Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-Finance 566 135 JAI PRAKASH NAGAR ALAM BAGH LUCKNOW UTTAR PRADESH 226005 | LUCKNOW | UTTAR PRADESH | 226005 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹4.9 L+₹35,461 (7.73%)Accepted-Finance D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L2 | Accepted-Finance Accepted | |
| 3 | L3₹5.0 L+₹37,275 (8.12%)Accepted-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L3 | Accepted-Finance Accepted | |
| 4 | L4₹5.4 L+₹77,150 (16.8%)Accepted-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L4 | Accepted-Finance Accepted | |
| 5 | L5₹5.4 L+₹83,025 (18.1%)Accepted-Finance C 36 DUGGAL COLONY KHANPUR DEVLI ROAD DELHI 110062 | SOUTH | DELHI | 110062 | L5 | Accepted-Finance Accepted |
Tender Value
₹7.1 L
Closing Date
4 Jan 2022, 5:00 pmClosed
AGM (E-E)
AAI, CA, CANTT KANPUR
Decongestion of Terminal Building at Kanpur Airport.SH Electrical Works.
2021_AAI_99633_1
AAI/KP/Engg-E/Electwork/2021
Open Tender
Electrical Works
Works
30 days
KANPUR
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,180
Exempted
20 Jan 2022
27 Dec 2021
5 Jan 2022
27 Dec 2021
4 Jan 2022
27 Dec 2021
27 Dec 2021 - 30 Dec 2021
Amount
Supply of LED 600x600mm type recess mounting indoor Luminaire fitting having power consumption approx 36 Watt and lumen output minimum 100 lumens/w single piece integral metallic CRCA powder coated body, complete with electronics power driver, all its accessories with high transmitivity diffuser for uniform glarefree light distribution suitable for 230V, 50 Hz power supply, Average life of LED > 50000 burning hrs (lumen depreciates power factor > 0.90, and having minimum five years guarantee for the complete LED fixture as required.
Supply of XLPE insulated PVC sheathed galvanised flat steel strip armoured aluminum conductor cable of grade 1.1 KV, of following size confirming to IS: 7098/Part-I(1988) with up-to date ammendments etc. complete as required. 3.5 x 35 sq.mm
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following rating, single pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6-32A
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED Fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 35 sq.mm
Dismantling and re-installation of existing MCB DB at new location of required as per direction of Engineer-in charge.
Dismantling and re-installation , testing & Commissioning of following capacity Split Air / Tower AC units including Indoor/Outdoor unit complete as required. 1.5 TON Split AC
3 TON Tower AC
Supply, installation, testing, & commissioning of suction/discharge copper pipe line 1.5 TR Split, 3.0 TR Tower Air condition unit including brazing nitride rubber installation etc. complete as required. Copper Tube size 1/4"
Copper Tube size 1/2"
Copper Tube size 3/8"
Copper Tube size 5/8"
copper wire 4 core X2.5 sq.mm
SITC of 3.0 TR Tower air conditioner fitted with Rotary type compressor operating on refrigerant R32, Control box of indoor unit shall withstand flame retardant, cooling capacity (W) : Min. 10400 W, total input minimum power 3200 W and air flow volume (max/min)CMH/CFM 877/704, suitable for wall mounting with cordless remote, suitable for operation on 415V, 50Hz, three phase A.C. and suitable size copper pipe, insulation, pvc drain pipe, control cable, supporting structure of outdoor unit, refrigeration gas for extra running pipe civil work for connect including all mounting arrangements on wall/floor of outdoor & indoor units and capable of performing following functions. Cooling, Heating, Air Circulating, Filtering, Ventilation etc. complete as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 63 A (three phase and neutral), 415 volts MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Anoop Refrigeration
Awasthi Electric Works
Ganga Enterprises
ANU ENGINEERING CORPORATION
Industrial Traders
Yash Energy Pvt. Ltd
ANUKOM ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .