Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.7 Cr+₹17.1 L (11.4%)Rejected-Finance NEAR GOVT MIDDLE SCHOOL VILLAGE KHERI SANWAL TEHSIL AND DISTRICT CHARKHI DADRI | CHARKHI DADRI | CHARKHI DADRI | HARYANA | ₹1.7 Cr+₹17.1 L (11.4%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.7 Cr+₹24.4 L (16.3%)Rejected-Finance | ₹1.7 Cr+₹24.4 L (16.3%) | L3 | Rejected-Finance Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
23 Mar 2020, 2:00 pmClosed
Director
Maharaja Agrasen Medical College Agroha (Hisar)
Repair and Improvement work in Hospital Block a at MAMC Agroha
2020_HRY_123922_1
Tender/2020/Repair BlockA/03
Open Tender
Civil Works - Buildings
Works
180 days
Maharaja Agrasen Medical College Agroha (Hisar)
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
Director
₹2.8 L
Yes
2 Jul 2020
17 Mar 2020
24 Mar 2020
17 Mar 2020
23 Mar 2020
17 Mar 2020
Amount
Civil Work items 1 to 78 Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing HSR 8.5 (b) In cement
- do - First Floor
- do - Second Floor
Dismantling reinforced cement concrete with cleaning and straghtening and cutting of bars if required. Terrace leval 4th storey HSR 8.6 (e)
Dismantling white or coloured glazed tiles (to be carefylly removed) HSR 8.38)
Dismantling cement conglemerate/terrazzo floors 25 mm to 50 mm Thick including concrete base (HSR 8.25)
- do - 2nd Story HSR 5.25+note (i) (d)
- do -3rd Storey HSR 8.25+note(ii) (d)
Removing doors and windows (wooden and steel) together with the Dismantling of walls:- HSR 8.17 (a) door
(b) windows
Scraping Cement plaster. HSR 8.32 (c)
- do - 2nd Story HSR 8.32 (c) +note (ii) (d)
- do -3rd Storey HSR 8.32 (c) +note(ii) (d)
Scraping white wash and colour wash (HSR 8.32 (a)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinthlevel. (HSR 11.7)
- do - 2nd Story HSR 11.7+11.41+note (i)
- do - 3rd Story HSR 11.7+11.41+note (i)
11.43 cm thick brick wall laid in cement sand mortar 1: 4 in superstructure. (HSR 11.48 (a)
- do - 2nd Story HSR 11.48 (a) +note (iv) (a)
- do - 3rd Story HSR 11.48 (a) +note (iv) (a)
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded:- HSR 15.77 (a) vertical 2nd Storey
- do - 3rd Story HSR 15.77 (a) +note (i)
(b) horizontal 2nd Storey
- do - 3rd Story HSR 15.77 (a) +note (i)
Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in first storey upto 4 metres above plinth level HSR 10.57
- do - 2nd Story HSR 10.57+note (v)(b)
- do - 3rd Story HSR 10.57+note (v)(b)
Conglomerate floor 40 mm thick cement concrete topping 1:2:4 HSR 14.9
- do - 2nd Story HSR 14.9+note (i)
- do - 3rd Story HSR 14.9+note (i)
Supplying and filling cinder on roof (1st storey) including light ramming. HSR 13.65
Providing & fixing ceramic tiles/ anty skid tile of size 400mm x 400mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (HSR 14.91) Note: Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO (Sample of Tiles to be got approved from Engineer-in-charge).
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -In Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1: 3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete. HSR 14.92 (b) Size of ceramic Glazed tiles 300mm x 450mm
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt – 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge. With or without groves (HSR 13.92)
Kotah stone flooring minimum 25mm thick, in any pattern as specified over 20mm thick base of cement coarse sand mortar 1: 3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62)
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. HSR 14.66
12 mm thick cement plaster 1:5 (HSR 15.6)
- do - 2nd Story HSR 15.6+note (i)
- do - 3rd Story HSR 15.6+note (i)
Top khurra 0.6 m X 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50)
Cement concrete 1:2:4 gola 10 cm X 10 cm quardrant along junction of roof with parapet wall finished smooth, where specially specified. (HSR 13.64)
Providing & fixing PVC Rain water pipe 6 kg. Pressure of ISI mark in cement mortar during masonry work. HSR 13.89 (a) 100 MM dia PVC pipe 6 Kg. Pressure.
(b) 150 MM dia PVC pipe 6 Kg. Pressure.
Providing & fixing PVC Bend ISI Mark HSR 13.90 (a) 100 mm dia PVC Bend
(b) 150 mm dia PVC Bend
Factory manufactured solid flush door shutters with block board, core as per I.S. No. 1659-1969 bonded with water proof type phenolformaldehyde synthetic resin, hot pressed, conforming to I.S. 2202 part I and II , fixed in position i/c iron hinges , screws , chocks / cleats and stops , etc. (excluding the cost of any fittings other than specified above , but i/c labour for fixing the same in position). Duro or Century 17.93 - note below item no. 17.18 (a) Commercial veenering with vertical grains or cross bands and face vener on both sides commercial facing the laminated core and lipped edges. (as approved by Engineer-in-charge.) (ii) 30mm thick Double leaf (423.00 - 11.85 = 411.15)
(iii) 35mm thick (448.00 - 11.85 = 436.15)
Wooden glazed shutter of commercial hard wood such hollock, champ, wood (non-confireous timber other than teak conforming to I.S specification No. 1003 kiln seasoned) door and window shutters without spring housed in chawkhats including chocks, iron hinges and screws etc. complete fixed in position excluding the cost of tower bolts & handles but including the labour for fixing the same) (including 4mm thick glass panes with beading complete in all respects) 17.31 (i) 35mm thick (Openable) - derived note (i) below item no. 17.18 are applicable
Wire guage commercial hard wood such hollock, champ, chickrssy etc. (non-confireous timber other than teak conforming to I.S specification No. 1003 kiln seasoned) door and window shutters without spring housed in chawkhats including chocks, iron hinges and screws etc. complete fixed in position excluding the cost of tower bolts & handles but including the labour for fixing the same) HSR 17.31 (i) 30 mm thick - note (i) below item no. 17.18
Cost of aluminium fitting complete for doors and windows, such as tower bolts, handles, etc., and screws for these fittings (excluding sliding bolt)- HSR 17.72 (a) for single lead shutter
(b) for double lead shutter
Providing and fixing 150 mm hasps and Staples with necessary screws, etc., complete- HSR 17.78 (b) aluminium
Providing and fixing sliding bolt with nuts and screws etc. complete- HSR 17.83 (b) aluminium- (i) size 300 mm x 16 mm
(ii) size 250 mm x 16 mm
Providing and fixing 0.50 mm thick aluminium sheet, including cost of necessary screws, etc., complete.HSR 17.87
Supplying and fixing glass panes including special metal sash putty of approved make HSR 18.30 (b) glass panes 4 mm thick, exceeding 40 sq dm areas.
S/F glass panes including special metal sash putty of approved make HSR 18.30 (b) Glass panes 4 mm thick, exceeding 40 sq. dm. area (Modi / Trivani MAKE) + Top note (v) of chapter 17 Extra for providing and fixing frosted glass insted of ordinary glass
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (HSR 16.58)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3)
Providing two coats of exterior acrylic emulsion paint. HSR 16.79 (b) 1st. quality
Factory manufactured solid flush door Shutters (Century /Duro), with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- The shutters is to be warranted for a period of 5 year for any type of manufacturing defects / failure. HSR 17.93 (a) commercial veneering with vertical grains or corss bands and face veneer on both sides commercial facing with laminated core and lipped edges:- (i) 25 mm thick
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering , laid in position, complete in all respects. HSR 10.82 + 10.95 (a) + note (v) (b)
Cold twisted deformed (ribbed / TOR steel) bars for RCC works where not included in the complete rate of RCC including bending binding and placing in position complete. (HSR 18.22)
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12)
Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect (HSR 18.33)
Applying priming coat with metal primer on New steel or iron work including preparation of surface. (HSR 16.9)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (HSR 16.2)
Supplying and fixing hydraulic door Closer, I.S.I mark, with necessary Screws, etc., complete- HSR 17.82 (c) I.S.I designation no. III (size of door 851 mm to 1000 mm)
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified sections, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, or approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lugs complete:- HSR 18.34 (a) door and window frame of size 89 mm X 50 mm with 40 mm wide single rebate
Providing & Fixing Vitrified Tiles 800 x 800 mm of approved make in flooring laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1.3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (N.S.) Note: Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO (Sample of Tiles to be got approved from Engineer-in-charge).
Providing and fixing wall tiles Double Charged vitrified tiles of size 600 x 600mm of approved make in skirting/dados laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with White cement slurry mixed with pigment to match the shade to tiles. Note:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO. (Note: Double Charged Vitrified tiles shall be used.). (N.S.)
Grinding of terrazzo flooring, kotah flooring, marble flooring, and dado on all item with mirror polishing complete in all respects including all required material used in grinding in all story i/c ground floor+1st floor + 2nd floor & third floor etc.(N.S.)
Setting right depression on tile terracing at all heights by removing the existing tiles in good condition and to relay the tiles including setting the tiles in mud mortar and grouting in cement mortar 1:3 cement course sand mortar so that no water is stag nated in the terrace. L.S. (N.S.)
Re-pointing on the terrace with 1:2 CM (N.S.)
Providing & fixing at all height and level, 20mm thick granite stone flooring (as per approved sample) with 20mm thick base in 1:3 (N.S.)
Supply and fixing of powder coated (70 microns thick) Aluminium doors as per drawings at all heights and levels. The outer frame shall be 2 mm thick Jindal section No. 4617. Frame style shall be 2 mm thick Jindal section No. 4526, bottom rail 2 mm thick Jindal section no. 4529, top & middle rails 2 mm thick Jindal section no. – 4524 and clip section no. – 4407 of weight 0.097 kg/m including nut bolts, hinges, screws, angular cleats, locks, handle and tower bolts with complete fittings complete in all respects up to the entire satisfaction of the Engineer-in-charge. (N.S.)
Public Health Work items 79 to 133 PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (as approved by the Engineer-in-charge) EUROPEAN TYPE WATER CLOSET SUITE, SYPHONIC TYPE, Consisting of- HSR 30.5 (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge) (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (a) Single trap symphonic W.C. Suite (i) White
EXTRA OVER item nos. 30.3 to 30.6 FOR PROVIDING AND FIXING BEST INDIAN MAKE PLASTIC HYGENIC SEAT with lid complete instead of hollow Black or white plaster seat and lid. HSR 30.13 (i) White plastic seat (Solid)
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (to the approval of the Engineer-in-charge) INDIAN TYPE WATER CLOSET SUITE CONSISTING OF:- HSR 30.1 (i) Closet set VITREOUSCHINAWARA W.C. PAN WITH FOOTRESTS, 100 MMH.C.I. ‘P’ TRAP WITH or without vent as required and suitable joint for closet inlet; (ii) 12 ½ LITRES CAPACITY mosquito proof CAST IRON FLUSHING CISTERN BEST INDIAN MAKE I.S.I. MARKED NOMOS OR OTHER (as approved by the Engineer-in-charge) painted with non-yellowing white or other approved shade ENAMEL PAINT ON OUT SIDE AND BLACK BITUMASTIC SUPERIOR PAINT OR APPROVED manufacture ON INSIDE complete with all accessories such as 20 mm G.I over flow pipe with specials & clamps upto 15 cm above floor level of W.C. room, and brass perforated mosquito proof cap, 32 mm outlet, 15 mm I.S.I marked ballcock, G.I pull and chain, R.S. or C.I painted brackets and mosquito proof couplings for outlet and overflow pipes, etc. (iii) Galvanized inside and outside STEEL FLUSH PIPE With clips;Complete in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS AND PAINTING OF FITTINGS,ETC. (a) Size 580 mm (i) White
EXTRA OVER item nos. 30.1 to 30.4 and 30.6 FOR PROVIDING AND FIXING 15 LITRES CAPACITY C.I. LOW LEVEL VITREOUS CHINAWARE CISTERN complete with flush bend all other necessary Fittings instead of C.I high level cistern complete with fittings. HSR 30.12 (i) White
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE A RANGE OF TWO URINALS FLAT BACK OR ANGULAR LIPPED FRONT 610 HIGH IN VITREOUS CHINA-WARE WITH 5 LITRES CAPACITY BEST INDIAN MAKE C.I. AUTOMATIC FLUSHING CISTERN WITH FITTINGS AND FLUSH PIPE ETC., COMPLETE AS FULLY DESCRIBED IN ITEM NO. 30.25 ABOVE. HSR 30.26 Range of two urinals (i) White
EXTRA FOR PROVIDING AND FIXING VITREOUS automatic flushing CISTERN INCLUDING FITTINGS and brackets instead of C.I flushing cistern COMPLETE. HSR 30.37 (a) 5 Litres capacity cistern (i) White
Providing and fixing 25 mm thick marble backs for the different type of urinals. HSR 30.40 (II) LARGE SIZE 835mm x 355 mm (i) White
PROVIDING AND FIXING IN POSITION INDIAN MAKE (ORDINARY) LAVATORY SUITES Consisting of Lavatory in VITREOUS CHINAWARE size as given Below (to the approval of the Engineer-in-charge) including china plug for tap hole where necessary; R.S or C.I BRACKETS for building into wall including Painting; 32 mm C.P BRASS WASTER WITH C.P brass chain and rubber plug; 15 mm C.P BRASS SCREW DOWN PILLAR TAP WITH Jamnuts or couplings best design ( as approved by the Engineer- In-charge) ALL FITTINGS BEST INDIAN MAKE and; to the approval of the Engineer-in-charge. ALL brass work chromium plated and COMPLETE in all respects INCLUDING cutting and MAKING GOOD THE WALLS FLOORS AND PAINTING OF FITTINGS ETC. WHITE HSR 30.41 (iv) Size 550 mm x 400 mm with one no. tap
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE TOWEL RAILS FIXED in with rawlslugs embedded in walls with C.P brass screws. Complete in all respect INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (HSR 30.68) (e) C.P brass towel ring.
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P brass screws and complete in all respects including cutting and making good the wells etcs. HSR 30.70 (a) C.P BRASS (i) Soap dish large
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE BEVELLED EDGE 5.5 MM THICK MIRRON Mounted on ASBESTOS sheet GROUND FIXED IN POSITION BY MEANS OF 4 NOS. CHORMIUM PLATED BRASS SCREWS AND WASHERS over rubber washers and rawl plug embedded in the wall or chromium plated brass clamps with C.P brass screws (as required by the Engineer-in-charge) COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. HSR 30.71 (a) INDIAN MAKE (i) 600 mm x 450 mm
Providing and fixing in position C.P brass stop cocks (as Approved by the Engineer-in-charge) HSR 30.76 (a) 15 MM STOP COCK (ii) Concealed stop cock with flange.
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE C.P BRASS INLET CONNECTION 15 MM WITH 375 MM PIPE AND C.P BRASS NUTS. (HSR 30.83)
PROVIDING AND FIXING IN POSITON BEST INDIAN MAKE (TO THE APPROVAL OF THE ENGINEER-IN- CHARGE) STORAGE TYPE AUTOMATIC ELECTRIC WATER HEATER, PRESSURE/NON PRESSURE TYPE. THERMOSTAT CALLY CONTROLLED, SUITABLE FOR OPERATION ON 230 VOLTS, 50 CYCLES SINGLE PHASE VERTICAL WALLMOUNTING FITTED WITH WITH- DRAWABLE AND ADJUSTABLE TYPE A.C. THERMOSTAT. THERMOSTAT KNOB TO BE READILY. ACCESSABLE THROUGH THE OPENING OF SUITABLE COVER FOR ADJUSTEMENT OF TEMPERATURE IN THE INSALLED POSITION OF HEATER AND THE THERMOSTAT SHOULD BE WITHDRAWN WITHOUT HAVING TO DRAIN THE WATER, ELECTRIC HEATING ELEMENT SHOULD MADE OUT OF COPPER TUBE (HEATING ELEMENT SHOULD BE EASILY REMOVED AND REPLACED IN THE INSTALLED POSITION OF HEATER) A NEON INDICATOR 1AMP. INNER CONTAINED MADE OUT OF COPPERTINNED BOTH FROM INSIDE AND OUTSIDE OUTER CONTAINER MADE OUT OF MILD STEEL SHEET FINISHED IN GLEAMING WHITE STOVE ENAMEL PAINT INSULATED BETWEEN THE INNER AND OUTER WITH FIBRE GLASS WOOL WITH 1 METRE LENGTH OF SUITABLE CAPACITY 3 CORE FLEXIBLE CORD WITH PLUG AND NON RETURN VALVE PLASTIC/LEAD CONNECTIONS OR PRESSURE RELEASE VALVE (WHERE REQUIRED) Complete including fixing and testing for a week (as required by the Engineer-in-charge) VERTICAL WATER HEATER HSR 30.117 (a) 25 litres capacity
EXTRA FOR FIXING AND JOINTING UNION COUPLING IN G.I. AND W.I PIPELINES. HSR 28.21 (a) 15 mm internal diameter
(b)20 mm internal diameter
(c) 25 mm internal diameter
(e) 40 mm internal diameter
(f) 50 mm internal diameter
DISMANTLING H.C.I SOIL PIPES HSR 30.96 (a) 100 mm internal diameter
(b) 75 mm internal diameter
PROVIDING AND FIXING IN POSITION C.I GULLY TRAP COVER WEIGHING APPROXIMATELY 7.26 KG AND FRAME FOR GULLY TRAP CHAMBER CLEAR OPENING SIZE 300 MM X 300 MM AND OUTSIDE SIZE 330 MM X 330 MM INCLUDING PAINTING THE EXPOSED SURFACES WITH 3 COATS of black bitumastic Superior paint of approved manufacture etc. HSR 30.85
PROVIDING AND FIXING IN POSITION H.C.I GRATING 150 MM X 150 MM FOR GULLY TRAP INCLUDING PAINTING with black bitumastic superior paint of approved Manufacture three coats. HSR 30.86
CONSTRUCTING BRICK MASONRY INSPECTION CHAMBER SIZES AS GIVEN BELOW UPTO 0.60 METRE AVERAGE DEPTH in cement Mortar 1:5 LIME CONCRETE with 40 percent lime mortar 2:3 in foundation Cement mortar 1:2:4 BENCHING 12 mm THICK CEMENT PLASTER 1:2 with a floating coat of 1 mm thick of neat cement R.C.C 1:2:4 SLAB 100 mm THICK/CC/ TOPPING 50 mm THICK WITH 455 MM x 455 MM X 610MM INSIDE LIGHT DUTY C.I. INSPECTION CHAMBER COVER AND FRAME Weight as per I.SI. specification painted WITH 3 COATS OF black bitumastic superior paint complete as per standard design. HSR 29.84 (c) Size 600 mm x 900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping )
Dismantling, disjointing, removal and carriage to stores G.I. Pipe-lines, specials valves and fittings:- HSR 28.48 (a) 15 mm internal diameter pipe line
(b) 20 mm internal diameter pipe line
(d) 32 mm internal diameter pipe line
Providing and fixing in position 15 mm i/d C.P brass bib Cocks of best quality (as required by Engineer-in-charge) HSR 30.75 (a) Bib cock long body
(c) Bib cock
DISMANTLING H.C.I SPECIALS HSR 30.97 (a) 100 mm internal diameter
(b) 75 mm internal diameter
Providing and fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS: 12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow & scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction of Engineer-in-Charge. (Except civil work). HSR 30.119 2000 ltr. capacity
5000 ltr. capacity
Providing & fixing waste pipe 1 1/4 complete fixed in position with 32mm CP jali, complete in all respect (N.S.)
Providing & fixing of sainless steel Hanger for bathroom
Providing and fixing in position CP jet connections for EWC complete including CP plate for jet and PVC connection for jet point complete in all respects.
Providing, laying, cutting, jointing, fixing and testing of CTS SDR 11 CPVC (CHLORINATED POLYVINYL CLORIDE) PIPES (Pressure rating 28 Kg/Cm2 at 230C and 7 Kg/Cm2 at 820C) marked with IS 15778, UV resistant, suitable for cold and hot water supply in concealed works complete with all plugs, clamps including all CPVC plain and brass threaded fittings complete in all respects to the satisfaction to the Engineer-in-charge. This includes jointing of pipes & fittings with one step CPVC solvent cement and by Teflon tape on threaded ends including cutting chases and making good the walls and properly clamped. All termination points for installation of faucets shall have brass terminal fittings. (a) 20mm dia
(b) 25mm dia
(c) 40mm dia
Provindg & fixing CPVC handle valve with joining solvent complete (i) 25mm
Supply of G.I. Peet valve (i) 40mm
Supply of G.I. Union (i) 40mm
Providing and fixing uPVC Pipes 6 Kg / cm2 including all fittings (plain or door type) e.g. bends, junctions, cowls, offsets, access pieces, clamps etc jointing with rubber ring / solvent cement joints, laying of pipes in proper slopes and providing adequate means of supporting / clamping of pipe i/c cutting chase and holes in walls and floors and making good where required.(i) dia 100 mm O.D.
(ii) dia 150 mm O.D.
Supply & Fixing of G.I. Pipes Jindal Hisar Make (B-class medium) including cutting and jointing and including all specials like Tee, Elbow, socket reducers etc. required complete as per the instructions of E.I.C. (i) 20 mm internal diameter
(ii) 40 mm internal diameter
(iii) 50 mm internal diameter
Providing and fixing PVC flush tank 10 ltrs. capacity with all accessories compolete in all respcets. (N.S.)
Providing & fixing C.P. Jali to covers flow traps & P-trap
Providing & fixing uPVC G.O.P. clean out ply.
Providing & fixing S.S. F.C.O. floor clean out ply.
Providing & fixing C.P. Cap flange
Electrical Work items 134 to 152 HSR 31.17 Supply and erection of miniature circuit breaker/isolator 240/415V in the existing distribution board including making necessary connections:- (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii) 6 amp. To 32 amp. (S.P.)
(iii) 40 amp. To 63 amp. (TPN)
HSR 31.40 Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (i) Cable size 1.5 sq mm
(iii) Cable size 4.0 sq mm
HSR 31.41 Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's and ELCBs etc. recessed in wall including bonding to earth with all labour & material required to complete the job in all respects up to entire satisfaction of engineer-in-charge of the work. (v) 4 way TPN & N (Horizontal) 8+12
HSR 31.44 Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work. (b) 25mm dia
HSR 31.56 Providing and fixing modular, type accessories of approved make in existing box including fixing and making necessary connection complete in all respect. 10amp. 1 way switch
20amp. Switch
10 amp. socket
16 amp. socket
Bell push
fan regulator
Blinking plate
HSR 31.57 Providing and fixing GI concealed sheet metal boxes with inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour material required for the job complete in all respect 1 & 2 modules
6 modules
8 modules
12 modules
HSR 31.58 Supply and erection of PVC pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box , iron hooks and ciment concreet etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of work. PVC pipe 40mm dia
N.S. Supply and erection of following sizes heavy duty exhaust fan suitable for opretion single phase 230 volts, 50 Hz AC supply complete with motor, capacitor, louvers / shutters , and fixing on required size 12 mm thick ply sheet etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of work. Make- Orient / Crompton/ havells Exhaust Fan 300mm (12 inches) sweep size 1400 RPM
Fire Fighting Work items 153 to 170 NOTE - The proposed fire estiamte for Block A . External work subject to external estimte subject to NBC 2016. Supplying, installing, testing & commissioning of fire authority approved electrically driven Terrace pump suitable for automatic/manual operation consisting of the following: Squirrel cage, TEFC induction motor suitable for 415 ± 6%V, 3 phase, 50 Hz A.C. supply of suitable H.P. for the above pump running at 2900 r.p.m. conforming to IP 55 pralecting and class 'F' insulation. The motor shall be conform to IS:325-1978 (upto date) Common bed plate for mounting pump & motor of requisite strength manufactured out of M.S. channel as per manufacturer's recommendation. Antivibration (Cushy foot) heavy duty mounting pads as per requirement. Coupling and coupling guard for direct coupling of motor and pump. Technical Parameter of Terrace Pump : Discharge : 900 LPM (11 M3/hr) Outlet working pressure - 35 m/3.5 kg/cm2 Motor kw - 8 kw (Approx.) or as per manufacturer recommendation Material of construction Casing -Vertical SS casing Shaft - SS 304 RPM - 2900 RPM Quantity (each set 1 pump)
Providing ,fixing and commissioning of 1.6mm thick MS door frame 2100x750 x600 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (as per Existing shaft ).
63mm dia single outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make.
First aid hose reel with 25 mm dia, 30 m long rubber hose, ball valve, piping and GM nozzle
Providing ,fixing and commissioning of 63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m long
Providing ,fixing and commissioning of standard short size GM branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked & TAC approved.
Providing and fixing of Fire Axe approved make as per code of practice .
Supply, installation, testing and commissioning ss orifice plates in pipelines to reduce pressure from 8 kg. to 3.5 kg/sq.cm.
Cutting and making good of core cut in RCC slab for hydrant pipe as per approved method /instruction by site incharge dia in mm of core cut (rate as per market)
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately) 50 mm dia.
Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately) 150 mm dia.pipe
Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 in ,structural suport cluding MS pipe fitting for efittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc, including with two coat of primer and paint and complete in all respect as per good practice. (all exposed pipe ) (i) 150 nominal bore (class C)
(ii) 100 nominal bore (class C)
(iii) 80 nominal bore (class C)
(iv) 50 nominal bore (class C)
(v) 25 nominal bore (class C)
Providing and fixing of Water ABCType Fire Extinguisher of Capacity6 KG. (ISI Marked)
Providing and fixing of Water CO2 Type Fire Extinguisher of Capacity 5 kg. (ISI Marked)
MGPS System Work 171 to 183 Copper Pipe: Copper Pipe make - Mehta Tube - Maxflow Rajco Seamless DHP Copper tubes non arsenic, chemical and physical properties in accordance with BS EN 1057 (N.S.) (i) 22mm x 0.9mm
(ii) 25mm x 0.9mm
(iii) 12mm x 0.7mm
Terminal Outlet with Probe (i) Oxygen
(ii) Vacuum
Oxygen Flowmeter with Humidifier Bottle: Make J.K., Mediline Lifeline. (N.S.)
Ward Suction unit 600ml jar, regulator, bracket: Indigenous Make J.K., Mediline, Lifeline (N.S.)
Theature Suction Unit 2 x 2000 ml yars regulator
Horizontal Bed head Panel (Double channel with double aluminium rail): 4 Feet 6 inches long with Direct and Indirect light, provision 04 Nos. Medical gas terminal outlet and provison for Nurses call bell point 04 Nos. of Electrical switch & sockets (J.K., Mediline, Lifeline) (N.S.)
Isolation Valve: - The isolation valve body shall be made of brass with non lubricated (N.S.) Make: - J.K., RB, RN, Conex. (i) 15mm
Alarm System Make Mediline. The alarm should have digital display. The alarm shall be micro processor based (Twin Alarm System) (O2 + Vacuum) Make J.K. Mediline, Lifeline.
Valve Box System Aluminbum body with pressure gauge (N.S.) (02 Gos) Make: J.K., Mediline, Lifeline
PAWAN KUMAR CONTRACTOR
M/s sukhdev and company
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .