Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹33.0 L+₹2.2 L (7.28%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹36.2 L+₹5.4 L (17.5%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹38.0 L+₹7.3 L (23.6%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹40.1 L+₹9.3 L (30.2%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹48.1 L
EMD Value
₹96,500
Closing Date
28 Dec 2024, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT
SPECIAL REPAIR REPLACEMENT OF LT XLPE UG CABLES OF OFFICERS MD ACCN BLOCK NO P151 TO P200 STREET LIGHT CABLES AND CONNECTED ITEMS AT DHAULA KUAN PART II UNDER GE U ELECT SUPPLY DELHI CANTT 10
2024_MES_687640_1
GE ELECT/D-80/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE UTILITY ELECTRIC SUPPLY
₹96,500
Yes
24 Jan 2025
7 Dec 2024
30 Dec 2024
7 Dec 2024
28 Dec 2024
21 Dec 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old bricks complete all as specified and directed by Engineer- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed Cables of the following sizes:- Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
95 Sq mm 3.5 core.
240 Sq mm 3.5 core.
Supply, fixing and testing Straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armored heavy duty aluminum conductor 1100 Volts grade complete all as directed for the following sizes :-
70 -120 sqmm x 3.5 core
240-300 sqmm ,3.5 core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr- in- Charge.
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah etc complete all as specified and directed by Engr- in- Charge of following bore sizes:-
40mm bore
50mm bore
80mm bore
S&F MCCB 200 Amp, 4 pole , 25 KA, 50 Hz with MCCB sheet metal enclosure mounted on wall with fastner with suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU complete all as specified and directed by Engr- in- Charge
M&L in replacement for earthing complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed by Engr- in- Charge.
S&F in replacement of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified and directed by Engr- in- Charge.
S&F in replacement KIOSK box wheather proof made out of one piece mounted SMC base and door pole mounted hinged door of size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer for fixing complete all as specified and directed by Engr- in- Charge.
Taking down unservicable RCC/ steel tubular poles of any type and supply & install Steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including all necessary excavation, earth work, PCC foundation, base plate, PCC coping, GI pipe for cable protection etc and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed by Engr- in- Charge.
(b) Outgoing:- (i) MCCB 250 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release -01 Nos. (ii) MCCB 160 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 04 Nos. (iii) MCCB 125 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos. (c) Platform of Panel:- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note:- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer .
S&F in replacement of time switches astro type having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paint and incl fixing on existing panel/box etc complete all as specified and directed by Engr- in- Charge.
Supply, drawing, connecting & testing in replacement of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 on steel tubular pole/PCC Pole from KIOSK box to light fittings including PVC conduit and providing suitable copper lugs complete all as specified and directed by Engr- in- Charge.
M&L for Plain cement concrete (PCC) type B1 1:2:4 using 20mm graded aggregate stone for making copings of Poles or similar works complete all as specified and directed by Engr- in- Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
M/s JAIMAA ASSOCIATES (BID ID -3201013)
MV Engineers And Contractors (BID ID -3200890)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3201174)
Vijay Electricals (BID ID -3200633)
Ridhi engineers and builders (BID ID -3200988)
M/S VEDHANT ASSOCIATES (BID ID -3200569)
SHREE BALAJEE ENTERPRISES (BID ID -3200864)
DS CONSTRUCTION (BID ID -3200678)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .