Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹33.1 L+₹8,584 (0.26%)Rejected-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹33.2 L+₹24,365 (0.74%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹38.8 L+₹5.8 L (17.6%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO NO REMARK IN WLR |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
14 Sept 2021, 6:00 pmClosed
GE (NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
M AND O OF WATER SUPPLY INSTALLATIONS, DG SETS AND REPAIRS TO STREET LIGHT /WATER SUPPLY AT KV AND DAD COMPLEX ,M AND O OF WATER SUPPLY INSTALLATIONS AT P 269 AND P271 (TYPE III AND IV at EAST CAMP ) UNDER GE NW BHANDUP
2021_MES_458045_2
8135/B
Open Tender
Civil Works
Item Rate
335 days
POWAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NW BHANDUP
₹94,000
Yes
4 Apr 2022
24 Aug 2021
15 Sept 2021
24 Aug 2021
14 Sept 2021
31 Aug 2021
Amount
Manning & Operation of water supply installation including sundays and holidays, including electric panel board, operating underground sump control valves etc for 16 hrs daily in two shifts from 0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs in KV staff Qtrs Bhandup by providing one operator per shift complete all as specified and directed to operate the following on as required basis. (a), Pumping set monoblock 20 HP - 02 Nos (b) DG set 45 KVA as and when required -01 No Note : While manning pump set and generator the operator will attend to minor repairs like replacement of fuses, replacement of filters,oil,tightning of bolts,nuts,arresting leakages etc for which the labour rates are deemed to be included in the quoted rate. (c ) Contractor should provide all necessary stationery for records.
Cleaning of underground sump by draining pumping out water/sludge from bottom by blocking all pipes against choking removing algae and growths from wall/floors/roof high pressure cleaning method with rotary sets with chemical treatement (Chemical approved by FOA/WHO) to make the sump clean and bacteria free of capacity of sumps 50,000 gallons and including disposal outside MD land all as specified and directed. (Note : Tank cleaning once in a six months and quoted rate is deemed fit for one time cleaning only)
Material and labour for servicing and overhauling of dynamo/alternator including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Supply and fixing in repacement of CI foot valve flange type of following size of 150 mm dia complete all as specified
Supply and fix in repair sluice valve of size 80 mm with cast iron body wedge stuffing box gland thrust plate hand wheel of grey cast iron spindle of stainless steel nut body seal ring and wedge facing gasket of comprised fibre bolts glands packing of jute and hump flanged drilled type nominal pressure rating PN- 1.0 and conforming to IS-780 of 1980 complete all as specified and directed.
S&F in repairs ball valve complete with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixing of size 40 mm dia completeall as specified and directed.
S&F in repairs GI tubing medium grade ISI marked including all fittings laid in trenches / fixed on wall of size 50 mm bore all as specified and directed.
S&F in replacement contactor 32/35 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 Hz complete all as specified and directed.
S&F in replacement thermal over load relay of range 24 to 34 Amps complete all as specified and directed.
S&F in replacement digital Voltmeter digital type (0-500V) complete all as specified and directed
S&F in replacement digital Ammeter digital type (0- 100 Amps) complete all as specified and directed
S&F in repairs Star Detla Timer 0-30 Seconds duration all as specified and directed.
Supply and fix MCCB 100 Amps 4 Pole, with breaking capacity 16 KA complete all as specified and directed.
Taking out the unseviceable CI pipe lines including all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead of size 80mm bore complete all as specified and directed.
Supply and laying of cast iron pipes with spigot and socketed ends centrifugally cast, class 'LA' in any length laid in trenches of size 80mm bore complete all as specified and directed.
M&L in repairs Bends tapers any type, (straight, bend, increasing, decreasing or double socket etc). Tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of CI fittings upto 150 bore complete all as specified and directed.
M&L of run lead joint to CI spigot and socketed pipe of bore 80 mm dia complete all as specified and directed
M&L in repairs of run lead joint to CI spigot and socketed pipe of upto 100 mm dia complete all as specified and directed
Dismantling of monoblock pumpset of 20 HP capacity overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers and replacement of gunmetal bush bearing and gland packing of pump set and reassembling the pumpset and testing and commissioning complete all as specified and directed
Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing complete of capacity 20 HP complete all as specified and directed.
Taking down HPSV / MH street light fitting and Supply and fix LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 6500 lumens with maximum system wattage 60/65W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 110lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters all as specified.
Taking down unserviceable security light fitting and Supply and fixing LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 3000 umens with maximum system wattage 25W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Taking out existing unserviceable FRP terminal box and S&F in repairs mounting type weather proof terminal box of size 150 x 140 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall all as specified and directed.
M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (02 Run of 2.5sqmm and 01 Run of 1.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9 metres long with all connected works including bracket and suitable clamps and complete all as specified and directed
Supply and lay in repairs of cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core complete all as specified and directed.
All as per item No 26 but of size 50 sqmm x3.5 core complete all as specified and directed.
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection complete all as specified and directed.
Cutting of existing road/PCC for laying of LT cables upto 150mm depth complete all as specified and directed
Material and labour for repalcement of un serviceable single phase preventer , 415 V 50Hz including electric connection all as specified and directed by Engineer-in-Charge.
S&F in repairs MS steel work of quality for ladders, stairs, hand rails, including cleats, valve chamber covers, pump set coupling covers, rackets, base plates for pump sets, etc complete ll as specified and as directed
Material and labour for replacement of un serviceable water pressure gauge of dia 100mm of the range 0 to 100 Kg /sqcm complete all as specified and directed.
Supply only stable bleaching powder(calcium hypochlorite with chlorine content not less than 30%) as per IS : 15738:2007 and 1065:1989 complete all as specified and directed.Make:Grasim,Rayalaseema,Bengal chemical & pharmaceuticals.
M & L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized iron strip 32 x 6 mm by means of GI bolts nuts, check nuts and washers etc all as shown in electrical plate No. 3 of SSR part 01 1996 including earth work PCC pit with cover, funnel with watering pipe, wire mesh and GI protection pipe light grade all as specified and directed.
Manning & Operation of water supply installation including sundays and holidays, including electric panel board, operating underground sump control valves etc for 16 hrs daily in two shifts from 0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs in DAD staff Qtrs Powai by providing one operator per shift complete all as specified and directed to operate the following on as required basis. (a) Pumping Set C/F,monoblock 10 HP - 02 Nos (b) Pumping Set C/F,monoblock 7.5 HP - 01 No (c) Generator Set 125 KVA (as and when required) -01 No Note : While manning pump set and generator the operator will attend to minor repairs like replacement of fuses, replacement of filters,oil,tightning of bolts,nuts,arresting leakages etc for which the labour rates are deemed to be included in the quoted rate. (d) Contractor should provide all necessary stationery for records.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets etc, removing materials from site and making good distrubed surface of wall, floors etc all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core in casing caping of suitable size complete with sunken iron pressed steel terminal box 1.6 mm thick for fitting mounting switch/ sockets regulators etc with hylam sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to common earth dolly for One light point controlled by one switch all as specified and directed.
All as per item no.37 but One fan/exhaust fan point controlled by one switch & regulator
All as per item no.37 butOne 5A, 3pin socket outlet with other switch on same board.
All as per item no.37 butOne bell point controlled by one switch
All as per item no.37 but One 2/3 pin switch socket point 5A controlled by switch on independent board
All as per item No 37 above but for 2/3 pin switch socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
Supply and fix switch piano type 5 Amp single pole one way complete all as specified and directed.
Supply and fix ceiling rose surface backelite min dia 63 mm three terminal complete all as specified and directed.
Supply and fix bell push 5 Amp piano type single pole 230 volts one way complete all as specified and directed.
Supply and fix call bell buzzer AC, 230 Volts single pole all as specified and directed.
M&L for socket outlet 2 in 1 3 pin 5 Amps & 2 pin 5 Amps multipurpose flush type. complete all as specified and directed.
Supply and fix switch socket combination multi purpose 5 pin 5 Amp flush type complete all as specified and directed.
Supply and fix switch socket combination multipurpose 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete all as specified and directed.
Supply and fixing ceiling fan regulator step type 230V, all as specified and directed.
Supply and fixing in replacement of electronic choke 36/40 watt complete all as specified and directed
Supply and fixing in replacement of electronic choke 18/20 watt complete all as specified and directed
S&F in repairs of LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x22W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed.
S&F in repairs of LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x12W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed
Taking down MCB DBs SPN any type all as specified and directed
Supply & fix MCB distribution board SPN 08 way double door with bus bar complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volts 5 Amp to 32 Amp breaking capacity 10 KA rating complete all as specified and directed.
Supply and fix in repairs MCB TPN 440 Volts 63 Amp breaking capacity 10 KA rating complete all as specified and directed.
Taking down and opening / dismantling of ceiling fan, cleaning complete, oiling / greasing including replacement of capacitor/worn out parts e.g. bearing, bush, shaft, etc.where necessary, checking for smooth running including cleaning the surface and applying spray painting with one coats of synthetic enamel paint and refixing, testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Spare parts like capacitor, bush and bearing where required to be replaced and it will be measured and paid separately under respective items as supply only
Taking down and opening / dismantling of ceiling fan, 1200/1400 cutting and taking out old unserviceable winding and M & L for rewinding the same with super enamelled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassebling, testing complete including cleaning the surface and applying spray painting with one coats of synthetic enamel paint and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : Spare parts like capacitor, bush and bearing where required to be replaced and it will be measured and paid separately under respective items as supply only
All as per above item No. 61 but exhaust fan 300mm sweep complete all as specified and directed.
Supply only bearing Suitable for existing ceiling fan of 1200/1400mm sweep all as specified and directed
Supply only capacitor 2.5 mfd capacity 230 volts all as specified and directed
Supply only capacitor 4.0 mfd capacity 230 volts all as specified and directed
Supply and fix in repairs of switch piano type 5 Amp single pole one way 230V, complete all as specified and directed.
Supply and fix in repairs of bell push 5 Amp piano type single pole 230 volts one way complete all as specified and directed.
S&F in repairs of switch socket combination multipurpose flush type 5 pin 5 Amps flush type complete all as specified and directed.
Supply and fix in repairs of switch socket combination multi purpose 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete all as specified and directed.
Supply and fix in repairs call bell buzzer AC, 230 Volts single pole all as specified and directed.
Supply and fixing in repairs ceiling fan regulator rotary step type 230V, all as specified and directed.
Supply and fixing in repairs of capacitor 2.5 mfd capacity 230 volts all as specified and directed
Supply and fix in repairs starter 20/40 watt 230V complete all as specified and directed.
Supply and fix in repairs bipin holder spring loaded with contacts complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Supply and spreading sand (Stone crush) in trenches as cushioning to under ground cable on top and bottom of cable complete all as specified and directed.
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and laying in repairs GI pipe 40 mm, light grade for the protection of the cable complete all as specified and directed.
M& L for cement concrete type B-1 1:2:4 using 20 mm graded aggregate for road finishing / foundation etc. complete all as specified and directed.
Taking out existing terminal box and S&F Pole mounting type weather proof FRP terminal box of size 250 x 175 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and aluminium bus bar for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to street light pole with suitable MS iron flat of size 25 x 3 mm clamps fixed with GI Bolts, nuts and washer of suitable sizes all as specified and directed
Taking up or down steel tubing and connections including cleaning for refixing or removal to store of 50mm bore complete all as specified and directed.
All as per above item No.83 but 40mm bore complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (trenchs, walls, ceiling, floors etc) of bore 50mm bore obtained from item No .84 complete all as specified and directed.
S&F of GI tubing medium grade ISI marked including all fittings fixed on wall/ceiling of size 50 mm bore all as specified and directed.
S&F of GI tubing medium grade ISI marked including all fittings fixed on wall/ceiling of size 40 mm bore all as specified and directed.
Supply and fix in repair gun metal gate valve with iron wheel head of size 50 mm with external threaded both ends for connecting to pipeline including all as specified and directed.
Dismantling of monoblock pumpset of 7.5 HP capacity for repairs,taking the same to work shop , replacement of unserviceable spares, reassembling the pumpset including replacement of impeller, gland cap, bush, gasket bearing and testing, commissioning complete all as specified and directed
Dismantling of monoblock pumpset of 10 HP capacity for repairs,taking the same to work shop , replacement of unserviceable spares, reassembling the pumpset including replacement of impeller, gland cap, bush, gasket bearing and testing, commissioning complete all as specified and directed
Dismantling of monoblock pumpset any capacity for repairs,taking the same to work shop , rewinding of electric motor 10 HP 3 phase, 415V, 50Hz with super enameled copper wire of suitable gauge including varnishing, testing and commissioning complete all as specified and directed
Supply and fixing in repairs threarded type gun metal foot valve of 65 mm size all as specified and directed
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level complete all as specified and directed
Cleaning of circular underground sump by draining/pumping out water/sludge from bottom by blocking all pipes against choking removing algae, fungus and other growths from wall / floors / roof by high pressure cleaning method with rotary jets with approved detergents rubbing the walls with vacuum cleaner, sucking out all dirty water and disinfecting the sump with chemical treatment to make the sump clean and bacteria free including painting MS steps manholes covers and suction pipe with synthetic enamel paint, etc, capacity of sump 110000 litres (at DAD quarters) including disposal of waste outside MD land all as specified and directed
M & L in replacement of GI bracket made out of 40mm dia medium grade 1.2 mtr mtr long bend to shape including suitable MS flat iron, clamps and nou blots etc complete all as specfied and directed
Refixing and laying only cast iron pipe of size 80mm with spigot end socketed any class in available length obtained from item No.95 tested complete in trenches all as specified and directed
Material and labour for construction of valve chamber of size 1000 x 1000 x 750 mm (internal diamensions built in brick masonary on 15 cm thick PCC foundaton (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thck hard cor with brick work masonary in cement mortar 1:4 using 'B' class bricks and rendering in cement mortar 1: 4, 10 mm thck internally including exposed surfaces of external surfaces, MS cover made out of 3 mm thick MS sheet on angle iron framework made out of 40 x 40 x 3 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thck PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement & applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by Engineer-in-Charge.
M&L Carrying out 'B' check for 125 KVA DG set all as per manufacturers instructions all as specified & directed. Note :cost includes the rates of diesel filters but excluding spare and engine oil.
Supply only grade 20W 40 Engine oil
Supply only coolant for radiator complete all as specified.
Supply only oil filter suitable for 125 KVA capacity DG set as per existing model complete.
Supply only Air filter for 125 KVA as per existing model complete all as specified and directed
Supply only fan belt suitable for 125 KVA DG set as per existing make complete
Material and labour for disconnecting / dismantling of self starter from DG set 125 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc.. greasing and connecting , testing complete all as specified and as directed.
Material and labour for servicing and overhauling of dynamo including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Dismantling and calibrating the fuel injector assembly of 125 KVA DG set at authorised service centre complete all as specified and directed.
Supply and fixing in repairs of contactor 32 amps capacity 2 NO + 2 NC, AC 3 phase 415 volts 50 Hz suitable for existing model complete all as specified and directed.
Supply and fixing in repairs of thermal over load relay of range 10 to 22 amps complete all as specified and directed.
Supply and fix in repairs of MCCB 100 Amps 3 Pole, with breaking capacity 16 KA complete all as specified and directed.
M & L in replacement of Earthing complete with galvanised steel earth electrode 60Cm x 60Cm x 6 mm thick directly burried in ground ( eath pit not less than 2.25 M deep below the normal ground level conneceted to galvanised earth strip size 25 x 4 mm dia by mens of bolts, nuts, check nuts and washers of galvanised iron steel including necessery excavation earth work PCC chamber CI chamber cover protection pipe watering pipe etc. (Complete all as shown in electrical plate No 3 and conected to earthing test point complete including excavation earthwork, PCC chamber, chamber cover ,funnel watering and protection pipe etc all specified and directed.
S & F in repairs heating element of 1.5 kw / 2.0 kw including rubber washer ISI marked any type complete all as specified and directed.
S&F in repairs thermostat for water stroage heater SP 230V complete
Supply & fix in repairs non return valve 15 mm dia & connecting of complete heavy duty ISI marked complete all as specified & directed
Supply & fix in repairs safety valve / high pressure release valve 15 mm dia ISI marked complete all as specified & directed
Supply & fix in repairs indicator neon lamp 230 volts SP square or round complete all as specified & directed
Supply & fix in repairs chromium plated copper connecting piece with brass adapter 18" long complete all as specified & directed
Supply & fix in repairs PVC connecting piece HP branded with brass adapter 18" long 15 mm dia complete all as specified & directed
Manning & Operation of water supply installation including sundays and holidays, including electric panel board, operating underground sump control valves etc for 24 hrs daily round the clock in three shifts in Type III P/269, P/270 & IV Qtrs P/271 (East Camp Powai) by providing one operator per shift complete all as specified and directed to operate the following on as required basis. (a) Pumping Set 20 HP - 02 Nos (b) Fire pump Electrically operated 100 HP - 01 No (c) Fire Pump Diese Engine Operated - 01 No (d) Jockey pump -01 Nos (e) Generator Set 160 KVA (as and when required) -01 No Note for item No (a) to (e) : While manning pump sets the operator will attend to minor repairs like tightening of bolts, nuts, arresting leakages, pump set gland packing etc, filling of fuels for which the labour rates are deemed to be included in the quoted rate. (c) Contractor should provide all necessary stationery for records. (d) Contractor should record the running hours of pumps in log sheet
Deduct Credit for Demolished/ Dismantled material Rs. (-) 1,34,069.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
ASHA ASSOCIATES
Shree Ayyappa Engineering
Radha Engineering Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .