| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹15.7 L+₹99,440 (6.75%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹18.2 L+₹3.5 L (23.5%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹18.3 L+₹3.5 L (24.0%)Rejected-Finance 28 AVANTIBAI MARKET MAKRONIA SAUGOR MP 470004 | SAUGOR | SAGAR | MP | 470004 | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹20.3 L+₹5.5 L (37.5%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L5 | Rejected-Finance Not being lowest bidder |
| Sl No | Description | Qty | Unit | SHRI RAM ELECTRICALS ENTERPRISES L4 | M/S SHIVA TRADERS L3 | shivansh traders L2 | M/S JAINENDRA KUMAR JAIN L5 | shubhanshu traders L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable LT PCC/steel tubular pole any description complete all as specified and directed. | 15 | Each | 450 ₹6,750 | 500 ₹7,500 | 100 ₹1,500 Lowest | 400 ₹6,000 | 200 ₹3,000 |
| 2.00 | Supply and erection of steel tubular swaged pole 410 SP-31 (9.0 metre long) with CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc primer on exposed portion, two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole and marking 30 cm wide alternative strips in black and white with synthetic enamel paint upto 1.5 m from ground level and write number (not less than 10 cm in hight) using synthetic enamel paint complete all as specified and as directed. | 10 | Each | 15,500 ₹1,55,000 | 18,000 ₹1,80,000 | 17,500 ₹1,75,000 | 14,850 ₹1,48,500 Lowest | 21,500 ₹2,15,000 |
| 3.00 | Supply and erection of pre-stressed concrete pole in vertical position, 9 meter long 102mm X 172mm at top and 102mm X 279mm at bottom class-10 confirming to IS-1678 including marking 30 cm wide alternative strips in black and white with synthetic enamel paint upto 1.5 m from ground level and write number (not less than 10 cm in hight) using synthetic enamel paint complete all as specified and as directed. | 5 | Each | 5,500 ₹27,500 Lowest | 7,500 ₹37,500 | 5,500 ₹27,500 Lowest | 10,745 ₹53,725 | 10,000 ₹50,000 |
| 4.00 | S & F in replacement GI pipe 40 mm bore light grade bent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with MS clamp, nut, bolt and washer complete all as specified and directed. | 15 | Each | 550 ₹8,250 | 450 ₹6,750 Lowest | 510 ₹7,650 | 800 ₹12,000 | 600 ₹9,000 |
| 5.00 | M&L for providing junction box made of 2mm thick MS sheet of size 250x200x100mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32A-01 No, MCB SP 06 Amps, 10 KA-01 No including 02 Nos cable glands suitable for inserting cable not less than 50 sqmm with 01 No of 01mm thick GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP-65 including fixing on street light pole with MS clamps, bolts, nuts and washers all as specified and directed.
Note : The rate quoted shall include cost of MS Clamps, bolts, nuts and washers | 15 | Each | 1,550 ₹23,250 | 1,500 ₹22,500 | 1,200 ₹18,000 | 950 ₹14,250 Lowest | 1,500 ₹22,500 |
| 6.00 | Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed. | 105 | Cum | 190 ₹19,950 | 140 ₹14,700 Lowest | 190 ₹19,950 | 300 ₹31,500 | 160 ₹16,800 |
| 7.00 | Excavation in trenches in hard/dense of soil not exceeding 1.5 metre wide and exceeding 1.5metre but n.exc. 3.0m in depth and getting out complete all as specified and directed. | 0.7 | Cum | 190 ₹133 | 500 ₹350 | 200 ₹140 | 150 ₹105 Lowest | 200 ₹140 |
| 8.00 | Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. | 69 | Cum | 25 ₹1,725 | 40 ₹2,760 | 40 ₹2,760 | 150 ₹10,350 | 20 ₹1,380 Lowest |
| 9.00 | Removing excavated materials (soil) at a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed. | 36 | Cum | 25 ₹900 | 40 ₹1,440 | 40 ₹1,440 | 80 ₹2,880 | 20 ₹720 Lowest |
| 10.00 | Supply and laying sand cushioning with local dry and clean sand over and under the cable for protection of cable , 80 mm thick before laying the cable 150 mm thick after laying the cable complete all as specified and directed.
Note:- Only punned thickness of 180mm shall be measured for payment. | 32 | Cum | 1,050 ₹33,600 | 1,000 ₹32,000 | 1,050 ₹33,600 | 950 ₹30,400 Lowest | 1,100 ₹35,200 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Mar 2026, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR AND MAINTENANCE OF CAPACITOR BANK OF APFC PANEL, LT PANEL, POLES, MCCB AND MISC ALLIED WORKS AT GE SAUGOR
2026_MES_753597_1
GE/SGR/TOK-68 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Saugor
Class E category b (i) and as per tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SAGAR
₹40,000
Yes
11 May 2026
20 Feb 2026
14 Mar 2026
20 Feb 2026
12 Mar 2026
7 Mar 2026
21 Feb 2026 - 28 Feb 2026
Taking down old unserviceable LT PCC/steel tubular pole any description complete all as specified and directed.
Supply and erection of steel tubular swaged pole 410 SP-31 (9.0 metre long) with CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc primer on exposed portion, two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole and marking 30 cm wide alternative strips in black and white with synthetic enamel paint upto 1.5 m from ground level and write number (not less than 10 cm in hight) using synthetic enamel paint complete all as specified and as directed.
Supply and erection of pre-stressed concrete pole in vertical position, 9 meter long 102mm X 172mm at top and 102mm X 279mm at bottom class-10 confirming to IS-1678 including marking 30 cm wide alternative strips in black and white with synthetic enamel paint upto 1.5 m from ground level and write number (not less than 10 cm in hight) using synthetic enamel paint complete all as specified and as directed.
S & F in replacement GI pipe 40 mm bore light grade bent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with MS clamp, nut, bolt and washer complete all as specified and directed.
M&L for providing junction box made of 2mm thick MS sheet of size 250x200x100mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32A-01 No, MCB SP 06 Amps, 10 KA-01 No including 02 Nos cable glands suitable for inserting cable not less than 50 sqmm with 01 No of 01mm thick GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP-65 including fixing on street light pole with MS clamps, bolts, nuts and washers all as specified and directed. Note : The rate quoted shall include cost of MS Clamps, bolts, nuts and washers
Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed.
Excavation in trenches in hard/dense of soil not exceeding 1.5 metre wide and exceeding 1.5metre but n.exc. 3.0m in depth and getting out complete all as specified and directed.
Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated materials (soil) at a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed.
Supply and laying sand cushioning with local dry and clean sand over and under the cable for protection of cable , 80 mm thick before laying the cable 150 mm thick after laying the cable complete all as specified and directed. Note:- Only punned thickness of 180mm shall be measured for payment.
Supply and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregates) in foundation of PCC poles/ struts, etc. complete all as specified and directed
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates) for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement complete all as specified and directed
S&F in repairs aluminium conductors steel reinforced (ACSR conforming to IS : 398) Part-II)-1976 for HT/LT over head lines on PCC/ steel/rail poles including Aluminium binding wire complete all as specified and directed.
S&F in repairs GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire complete all as specified and directed.
S&F in repair stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 16 mm dia including loop insulator suitable for 1.1 KV (size 65x90 mm) with clearance of hole 16 mm and MS stay plate size 230mm x 230mm x 6mm, stay clamps complete all as specified and directed.
M&L for galvanised stay strand 7/3.15 mm or 7/4.00 mm size with minimum tensile strength of 700 N/ Sqmm and conforming to IS : 2141-1979 complete all as specified and directed.
S&F in repair pin type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel spindle, two Galvanised iron washers and one GI nut 100 mm height , 65 mm dia suitable for 1100 Volt working pressure grade (LT) complete all as specified and directed.
S&F in repair shackle type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel straps, washers, suitable bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 volts working pressure grade complete all as specified and directed.
S&F in repairs danger notice plate 1.6 mm thick mild steel sheet, viterous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT of size 20x15 cm complete all as specified and directed.
All as per item No. 20 above but plate of size 25x20 cm for HT (11 KV)
All as per item No. 20 above but plate of size 25x20 cm for HT (33 KV)
Supply only electric hand gloves rubber suitable for 11 KV/33KV line complete all as specified and directed.
Supply only safety Helmet with slide-strap adjustment yellow complete all as specified.
Supply only telestone type fibre glass discharge rod suitable for 11/33 KV line complete all as specified.
Supply only lineman safety belt for electrician weary at waist level as approved by Engr-in-Charge for working on overhead line/pole complete all as specified and as directed.
S&F in repair 19mm thick rubber mat of required shape and size as per sample kept in GE Office for sub station complete all as specified.
Supply, laying and testing of XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
All as per item No. 28 above but size of 70 sqmm, 3.5 core
All as per item No. 28 above but size of 50 sqmm, 3.5 core
M&L for earthling complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth lead 4.0 mm dia as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 40 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate No 3 of SSR 2009 Part I complete all as specified and directed. .
M&L for earthing complete with galvanised steel earth plate electrode 600mmX600mmX6 mm thick, burried directly in ground,earth pit not less than 2.25 meter deep below ground level with top edge of earth plate not less than 1.5 meter below ground level, steel earth plate connected with 25x4 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 5 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 metre connected to Panel board all as specified Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply & Fixing steel tubing GI light grade 40 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed.
Supply & Fixing steel tubing GI light grade 80 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed.
M&L for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and remove to a distance not exc 50 mtr all as directed.
M&L including fabrication of existing panel cover with hing, nut and bolt including applying two coats synthetic enemel painting complete all as specified and directed.
S&F framed work such as as indoors or gates of angle made out of Fe-410-W Gde E-250 quality-A or other section with gusset plates, rails, fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging & fastening complete all as specified and directed.
S&F in repair MCCB 4 pole , 250 Amp fixed thermal and fixed magnetic type of rating 35 KA on existing LT panel board complete all as specified and directed.
S&F in repair MCCB 4 pole , 200 Amp fixed thermal and fixed magnetic type of rating 35 KA on existing LT panel board complete all as specified and directed.
S&F in repair MCCB 4 pole , 160 Amp fixed thermal and fixed magnetic type of rating 16 KA on existing LT panel board complete all as specified and directed.
S&F in repair MCCB 4 pole , 100 Amp fixed thermal and fixed magnetic type of rating 16 KA on existing LT panel board complete all as specified and directed.
S&F in repair MCCB 4 pole , 63 Amp fixed thermal and fixed magnetic type of rating 16 KA on existing LT panel board complete all as specified and directed.
S&F in repair MCCB 3 pole , 63 Amp of rating 16 KA on existing LT panel board complete all as specified and directed.
S&F in repair contactor duty contactors type MO C-25 with add on accessories suitable for capacitor bank of exisitng APFC panel including thimbles connection complete all as specified and directed.
S&F in repair contactor duty contactors type MO C-20 with add on accessories suitable for capacitor bank of exisitng APFC panel including thimbles connection complete all as specified and directed.
S&F in repair contactor duty contactors type MO C-15 with add on accessories suitable for capacitor bank of exisitng APFC panel including thimbles connection complete all as specified and directed.
S&F in repair contactor duty contactors type MO C-12.5 with add on accessories suitable for capacitor bank of exisitng APFC panel including thimbles connection complete all as specified and directed.
Supply, fixing, connecting and testing for replacement of power factor relay RM-12/NAAC 3P12 for APFC panel of any size and any capacity including adjusting and setting up the power factor till 0.99 complete all as specified and directed.
Supply, fixing, connecting and testing for replacement of power factor relay RM-18/NAAC 3P8 for APFC panel of any size and any capacity including adjusting and setting up the power factor till 0.99 complete all as specified and directed.
S&F in repair MCB 3 pole , 63 Amp, 240 volt, C series, 10 KA complete all as specified and directed.
S&F in repair heavy duty capacitor cylindrical/box type 1 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 2 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 3 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 4 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 10 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 12.5 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 15 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 20 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair heavy duty capacitor cylindrical/box type 25 KVAR, 440Volt suitable for existing capacitor bank at site complete all as specified and as directed.
S&F in repair flat cable flexible copper of size 2.5 sqmm 3 core, 1100 volt grading complete all as specified and as directed.
S&F in repair mild steel chequered plate of 5 mm thick or over in thickness in available of Fe - 290 Gde E165 and fixed in substation building including painting with black colour over one coat of red oxide primeover and making provision for lifting the plate from duct complete all as specified and directed.
S&F in repair cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat with red oxide primer, one under coat and one finishing coat of paint with synthetic enamel paint complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TENDER_TOK68.pdf
Tender Documents • 1.39 MB
BOQ_844072.xls
BOQ • 0.38 MB
Amd0168.pdf
PDF • 0.35 MB
Amd68.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .