Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.0 LAccepted-AOC | L1 | Accepted-AOC Quoting Lowest Amount | |
| 2 | L2₹91.4 L+₹2.4 L (2.70%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹91.8 L+₹2.8 L (3.12%)Rejected-Finance | L3 | Rejected-Finance Quoting Higher Rate | |
| 4 | L4₹94.6 L+₹5.6 L (6.32%)Rejected-Finance | L4 | Rejected-Finance Quoting Higher Rate | |
| 5 | Rejected-Technical 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | - | Rejected-Technical Current P.tax challan not found |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
9 Jun 2021, 3:00 pmClosed
Superintending Engineer, Western El
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Up-gradation of Dhaniakhali Rural Hospital from 30 beds to 100 bedded SGH ---- Development of Sub-station, cabling arrangement from sub-station to different load points and External E.l Work/Compound Illumination
2021_WBPWD_331349_1
WBPWD/SEWEC /HED /NIQ-02/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Dhaniakhali
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.7 L
Office of the Superintending Engineer, Western Ele
21 Mar 2022
13 May 2021
11 Jun 2021
13 May 2021
9 Jun 2021
19 May 2021
13 May 2021 - 18 May 2021
18 May 2021
Amount
Supply and delivery of 11 KV 800 A, 350MVA short-circuit capacity of 26.3 KA for 3 sec 3-panel HT Gear with VCBs as per Specification [Make - Schneider Electric/SIEMENS/ABB/ Crompton Greaves/ PASCAL as approved by E.I.C] below :-
The Vacuum Circuit Breaker should comply as per IS:13118 & IEC:62271-100 for Circuit Breaker & IS:3427 & IEC:62271-200/IEC 694, IEC-61850 for Indoor panel.
PANEL The HT panel is rated at 11 KV, 3-Phase 800A, Breaking Current/short-circuit capacity of 26.3kA for 3 sec, 50c/s and shall be of floor-mounting, sheet steel clad, free-standing metal enclosed air insulated switchgear cubicle with VCB inside. The Vacuum Circuit Breaker (make- Schneider Electric/SIEMENS/ABB/ Crompton Greaves) is horizantal isolation & horizantal drawout/Vertical isolation & horizontal drawout with 4 compartments and is made of 2mm/2.5mm CRCA sheet for load bearing members with vermin & moisture proof along with automatic shutter arrangement for complete isolation of bars, cable sockets & other live parts etc. when the removable portion is withdrawn. The breaker is arranged for hand operation through front of the panel push buttons & spring charging mechanism and also electrical motor which will be energizied by 230V AC. Closing and tripping coils are rated for 110V DC to be made available from the station 400 V 3 phase 50 C/s A.C. source with remote operation compatibility. All trip coils shall be of shunt trip type energized from a suitable rectifier condenser source.supply is required. There is a remote operation through multicore arrangement for closing & tripping. The shutter shall be gravity operated.
Front Door The front door of the breaker seting as panel door is not acceptable. High-Voltage door During switching operations, the high-voltage door should remain closed and mechanical interlock should prevent opening of door when the switching device is in service and is switched ON. The position of the withdraw-able section, the CLOSED/OPEN switch position of the switching device, the operating cycle counter and the “spring charged” indication should be visible through pressure-resistant inspection windows in the high-voltage door. The panel front door can be closed with the breaker in isolated position. The degree of protection in the panel is IP-4X as per Indian Standard IS 3427.
BUSBAR The spacious bus bar compartment is provided on the top of the cubicle. The main bus bar can carry current upto 1000A and are made of electrolytic grade copper & shall be vertically placed one after another. The bus bars should be air insulated but must be HT PVC sleeved & color coded for R-Y-B. No live parts should be accessible. All joints should be covered with monoplast compound and color coded for easy identification. The feeder connection to the busbars are preffered to be encapsulated.
BREAKER The vacuum circuit breaker is mounted on a truck and is of horizontal isolation and horizontal drawout/Vertical isolation & horizontal drawout type having a robust motorized mechanism. The spring charge cycle duty of mechanism is O-C-O. The vacuum circuit breaker is single break design and have one vacuum interrupter per phase. The vacuum interrupter should not be of pinch tube type design, it should be sealed by brazing in a vacuum oven & all the vacuum interrupters must be segregated in a cast resin housing. The minimum operational life of the vacuum interrupter is 30,000 mechanical, 10,000 electrical at rated current & 100 at rated short circuit. The breaker is having auxiliary switch 6NO+6NC.
EARTHING A continous copper earth bus runs across the entire length of the switchboard. All doors partitions, covers and non current carrying metallic parts are earthed to achieve earth potential for the entire enclosure. Terminals are provided at each end of the earth bus to connect the grid earthing. If integral earthing facility is not available separate earthing truck shall be provided for earthing.
INTERLOCK The circuit breaker can be operated only in service/test position and not in any intermediate position, beside fully isolated condition.The circuit breaker cannot be inserted into service position in closed condition and cannot be removed from service unless it is in open condition. The circuit breaker cannot be moved from test position to service position unless auxiliary plug is engaged and auxiliary plug cannot be disengaged if the breaker is in service position. If earth switch is provided it shall be mechanically interlocked with the breaker so that both the devices can not be 'ON' simultaneously.
CURRENT TRANSFORMER The current transformer should be tape wound type fastened on a cast resin bar primary for primary current rating as specified to facilitate easy replacement in case of an unforeseen damage during service. Cast resin encapsulated current transformer below 200A CT with multicore arrangement is acceptable. Metering core should be of class 1.0 & protection core shall be of class 5P10. The CTshould have at least 25% over capacity than total connected load. The CT should be capable to withstand the rated full short circuit current for minimum 1 second.
POTENTIAL TRANSFORMER The potential transformer is drawout type with HRC fuses provided in both the sides of primary & secondary. There should be provision for replacing the primary fuse in a line connected PT when the circuit is in live condition. Hence line connected PT mounted in a breaker carriage is not acceptable. The PT shall be cast resin moulded & insulated type encapsulated & 3- phase type with Y-Y connection. It should be of class 1.0 with over-voltage factor 1.2 conntinuous for a solidly grounded system. For PT unearthed system should be rated for the over-voltage factor of 1.9 for 8 hours. P.T is in the VCB chamber truck.
METER The indicating meters are of digital type & 96x96 sq.mm.
Digital Multi Function Meter.
RELAYS Combined Numerical Relay of SCADA-compatability with following protection function:-50, 50N, 51, 51N, 37, 46, 46BC, 49, 50BF, 64N, 68, 86 and 95
Master Trip Relay
INDICATION Blue/White Indicating lamps for ON / OFF /TRIP /SPRING CHARGE /TRIP CKT HEALTHY indication in the panel.
TESTING The fully assembled switch board shall be offered for routine testing as per provision of IS standards mentioned above. The manufacturer should submit closing & tripping time curve after testing on a breaker analyzer. For major boughtout components like CT, PT, meters & relays the routine test certificates of the respective manufacturers need to be submitted.
THREE PANEL VCB COMPRISES OF :
(A) 1 No Incomer Panel equipped with 800A Vacuum Circuit Breaker with the following accessories:
a) 3 Phase 3 limb draw type line PT 11KV/RT3 /110V/RT3, 200VA Cl - 1 with fuses for primary & secondary circuit - 1 no.
b) Epoxy Cast, Dual Core CT having CT ratio 60-30/5+5 with CORE1:15VA, Class -1.0 CORE2:15VA, Class - 5P10, STC - 25ka for 1 sec- 3 nos.
c) Shunt Trip Coil of 110V DC- 1 no.
d) LED type indicatiing lamp for VCB ON/OFF, CB Trip, Springe Charge, Trip Ckt Healthy- 5 nos.
e) LED type RYB Phase indication lamps-- 1 set
f) Cubicle Panel illumination lamp.- 1 set
g) Push Button for Emergency Trip- 1 no.
k) Digital Multi Function Meter- 1 no.
l) Combined Numerical Relay of SCADA-compatability incl. providing necessary software with following protection function:-50, 50N, 51, 51N, 37, 46, 46BC, 49, 50BF, 64N, 68, 86 and 95 with programmble in-built LED indicating lamp --- 1 set.
m) Master Trip Relay Type VAJH13- 1 no.
n) Trip circuit Supervision relay type-VAX31 --- 1 no. o) Antipumping relay -- 1 no. p) 6/8 Window Annunciator -- 1 set
q) Local Remote/T-N-C/Motor On-Off/Heater On-Off Switch- 4 set.
r) MCB for control supply-AC/DC -- 2 sets
s) HRC control fuse & link as per scheme-- 1 set t) 110V DC Hooter- 1 no.
u) Power Pack with capacitor back-up for 110V DC control supply for Closing & Tripping Coil, Relays, Indication Lamps- 1 no. Power pack to be fed from the secondary side of the Potential Transformer.
w) Panel space heater with thermostat-- 1 no.
x) Panel Illumination lamp - 1no.
(B) 2 Nos outgoing panel equipped with 800A vacuum Circuit Breaker with following accessories:
a) Epoxy Cast, Dual Core CT having CT ratio 50-25/5+5 with CORE1:15VA, Class -1.0 CORE2:15VA, Class - 5P10, STC - 25ka for 1 sec- 3 nos.
b) Shunt Trip Coil of 110V DC- 1 no.
c) LED type indicatiing lamp for VCB ON/OFF, CB Trip, Spring Charge, Trip Ckt Healthy- 5 nos.
d) LED type RYB Phase indication lamps-- 1 set
e) Cubicle Panel illumination lamp.- 1 set
f) Push Button for Emergency Trip- 1 no.
h) Digital Multi Function Meter- 1 no.
i)Combined Numerical Relay of SCADA-compatability with following ptotection function:-50, 50N, 51, 51N, 37, 46, 46BC, 49, 50BF, 64N, 68, 86 and 95with programmble in-built LED indicating lamp --- 1 set.
j) Master Trip Relay Type VAJH13- 1 no.
k) Undervoltage Relay type VDG13 -- 1 no. l) Trip circuit Supervision relay type-VAX31 --- 1 no. m) Auxiliary relay for Transformer (BUCHz/OTI/WTI ALARM and TRIP)- VAA33 Wdg. temp. A/T indication ---- 2 no. n) Antipumping relay -- 1 no. o) 6/8 Window Annunciator -- 1 set
p) Local Remote/T-N-C/Motor On-Off/Heater On-Off Switch- 4 set.
q) MCB for control supply-AC/DC -- 2 sets
r) HRC control fuse & link as per scheme-- 1 set s) 110V DC Hooter- 1 no.
t) Panel space heater with thermostat-- 1 no.
u) Panel Illumination lamp - 1no.
Supply,and Delevery of 11KV/415V, Dyn11, 315 KVA three-phase Cast Resin dry type Indoor Power Transformer with CPRI approved – AN cooling as per IEC 60076-11/ IS 11171 with latest amendment. The Transformer will be of environmental class of minimum E2, climatic class- C1 & Fire behavior class- F1 as defined in IEC 60076 and the same will be indicated on the rating plate. Links / Tappings:- Off circuit Links, tapping range +5% to -5% in steps of 2.5% Tap position. configuration diagram shall be provided. ( Make: Raychem RPG/Voltamp (Baroda ) /Universal Power Transformer Pvt. Ltd./ABB/Crompton Greaves as approved by E.I.C)
Rating:- 315 KVA, 3 phase, 50Hz, Delta / Star Type:- Cast Resin type (CRT), three phase, copper wound, air cooled dry type. Voltage ratio:- 11000V / 415 Volt Rated frequency:-50 Hz Rated primary voltage:- 11kV Rated primary insulation level:- 12kV Basic Impulse Level (BIL):- 75kVp Links/Tappings:- Off circuit Links, tapping range +5% to -5% in steps of 2.5% Tap position configuration diagram shall be provided. Cooling:- Air Natural (AN) Painting:- As per IS 5 (Painted with synthetic enamel) Vector Group:- Dyn 11 Class of Insulation:- Class F
The core and coil assembly shall be securely fixed in position so that no shifting or deformation occurs during movement of transformer or under short circuit stresses. Efficiency (Minimum):- a) At Unity PF (i) 98.82% at full load (ii) 98.98% at 75% load (iii) 99.08% at 50% load Maximum Efficiency:- 99.8% at 48.12% i.e. 230 KVA Transformer losses should be maintained as per latest ECBC guidelines. Maximum allowable Total losses should be 1100W at 50% load and 3275W at 100% load. Transformer losses shall be guaranteed such that actual value does not exceed guaranteed value beyond the said allowable value, otherwise the transformer will be rejected. The purchaser, at this direction, may send the equipment at CPRI/Govt. laboratories, to check the actual loss, if they so desire. All the test charges will have to be borne by the supplier.
Maximum ambient temperature 50 °C Temp. rise:- 90° C over ambient of 50°C Secondary voltage at no load - between phases 433V % Impedance:- 4.5% ((Allowable tolerance as per IS) Maximum altitude 1000 m HV winding temperature class F LV winding temperature class F Climatic classification C1 Environmental classification E2 Fire behaviour classification F1 Enclosure:- Yes, Neutral Terminal:- 2 nos. Index of protection : IP23(Indoor ) Fitings Winding temperature Scanner, Temperature indecator Thermal protection relay, electronic converter type, R & D Plate , Liftings Lugs , Bi- direction rollars , Marshalling Box, Inspection cover & accessories as per IS Primay Side Termination : Cable Termination Secondary Side Termination : Upward rising Terminals for Cable Termination
Erection / Installation of 11/0.415 KV 315 KVA Power Transformer including carriage within a lead of 30 Mtr. by placing in position & fixing after levelling, fitting & checking up instruments & relay set. & instrument test of all instruments and obtain final approval from the Inspector of Directorate of Authority required for making Electrical Structure & commissioning complete .
Erection/Installation of 3 panel, cubical type H.T. switch gear with -PT incl. carriage within a lead of 30 mtr. by placing in position, assembling, lining up, levelling and fixing on floor, fitting & checking all instruments, relays correctly set according to requirement.
Making testing arrangement & submitting the test report for high voltage testing of specified voltage incl.checking & testing of all HT / LT equipmens (relay setting, vector group, magnetizing balance, magnetizing current, Routine tests etc) as per requirement of Directorate of Electricity and commissioning the installation after obtaining the approval of Directorate of Electricity.
Supply & laying of 11 KV(UE) grade 3 core 240 sq.mm. XLPE HT cable with Al. conductor from consumer's gear to transformer to be laid through masonery trench as per G.S. as per direction of EIC. (Make - NICCO / Gloster/ Havels or equivalent make as approved by E.I.C)
S & Laying of 1.1KV grade 3-RUN 3.5 core 300 sq.mm. XLPE/A AL. cable to be laid through masonary / U.G trench as per G.S. (from Transformer to ACB of sub-station L.T. main pannel board) -(Make - NICCO / Gloster/ Havels or equivalent make as approved by E.I.C)
S& laying 240 sq. mm. single core multistrand PVC insulated flexible Cu cable in following manners from earth electrode to neutral earth busbar and from earth busbar to transformer neutral point as required (for transformer neutral earthing)
a) Through prelaid GI pipe protection pipe from earth electrode to earth busbar
b) through PVC flexible pipe(reinforced) of suitable size from earth busbar to transformer neutral partly concealed in floor & partly on wall/surface with saddles etc. incl. S&F PVC felixble pipe as required
Finishing the cable ends by crimping method incl. S&F copper socket, insulating tape and jointing materials etc. as required suitable for single core 240 sq. mm. copper wire.
Jointing of H.T. cable of 11 KV grade 3 core 240 sq.mm. XLPE cable incl.supply of necy. jointing materials & compound (Heat shrink cable jointing kit of approved make) for switch gear & transformer terminations on H.T. sides incl. testing as per G.S.
S & F compression type gland complete with brass gland, rubber ring for dust & moisture proof entry of 3.5 core 300 sq.mm. PVC/A Al. cable incl. finishing the ends by crimping method as per G.S.
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. as per GS. [2(c)/G-1]
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. [For 2 nos. Transformer neutral − 4 nos, 2 nos. transformer body − 4 nos., consumer gear − 2 nos., L.T. Panel board- 2 nos.]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Extra treatment of soil by using salt & charcoal for pipe electrode as to G.S. [3(b)/G-2]
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [4(d)/G-2]
Supply & fixing of earth busbar of Galv. (Hot dip) M.S. flat of 50 mm x 6 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [4(c)/G-2]
Insulating the 65x8 mm MS flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar)
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. [5(e)/G-3]
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
Supplying & Fixing 40 x 6 mm MS flat having length 1 ft. (approx.) for supporting of 3.5 core 300 sq.mm XLPE/PVC/A Al. cable complete with back clamp, nut & bolt with double washer etc.
S & F special type earth electrode clamp made of GI flat with nuts, bolts, washer etc. suitable for 80 mm dia GI pipe earth.
S & F CO2 fire extinguiser (4.5 kg. capcity) (Surex / Fireshield / Max Well) on wall with necessary MS bracket as per G.S. incl. mending good the damages to original finish.
S & F 9 litre capacity fire bucket on wall with necy. M.S. bracket incl. mending good the damages.
S & F best quality FIRST AID BOX (Al. body) as per PWD specification, complete with all the items as required by rule of sub-station on MS bracket incl. damages to original finish.
S & F 'shock treatment chart' on wall with necessary screws.
S & F 11 / 6 KV grade rubber hand gloves.
S & fixing 6' x 3' x 1/2" rubber mat suitable for 11KV sub-station (Best quality & ISI approved).
S & drawing 1.1KV grade 4 core 2.5 sqmm. PVC/Ar. copper cable from transformer's WTI relay to VCB WT relay Relay for power & control supply.
S & drawing 1.1KV grade 2 core 2.5 sq.mm. PVC insulated F.R copper conductor from Power DB to VCB.
Finishing the end of 2.5sqmm. PVC insulated copper conductor by crimping arrangement as to G.S.
Making necessary internal connection from Transformer winding temperature relay to VCB WT Relay and Power DB to VCB including making connection etc. complete by expert HT Personal including testing, commissioning etc.
Main LT Panel Board Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. (Main LT Panel Board) [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel.
Construction Details :
All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.
Incoming Arrangement :
i) 415 V, 630A, 50 kA 4(four) pole electrically draw- out type A.C.B. with Microprocessor-based protection release. (Make – L & T, Cat no. SL96071 or equivalent model of SIEMENS) -----3 nos.
Bus bar section :
500V, 800 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x50 mm x 10 mm + 1x50 mm x 10 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
Outgoing Arrangement :
a) 415V 400 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95591 or equivalent cat of SIEMENS/ABB) in open exexution.---- 3 Nos.
b) 415V 250 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95682 or equivalent cat of SIEMENS/ABB) in open exexution.---- 2 Nos.
(c) 415V 200 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95588 or equivalent cat of SIEMENS/ABB) in open exexution.---- 1 No.
(d) 415V 125 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95009 or equivalent cat of SIEMENS/ABB) in open exexution.---- 4 Nos.
e) 415V 63 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95651 or equivalent cat of SIEMENS/ABB) in open exexution ----- 2 Nos.
f) E.I. Danger Board of suitable size ------- 1 no.
Metering Panel
a) Multipurpose Meter Digital Type Load Monitor ( Make L&T, Cat No. - WL442011OOOO) - 1 No.,
b) LCD single function Meter ( Make L& T, Model- CAT NO.WL111020OOOO or equivalent)- for ammeter --- 3 nos.
c) LCD single function Meter ( Make L& T, Model no..WL112020OOOO or equivalent) for voltmeter-- 3 nos..
c) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent) - 2 Set.
d)500/5 Amp ratio C.T (Kappa or equivalent) --- 9 nos.
e) Supplying & Fixing 6 Amp SP MCB---- 9 nos.
f) Slide lock fuse---- 9 nos.
Interconnection :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pve insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
Earthing :-
A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. wire.
The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.
Emergency LT Panel Board Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel.
Construction Details :
All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.
Incomming Switch :
(a) 415V 400A FP MCCB with Microprocessor release ( L&T Cat No.-CM93004OOOOX1 or equivalent model of SIEMENS/Legrand) with extended spreaded terminals (LT-Kit ST98066OOOO- 8Pcs) Rotary Handle(L&T cat no.--CM99860OOOO or equivalent model of SIEMENS/Legrand)-- 1 No.
Bus Bar :
500V, 500 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x60 mm x 5 mm + 1x60 mm x 5 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
Outgoing Switches :
a) 415V 250 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95682 or equivalent cat of SIEMENS/ABB) in open exexution.---- 2 Nos.
b)415V 200 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95588 or equivalent cat of SIEMENS/ABB) in open exexution.---- 1 No.
(c) 415V 125 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95009 or equivalent cat of SIEMENS/ABB) in open exexution.----1 No.
d)(c) 415V 100 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95570 or equivalent cat of SIEMENS/ABB) in open exexution.----1 No.
(e) 415V 63 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95651 or equivalent cat of SIEMENS/ABB) in open exexution.----7 Nos.
(f) 415V 32 Amps TPN SFU units with HRC fuses (Make:- L&T : Cat No.- SK95653 or equivalent cat of SIEMENS/ABB)) in open exexution.- - 1 No.
(g) 415V 315 A four pole on-load change-over Switch Disconnector unit(Make – L & T Cat no. CO33150OOOO or equivalent model of SIEMENS/Havells/ABB) ----- 1 No.
Metering Panel
a) Multipurpose Meter Digital Type Load Monitor ( Make L&T, Model -QUASAR) - 1 No.,
b) LCD single function Meter ( Make L& T, Model- CAT NO.WL111020OOOO or equivalent)- for ammeter --- 3 nos.
c) LCD single function Meter ( Make L& T, Model no..WL112020OOOO or equivalent) for voltmeter-- 3 nos..
c) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent) - 2 Set.
d) 300/5 Amp ratio C.T (Kappa or equivalent) --- 9 nos.
e) Supplying & Fixing 6 Amp SP MCB---- 9 nos.
f) Slide lock fuse---- 9 nos.
Interconnection :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pve insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
Earthing :-
A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board and brought outside the panel. All electrical equipment are to be properly earthed with suitable size G.I. wire.
The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.
All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.
Preparation & submission of a substation drawing (by AUTO-CAD) showing HT & LT cable ducts, Single line power diagram, EI layout, Earthing system (i.e. equipment and neutral earthing) etc. with elevation & plan as per requirements of DOE.
Internal E.I. of Sub-Station Building Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(Avg. run-9 mtr.) [2a(iv) / E-9 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish
On Board [ 4(a-i) / E- 10 ]
Avg. Run-4.5mtr. [ 4(a-iv) / E- 10 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
13 mm dia 3 mm thick [ 5 (a)/ E- 3 ]
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
25mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(6 sqmm)+1 x (4 sqmm) [ 1(v) / E- 9 ]
4x(10 sqmm)+2x (6 sqmm) [ 1(d1) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
e) 10 sq mm [9(iii) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5]
200 x 150 x 65 [11(d)/E-4 ,13(d)/E-5)]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC.
4 Way ( Up to 160 A ) Make - Legrand, Enclosure 607913/Siemens-Enclosure-8GB31571RC)/ Schneider-Enclosure-A9HVD04M/ L&T Enclosure- (LTVD04MGN) or equivalent make as approved by E.I.C][15 / D-11 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider/ Crabtree) as per direction of EIC. )
6 Way [Make - Legrand, Enclosure-607716/ Schneider, Enclosure-A9HTND06 /Crabtree, Enclosure- (DCDKTHODCW06 or equivalent cat of LT/Siemens as approved E.I.C] [ 14 / D- 10 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens Enclosure(8GB32102RC14) /Schneider Enclosure-(A9HSND12) or equivalent model of Legrand/L&T as approved by EIC]. [ 13 / D- 9 & D-10 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand / Schneider/L&T/Siemens) as per direction of EIC]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical / SPNDB enclosure with IP-42/43 as per GS
6 Way (Horizontal) [16/D-12]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes[ Make NICCO/ Gloster/KEI/Havells as approved by E.I.C]
4 Core 50 Sqmm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
Above 35 sq. mm and upto 95 Sq. mm [ 5(ii)/ F- 3 ]
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. [ 4(a)/ F- 3 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
4 Core 50 Sq. mm [7(c)/F4 & 8(b) /F5]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necy. connections as required [25/E-7]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS. [22 / E-6 ]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Twin fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent model of CG / Bajaj / Wipro/Havells as approved by E.I.C] incl. 2 no. 18W Master LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent make CG / Bajaj / Wipro/Havells as approved by E.I.C] incl. 1 no. 18W Master LED Tube
Fixing only single/twin LED batten light fitting suspended from the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ]
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Usha-Striker or equivalent model of Havells/CG/Orient as approved by E.I.C)
a. 1200 mm Sweep
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from[ 31/D-14 ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Engraving the deptt. number with 10 mm lettering on the body as per GS. [ 24 (a) / C-3 ]
Extra for additional one letter incl. hifen, stroke and stop [24(b)/C-3]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS [ 26 (a) / C-3 ]
S & F of 250V 15" sweep 1420 RPM A.C. exhaust fan complete with frame, legs & louver shutter etc. after cutting wall & making hole incl. S & F nut, bolt, washer & fixing the louver shutter and providing necy. length of PVC insulated copper wire for making connection and mending good the damages to original finish incl. s&f louver shutter as per G.S. ) . [Make - EPC]
S&F of 250V timer DB (equivalent to 4 way SPNDB in size) with sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 1 no 24 hr analog time switch complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC.(Exhaust fan control)
Cabling work from Sub-station to different buildings/Load points Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make NICCO/ Gloster/KEI/Havells as approved by E.I.C]
3.5Core 70 Sq. mm
3.5Core 95 Sq. mm
3.5Core 120 Sq. mm
3.5Core 150 Sq. mm
3.5Core 185 Sq. mm
Laying of cable in underground trench as per GS for the following numbers of Cables.
one no. Cable above 35 and upto 185 Sq. mm [ 1(b)/ F- 2 ]
Laying of cable above 50 sq mm through exsisting GI pipe. [3(b)/F-1]
Laying of cable upto 150sq mm in exsisting masonry trench as per GS [4(a)/F-3]
Laying of cable above 150 sq. mm and upto 300sq mm in exsisting masonry trench as per GS [4(b)/F-3]
Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed. [ 2(b)/ F- 2 ]
Laying of cable on exsisting cable tray & binding with GI wire.
From 70sq mm to 150sq mm [6(ii)/F-3]
Above 150sq mm [6(iii)/F-3]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
3.5 Core 70 Sq. mm [7(d)/F4 & 8(b) /F5]
3.5 Core 95 Sq. mm [7(d)/F4 & 8(b) /F5]
3.5Core 120 Sq. mm [ 7(d)/F4 & 8(b- xix) /F5]
3.5Core 150 Sq. mm [ 7(d)/F4 & 8(b- xx) /F5]
3.5 Core 185 Sq. mm [7(d)/F4 & 8(b) /F5]
Supply & Laying of 80 mm dia GI pipe (ISI M) as per GS. [11(f)/F-6]
Supply & Laying of 100 mm dia GI pipe (ISI M) as per GS. [11(g)/F-6]
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support --With /without 25x25x3mm angle iron support [34(a)/D-14]
Supply & Fixing of perforated GI cable tray bend as per GS. [34(b)/D-15]
Supply & Fixing of perforated GI cable tray Reducer as per GS. [34(d)/e-15]
Supply and installation of Sub-Main Distribution Board (SMDB) for power distribution consisting of following components : (a) SMDB Type - 4 ways (Make : L&T, Type TN250D O/G 100A 4Ways, cat no- DA20D1044CZZ0 or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (b) Incoming Device - 200A MCCB (Make : L&T, Type DN1-250C 3 Pole MCCB - 200A- cat no - CM90638OONO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (c) Outgoing Device - 100 A (Make : L&T, Type DN0-100C 3 Pole MCCB - 100A , cat no -CM91612OOKOOG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 3 nos. d) Outgoing Device - 3-pole 63 A MCCB (Make : L&T, Type DN0-100C 3 Pole MCCB - 63A , cat no -CM91612OOHOOG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 nos.
(e) Bottom Cabling box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (f) Meter Extension box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (g) Side Cabling box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 2 nos. (h) Corner box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 4 nos. (i) 200/5 Amp ratio C.T (Kappa) -- 3 nos. (j) LCD Multifunction Digital Panel Meter [L&T cat no.-WL440511OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -- 1 set (j) 1 phase LED Ammeter [L&T cat no.-WL111010OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -3 set (k) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. (l) Fixing the Sub-Main Distribution Board .
Supply and installation of Sub-Main Distribution Board (SMDB) for power distribution consisting of following components : (a) SMDB Type - 8 ways (Make : L&T, Type TN250D O/G 100A 4Ways, cat no- DA20D1084CZZ0 or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (b) Incoming Device - 200A MCCB (Make : L&T, Type DN1-250C 3 Pole MCCB - 200A- cat no - CM90638OONO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (c) Outgoing Device - 3-pole 63 A MCCB (Make : L&T, Type DN0-100C 3 Pole MCCB - 63A , cat no -CM91612OOHOOG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 4 nos.
d) Outgoing Device - 3-pole 32 A MCCB (Make : L&T, Type DN0-100C 3 Pole MCCB - 32A , cat no -CM91612OOEOOG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 4 nos. (d) Bottom Cabling box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (e) Meter Extension box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (f) Side Cabling box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 2 nos.
(g) Corner box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 4 nos. (h) 200/5 Amp ratio C.T (Kappa) -- 3 nos. (i) LCD Multifunction Digital Panel Meter [L&T cat no.-WL440511OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -- 1 set (j) 1 phase LED Ammeter [L&T cat no.-WL111010OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -3 set (k) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. (k) Fixing the Sub-Main Distribution Board . (j) 1 phase LED Ammeter [L&T cat no.-WL111010OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -3 set (k) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. (k) Fixing the Panel board
Supply and installation of Sub-Main Distribution Board (SMDB) for power distribution consisting of following components : (a) SMDB Type - 12 ways (Make : L&T, Type TN630D, O/G COMBI 12 ways, cat no- DA6AD1124CZZ0 or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (b) Incoming Device - 400A MCCB (Make : L&T, Type DN3-400D 3 Pole MCCB - 400A- cat no - CM94005OOR1OG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (c) Outgoing Device - 3-pole 160A MCCB (Make : L&T, Type DN1-250C 3 Pole MCCB - 160A , cat no -CM90638OOMO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 2 nos. d) Outgoing Device - 3-Pole 80A/100 A MCCB (Make : L&T, Type DN0-100C 3 Pole MCCB - 80A/100A , cat no -CM91612OOJOOG /CM91612OOKOOG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 10 nos.. (d) Bottom Cabling box for SMDB ( Make -: L&T Cat no.-CM91062OOOO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no.
(e) Meter Extension box for SMDB ( Make -: L&T Cat no.-CM91064OOTO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (f) Side Cabling box for SMDB ( Make -: L&T Cat No.-CM91120OOHO & CM91121OOHO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 2 nos. (g) Corner box for SMDB ( Make -: L&T cat no.-CM91089OOOO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 4 nos. (h) 400/5 Amp ratio C.T (Kappa) -- 3 nos. (i) LCD Multifunction Digital Panel Meter [L&T cat no.-WL440511OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -- 1 set (j) 1 phase LED Ammeter [L&T cat no.-WL111010OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -3 set (k) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. (k) Fixing the Sub-Main Distribution Board .
Supply and installation of Sub-Main Distribution Board (SMDB) for power distribution consisting of following components : (a)SMDB Type - 12 ways (Make : L&T, Type TN250D O/G 100A 12Ways, cat no- DA20D1124CZZ0 or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (b) Incoming Device - 250A MCCB (Make : L&T, Type DN1-250C 3 Pole MCCB - 250A- cat no - CM90638OOPO or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (c) Outgoing Device - 80A/100 A 3 Pole MCCB(Make : L&T, Type DN0-100C 3 Pole MCCB - 80A/100A , cat no -CM91612OOJOOG /CM91612OOKOOG or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 12 nos.. (d) Bottom Cabling box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no. (e) Meter Extension box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 1 no.
(f) Side Cabling box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 2 nos. (g) Corner box for SMDB ( Make -: L&T type TN250D or equivalent model/cat of Havells/Siemens/ABB as approved by E.I.C) -- 4 nos. (h) 200/5 Amp ratio C.T (Kappa) -- 3 nos. (i) LCD Multifunction Digital Panel Meter [L&T cat no.-WL440511OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -- 1 set (j) 1 phase LED Ammeter [L&T cat no.-WL111010OOOO or equivalent cat of SIEMENS or other make as approved by E.I.C] -3 set (k) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. (k) Fixing the Sub-Main Distribution Board .
External E.l Work/Compound Illumination Supply & Delivery of 9 Mtr Steel Tubular Pole (Calcutta poles/Subham/Transrail or other make as approved by E.I.C) as per specification Type 410 SP -28 as overall length 9 mtr weight 113kg. & having diamention are : Out side dia & thickness of the Bottom section ( 139.7 x 4.50) mm; Middle;(11 4.3 x 3.65) mm ,Top Section (88.9 x 3.25 ) mm with fixing the base plate and GI earth bolt after making drilled holes etc. on pole as per direction of EIC
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly
Upto 9.0 mtr. Size 0.6x0.6x1.70 mts [1 (a)/ H- 1 ]
Extra on items above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, as per GS [3 (a)(i)/ H- 1 ]
Supply & Fixing of 240V, 90 W LED, Street light luminarie with IP66 Protection (Make- Crompton Cat no. LSTP-90-CDL-M with CKT-5700K or equivalent make/model of Philips/Bajaj/Wipro/Havells or equivalent make/model as approved by E.I.C) on ST Pole as per direction of E.I.C.
S & F of post top lantern incl neccy GI pipe for fixing on post at entry gate (Crompton Geaves-Cat no. LPTO-60-CDL or equivalent make of Philips/Bajaj/wipro or equivalent make/model as approved by E.I.C) with IP-66 protection as per direction of E.I.C
S/L of 3 x 1.5 Sqmm Cu wire [ Make- Finolex / Gloster/KEI/Havells] from loop box to fittings as per GS through 19 mm polytheane. [ 1(b)/ E-9 & 1(b)/ E-2 ]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Havells as approved by E.I.C]
4 Core 10 Sq. mm
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
2.5 to 35 Sq. mm [ 2(b)/ F- 1 ]
Laying of cable in underground trench as per GS for the following numbers of Cables.
Upto 35 Sq. mm [ 1(a)/ F- 2 ]
Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr as per GS [ 2(a)/ F- 2 ]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Upto 35 Sq. mm [ 1(a)/ F- 2 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4Core 10 Sq. mm [7(c)/F4 & 8(b- xiii) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
50mm dia [11(d)/F-6]
S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC.
S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Twin arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. [NS]
S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Triple arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. [NS]
Painting of Steel Tubular Pole of following lengths and 2 nos. of aluminium coats of paint over 1 coat of RO priming with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
Upto 9 mtr. long pole [4 (a)(i+ii)/ H- 2]
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Havells as approved by E.I.C]
2 Core 10 Sqmm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of cable upto 2 core 25 sqmm on wall/surface including S & F MS clams with earthing attachment in 1 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [2(d)/F-1]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
2 Core 10 Sq. mm [7(a)/F4 & 8(b- iii) /F5 ]
Supply & Fixing of 240V, 72 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Crompton-Cat no.-LSTP-72-CDL-M or equivalent model of Philips/Bajaj//wipro/Magik) on existing MS Pipe/Mini Pole as per direction of E.I.C
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI(M) pipe medium quality (Bansal/Jindal make) incl. making cc (6:2:1) muffing 600x600x750 mm in size with 3 mm thick neatly finished cement plaster incl. S & F 8”x6”x4” C.I. looping cable box incl. S & F 40 mm. dia. G.I.(M) 1.5 Mtr. Long arm bracket for fixing flood light & neccy connection by 2x 1.5 sq mm Cu wire. This is incl. painting as per GS.
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 20/25A TPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 18/25A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC
S&F of 415V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 20/25A TPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 18/25A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC
S/F of stainless steel loop box with hinged door arrangement having locking with allenkey and SS cover of 200 x 250 x 100 dimension, and with one no (6-32A) SPMCB, one 63A 4 terminal STUD with stainless steel bolts, nuts, washers complete within foundation as per direction of EIC.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1].
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-10 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
RASH ELECTRICAL WORKS
JAYBEECO
PARTHA SARKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .