Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 CrAccepted-AOC 320 NAWADA BAZAR GALI CHHWALIYAN NAJAFGARH SOUTH WEST DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹23.8 Cr Quoted ₹23.9 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹24.3 CrRejected-Finance | ₹24.3 Cr | L2 | Rejected-Finance HIGHER |
| 3 | L3₹24.6 CrRejected-Finance 218 26 CHAKRIYA PURI SONIPAT ROAD ROHTAK 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | ₹24.6 Cr | L3 | Rejected-Finance HIGHER |
| 4 | L4₹24.6 CrRejected-Finance RAM NAGAR NEW BUS STAND NARWANA 126116 | NARWANA | JIND | HARYANA | 126116 | ₹24.6 Cr | L4 | Rejected-Finance HIGHER |
| 5 | L5₹25.4 CrRejected-Finance | ₹25.4 Cr | L5 | Rejected-Finance HIGHER |
| Sl No | Description | Qty | Unit | m/s omparkash contractor L3 | P.S. INFRABUILD PRIVATE LIMITED L5 | Raghbir Singh Contractor L4 | The Tibba Dana Sher Co Op L and C Society Limited L6 | UNIVERSAL CONSTRUCTION COMPANY L1 | m/s Bishan parkas & company L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Credit of old steel bars | 322.81 | Quintal | 3,000 -₹9,68,442 | 3,000 -₹9,68,442 | 4,000 -₹12,91,256 | 3,500 -₹11,29,849 | 3,000 -₹9,68,442 | 3,000 -₹9,68,442 |
| 2.00 | credit of bricks and B.Bats available from dismantling of Brick Masonry | 2,374.5 | cum | 880 -₹20,89,557.36 | 880 -₹20,89,557.36 | 1,000 -₹23,74,497 | 1,000 -₹23,74,497 | 880 -₹20,89,557.36 | 880 -₹20,89,557.36 |
| 3.00 | Providing and fixing gates and gearing complete in all respect | 185.91 | Sqm | 75,000 ₹1.4 Cr | 50,000 ₹93.0 L | 50,000 ₹93.0 L | 70,000 ₹1.3 Cr | 43,000 ₹79.9 L | 60,000 ₹1.1 Cr |
| 4.00 | Fabrication (erection and commissioning of wheel assembly with GM bush of size 400*150 complete in all respect | 40 | NO. | 45,000 ₹18 L | 40,000 ₹16 L | 40,000 ₹16 L | 40,000 ₹16 L | 33,800 ₹13.5 L | 40,000 ₹16 L |
| 5.00 | Providing and fixing gate and gearing complete ina ll respects as per satiscfaction of Engineer-in-Charge | 7.74 | Sqm | 75,000 ₹5.8 L | 50,000 ₹3.9 L | 50,000 ₹3.9 L | 70,000 ₹5.4 L | 43,000 ₹3.3 L | 60,000 ₹4.6 L |
Tender Value
₹28.2 Cr
EMD Value
₹56.4 L
Closing Date
5 Mar 2026, 1:00 pmClosed
ARUN MUNJAL
Rohtak W.S. Divn. Rohtak
Reconstruction/Construction of various structures from RD 82500 to 124000 of Bhalaut Sub Branch.
2026_HRY_502496_1
202660F29F87 28BE 4C03 9BB7 7EBD3F3BF30A125IRR
Open Tender
Civil Works
360 days
DHAMAR KILOI KHAS LADHOT RITHAL NARWAL RITHAL
3 documents required · 3 mandatory
₹20,000
₹56.4 L
Yes
Room No. 220 1st Floor, Sinchai Bhawan
11 May 2026
13 Feb 2026
5 Mar 2026
13 Feb 2026
5 Mar 2026
13 Feb 2026
23 Feb 2026
Credit of old steel bars
credit of bricks and B.Bats available from dismantling of Brick Masonry
Providing and fixing gates and gearing complete in all respect
Fabrication (erection and commissioning of wheel assembly with GM bush of size 400*150 complete in all respect
Providing and fixing gate and gearing complete ina ll respects as per satiscfaction of Engineer-in-Charge
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[11.25.1]Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1. Flush / Ruled/ Struck or weathered pointing [Through Rate]
[14.1]Dressing bed and preparation of sub grade for lining by mechanical/ mannual means [Through Rate]
[14.2]Dressing side slopes and preparation of sub grade for lining by mechanical/ mannual means [Through Rate]
[14.71]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . [Through Rate]
[15.6.4]Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 4. Cement Mortar1:6 (1cement :6 sand) [Through Rate]
[17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate]
[2.B0146] B0146. Brick bats [Rate]
[2.RM079] RM079. Earth Cost or compensation for earth taken from private land [Rate]
[27.1]Brick masonry work in 1:3 in sub-structure including scaffolding complete excluding pointing and plastering, as per drawing and MoRTandH Specifications 1300 and 2200 [Through Rate]
[27.10.1.2]RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump [Through Rate]
[27.13]Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and MoRTandH Specifications 1600 & 2200. [Through Rate]
[27.15]Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing force. Complete as per drawing and MoRTandH Specifications 2706 & 2200. [Through Rate]
[27.16.1]Back filling behind abutment, wing wall and return wall complete as per drawing and MoRTandH Specification 710.1.4 of IRC: 78 and 2200. 1. Granular material [Through Rate]
[27.16.2]Back filling behind abutment, wing wall and return wall complete as per drawing and MoRTandH Specification 710.1.4 of IRC: 78 and 2200. 2. Sandy material [Through Rate]
[27.17]Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and MoRTH and Specification 710.1.4 of IRC: 78 and 2200. [Through Rate]
[27.28.1.1]Using Batching Plant, Transit Mixer and Concrete Pump 1.1. For formwork and staging add the following: For solid slab super-structure, 20-30 per cent of labour, material and machinery cost Height up to 5m [Through Rate]
[27.44.2]Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position [Through Rate]
[27.49]Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm and MORT&H specification 800. [Through Rate]
[27.5]Plain/Re-inforced cement concrete in sub-structure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m [Through Rate]
[27.51.3]Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. [Through Rate]
[34.4.1]Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports including three year outdoor weathering test report for sheeting tested in India condition from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 [Through Rate]
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
[5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate]
[5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate]
[5.33]Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. [Through Rate]
[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
[6.22.2.2]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.2. All works up to Plinth Level : M-15 grade plain cement concrete. (cement content considered @ 240 kg/cum) [Through Rate]
[6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate]
[7.21.3]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 3. Cement mortar 1:3 (1 cement : 3 coarse sand) [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_581157.xls
BOQ • 0.32 MB
OT0151776.pdf
Other Document • 0.74 MB
Download all tender documents and submit your bid