Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.4 CrAccepted-AOC 603 QUANTUM TOWER 6TH FLOOR RAMBAUG LANE S V ROAD MALAD WEST MUMBAI 400064 | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | ₹17.4 Cr | 1 | Accepted-AOC Accepted |
| 2 | Not Admitted-Fee/PreQual/Technical B 507 KAILASH BUSINESS PARK PARKSITE VIKHROLI MUMBAI 400079 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400079 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical 65 1ST FLOOR RAJA INDUSTRIAL ESTATE P K ROAD MULUND WEST MUMBAI 400 080 | MUMBAI SUBURBAN | MAHARASHTRA | 400080 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹19.3 Cr
EMD Value
₹9.6 L
Closing Date
11 Jul 2023, 6:00 pmClosed
E.E. P.W. Division Panvel
E.E. P.W. Division Panvel
Renovation of Konkan Bhavan Administrative Main and Annexe building at Navi Mumbai.
2023_PWR_920914_1
PD/AB/TC e-Ten Notice No.51 for 2023-2024
Open Tender
Civil Works
Panvel
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
₹9.6 L
C.E. P.W. Region. Konkan
24 Jun 2024
29 Jun 2023
13 Jul 2023
29 Jun 2023
11 Jul 2023
29 Jun 2023
4 Jul 2023
Amount
Civil Work Removing Urinal Pans or W.H.B. with frame including disconnecting the sanitary and water supply connections. removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials out side.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed including of throwing the unserviceable materials out side.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. Complete
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing second class Burnt Brick masonry with conventional / I.S. Type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing frame with/without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering rounding rebating iron holdfast of size 300mmx 40mmx 5mm with oil painting, etc. Complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing in position HCRM/CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawing sand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing & Applying Dura Clean-WR-for cleaning theTMTbars,steel structure etc.of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles (using other mechanical /manual means) and apply on prepared surface of Dura Cap 2 coats corrosion preventive coat on prepared TMT bars, steel structure, metal surface etc. to protect it from corrosion etc. as per manufacturer's specification (using ot her manual/mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying Kelox R 101 (Resin) + Kelox H 404(Hardner) water misible epoxy of approved make for bonding old concrete to new mortar after mixing slowely in predefined ratio and applying by brush on the surface,when it stacky then apply the mortar complete as per specification and as directed by engineer-in-charge.Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying 30 mm thick self curing Ceremic Polymer Micro concrete of approved make having Compressive strength above M30, non shrink, impermeable, filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface, including honeycomb area(using manual/mechanical means).Mixing mortar of Nicosil C80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying and finishing by manual trawelling, curing after curing initial setting time etc, as per manufacturers specification etc. complete as per specification and as directed by engineer-in-charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs.500/- stamp paper.(Bond coat mentioned below is to be done before coating)
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with water proofing compound @ 1 Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1Kilogram/bag of cement grouting and finishing the to player with 20 mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc.complete
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS.15622-2006 (GroupBla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30cmx30cm and confirming to IS 15622-2006(Group-BIIA) for anti skid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown stone partition with rounding the edges etc. complete. A) Both side polish
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete. One side polish
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall making good the damaged surface , testing etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying Two coat of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying priming coat on concrete /masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. Complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing chromium plated towal rod 16 mm dia and 75 cm. in length including all accessories complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing single leaf panelled door shutter without fanlight and shutter 35 mm thick as per drawing consisting of T.W. top rai lsize 100 mm x 35 mm and bottom and lock rail 200 mm x 35 mm insert panel 12 mm thick commercial ply faced T.W. particle board with phenol formal dehyde synthetic resin (Generally confirming to ISI 3097) excluding frame, including stainless steel fixtures fastening and T.W. beading at junction of panels inserts and as instructed by the Engineer in charge including 3 coat so foil painting etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Supplying Hydraulic door closer etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and laying telephone black/ Amba White/ Cadbury brown/ Rubyred/ Ocean Brown granite stone of 18 to20 mm thick for door frame/ dado/ window boxing etc. On C.M.1:6 including filling joints with polymer base filler nosing/ moulding the sharp edges wherever necessary, curing, etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
1st Floor
2nd Floor
3rd Floor
5th Floor
6th Floor
7th Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C.soilvent /waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
Providing and fixing 110 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black /Amba White /Catbary brown /RBI red/ Ocean Brown granite stone for tread sand risers of step sand stair cases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and laying Vitrified matt finish - size 895 to 900 mm* 895 to 900 mm size of 10 to 12 mm thickness ans confirming IS 15622-2006 of approved make shade, pattern, double charge for flooring in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k=0.052-0.057 w/mK, Colour White, Fire Performance UK Class 0/ Class1 (BS476pt 6&7) in module size of 600 x 600 x 20mm, suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I. channel on XL 2 Clip having a web height of 32mm with15mm wideT-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7Kgs/M2 and minimum pull out strength of 100Kgs..The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used to gether should carrya 10 year warranty products approved as per GRIHA and BS 476 etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamp sand stair case system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and /or applying chemical and removing it there after.The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, where ver required, iffeasible, for inspection of work at required locations with essential safety features forthe workmen etc.,complete as per directions and approval of Engineer-in-charge. Note:-(1) The elevational area of the scaffolding shall beme asured for payment purpose. (2)The payment will be made once only for execution of all items for such works.
Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.
Providing and erecting steel tubular props of required height upto 14'feet, Lhead or flat head braced at center and supporting a continuous 2"x3"wooden runner, resting on wedge and block minimum capacity 3Ton to support the structure provisionally during repair and jacketing etc. and maintaining the min position till all required item are complete.The props are erected in perfect vertical in plumb taking/transferring the load equally/uniformly.The location of every prop should be one over another floor and it should not be eccentric.The tightening of every props hould be uniform to all props to strain the building uniformly, removing the same as and when directed by structural engineer/SiteEngineer.The works houldbe carried out with all the safety measure slike helmet,safety belt and adequate labor insurance under the supervision of qualified supervisor and remove the same completion of work etc. complete.
Providing and fixing construction three layer monofilament safety net including first layer of machine knotted 5mm braided Rope with100mmx100mm mesh size, second layer of machine knotted 2.5mm braide drope with25mmx25mm meshsize, third layer of mono filament stabilize rand net with welding/grinding splatter resistance, border rope of 12mm maximum including thecord of 12mm maximum attower cornersat 1.50 meter long at every1.50 mete rdistance including require size and as per specification and certificati on approved including testing criteria for safet ynet EN1263-1including droptest (dynamictest)and energya bsorption test(En-1263-1:2002)and asper instructions and approved of the Engineer - In - Charge (Horizontal Safety Net)
Repairing of honeycombed or spilling area by chipping out the damaged spalled or honeycombed portion of concrete upto rusted rebars, cleaning of all rust, scale and loose materials, scaffolding, compressed air machinery etc. complete. (item includes use of aircompressor, chipping machine and scaffolding for height 8 to 10 meter).
Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide 'Glycel' (iso proplamine salt of glyphosate) or other chemical as specified by the Engineer in charge etc. complete.
Providing and Fixing of 12 mm nozzle in the crack portion @ 500 c/c including material, labour complete in all respect.
Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer incharge conforming to IS9077. The rusted surface shall become blackish non rusted colour.After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer-Methyl2-methyl propenoatecopolymer with another enoate as approved by Engineer incharge onentiresurface. Mix 1Kg of acrylic polymer with 0.5Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents as approved by Engineer incharge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20N/mm2 in 1 day and 30N/mm2 in 7days ) by adding 13- 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer incharge per 25Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item) (Upto 15 mm thickness at a time).
Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another innovate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, formaldehyde based polymer with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item) (15-30 mm thickness at a time).
Re-casting of bracket with micro-concrete and 10 mm agrregate (1:1) with leakproof shuttering all manpower and equipments complete in all respect
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
Providing and grouting the holes by Poly Ceramic Cementitious i.e NicGrout G 06 + 53 grade cement material of as per requirement to reduce the porosity of concrete / Masonry structure and to increase the strength of structure using grouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge.
Supplying, Drilling/Cleaning hole and injecting Hilti make ETA Approved HY-200-R chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. HY200 -10 mm dia 200mm depth
Strengthening structural elements by providing & fixing CARBON FIBER (Make Sika or BASF or FOSROC) Surface preparation:Grinding concrete substrate,cleaning it with wire brush removing oil ,laitance if present ,rounding sharped gestomin 25 mm radius etc. complete. Profiling: providing & Applying compatible Mbrace primer on prepared substrate,Filling the holes and un even surface with high strength epoxy putty etc. complete IF Required.Wrapping:Providing & Applying first coat of Saturant, cutting the carbon fiber sheet to size, wrapping the fiber sheet to structural element at desired orientation using tamping roller to avoid any airvoids etc.complete. Sand pasting: Providing & Applying second coat of Saturant after min.12hrs,rectify air voids if any paste the rives and on it to make surface rough to take any further finishes (Mode of measurement:Per sq.mt of Mbrace CF 400 sheet applied and not surface area of Concrete application & Quantity will be measured including wastage) The rate includes all type of material,application,equipment & scaffolding etc complete .Rate is applicable for all height & level.
Clean the existing surface / terrace thoroughly to remove dirt, loose particles, laitance etc. For emergency waterproofing of existing terrace. Use a vacuum cleaner or high pressure jet or wire brushing as per requirement. Examine the surface closely for any cracks. Fill it with acrylic polymeric non-shrink crack filler putty as approved by Engineer in charge a pure aliphatic, acrylic, polymer modified ready to use paste. After filling, allow the surface to dry for atleast 24 hrs. If the depth of the crack is more than 2-3 mm apply in layers at intervals. Moisten the surface with a water jet one day prior to the application of waterproofing coating. Mix 1 part of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) membrane as approved by Engineer in charge and 1 part of grey cement by weight using a low speed mechanical stirrer to form slurry lump free consistency. Apply this as a primer coat of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) membrane as approved by Engineer in charge. Apply the same slurry by roller at 24 hrs interval between the applications of each coat. Extend the coating to parapet walls. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of pure enoate based polymer titanium dioxide based 2-(methoxycarbonyl)-1-propene-butyl-2 propenoate (TMPBP) and 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) of waterproof coating as approved by Engineer in charge on surface. Ensure that no pinholes are let untouched. Allow the membrane to cure for 24-48 hours. Single Component, UV Resistant, Elastomeric, High Build Waterproof Coating (Confirming to DIN 1048) should have following minimum properties: 1) Elongation % (ASTM D 638): @ 400% 2) Tensile Strength (ASTM D 412): 150 psi 3) Water Permeability (DIN 1048): Zero 4) Solids: > 65% 5) pH: 8.5 - 10.5
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete.
Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in- charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete.
Excavation for foundation in hard murum including removing the excavated material up to distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Liftupto1.50m) By Manual Means
Providing dry /trap /granite /quartzite /gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
Providing and laying Cast in situ /Ready Mix cement concrete in M15 of trap /granite /quartzite/ gneiss metal for bed blocks, foundation block sand such other items including bailing out water, Steel centering, formwork, laying /pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honey combed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro process or based PLC with SCADA enabled reversible Drum Type mixer /concrete Batch mix plant (Pan mixer) etc.complete.With fine aggregate (Crushed sand VSI Grade)
Providing and laying concrete pipes of I.S.NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half roundG.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concretewith R.C.C. Cover medium duty 140 Kilogram with frame etc complete.
Providing & constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover 75 kg with frame fixed in cement concrete.
Supplying of Teak wood batten 25 mm * 12 mm.
Supplying of Jali fly proof.
Supplying of Alluminium Screw 32 x 6 mm, 25 x 6 mm.
Supplying of G.I.Screw 25mm
Supplying of Nails iron all size.
Supplying of Fevicol marine.
Supplying Carpenter II Class Skilled.
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
7th Floor
staircase
Removing any kind of earth, murum, building debries from building premises upto 15 km distance including loading, unloading etc. complete.
Providing protection of unexposed old reinforcement on non spalled concrete by insertion of sustained release corrosion inhibitor caplets like POWRTHROW sustained release Corrosion inhibiting caplets of to protect both anodic & cathodic sites and shall reduce to reduce corrosion potential Ecorr by minimum 80 mV in conductive medium, by drilling 20 mm holes into the concrete at a depth of 25 mm and inserts to be filles by EPCO-PCPutty. Caplets shall inhibit corrosion inhibition efficiency of 98% (when added 0.03% by weight) against control sample evaluated by Tafel polarization method. Depth of penetration for effective corrosion protection shall be 120 mm and film formation of 20 Microns as evaluated by CSIR-CECRI Karaikudi.
Providing internal dash coat plaster in cement morter 1:6 with broken brick pieces to existing surface in all positions to maintain uniform thickness to recieve fresh plaster including scaffolding and curing complete. For External Plaster
For Gr Floor Internal
For First Floor Internal
For Second Floor Internal
For Third Floor Internal
For Fourth Floor Internal
For Fifth Floor Internal
For Six Floor Internal
For Seventh Floor Internal
Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing 22 B.W.G. plain FRP sheets on top of weather shed, including scaffolding, fixing by means of nut and bolts or as directed etc. complete. (Brackets of 70 x 45 mm to be paid separately)
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete
Royalty Charges Reimbursement of Royalty. Royalty for sand
Royalty for other material
Material Testing Carrying out Standard Consistancy Fineness, Specific Gravity, Setting Time (Iniatial and Final), Compressive Strength, Soundness test on cement in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results.
Carrying out Water Absorption, Specific Gravity,Impact Value, Crushing Value test on Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results
Carrying out Sieve Analysis.test on Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results
Carrying out Abrasion Value..test on Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results
Carrying out Flakiness Index & Elongation Index test on Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results
Carrying out Soundness. test on Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results
Carrying out Fineness Modulus ( Sieve Analysis ), Silt & Clay Content test on Fine Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results.
Carrying out Chloride & Sulphate Content.test on Fine Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results.
Carrying out Silt Factor.test on Fine Aggregate in Govt. P.W.D. laboratory as per relevent b.i. standards and submitting test results.
Carrying out Water Absorption (Set of 5 Bricks), Compressive Strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test on Bricks in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Water Absorption, Modulus of Rupture (Set of 6 Tiles) on Ceramic / Vitrified tiles in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Compressive Strength OF C.C. Cube (Set of 3 cubes). on CONCRETE in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Compressive Strength.( Set of 3 Cubes) on MORTOR in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out PH Value, Sulphate & Chloride Content. on Water in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Knife Test, Adhesion Test, End Immersion Test on FLUSH DOOR in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Thickness, mass per running meter and powder coating test on Alluminium section in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Weight per running meter,Diameter of pipe & wall thickness of pipe, test on P.V.C. PIPES (NONPLASTISIZED) in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Glass bead contents & grading analysis. test on PAINT / THERMO-PLASTIC PAINT in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Reflectance & yellowness index. test on PAINT / THERMO-PLASTIC PAINT in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Flowability.(Percentage residue). test on PAINT / THERMO-PLASTIC PAINT in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Softening Point. (Ring & ball method).. test on PAINT / THERMO-PLASTIC PAINT in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Drying Time. test on PAINT / THERMO-PLASTIC PAINT in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Upto 16 mm (Set of 3 Bars) test on steel in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Upto Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) test on steel in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Water absorption, Specific gravity test on Kadappa in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Water absorption, Specific gravity test on Granite in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Density, Moisture Content. test on WOOD in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Carrying out Crushing Value/Compressive Strength, Water Absorption & Specific Gravity, test on STONE/ RUBBLE in Govt. P.W.D. laboratory as per relevant b.i. standards and submitting test results.
Electrical Works Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit [1-2-1]
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No WG-MA/CON. ( for existing solar system wires ) [1-2-5]
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No WG-MA/CON [1-2-8]
Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No WG-MA/BOX [1-2-11]
Supplying and erecting PVC box trunking of size 75x50 mm. with accessories on wall/ceiling as per specification No WG-MA/BOX. [1-2-12]
Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No WG-MA/BOX. [1-2-13]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW [1-3-2]
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW [1-3-3]
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW [1-3-3]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV ( for octagonal pole street light) [1-3-14]
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-15]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. [1-6-6]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. [1-6-31]
Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. [1-6-44]
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW [1-7-19]
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW [1-7-20]
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW [1-7-26]
Dismantling the existing light fan bell clock independent plug point wiring including circuit mains of all types along with accessories etc. complete as per specification No WG-DM/PW [1-13-1]
Dismantling the existing Telephone / LAN / WAN / TV cables and wires of all sizes along with casing-capping / conduit complete as per specification No WG-DM/PW [1-13-2]
Dismantling the existing aluminium/copper mains sub-mains wiring upto 10 sq.mm. along with accessories etc. complete as per specification No WG-DM/PW [1-13-3]
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W. [2-1-13]
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2. [2-4-2]
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-4]
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 6600 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-5]
Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing having system lumens output of Min. 5000 Lumens min. efficacy of 100 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-270V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. ( for Building illumination purpose above Ground Floor with cable on wall ) [2-4-13]
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser having system lumens output of Min. 800 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 2 kV Life class of 25 000 Hrs. at L50B50 including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. ( 16 Entrance Side Gate -- 20 Garden Area + Front and Left Side area of Main Buiding ) [2-4-20]
Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser having system lumens output of Min.4500 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 2 kV Life class of 30 000 Hrs. at L50B50 including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. ( Back Side Gate 2/ each x 2 gates) [2-4-21]
Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing having system lumens output of Min. 500 Lumens min. efficacy of 85 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 100-240V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L50B50 including driver salt spray tested for 500 Hrs. including making of recess of appropriate size for flushing into surface with 2 Year warranty as per specification No FG-ODF/FLS2. ( at entrance -- Jayanti Celebration Place with 2 x 2.5 sqmm arm cable above ceiling) [2-4-22]
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB [2-7-4]
Supplying and erecting Street light bracket for erection of side entry fitting on pole with 25 mm. dia. ‘B’ class G.I. pipe of required length complete as per specification no. FG-BKT/SLB ( for Solar Highmast - DC Street Light of 25 W) [2-7-10]
Supplying and erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base. [2-8-9]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. [2-10-13]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. [2-11-4]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (1mtr/each x 166 Nos )
Dismantling existing fluorescent fittings of any type & size. [2-12-1]
Dismantling the existing W.T. fluorescent fitting / S.V./ M.V. / M.H. lamp /LED fitting from wall with brackets and making the site as original complete. [2-12-2]
Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V. / M.H. lamp /LED fitting from pole with brackets complete. [2-12-3]
Dismantling the existing ceiling fan /exhaust fan / cabin fan / bracket fan complete with accessories G.I. down rod frame etc. and making the site clear. [2-12-4]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22 [3-3-9]
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire two indicator lamps dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system. [3-5-2]
Supplying and erecting candle filter with filter pot for water cooler. [3-10-36]
Supplying and erecting connector pipe for candle filter of water cooler. [3-10-37]
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC ( Primary connection to Solar panel cleaning unit from terrace water tank) [4-2-19]
Supplying, installing, testing and commissioning of 40 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter proper base plate canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB MCB etc. wiring up to solar Inverter in casing and capping display board sign board two distinct earthing lightning arrester liaisoning charges remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
Supplying, erecting, testing and commissioning of 30 kW DC Electric Vehicle Charger (suitable for 4 wheeler) having minimum IK08 & IP 54 Protection suitable for three phase 415V AC 50Hz incoming supply and 1 nos 30kW output charger interface CCS2 with 200-500VDC supply Interlocking arrangement with minimum 4 meter charging cable length 5 LCD Touch Screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1% One hour battery backup for communication emergency push stop button. User interface by mobile application/QR Code/RIFD Card/Password Login with payment options and having short circuit over & under voltage input phase reversal surge protection earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty confirming to IS 17017 Series as per specification [4-7-4]
Providing yearly subscription of payment gateway option for AC/DC EV Charger CMS (Charger management software) system for billing and payment gateway along with mobile application /android/IOS base app to facilitate charging CMS should have ISO/IEC 27001 2003 certification. [4-7-5]
Supplying and installing of Solar PV Module cleaning unit for 40 KWp (New System) consisting of nozzles spray necessary pipes valves post electronic panel board concealed with weather proof cabinet spreading water periodically for removal of dust related motor pump controller timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area).
Supplying and installing of Solar PV Module cleaning unit for 50Kwp ( for existing Solar roof top system) consisting of nozzles spray necessary pipes valves post electronic panel board concealed with weather proof cabinet spreading water periodically for removal of dust related motor pump controller timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area).
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying, erecting and marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking DPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-6]
Supplying, erecting and marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-7]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying, erecting and marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
Supplying, fixing, and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-25]
Supplying and erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
Supplying and erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5]
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-7]
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-15]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB ( 1 for DB & 2 for Cubical Panel+ 8 for maintenace + 2 for solar system) [5-5-1]
Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
Providing and erecting 4 Pole MCCB 415V 400A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [5-5-4]
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1]
Supplying, Erecting and Commissioning of 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-2]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Supplying, Erecting and Commissioning of 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6]
Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A [5-10-27]
Supplying and erecting terminal spreaders suitable for 4 pole up to 100A MCCB (Set of 8) [5-11-6]
Supplying and erecting terminal spreaders suitable for 4 pole above 100A up to 250A MCCB (Set of 8) [5-11-7]
Supplying and erecting terminal spreaders suitable for 4 pole above 250A up to 400A MCCB (Set of 8) [5-11-8]
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB. [5-11-15]
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB. ( solar PV system MCCB ) [5-11-17]
Dismantling Dismantling the existing switchgears DB and bus bar of any size complete with/ without board or angle iron frame [5-12-1]
Dismantling Dismantling any type of unserviceable feeder pillar switch gear panel capacitor panel metering panel bus-bar panel electronic equipment panel etc. and making the site as required Approx. size (up to 200cm. x 90 cm x 45 cm and above) - Big Cupboard [5-12-5]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. ( 1.5mtr x 1.6mtr x0.4mtr -- Separte sheet attched) [6-1-1]
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010
Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 ( for all meter room panel Boards Passage Duct Doors [6-1-15]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard [6-1-20]
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars 500V 300A having 40mm (Width) X 5 mm (Thickness) with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display external CT operated calibrated for suitable to operate on 500V 0 to 1000A having accuracy class of 0.5 AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. [6-3-7]
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. [6-3-8]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
Supplying and erecting 50 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-3]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( from main panel to APFC Panel ) [7-1-17]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Re-erecting PVC / XLPE armoured cable 2 to 4 Core up to 50 sq. mm. on wall with necessary material & G.I. earth wire. ( FOR DISMANTLED cable for civil work at avrious places needs to re-erect ) [7-1-41]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (280 - Street Light Fittings on wall 155 - Terrace 316- Ground Floor 260 for pillar Highligher + 240mtr for Bollards at 3 diff places) [7-2-9]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( FROM TPNDB to each SPNDB) [7-2-10]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( for Temporary illumination facility purpose) [7-2-11]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( for Dewatering Pump Connection in main passgew - at Four Isolated Places) [7-2-15]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( for Decorative poles- on main entrance raod & in garden area = 288 mtr + 126mtr for flood light on wall for main buidling facade lighting ) [7-2-31]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( for octagonal poles = 516 mtr ) [7-2-32]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( from GROUND Floor TPNDB to upper TPNDB's) [7-2-33]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( 126mtr TPNDB to Pump room )136mtr for 30KW Charging station + 30mtr for 40KWp new Solar system on Annex Byuilding) [7-2-34]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 25 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( Main common meter panel to DB at GB for Distribution of Common wiring ) [7-2-35]
Providing and erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm. with necessary material as per specification No. CB-JT/LT [7-4-2]
Providing and erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm. with necessary material as per specification No. CB-JT/LT [7-4-3]
Providing and erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq. mm. with necessary material as per specification No. CB-JT/LT [7-4-4]
Supplying and erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-2]
Supplying and erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-3]
Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4]
Supplying and laying (including excavation) reinforced cement concrete pipe of IS 458 2003 NP-2 class of 250 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete. ( for connecting meter rooms - for common meters cable connection) ( from Main common meter room to Each meter in two building ) [7-6-7]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. ( 248 mtr for Decorative pole cable & 341 for Octagonal pole+ 120 mtr for EV charging + 240 Bollard Lights ) [7-6-9]
Supplying and erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP [7-8-1]
Supplying and erecting FRP box of size 150mm x 125mm x 100 mm 2.7 mm thick complete on pole/wall as per specification No. CB-SB ( Street Light on terrace - 16 Street Light on Wall at Back Side of Main Building- 14 Gate Light - 4) [7-8-8]
Supplying and erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification No. CB-CL/AL [7-10-4]
Supplying and erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification No. CB-CL/AL [7-10-5]
Supplying and erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification No. CB-CL/AL [7-10-6]
Providing and erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. ( for Vertical Cable Tray & Meter Room Tray) [7-11-11]
Dismantling the existing cables of all types & size up to 10 sq mm. [7-12-1]
Dismantling the existing cables of all types & size above 10 sq mm up to 50 sq.mm. [7-12-2]
Dismantling the existing cables of all types & size above 50 sq mm. [7-12-3]
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL (22 for Street Light & 2 for Solar Highmast) [8-2-12]
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21]
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22]
Dismantling the existing pole up to 6 m height with brackets clamps insulators stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. [8-7-1]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP ( 2 for Street light control pannel 2 for Solar Highmast 2 for Cubical panel ) [9-1-1]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP ( 2 for each meter room x 4 meter rooms ) [9-1-3]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP ( for decorative poles = 22 Octagonal Pole = 22) [9-1-4]
Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. (40 x 5mm AL. Bus Patti - 0.538 kg/m )
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. ( Octagonal pole= 1.5mtr x 22 Nos = 33mtr + Decorative poles 22 x 1.5mtr = 33mtr Total = 66mtr x 0.596kg/m= 39.33 Kg For Solar System = 130mtr x 0.596kg/m = 77.48 Kg for existing solar system earthing system 165mtr x 0.596kg/m = 98.34 Kg) [9-2-3]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP ( for Dewatering purpose 4 different places) [12-3-1]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 36 to 14m and discharge from 225 to 1680 litres. per minute& pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-3]
Supplying and erecting D.O.L Starter suitable for 415 V 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P. ( for 4 Nos Dewatering pump) [12-4-2]
Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( for 4 Nos - Portable Dewatering pump ) [12-4-9]
Supplying and erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. ( for main water pumps of 7.5 HP) [12-4-10]
Supplying and erecting automatic control panel for 3 Ph 415 volt A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP S.P.P. Combined ammeter/voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc. [12-4-18]
Dismantling the existing Monoblock / open well submersible water pump set centrifugal type without pipeline complete and making the site clear. [12-7-1]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. For Bollards Foundation (0.25mx 0.25mx 0.30mtr = 0.019 Cum x 36 Nos = 0.684 Cum [16-1-6]
second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1 6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually striking joints on unexposed faces raking out joints on exposed faces and watering etc. Complete.
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). [16-2-4]
Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation fixing provided nut bolts with the help of template duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole). -- DECORATIVE POLE OF 3MTR [16-3-8]
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9]
Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. ( for Open well sub mersible water pumpset) [16-5-7]
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. ( for Portable water pumpset - for dewatering purpose) [16-5-18]
Supplying and erecting non return valve 65 mm dia in position made of gun metal complete. [16-6-22]
Supplying and erecting electronic type driver for indoor LED 10W-18W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. [2-3-20]
Supplying and erecting electronic type driver for indoor LED 5W-9W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. [2-3-19]
Supplying and erecting electronic type driver for indoor LED 25W-40W fixtures suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. [2-3-22]
Supplying and erecting electronic type Driver for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. [2-7-24]
Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. [2-7-25]
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. [1-5-7]
Supplying and erecting modular type D.P. switch 32A with indicator duly erected on provided plate and box with wiring connections complete. [1-6-8]
Supplying and erecting electronic ballast pf > 0.9 or transformer suitable for T5 lamp upto 28 W as per specification No. FG-FG/AS1 [2-3-3]
Supplying and erecting electronic ballast pf > 0.9 or transformer suitable for FTL upto 40 W as per specification No. FG-FG/AS1 [2-3-4]
Supplying and erecting condenser 4 microfarad for fluo. Fitting as per specification no FG-FG/AS7 [2-3-16]
Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22]
Supplying and fixing MC4 Connector (NON CSR) ( for re-erection system of 50KWp solar roof top system) [1-13-4]
Supplying & erecting DC wire 6sqmm with termination in MC 4 Connector. (NON CSR_) [39-1-3]
NEXUS N2174 Beam / Pillar highlighter Light 48 watt with 200 Lm and 15 degree beam angle CRI 80 Input 100 - 240V Power Factor >0.95 Safety Type IP65 Class1 (Colors Red Green Blue White arm white) for main building pillars ( NON CSR) [2-2-5]
Dismantling existing solar roof top system of 50KWp with GI Structure DC wires Connectors etc and siffted to safe location as per instriction given by site engineer without damage and re-erecting the same i.e. 50 KWp solar roof Top System at same location with existing structure connectors wires etc. after Civil complition of Water proofing work by Civil Dept with complete duly connections as per requirement to run the system satisfactorliy on provied foundation (if required)
Supplying & Installing auto glow (Viewing up to 15mtr length) Signages like Exit Fire Hydrant Fire Extinguisher Fire Exit Fire Door Fire Hose Box etc. (Size 300mm x 100mm) (NON CSR) [13-16-1]
Supplying and erecting DC LED Flood light fitting of 24V 25W including first 6 hr. full intensity light output and following 6 hr. with half intensity light output with lumen < 3750 colour temp 5500K - 6500K colour redering index PWM charge controller efficiency >90% LED driver efficiency >90% Duty cycle first six hours 100% Rest 50% light LED external optics 145X90 degree street light lens class IP 66 charge controlller methodology - three stage battery charge monitoring algorithm maximum charging current 20Amps short circuit protection battery over charge protections battery deep discharge protection solar panel dusk to dawn operation NTTV- 4V DTTV-6V battery low load disconnect voltage 22.4V battery full load disconnect voltage 26V battery constant voltage set point 29.4V LED Indication- green off battery not charging PV low green on battery charging green flashing battery full Red off battery not discharge Red on Battery discharge load disconnect overall dimension- 255mm X 90mm X 60mm overall Weight- 1Kg. and above housing of die cast aluminium alloy and heat sink extruded aluminium complete.(5 Year Warrantee) (Non CSR item Sanctioned by S.E. PWD Elect Mumbai Cricle vide Letter No 135/2022-23 Dt. 27/06/2022 Est. No. 1560/2022-23). [30-1-35]
Supplying installing testing and commissioning Of Lifepo4 battery with capacity of 24V- 78 Ah with 4S 15A BMS Cell having duty cycle < 3000 suitable to charge lithium cell with necessary wiring connections With IP 65 alluminium cabinet with stand and nut bolts complete. ( Nominal Voltage 24V Nominal Capacity - 75Ah Stored Energy- 1.8Kw Cycle 0.5C 80% DOD <3000 Charge Voltage 29.2 charge mode - CCCV Standard charge current- 15 amp rapid charge current- 37.5 standard discharge current- 15 max charge current- 75 amp low voltage cutoff- 21.2 casing material- Alluminium MC4 connector charge temp range - 0-45C Discharge temperature range - 20- 55 C Storage temp - 20-45C Weight - 17Kg. (5 Yrs Warrantee) (Non CSR item Sanctioned by S.E. PWD Elect Mumbai Cricle vide Letter No 135/2022-23 Dt. 27/06/2022 Est. No 1560/2022-23). (NON CSR) [30-1-36]
Supplying installing testing and commissioning of Solar Panel Comprising high efficiency poly - crystalline photovoltaic cell 250Wp 24V with necessary clamps and module frame on existing structure complete. Module Volt(V)=24 No.of cells in series-60 cell size(mm)=156.75 cell size tolerance±1% Module size(LxWxH) in mm (1640x991x35) Voc(V)=37.1 Isc(A)=8.9 Pmax( W)=250 Vpm(V)-31.15 Ipm(A)=8.05 Efficiency(%)=15.4 Electrical tolerance (1%) =2 Temperature coefficient of open circuit voltage(beta)/C=0.28% Temperature coefficient of short circuit current(alpha)/°C=0.005% Temperature coefficient of power(gamma)/°C=0.38% Nominal operating cell temperature=45°C +2°C operating temperature range from -40°C to +85°C Junction box connector IP68 Waterproof PPO and MC4 Compatible. Module weight (Kg) =20.(Non CSR) [30-1-37]
Supplying & erecting of Decorative Pole of made up of Cast Iron of ATSM A48 Class 25 of 3.21m with double arm all pole sections are welded using special v groove technique by certified welders using high end MIG welding processes the foundation bolt holes in the base plate are designed to be elongated for fine adjustments / alignment of the pole during installation. Base plate made of steel grade E250 & foundation bolt - 4 Nos of grade 4.6 of size M16 x 500mm with 2nuts & 2 washers each.having CE- Conformity mark. Pole is coated with zinc rich primer and finished using environmentally stable polyurethane based paint / Pure polyester powder coated of Graphite grey Anthracite grey or Black as per direction of engineer in charge with surface mounted with base plate and fitted on provided foundation similar to KP-4902 Nene Fortuna Lighting Pole. [32-1-108]
Supplying & erecting of Decorative Pole of made up of Cast Iron of ATSM A48 Class 25 of 3.35m with tripple arm all pole sections are welded using special v groove technique by certified welders using high end MIG welding processes the foundation bolt holes in the base plate are designed to be elongated for fine adjustments / alignment of the pole during installation. Base plate made of steel grade E250 & foundation bolt - 4 Nos of grade 4.6 of size M16 x 500mm with 2nuts & 2 washers each having CE- Conformity mark. Pole is coated with zinc rich primer and finished using environmentally stable polyurethane based paint / Pure polyester powder coated of Graphite grey Anthracite grey or Black as per direction of engineer in charge with surface mounted with base plate and fitted on provided foundation similar to KP-4903 Nene Fortuna Lighting Pole. (NON CSR) [32-1-109]
Supplying & installing aesthetically designed sturdy construction post top luminaries of 30W of size ?425 x 635 with lumens not less than 4500. The luminaries comprise of specially contoured spun aluminium top cover & Die Cast Aluminium Base with supporting arms made of MS hot dip galvanized. The fittings top having Aluminium Casting crown attachment added for aesthetics. Non yellowing UV stabilised V clear acrylic / V clear polycarbonate diffuser. Luminaries suitable for mounting on 50 mm OD pipe. Cable entries for through-wiring of mains supply cable Integral constant current power supply - Prewired with LED driver which having power factor >0.95 THD <10% Surge protection - 4KV & efficiency >85% and suitable for operating on 240V 50Hz single phase ac supply. Light Color of WW NW or CW & luminaries having powder coated Graphite Gray/ Jet Black & anthracite Grey. The Fittings color same as pole color or as per directions by engineer in charge similar to KL-5373 Imperial Mini
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & for fixing of cable tray - Rods/ angel supports with necessary fastners in approved manner. (NON CSR)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid