Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹32.4 L Quoted ₹32.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹34.5 L+₹1.7 L (5.08%)Rejected-Finance | ₹34.5 L+₹1.7 L (5.08%) | L2 | Rejected-Finance Higher Bidder |
| 3 | L3₹37.6 L+₹4.7 L (14.4%)Rejected-Finance | ₹37.6 L+₹4.7 L (14.4%) | L3 | Rejected-Finance Higher Bidder |
| 4 | L4₹38.0 L+₹5.1 L (15.4%)Rejected-Finance | ₹38.0 L+₹5.1 L (15.4%) | L4 | Rejected-Finance Higher Bidder |
| 5 | L5₹38.2 L+₹5.3 L (16.2%)Rejected-Finance | ₹38.2 L+₹5.3 L (16.2%) | L5 | Rejected-Finance Higher Bidder |
Tender Value
₹38.6 L
EMD Value
₹77,260
Closing Date
13 Feb 2023, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIR TO CONVERSION OF LT OH LINE INTO LT UG CABLE AT DCRA VARUNAPURI III UNDER GE NW VASCO
2023_MES_573713_1
85644/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
Yes
GE (NW) VASCO
₹77,260
Yes
4 Mar 2023
7 Jan 2023
15 Feb 2023
7 Jan 2023
13 Feb 2023
30 Jan 2023
Amount
Taking down old unserviceable ACSR conductor including channels, insulators etc complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35.0 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth getting out in soft disintegrated rock complete all as specified and as directed.
All as per item No. 7 above but exc. 1.5 m in depth and 1.5 m in width in soft/disintegrated rock for errection of poles and making good the surface complete all as specified and directed.
M & L for Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soil/rock complete all as specified and as directed.
M&L for Removal of surpuls soil/rock to a distance not exceeding 50 m and depositing where directed by Engr-in-charge complete all as specified and as directed.
M&L GI pipe medium grade 80mm dia complete with all fitting laid in ground/trench all as directed and specified complete all as specified and as directed.
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4 wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3 mm thick CRCA steel sheet as size having opening and locking arrangemant both from front and back side with cable tray of size not less than 20cm including copper busbar size 50 x 10mm fixing on angle iron size of 50 x 50 x 6mm including connected accessories and necessary PCC work 1:3:6 type C-2 blocks complete with following accessories :- (i) MCCB 400 Amps, 4 pole, 36 KA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming) (ii) MCCB 250 Amps, 4 pole, 35 KA, Fixed thermal and fixed magnetic setting- 02 Nos (outgoing) (iii) MCCB 160 Amps, 4 pole, 25 KA, Fixed thermal and fixed magnetic setting - 01 Nos (outgoing) (iv) MCCB 100 Amps, 4 pole, 25 KA, Fixed thermal and fixed magnetic setting- 02 Nos. (outgoing)
(v) S&F multi function digital meter with LCD display incl PT and CT having CTR50/5 (parameters: V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 Nos (Make : L&T 4410 series Cat Part No WL4410110000) (vi) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set (vii) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments - 01 lot
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415V, 50 HZ 3 phase 4 wire of suitable size for accomodating the following axxessories tatally enclosed self supporting structure /cubical, fully compartmentalized type, weather prrof, protection IP 52, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thich CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50 x 50 x 5mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangemant for bus bars voltmeter, ammeter, changeover switch and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement, structure treated under 7 tanks metal treatment process and duly powder coated, complete and comprising of the followingcomplete all as specified and as directed.
BUSBAR ;- (i) Copper bus bar of size 40 x 6 mm having current rating of 600 Amps, 440 volts supported on non hygroscopic fibers and brass screw for mounting - 04 Nos. INCOMER (a) supply and fixing MCCB 4 pole 440 Volts of 400 Amps - 01 Nos. INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for main supply indicating R, Y, B -03 Nos (b) Supply and fixing multi function meter incl CT having CTR 50/5 - 01 Nos ( Parameter : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) OUTGOING FEEDERS (a) Supply and fixing MCCB 4 pole 440 Volts of 250 Amps - 01 Nos (b) Supply and fixing MCCB 4 pole 440 Volts of 200 Amps - 01 Nos (c ) Supply and fixing MCCB 4 pole 440 Volts of 200 Amps - 02 Nos
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure /cubicle, fully compartmentalized typr, weather proof, protection IP 52, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50 x 50 x 5mm, with four legs grouted to PCC (1:2:4) TYPE B1, foundation block with suitable moounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement, structure treated under 8 - tank metal treatment process and duly powder coated, complete and comprising of the following all as specific and directed :- BUSBAR :- (i) Copper bus bar of size 25 x 6 mm having current rating of 400 Amps, 440 volts supported on non hygroscopic fibers and brass screws for mounting - 04 Nos.
INCOMER :- (a) Supply and fixing MCCB 4 pole 440 Volts of 250 Amps - 01 Nos INDICATING DEVICES (a) Supply and fixing LED indicating lamps for main supply indicating R, Y, B - 03 Nos (b) Supply and fixing multi function meter, incl CT having CTR 50/5 - 01 No (Parameters : V, A, F, PF, kW, kWh, kVAh, kVARh) OUTGOING FEEERS (a) Supply and fixing MCCB 4 pole 440 Volts of 200 Amps - 01 Nos (b) Supply and fixing MCCB 4 pole 440 volts of 10 Amps - 02 Nos
M & L for new Prestressed concrete pole, 11 meter long, 152 x 152 mm at top and 152 x 260 mm at bottom, class -9, erecting in truly vertical position including numbering of poles with paint and painting upto 105 m above ground level in black & white strips complete all as specified. (Earth work and PCC work measured and paid seperately)
Taking out old burnt HT cble end joint and providing new HT termination jointing kit 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm complete all as specified and directed by Engr-in-charge.
16. S & F in repairs HT/LT cable route indicator standard size made out of MS disc size 4" size with MS 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete all as specified and direced by Engr-in-charge.
Supply & Fix in repair Battery Manuel charger Unit of rating 30 V, 20 A and AC input 230 V, 50 Hz single phase, DC output 34.5 V, 20A including dry type sealed maintenance free batteries rating of each battery 12 volts 100 AH with analog voltmeters, Ammeters etc all are fitted in suitable MS sgeet enclousers hinged front operated type suitable for the operation of existing HT 33/11 KV VCB ooutdoor/indoor panels.
18. M & L for earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buired directly in ground earth pit not less than 105 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part - I including necessary excavation and earth work, GI pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth workin any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick precast RCC cover slab 1:2:4 type B with 8mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed
M & L for new RCC poles of 9 meters long having 102mm x 152mm at top and 102mm x 289mm at bottom class 11. complete all as specified and directed. Note :- Earth and PCC will be measured and paid seperately under relevant item of this schedule
Taking down old UNSV switch air break gang operated device 11000 volts & supply & install switch air break gand operated triple pole mechanically operated mounted on 15 nos insulator and steel frame ooutdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post type insulator copper alloy high pressure assembly with drop out fuses operating rod of 20mm dia GI pipe medium grade for operating from 105 m anove GL, complete confirming to IS-1318 of 1972 rated voltage 11 KV and current rating 200 Amps all as specified.
Taking out detoiriated/old coarse aggregate of any size and M& L for graded coarse aggregate of size 40 mm for spreading and levelling at substation yard all as directed and specified by Engr-in-charge.
M & L for lightening arrestor (LA) zinc oxide type complete with all fittings transmission class, discharge capacity 65 k Amp complete all as specified & directed.
Supply and fix or laying in trenches/on wall/poles/structures as in repairs GI tubing light grade of size 100 mm dia for road crossing for cable protection/fixing of pigmi lights etc, of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole fixing MS nut, bolts, & washers/MS clamps complete as required complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for any description incl preparation work is necessary complete all as specified and directed by Engr-in-charge.
M & L for PCC 1:3:6 type C-1 using 20 mm stone aggregate including use and waste of form work/ mass concrete for coping of poles/using any description complete all as specified and directed.
Supply & Lay testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts, grade cross sectional area 95 sqmm 3 core including taking out old existing cable complete all as directed at site.
Taking out old unserviceable HT/LT UG cable of any description (trenches walls, ceillings etc) from various locations, of any size upto 150 sq MM any core for rectification of faults or replacement segrregating serviceable cable & unserviceable length by meggerging or any other suitable and recommended method. Removing unserviceable burnt cable from locations and keeping a side serviceable for reuse at same location or any other location complete all as sepcified & directed by Engr-in-charge. Note :- (a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and sand for cushioning will be measured and paid seperately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape) new nut, bolt and washers of required size/description are deemed to include in this rate.
Supply and fixing of DWC pipe IS-16205, size of 61 mm inner dia & 75 mm outer dia for cable protection in wall/under ground laying or UG cables complete all as sepcified and as directed.
Supply and fixing of DWC pipe IS-16205, size of 136 mm inner dia & 160 mm outer dia for cable protection in wall/under ground laying or UG cables complete all as sepcified and as directed.
S and G Constructions
D.K. ENTERPRISES
Takshashila electricals
Shine Enterprises
BRITE INDUSTRIES
NATIONAL ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .