DC supply for mounting on HT Panel all as specified. Make: As per sample
S & F in repairs of digital electronic three phase earth fault and over current relay panel mounting type, 3 phase,110 V ( L-L ), MC61A model of L&T, including necessary connection/modification with suitable and including copper cable and other connected accessories for mounting on existing HT panel, Cat pt No.MC61ANX2200 of L&T /C&S or Equivalent.
S & F in repairs of power pack unit suitable for 220 volts AC input & 110 volts DC output complete with 12 volts, 7 Ah sealed lead acid batteries and suitable ammeter, voltmeter, switches etc suitable for operation of HT Panel all as specified and directed. Make: MMAXPOWER & Power Pack or equivalent.
S & F in repairs of 2X12V DC battery with Battery charger with suitable burden for motor operation with input voltage of 230 V AC and out put voltage of 24 V DC
S & F in repairs of digital Trivector meter for 11 KV HT Panel mounting type including necessary connection/modification with suitable and including copper cable and other connected accessories for mounting on existing HT panel. Make Conzerve EM 6400 or equivallant
S & F in repairs of TNC switch suitable for operation of VCB 630 amp of ABB V max model make installed in HT panel 11 KV all as specified. Make - as per sample
S & F in repairs of 11KV fuse tubular type, 11KV/1A suitable for operation of HT Panel all as specified and directed. Make: as per sample
S & F in repairs of spout insulator/cable boots suitable for 630 amps HT VCB of ABB V max model make installed in 11 KV HT panel all as specified.
S & F in repairs of motor gear assembly, suitable for ABB V max complete with necessary wiring and accessories all as specified and directed.
Disconnection of all electric connection & taking out old/defective Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, epoxy cast, 11000 Volts, 50 Hz, ratio 200-100/5A suitable for operation of HT Panel all as specified and directed. Make: STI or equivallent
All as per item No 194 above but 60-30/5A amps complete.
Checking the existing pressure of SF6 Gas in Gas Chamber of 11 KV , upto 630 Amps RMU before filling and rectifying any leackage and topping up the SF6 gas in the chamber of RMU including supervision of gas filling/topping up process and checking the pressure of gas after filling complete all as directed at site.(Note: SF6 gas will be measured and paid separately.)
Supply and filling SF6 gas cylinder complete all as directed.
Labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Labour for trimming of tree branches around the street/security light poles (not less than 2 mtrs) to clear the vegetation including cleaning of nest of birds, creepers on poles and stays etc complete removing and disposed off from the site complete all as specified and directed.
Supply and laying in replacement of synthatic insulating mat of size 2m x 1m x 12 mm all as specified and directed.
All as per above item but size 2m x 1m x 25 mm.
M & L in repair for PCC root indicator made of PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate suitable for mounting on root of HT cable of width 45cm, depth 10cm & height 100cm overall embedded to the depth not less than 45cm below ground level complete all as specified & directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme complete all as specified and directed.
Removal of UNSV PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole steal/PCC with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole with fittings etc complete.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items).Complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed.
M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, for coping, filling and mass concrete with cement plastering finishing all as specified and directed.
M&L for painting of LT electric pole, steel tubular swaged pole (9 mtr long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto to 1.50 mtr length, 1.50 mtr height of PCC coping) alternatively including numbering the pole serially all as directed .
M&L for painting of LT RCC electric pole, (11 mtr long) of any size pattern with one coat of weather proof acrylic synthetic paint and marking the pole with black and yellow strip (upto to 1.50 mtr length from ground) alternatively including numbering the pole serially all as directed .
M&L for two coats of synthetic enamel paint on plastered surfaces as specified colours including printing coat complete all as specified and directed.
M&L for high intensity retro reflective sheet 5cm width length up to 60 cm length as specified colours with heavy duty self adhesive tape for stick on electrical pole complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique with out disturbing top surface of the road and necessary machine including HDPE pipe of 100 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed. Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost.
M & L for Cutting of road/path up to depth 30cm for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
M & L for steel tubes, light grade galvanised 100 mm bore laid in trenches/walls and spreading for cable cushioning/protection all as specified and directed incl taking down old unsv complete.
All as per item No 214 above but 80 mm bore.
All as per item No 214 above but 50 mm bore.
All as per item No 214 above but 32 mm bore.
Material & Labour for repairs of cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified and directed.
M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one all as directed and specified .
M&L for repairs in PVC, sheathed copper cable of 2.5 sqmm, 3 core for street light connection including taking down unserviceable PVC insulated aluminium conductor cable from steel pole /PCC pole /Jn box all as specified and directed.
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 25 Watt including taking down old unserviceable one all specified and directed.
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt including taking down old unserviceable one all specified and directed
S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 60 Watt including taking down old unserviceable one all specified and directed .
S&F in repairs for large area flood lighting system LED type IP 66, pressure die cast housing, with heat resistant tempered glass for protection with surge protection system, 120 Watt including taking down old unserviceable one all specified and directed.
S&F in repairs for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specified and directed. (Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items)
S&F in repairs for garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution including taking down old fitting, demoliton of brick/PCC work all as specified and directed. (Make :Crompton LBLSN 10 CDL or equivallant in Havells/Philips) (Note: Necessary PCC works shall be measured and paid separately under relevant items)
Taking down defective street light fitting/flood lights any wattage, make,model from pole and repair the same including replacement of defective/faulty LED driver and re-fixing the same incl connection complete all as directed
S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed.
S&F in repairs for decorative LED post top/garden light fittings with all accessories complete along with after taking down old unserviceable one all specified and directed. Model as per sample (Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items)
S&F in repairs for loop box out door type made out of Engineering plastic one piece moulding type,Bus bar rating 63 Amps 4 strips aluminium with bus bar mounting colour R,Y,B,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardant size 300x 200x 100mm with 10 Amps MCB SP, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, all as specified and directed. (Note:- Incoming and outgoing cables suitable size Lugs,Glands rate deemed to be included)
All as per item No 227 above but Single phase system 2 strips aluminium bus bar size of 200x150x100mm all as specified and directed.
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing feeder piller, removal of complete LT feeder piller with necessary T&P, breaking of plinth, shifting and fixing of same feeder piller at new location including necessary eath work and PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) work as directed and connecting of incoming and outgoing cables, inclusive of two coats synthetic enamel paint of existing colour over one coat of primer, incl testing & commissioning etc., complete all as directed. Note: The cost of Aluminium thimbles/lugs and cable gland etc., as reqd at site is included in quoted rate.
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller of any size and any type, powder coated painting in inner & outer side complete over a cleaning, scrabing with salt paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing complete all as specified and directed.
M&L for replacement of lock assembly with key of old/existing LT panel board any type/size complete all as directed
M&L for replacement of door/MS sheet of old/existing LT panel board any type/size with cutting, welding & bend to shape and spray painting with powder coated paint with smoke grey paint in outer/inner side over one coat of primer after complete all as directed
M & L for repair/overhauling of old LT panel board of any size/type, cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning and preparing surface incl sign writing complete all as directed
M&L for replacment of double compression stainless steel gland for power cables incl remove and restore of electric connection complete all as directed of following sizes :-
Size suitable for 16/25 sqmm 3.5/4 core LT cable
Size suitable for 35 to 50 sqmm 3.5 core LT cable
Size suitable for 70 to 120 sqmm 3.5 core LT cable
Size suitable for 150/185 sqmm 3.5 core LT cable
S&F in replacement MCB, DP, 415 volts AC, 40 amps,10kA all as specified and directed.
S&F in replacement MCB, DP, 415 volts AC, 63 amps,10kA all as specified and directed.
S&F in replacement MCB, FP, 415 volts AC, 40 amps, 10kA all as specified and directed.
S&F in replacement MCB, TP, 415 volts AC, 40 amps, 10kA all as specified and directed.
S&Fin replacement MCB,SP,240 volts ,AC, 6 to 32 amps, 10kA all as specified and directed.
S&F in repairs for MCB 40 amps FP with 30 mA, 10 KA, ELCB,IP 20, Dual on position DIN clip type with fixing arrangements in exist TPN DBs complete all as specified.
S & F in replacement of MCCB, 4 pole, 415V AC, fixed type of following capacity:
63Amps with breaking capacity 16kA
100 Amps with breaking capacity 16kA
125Amps with breaking capacity 16kA
160 Amps with breaking capacity 25kA
200Amps with breaking capacity 25kA
250 Amps with breaking capacity 35kA
400Amps with breaking capacity 36kA
S & F in replacement of MCCB, three pole, 415V AC, fixed type of following capacity;
100Amps with breaking capacity 16kA
125Amps with breaking capacity 16kA
200Amps with breaking capacity 36kA
300Amps with breaking capacity 36kA
S & F in replacement of onload changeover switch, four pole, 415V AC,of following capacity;
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing feeder piller, removal of complete LT feeder piller with necessary T&P, breaking of plinth, shifting and fixing of same feeder piller at new location including necessary eath work and PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) work as directed and connecting of incoming and outgoing cables, inclusive of two coats synthetic enamel paint of existing colour over one coat of primer, incl testing & commissioning etc., complete all as directed. Note: The cost of Aluminium thimbles/lugs and cable gland etc., as reqd at site is included in quoted rate.
M&L for PVC, sheathed Aluminium conductor cable of 6 sqmm, 2 core for electric poles to bldgs connection including taking down unserviceable PVC insulated aluminium conductor cable from Poles /Jn box all as specified and directed.
M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller indoor/out door type, powder coated painting over a cleaning, scrabing with salt paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing.
S & F in repairs of LT panel Voltmeter digital type for 415 Volts, 3 phase system, rating 0-500 V complete suitable for operation of LT Panel all as specified and directed.
S & F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-200 A complete suitable for operation of LT Panel all as specified and directed.
S & F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-400 A complete suitable for operation of LT Panel all as specified and directed.
Supply only earth/ discharge rod suitable for 11 KV, single phase, highly insulated, FRP material, Telescopic type, smooth & glossy surface, push button type locking system, total 3 section, assembled length not less than 15 feet, top section dia not less than 25mm & bottom section dia not less than 45 mm, die cast aluminium earthing instrument for 30 mm dia, incl 6 sqmm copper cable not less than 06 mtr long, crocodile grouting clamp with cover complete all as specified & directed.
S&F in repairs for informatory/eqpt history sign boards of size not less than 900 x 600 mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame, back ground and epqt history details(i.e. Name, Make, Ser No,Capacity of eqpt, Vintage, SM/MES No etc.,) with high intensity retro reflective sheet letters as specified colours (blue and white) complete all as specified and directed.
S&F in repairs for fire Extinguisher CO2 (ABC type) maximum capacity of 4.5 Kg. as per the IS 2878 complete all as specified and directed.
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of size 25 X 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and as directed.
Material & labour for earthing with Copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper strip of size 20X3 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) including testing on completion if desired earth resistance is not obtained the earthing will be redone without extra cost complete all as specified and directed.
Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 20x3mm copper strip all as specified and directed.
S & F earth continuity conuctor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 4mm dia galvanised iron wire. All as per specified and directed.
Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 25x4mm GI strip all as specified and directed.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - 115434.50
NEETU TRADERS (INDIA)
NEERU ELECTRICALS
M/s Prakash Enterprises
AMIT BROTHERS
S S CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .