| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹37.4 L+₹39,380.50 (1.06%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹38.5 L+₹1.5 L (4.02%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹39.1 L+₹2.1 L (5.54%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹40.4 L+₹3.4 L (9.24%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹89,900
Closing Date
17 Mar 2021, 6:00 pmClosed
GE NDA KHADAKWASLA
GE NDA KHADAKWASLA
REPAIR/MAINT OF STREET LIGHTS AND SECURITY LIGHTS AT NDA KHADAKWASLA
2021_MES_424108_1
GE (K) 61 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
GE NDA KHADAKWASLA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADAKWASLA
₹89,900
Yes
16 Apr 2021
20 Feb 2021
19 Mar 2021
21 Feb 2021
17 Mar 2021
5 Mar 2021
22 Feb 2021 - 4 Mar 2021
Amount
Repair / maintenance of street / security lights any type, flood lights, post top lanterns or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like choke (ballast), electronic driver (in case of LED lights), ignitor, capacitor, lamp, lamp holder, connector, connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including labour for repair / maint of street light control timer & junction box all as directed.. Note: (i) Cost of spares Choke (ballast), electronic driver, ignitor, capacitor, lamp, lamp holder, connector, connection wire, MCB, timer spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (ii) The defects / repair of the street light making them functional after handing over defective street light The repair/maint shall be carried out simultaneously for different zones / pocket / areas like :- (a) Training & administrative bldgs area including main road from Trishakti gate to Bombay stadium (b) Offrs residential area D1, D2, D3, E3 including main road from Bombay stadium to peacock bay, road to LVGH & Kondhana (c) JCOs/OR and followers residential area. (iii) Vehicle mounted hydraulic ladder shall be provided which will be measured separately under Schedule 'C'. (iv) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and getting it authenticated. (vii) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. (ix) Maintaining sufficient stock of spares / material required for repair / maint of street lights as per Appx A to Sch A against the supply only items here-in-below.
Supply only following street light spares of branded make as mentioned in BOQ or else the list of make enclosed with Particular specifications for replacement :- HPSV open construction ballast suitable for 70 watts HPSV / MH street light fitting, 240volts 50 Hz. Make Crompton or Philips/Wipro
Supply only HPSV open construction ballast suitable for 150 watts HPSV / MH street light fitting, 240volts 50 Hz. Make Crompton or Havells/Wipro
Supply only HPSV open construction ballast suitable for 250 watts HPSV / MH street light fitting, 240volts 50 Hz. Make Crompton or Havells/Wipro
Supply only HPSV open construction ballast suitable for 400 watts MH street light fitting, 240volts 50 Hz . Make Crompton or Havells/Wipro
Supply only HPSV lamp tubular 70 watts . Make Crompton or Havells/Wipro
Supply only HPSV lamp tubular 150 watts .Make Crompton or Havells/Wipro
Supply only HPSV lamp tubular 250 watts .Make Crompton or Havells/Wipro
Supply only Metal halide lamp double ended 150 watts. . Make Crompton or Havells/Wipro
Supply only Metal halide lamp double ended 70 watts. . Make Crompton or Havells/Wipro
Supply only MH lamp 150 watts tubular .Make Crompton or Havells/Wipro
Supply only Metal halide lamp 250 watts tubular. .Make Crompton or Havells/Wipro
Supply only MH lamp 400 watts tubular . Make Crompton or Philips/Wipro
Supply only Compact fluoresent lamps 18 watt cross pin for post top lantern(CFL PIN TYPE) . Make Crompton or Havells/Wipro
Supply only Regular electronic Ballast for 18 watts FTL / CFL. . Make Crompton or Havells/Wipro
Supply only Porcelain holder for HPSV lamp 70/150/250/400 watts . Make Crompton or Havells/Wipro
Supply only Ignitor suitable for 70 watts HPSV/MH fitting . Make Crompton or Havells/Wipro
Supply only Ignitor suitable for 150/250/400 watts HPSV/MH fitting . Make Crompton or Havells/Wipro
Supply only Capacitor 15 MFD . Make Crompton or Havells/Wipro
Supply only Capacitor 20 MFD . Make Crompton or Havells/Wipro
Supply only Capacitor 33 MFD . Make Crompton or Havells/Wipro
Supply only MCB SP 230 volts B curve 6 amps Make L&T, Indoasian,Legrand)
Supply only MCB SP 230 volts B curve 10 amps Make L&T, Indoasian,Legrand)
Supply only MCB TPN 230 volts C curve 63 amps Make L&T, Indoasian,Legrand)
Supply only but MCB TPN 230 volts C curve 40 amps Make L&T, Indoasian,Legrand)
Supply only Digital time switch, DIN type daily / weekly with 25 ON/OFF programmes , 16 amps 250 volts AC Make L&T or Legrand/Indoasian
Supply only Astro time switch Sunrise/sunset trigger modes ,16 amps 250 volts AC Make L&Tor Legrand/Indoasian
Supply only Power contactor 16/18 amps 3 pole
Supply only Power contactor 40 amps 3 pole
Supply only PVC insulated Copper conductor FRLS grade two core cable 1.5 sqmm, ISI marked
Supply only MCCB 63 Amps 4 pole 415 V Make L&T, Indoasin,Legrand)
Supply only PVC insulated aluminium conductor FRLS grade two core cable 1.5 sqmm, ISI marked
Supply only Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer.
Supply only Electronic driver for 40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer
Supply only Electronic driver for 300 watts flood lights Make should be as per the Existing manufacturer
Supply only Electronic driver for 200 watts flood lights Make should be as per the Existing manufacturer
Supply only Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer
Supply only Electronic driver for 100 watts flood lights Make should be as per the Existing manufacturer
Supply only Surge protection device(SPD) of capacity 10KV compatible with industrail & outdooor LED fixtures Make should be as per the Existing manufacturer
Supply only Relay of capacity 110V-240V AC Capacity Make : L&T catpart No: CS94039/Legrand/ Indoasian
Restreaching tightening and fixing in position, the existing OH ACSR conductor LT Line 3 phase with neutral and earth wire 440 V 5/6 wire by loosing and taking down existing binding wire from the insulator of any size of ACSR conductor and bring it to required sag incl new binding wire and tightening of cross arm on each pole and required trimming of tree branches NOte: 1.Span length (any Nos of wire of conductor shallbe measured in running meter unit combined. 2. Unit rate quoted by the contractor shall be deemed to incl for cutting and trimming branches of the trees coming in contact with ACSR conductor and separators complete all as directerd
Supply & Laying, jointing & testing of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 10 sqmm 4 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size complete all as specified and directed
Ditto all as per item No. 42 above but size 16 sqmm 4 core
Ditto all as per item No. 42 above but size 25 sqmm 3.5 core
Ditto all as per item No. 42 above but size 4 sqmm 3 core
Taking out existing defective worn out UG LT cable of any size 1100 volts grade from trenches of any size from different locations incl brick bats etc complete, all as specified and directed. (Note: Excavation & earth wk shall be measured and paid for separately)
Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed.
Excavation in trenches in soft/dis integrated rock n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed.
Excavation in trenches in soft/dis integrated rock n exc 1.5m wide and exc 1.5m in depth and n.exc 3 mtr in depth and getting out complete all as specified and directed.
Returning, filiing in incl spreading, leveling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested as specified
Removing excavated surplus soil obtained from excavation not exc 50 m and depositing where directed of a level not exceeding 1.5 m above the starting point, complete all as specified.
M&L for laying of reinforced concrete pipe, dia of 150 mm 2 nos half round for bottom and top and before laying excaved area shall be levelling all as specified and directed . Note: One half round Top and One half round bottom together will be considered as one running meter. Make as per sample keet in office.
S&F in replacement of sintex box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 295mm x 195 mm x 100 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed. Make Sintex Cat pat No GSJB-3020 or equivalent in any other approved makes.
S&F in repair of GI pipe bracket of 32 mm dia 1.2mtr long bend to shape for street light fitting made out of 32 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
Labour for trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights complete all as directed in such a way that the clearance between Street light pole and tree branches should not be less than 1.5 mtrs around the Pole/Fitting complete all as directed.
M&L for tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm for laying of 80 MM medium grade GI pipe incl refilling and making good with Tarmac/ PCC duly matching with the existing surface Note:1. Quoted rate shall be including of 80 MM Gi pipe medium grade 2. Quoted rate shall deemed to including the cost of making good the disturbed surface.
Removing existing damaged reflected strips from pole supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with red colour complete all as directed.
Removing existing damaged reflected strips from pole supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with yellow colour complete all as directed
Removing existing damaged reflected strips from pole supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with whitecolour complete all as directed.
S&F in replacement 9 w LED bush and spike light luminaires in IP 65 enclosure warm white light output, Make: Luker/Wipro/Polycab
S & F in replacement of 100 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed. Make: Luker/Wipro/Polycab
S & F in replacement of 150 watts flood light Warm white /White in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed. Make: Luker/Wipro/Polycab
S & F in replacement of 200 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed. Make: Luker/Wipro/Polycab
S&F in replacement of 60 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete directed Make - Luker/Wipro/Polycab
S&F in replacement LED 90 watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixing to pole/wall with necessary nut, bolts and washers complete all as specified and directed. Make: Luker/Havells/Crompton
S&F in replacement of LED 48/50 watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed. Make: Luker/Wipro/Polycab
M&L for straight through joint (epoxy) for PVC insulated and sheathed aluminium conductor under ground cable incl freud , thimbles, nut & bolts, washers etc and testing afterjointing complete, all as specified and directed Make M-seal/Raychem/Cabseal/Denson 16 sqmm to 35 sqmm 3.5 core
S&F in replacement 18 Watt weatherproof LED post top lantern with aluminium housing, clear acrylic diffuser, aluminium pole-cap complete with all accessories complete all as specified and directed Make- Luker/ Philips/Bajaj
S&F in replacement of Heritage 20 watt Warm white LED IP 65 rated LED post top ideal fitting to be fixed in existing RCC pole with suitable fittings as per site requirement complete all as specified and directed Make Crompton Model No LPTH-20-WW or eqv of Wipro/Philips
S&F in replacement 40 watt LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and directed. Make bajaj Cat No ARIAN BGCT W4 LED WW or eqv to other approved makes
S&F in replacement integral 40 Watt LED post top lantern black/ copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessories complete with 50 mm OD black powder coated MS pipe not less than .3mtr length with suitable 5 mm thick ms base plate with provn of 04 Nos anchoring bolts complete all as specified and directed. Make Bajaj (CELESTA) Cat No BGCL 40W LED WH / Wipro/Luker/ Havells
S&F in replacement integral LED aviation light comprising housing with polycarbonate enclosure, aviation light is to be fixed on highmast light frame complete all as specified and directed. make Bajaj/Havells/Wipro/Luker/ Havells
S&F GI tubing light grade 40 mm dia isi marked appx 1 mtr to 1.5 mtr long with Flat Iron Base for mounting of Flood light with all fittings incl nut,bolt,washers suitable size complete all as specified and directed at size.
M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT (07 to 08 Mtr) height above ground level , preparing surface for painting , applying two coats of aluminium paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site including making balck and white strips of 30 cms each upto 1.5 m above PCC muffs with black and white paint and marking of pole No 2 m above PCC muff, letter should not be longer than 6 cm height with 16 cm dia circle around the marked NO complete all as such specified and directed.
M&L for scrapping down and removing of old deteriorated paint from Post top lantern poles (RCC/GI) /(2 to 3 mtr) height above ground level , preparing surface for painting , applying two coats of black paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site complete all as such specified and directed .
S&F in replacement of HOT dip galvanised Octagonal pole 9 mtr height having across faces bottom side 155 mm top side 70 mm made out of 3 mm thick HT sheet steel plate along with base plate of size 250x250x16 mm thick and required nut ,bolts, sutable PCC foundation if reqd as per manufacture instructions complete all as specified and directed.
S&F 60 W mini high mast light, energy saving , elegantly designed cast aluminium housing and heat sink for thermal management, high efficiency long life LED module aesthetically designed diffuser and reflector to deliver uniform light output, suitable for mounting on existimg pole with 06 Nos SS allen screws M4x16 complete all as specified and directed. Make Luker eqvt in Philips/Wipro
S&F of 70 W WW LED Out door post top light ,Correlated colour temperature 3000 K, post top with diecast aluminium body dark grey incl surge protection up to 2 KV confirm to IP-65 , incl suitable arrangements for 3 mtr decorative pole complete directed Make : Havells Catpart No: TYCOONPT70WLED730PSYMTOPC or equivalent in havells or philips
S&F 1x18 watt WW (3000K) LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements all as directed Make Luker Catpart No: LOBRD60 or equivalent in havells or philips (Quoated rate includes PCC work also)
S&F 1x12 watt WW (3000K) LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements all as directed Make Luker Catpart No: LODBR12 or equivalent in havells or philips
S&F 9 watt Integral LED bollards with opal acrylic diffuser and IP65 incl PCC foundation with suitable nut and bolts as per site requirement complete all as specified and directed. Make- Bajaj Cat Pat No. BGBOS 600 9W LED /Phillips/CG
S&F 1x10 watt WW (3000K) LED outdoor gate light with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements all as directed Make Luker Catpart No: LGLSMD or equivalent in havells or philips
S&F 1x18 watt WW (3000K) LED bollard outdoor gate light with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements all as directed Make Luker Catpart No: LGLSBG or equivalent in havells or philips
S&F 1x18 watt WW (3000K) LED bollard outdoor gate light with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new bollard as per site requirement and fixing arrangements all as directed Make Luker Catpart No: LGLRBGE-27 or equivalent in havells or philips
S&F in replacement of LED rope light IP 65 with 5050 LED, warm white incl 2 Pin power supply connector,Connector pin, and End cap as per site requirement fixing at roof of the bldg with suitable PVC saddles for every one mtr on rope. Make : Luker/ Wipro/ Polycab
Connector suitable for LED 50 50 Strip
Connector pin suitable for LED 50 50 Strip
Supply, transport, errecting and fixing steel tubular swaged welded pole of over all height 8.5 m long complete type 410-SP-22 conforming to IS-2713 (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed. Note: (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer. (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv) Pole below ground shall be tarred by one coat (v) Poles shall be numbered and the rate for above items shall be deemed to be inclusive in the quoted rate.
M&L for PCC (1:3:6) type C-1 (Using 40 mm graded stone aggregate) Cement concrete in foundations, filling and mass concrete complete all as specifed.
M&L for PCC (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in coping of pole including form work and demolition of existing coping complete all as specifed and directed.
M&L for PCC (1:4:8) (Using 40 mm graded stone aggregate) Cement concrete in foundations, filling and mass concrete complete all as specifed.
S&F in replacement of automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights , including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement all as specified and directed
S&F astronomical timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB power contactor and 230V digital time switch for controlling LED/SV etc street lights , including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35 mm x 35 mm x 4 mm thick angle iron supports of not less than each 0.6 m height duly painted with anti corrosive black paint and grouted in PCC (1:3:6) at suitable depth as per site requirement complete all as specified and directed.
S & F in replacement busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 300mmX40mm X5mm(thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each .3 mtr height duly painted with anti corrosive black paint and grouted on wall (at Sudan Dome)and suitable fixing arranement as per site requirement. The overall size of the Busbar panel shall be 350mmx200mmx400mm (LxBxH).including PCC (1:3:6) complete all as directed and specified.
S&F flexible conduit pipes of dia not less than 19 mm complete all as specified and directed. Make: As per sample approved
M&L for installing GI Pipe medium grade 40mm dia on existing PCC wall by making hole of length 40cm including hole for connection wire and making good with existing surface all as specified and directed
Disconnecting/taking down the hexagonal/ Hectagonal GI Pole which is titling/leaning by engaging suitable crane or manullay and refixing the same with suitable nut and bolt on existing foundation complete all as specified and directed
SONU ENTERPRISES
SHAILENDRA B TULSANI
Tejas Enterprises
G V HAGAWANE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .